Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE — 2RT5 flanged is designed for use with a drywall adapter kit. This combination allows for the installation of the 2RT5 in any area with drywall ceilings common in reception and elevator areas and stairwells. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. OPTICAL SYSTEM — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal amount to walls, cubicles, work surfaces and people. Luminous characteristics are carefully managed at high angles to deliver just enough intensity to deliver the volumetric effect. Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector with light. Linear faceted reflector softens and distributes light into the space and minimizes the luminance ratio between the fixture and the ceiling. Mechanical cut-off across the reflector and fresnel refracton along the refractor provide high angle shielding and a quiet ceiling. Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth. CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer lightdiffusing film. Rugged center reflector section is hinged to fixture and held in position with two captive screws. Room side access to ballast and wiring compartment. Cold rolled steel reflectors are embossed with linear facets and polyester powder painted after fabrication. Rigid structure with ballast box and endplates. DGA24 flange trim ships separately. ELECTRICAL SYSTEM — Highly efficient program-start electronic ballasts, Class P, thermally protected, resetting, HPF, non-PCB, UL Listed, CSA Certified, sound rated A+. Your choice of Premium or Premium XP T5 lamp with enhanced phosphors and 85 CRI. Ballast/lamp efficacy up to 100+ LPW. Lamp is TCLP compliant. 0.90 or 0.95 ballast factor standard for typical applications. 1.15 ballast factor or F54T5HO lamping available for higher ceiling height applications. Step-dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance. Listed ballast disconnect with strain relief and leads provided standard for non-emergency fixtures. S5 option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming. See SYNERGY® Lighting Controls specification sheets for more information. Ballast Disconnect provided standard where required to comply with U.S. and Canadian electrical codes. MAINTENANCE — Hinged center reflector swings down for hands-free room side access to ballast and wiring compartment. Lamps accessed by squeezing refractor to release from retention tabs. 2RT5 FLANGED 2'X 4' 2 Lamps Premier and Premier XP T5 Specifications Length: 48 (1218) Width: 24 (610) Depth: 3-1/8 (79) All dimensions are inches (millimeters) unless otherwise specified. LISTING — UL Listed (standard). Optional: Canada CSA or cUL. Mexico NOM. WARRANTY — Fixture guaranteed for one year against mechanical defects in manufacture. Lamp and ballast system warranty (24 months for lamp, 60 months for ballast) by lamp and ballast manufacturer. Protected by one or more of US Patents Nos. 7,229,192; D541,467; D541,468; D544,633; D544,634; D544,992; D544,933 and additional patent pending. Specifications subject to change without notice. For shortest lead times, configure product using standard options (shown in bold). Example: 2RT5 28T5 F MVOLT GEB95S LPM835P ORDERING INFORMATION F 2RT5 Series Voltage 2RT5 Recessed T5 MVOLT3 Lamp type 28T5 28W T5 (46") 3474 Trim type F Flange2 54T5HO 54W T5 (46")1 NOTES: 1 For T5HO applications, use GEB10PS, GEB80 or GEB80S ballast. 2 DGA24 flange trim ships separately. 3 MVOLT (120-277 volts), 50-60HZ. 4 For 347V, use GEB95S or GEB10PS. 5 SIMPLY5 available with HW (hardwire) only. 6 Required. All fixtures shipped with lamps installed. 7 Must specify voltage, 120 or 277. 8 See PS1400QD spec sheet for EL lumen output information. Fluorescent Ballast GEB95 0.95 ballast factor GEB95S 0.95 ballast factor, step dimming GEB115 1.15 ballast factor GEB115S 1.15 ballast factor, step dimming GEB10PS 1.0 ballast factor, program start S5 0.95 ballast factor SIMPLY5 system5 GEB10PS 1.0 ballast factor, program start1 GEB80 .80 ballast factor1 GEB80S .80 ballast factor, step dimming 1 GEB90 .90 ballast factor GEB90S .90 ballast factor, step dimming Lamp 6 Options LPM835P Premier 3500°K 28W lamp GLR Internal fastblow fuse7 LPM830P Premier 3000°K 28W lamp LPM841P Premier 4100°K 28W lamp L835XP Premier XP 3500°K 28W lamp L830XP Premier XP 3000°K 28W lamp L841XP Premier 4100°K 28W lamp LP835 3500°K 54W lamp LP830 3000°K 54W lamp LP841 4100°K 54W lamp EL14 Emergency battery pack8 HW Hardwire for S5 system; replaces RELOC ® CSA Listed and labeled to comply with Canadian standards QFC_ Quick-flex cable7 Sheet #: 2RT5-2x4-F VRL-120 2RT5 Volumetric Recessed Lighting 2' x 4' Flanged MOUNTING DATA RT5/2RT5 with flanged mounting option is a recessed fixture featuring room-side ballast access plus a mounting accessory, a drywall-to-grid adaptor (DGA) supported with tie wire (by others) to the overhead building structure (see detail below). Fixtures mounted with DGA accessories are not suitable for endto-end row mounting. Rough-in dimensions for DGA-equipped fixtures are 7/8" longer in length and width, than the dimensions for standard flanged fixtures. RT5 fixture size 1' x 4' 2' x 2' 2' x 4' Rough-in opening for DGA accessory 12-7/8" x 48-7/8" 24-7/8" x 24-7/8" 24-7/8" x 48-7/8" PHOTOMETRICS 2RT5 28T5 GEB95 LPM835P, (2) FP28/835/PM/ECO lamps, 2730 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL13260 LER: 80.4 lpw *The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration. Ballast GEB90, GEB90S GEB90S @ 50% power mode GEB95, GEB95S GEB95S @ 50% power mode GEB115, GEB115S GEB115S @ 50% power mode GEB80, GEB80S GEB80S @ 50% power mode S5 Input Wattage 120/277 55/54 27 60/58 28/28 73/71 35/35 96/93 52/51 60/58 System 3-lamp T8 2RT5 2-lamp T5 2RT5 2-lamp T5 2RT5 2-lamp T5 T5/T8 Energy Comparison Lamp Ballast Input Watts Saved Type Factor Watts Compared to T8 F32T8 0.88 88 – F28T5XP 0.90 54 34 F28T5 0.95 58 30 F28T5 1.15 71 17 Lithonia Lighting Sheet #: 2RT5-2x4-F ©2006 Acuity Brands Lighting, Inc., All rights reserved, Rev. 11/17/09 Fluorescent One Lithonia Way, Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com
© Copyright 2026 Paperzz