Roof Exhaust Performance and Dimensional Data XRED-060 and 065 - Direct Drive 193/8 (492) *121/8 (308) 13/4 (44) 17 (432) cfm Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) ^Approximate Unit Weight = 18 lbs. (8 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-060-E 1/200 1050 XRED-060-G 1/100 1300 XRED-060-D 1/60 1550 XRED-065-E 1/100 1050 XRED-065-G 1/60 1300 XRED-065-D 1/30 1550 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 138 0.00 1.7 170 0.01 2.9 203 0.01 4.2 187 0.01 2.2 231 0.01 3.2 276 0.02 4.9 0.05 116 0.00 1.7 153 0.01 2.8 188 0.01 3.9 161 0.01 2.1 211 0.01 3.1 259 0.02 4.6 0.1 90 0.01 1.7 135 0.01 2.8 173 0.01 3.8 130 0.01 1.9 189 0.01 3.0 241 0.02 4.5 0.125 73 0.01 1.7 125 0.01 2.7 166 0.01 3.8 110 0.01 1.8 178 0.01 2.9 232 0.02 4.5 0.15 53 0.01 1.7 113 0.01 2.7 158 0.02 3.8 87 0.01 1.7 163 0.01 2.9 223 0.02 4.4 0.2 0.25 0.3 85 0.01 2.6 140 0.02 3.7 120 0.02 3.7 92 0.2 3.6 130 0.01 2.8 201 0.02 4.3 92 0.01 2.7 176 0.02 4.3 145 0.02 4.1 0.375 0.4 96 0.02 4.0 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 235 ] Roof Exhaust Performance and Dimensional Data XRED-070 and 075 - Direct Drive 193/8 (492) *121/8 (308) 13/4 (44) 17 (432) Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) ^Approximate Unit Weight = 18 lbs. (8 kg) cfm All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-070-E 1/100 1050 XRED-070-G 1/60 1300 XRED-070-D 1/30 1550 XRED-075-E 1/80 1050 XRED-075-G 1/50 1300 XRED-075-D 1/25 1550 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 253 0.01 2.7 314 0.01 4.1 374 0.02 5.6 297 0.01 3.6 367 0.02 4.1 438 0.03 6.1 0.05 226 0.01 2.1 292 0.1 3.7 356 0.02 5.4 260 0.01 3.1 338 0.02 3.9 413 0.03 5.8 0.1 195 0.01 1.7 269 0.02 3.4 337 0.02 5.2 222 0.01 2.9 309 0.02 3.7 389 0.3 5.6 0.125 179 0.01 1.5 2557 0.02 3.3 327 0.03 5.2 200 0.01 2.8 293 0.02 3.7 377 0.04 5.4 0.15 152 0.01 1.2 244 0.02 3.2 317 0.03 5.1 176 0.01 2.6 277 0.02 3.7 364 0.04 5.3 0.2 0.25 0.3 0.375 214 0.02 2.9 297 0.03 4.9 171 0.02 2.6 274 0.03 4.7 244 0.03 4.5 190 0.03 4.1 241 0.02 3.6 337 0.04 5.1 195 0.02 3.5 309 0.04 4.9 277 0.04 4.9 214 0.03 4.8 0.4 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 236 ] Roof Exhaust Performance and Dimensional Data XRED-080 and 085 - Direct Drive 213/4 (552) *145/8 (371) 13/4 (44) 17 (432) cfm Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 26 lbs. (12 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-080-E 1/40 1050 XRED-080-G 1/30 1300 XRED-080-D 1/20 1550 XRED-085-E 1/40 1050 XRED-085-G 1/30 1300 XRED-085-D 1/20 1550 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 335 0.01 3.8 415 0.02 5.4 495 0.04 7.3 398 0.01 4.0 493 0.02 5.5 588 0.04 7.6 0.1 268 0.02 3.7 361 0.03 5.4 450 0.04 7.3 326 0.02 3.9 436 0.03 5.3 541 0.04 7.4 0.125 249 0.02 3.6 348 0.03 5.4 439 0.04 7.3 307 0.02 3.9 420 0.03 5.3 528 0.05 7.4 0.15 230 0.02 3.7 333 0.03 5.4 427 0.05 7.3 286 0.02 3.9 405 0.03 5.3 515 0.05 7.4 0.2 189 0.02 3.9 303 0.03 5.4 404 0.05 7.3 240 0.02 4.1 375 0.03 5.3 490 0.05 7.4 0.25 134 0.02 4.2 272 0.03 5.5 379 0.05 7.2 179 0.02 4.3 340 0.04 5.3 464 0.05 7.4 0.3 0.375 0.5 239 0.03 5.6 354 0.05 7.3 174 0.03 5.9 314 0.06 7.3 237 0.6 7.6 302 0.04 5.4 439 0.06 7.4 233 0.04 5.5 394 0.06 7.4 308 0.06 7.6 0.625 168 0.06 8.1 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 237 ] Roof Exhaust Performance and Dimensional Data XRED-090 and 095 - Direct Drive 213/4 (552) *145/8 (371) 13/4 (44) 17 (432) Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 26 lbs. (12 kg) cfm All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-090-E 1/40 1050 XRED-090-G 1/25 1300 XRED-090-D 1/15 1550 XRED-095-E 1/30 1050 XRED-095-G 1/12 1300 XRED-095-D 1/8 1550 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 520 0.01 4.0 644 0.03 5.4 768 0.05 7.6 717 0.03 5.4 888 0.06 7.6 1059 0.10 9.6 0.1 441 0.02 3.9 580 0.03 5.4 714 0.05 7.5 606 0.03 4.5 802 0.06 6.8 987 0.10 9.4 0.125 420 0.02 3.9 565 0.04 5.4 701 0.06 7.5 570 0.04 4.5 780 0.06 6.7 969 0.10 9.3 0.15 398 0.02 4.0 549 0.04 5.4 688 0.06 7.5 534 0.04 4.5 754 0.06 6.6 950 0.11 9.2 0.2 351 0.02 4.1 515 0.04 5.4 662 0.06 7.5 468 0.04 4.4 695 0.07 6.5 912 0.11 9.0 0.25 293 0.02 4.2 478 0.04 5.5 633 0.06 7.4 389 0.04 4.5 640 0.07 6.4 863 0.11 8.8 0.3 0.375 0.5 0.625 440 0.04 5.5 605 0.07 7.4 290 0.03 4.6 586 0.07 6.4 814 0.11 8.7 373 0.05 5.6 557 0.07 7.4 473 0.08 7.4 338 0.07 7.8 493 0.07 6.4 745 0.12 8.7 184 0.05 6.8 623 0.12 8.7 474 0.11 8.7 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 238 ] Roof Exhaust Performance and Dimensional Data XRED-101 and 121 - Direct Drive 245/8 (625) *20 (508) 13/4 (44) 19 (483) cfm Damper Size = 12 x 12 (304 x 304) Roof Opening = 141/2 x 141/2 (368 x 368) ^Approximate Unit Weight = 43 lbs. (20 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-101-C 1/8 860 XRED-101-B 1/6 1140 XRED-101-A 1/4 1725 XRED-121-C 1/8 860 XRED-121-B 1/6 1140 XRED-121-A 1/4 1725 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 766 0.02 4.3 1015 0.05 7.1 1536 0.17 12.1 922 0.03 5.6 1222 0.06 8.1 1849 0.22 14.1 0.1 625 0.03 4.2 917 0.06 7.0 1470 0.18 11.9 767 0.03 5.2 1107 0.07 7.9 1772 0.23 14.0 0.125 588 0.03 4.2 893 0.06 7.0 1454 0.19 11.8 723 0.04 5.2 1078 0.07 7.9 1753 0.24 13.9 0.25 0.3 0.375 0.5 0.625 0.75 747 0.06 6.8 1374 0.20 11.6 450 0.04 5.2 918 0.08 7.8 1659 0.25 13.8 683 0.06 6.8 1340 0.20 11.5 569 0.06 6.6 1277 0.20 11.3 1181 0.21 11.2 1086 0.22 11.3 974 0.22 11.7 848 0.09 7.8 1621 0.26 13.6 734 0.09 8.1 1560 0.27 13.4 335 0.07 9.8 1453 0.28 13.4 1341 0.29 13.4 1223 0.3 13.4 1 911 0.29 14.1 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 239 ] Roof Exhaust Performance and Dimensional Data XRED-131 and 141 - Direct Drive 287/8 (733) *20 (508) 13/4 (44) 22 (559) Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) ^Approximate Unit Weight = 59 lbs. (27 kg) cfm All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-131-C 1/8 860 XRED-131-B 1/6 1140 XRED-131-A 1/2 1725 XRED-141-C 1/8 860 XRED-141-B 1/6 1140 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 1193 0.04 6.5 1581 0.094 9.9 2393 0.325 19.2 1376 0.055 6.8 1824 0.129 10.4 0.1 1050 0.049 6.1 1482 0.105 9.8 2340 0.339 18.9 1205 0.064 6.6 1701 0.141 10.4 0.125 1011 0.051 6.0 1452 0.108 9.7 2327 0.342 18.9 1161 0.066 6.5 1667 0.144 10.3 0.25 771 0.056 5.9 1304 0.12 9.4 2225 0.366 18.4 919 0.074 6.4 1498 0.158 9.8 0.3 626 0.055 5.9 1239 0.123 9.2 2186 0.376 18.4 798 0.074 6.6 1425 0.163 9.5 0.375 0.5 0.625 0.75 1 1130 0.13 9.0 2127 0.389 18.2 489 0.063 8.0 1314 0.17 9.1 889 0.129 8.8 2030 0.407 18.1 1931 0.423 18.1 1817 0.426 17.8 1555 0.453 17.4 1113 0.175 8.7 794 0.158 8.4 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 240 ] Roof Exhaust Performance and Dimensional Data XRED-150 and 160 - Direct Drive 351/2 (902) *211/8 (537) 13/4 (44) 26 (660) Model XRED-150 Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) ^Approximate Unit Weight = 59 lbs. (27 kg) cfm 351/2 (902) *215/8 (549) 13/4 (44) 30 (762) Model XRED-160 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 81 lbs. (37 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-150-C 1/8 860 XRED-150-B 1/4 1140 XRED-160-C 1/8 860 XRED-160-B 1/3 1140 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 1772 0.09 7.9 2349 0.21 11.7 2008 0.10 8.0 2662 0.23 13.6 0.1 1598 0.09 7.8 2217 0.21 11.6 1828 0.11 7.7 2521 0.25 13.4 0.125 1553 0.10 7.8 2185 0.21 11.6 1784 0.12 7.7 2489 0.25 13.4 0.2 1415 0.12 7.5 2085 0.21 11.3 1637 0.13 7.5 2392 0.27 13.3 0.25 1304 0.12 7.4 2017 0.23 11.1 1535 0.13 7.4 2319 0.28 13.1 0.3 1194 0.13 7.5 1949 0.25 11.0 1421 0.13 7.3 2245 0.28 13.1 0.375 1005 0.13 7.7 1836 0.27 10.9 1230 0.14 7.3 2135 0.29 13.1 .5 .625 .75 1628 0.29 11.2 1397 0.29 11.8 1114 0.28 12.8 1933 0.31 12.9 1697 0.32 12.7 1411 0.32 12.6 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 241 ] Roof Exhaust Performance and Dimensional Data XRED-170 and 180 - Direct Drive 351/2 (902) *215/8 (549) 13/4 (44) 30 (762) Models XRED-170 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 81 lbs. (37 kg) cfm 351/2 (902) *223/4 (578) 13/4 (44) 30 (762) Model XRED-180 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 118 lbs. (54 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Static Pressure (in. wg) Fan RPM XRED-170-C 1/4 860 XRED-170-B 1/2 1140 XRED-180-C 1/3 860 XRED-180-B 3/4 1140 cfm Bhp sones cfm Bhp sones cfm Bhp sones cfm Bhp sones 0 2572 0.172 9.7 3409 0.4 16.3 3240 0.24 12.1 4295 0.559 19.5 0.1 2379 0.187 9.6 3263 0.421 16.2 3053 0.262 12.4 4156 0.589 19.4 0.125 2330 0.191 9.5 3227 0.426 16.2 3002 0.268 12.4 4121 0.596 19.4 0.25 2077 0.208 9.2 3043 0.45 16.1 2733 0.296 12.5 3933 0.634 19.3 0.3 1961 0.214 9.1 2969 0.46 16.1 2603 0.306 12.5 3855 0.649 19.5 0.375 1782 0.223 9.1 2857 0.473 16.1 2390 0.321 12.3 3731 0.671 19.7 0.5 1416 0.228 9.1 2647 0.494 16.1 1978 0.332 11.9 3509 0.707 19.8 0.625 0.75 1 2428 0.514 16.1 1438 0.316 11.9 3241 0.74 20 2181 0.532 16.1 1457 0.488 17.2 2971 0.771 20 2246 0.759 21 Performance certified is for installation Type A Free inlet, Free outlet. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A Free inlet fan sone levels. [ 242 ]
© Copyright 2026 Paperzz