Wallmount ClimateCab Protect and cool equipment in harsh environments NEMA-12 / IP52 Rated INSIDE A BLACK BOX CLIMATECAB Air conditioner (800BTU shown) WALLMOUNT CLIMATECAB Black Box Wallmount Climatecabs are engineered around a welded frame. 12mm holes are drilled in the rear panel corners for attachment to a wall. Front and rear rails offer depth adjustment to make them suitable for patch panels as well as equipment. Front rails are provided with the cabinet, rear rails are available on request. A gland plate is available on double hinged models to allow the sealed entry / exit of cables.. The standard gland plate runs the entire width of the cabinet on the base of the rear section Three different cooling options are available. >> Fan >> 800 BTU Air Conditioning >> 2000 BTU Air Conditioning Front and rear rail position is completely adjustable Cable Entry/ Exit through optional gland plate Strong Welded Steel Construction Lockable Front Door FEATURES OVERVIEW >> NEMA 12 rated for protection against falling dirt, circulating dust, lint debris, and splashing liquids in indoor environments. >> Includes 19” rails with M6 mounting holes. >> Scratch resistant safety glass window provides easy viewing. >> Fully welded body and door construction. >> Robust 12-gauge frame and 14 or 16 gauge sides and doors. >> Seamless door gaskets keep out dust and contaminants. >> GO GREEN – save energy and money by cooling only the cabinet rather than the whole room or IT centre. >> WARRANTY – Air conditioned cabinets: 1 year. When you need to install rackmount equipment in less-than-ideal environments or in areas without existing cooling infrastructure, ClimateCab NEMA 12 Wallmount Cabinets are your answer. Their self-contained cooling system keeps your equipment housed in ideal conditions in virtually any location. On the double-hinged models, the cabinet swings away from either a front or a rear door, enabling access to the rear of your equipment. Single-hinged models in which only the front door opens are also available. MODELS ClimateCab with 800BTU Air-Conditioning The AC models are perfect for harsh environments and remote locations without cooling infrastructure. Air-Conditioning units keep equipment cool even with temperatures up to 54.4oC. A closed-loop cooling system recirculates air in the cabinet and keeps outside air out, while an internal evaporator eliminates condensation. An 800 BTU conditioner can extract around 250W of heat – ideal for hubs, switches, and communincations equipment. ClimateCab with 2000BTU Air-Conditioning Designed to protect rackmount computers the 2000BTU ClimateCab is approximately 800mm Deep, and can extract over 600W of heat. ClimateCab with Fan Use the fan models in areas where you need protection from the elements, but temperature control is not a significant issue. Air filters on the bottom can be easily removed for cleaning without opening the cabinet. A pagoda style fan top provides protection from falling liquids and debris. Single or Double Hinged? Double hinged cabinets provide the convenience of easy access to the rear of the equipment mounted inside. 800 BTU, Double Hinged Air Conditioned cabinet. Approx 600mm H x 600mm W x 600mm D (excluding air conditioner) RMW 5110ACE or RMW5110ACGE Single Hinged Fan assisted cabinet. Approx 600mm H x 600mm W x 600mm D (excluding fan unit) RMW 5120FE 2000 BTU, Double Hinged Air Conditioned cabinet. Approx 600mm H x 600mm W x 800mm D (excluding air conditioner) RMW 5210ACE or RMW5210ACGE BUYER’S GUIDE Ten questions you should ask: What is the ambient external temperature? What is the desired internal temperature? How much energy does the equipment inside the cabinet consume (worst case)? How are cables going to enter ? How is the cabinet going to be mounted? Is there room for the front section to swing? What is the weight of the equipment? Will the equipment clear the edge of the rear section when open (double hinged?) Is there adequate room for air to flow around the air conditioner? SPECIFICATION Construction : Front Door: Back Door: Rack Units : Power : Weight Capacity: Rails: Body: Welded 14-gauge steel 14-gauge steel with safety glass 14-gauge steel 12U 115 or 230 VAC, 50–60 Hz 100 lb. (45.4 kg) to rails. M6 Front. M6 rear optional. Buyer’s Guide | Wallmount ClimateCab Hinge Single Double Double Single Double Double Single Double Exterior Height 61 cm 61 cm Cabinet Width 61 cm 61 cm Total Width 77 cm 77 cm Exterior Depth 61 cm 61 cm Rack Units 12U 12U Equipment Depth 53.8 cm 28.6 cm Weight Capacity 45.4 kg 45.4 kg Cooling Capacity 800 BTU (235W) 800 BTU (235W) 61cm 61 cm 89 cm 79cm 12U 45.4 kg 2000 BTU (600W) 61cm 61 cm 61 cm 61cm 12U 71.7 cm 41.4 cm 41.4 cm 53.8 cm 45.4 kg Fan/ Ambient Air Code RMW5130AC(E) RMW5110AC(E) RWM5110ACG(E) RMW5230AC(E) RMW5210AC(E) RMW5210ACG(E) RMW5120AF(E) RMW5100AF(E) Fan Cabinet Single Hinged RMW5120AFE 610mm 540 mm 610 mm 610 mm 610 mm 610 mm 610 mm Fan Cabinet Double Hinged RMW5100AF 610mm 138 mm 472 mm 402 mm 610 mm 610 mm 610 mm 610 mm 770mm 800 BTU Single Hinged RMW5130ACE 190 mm 610 mm 540 mm 160 mm 610 mm 610 mm 610 mm 610 mm 800 BTU Double Hinged RMW5110ACE RMW5110ACGE 770mm 254 mm 356 mm 190 mm 286 mm 160 mm 610 mm 610 mm 610 mm 610 mm 861mm 2000 BTU Single Hinged RMW5230ACE 254 mm 789 mm 717 mm 251 mm 610 mm 610 mm 610 mm 789 mm 2000 BTU Double Hinged RMW5210ACE RMW5210ACGE 861mm 305 mm 254 mm 251 mm 484 mm 414 mm 610 mm 610 mm 610 mm 789 mm PERFORMANCE 800 BTU PERFORMANCE 2000 BTU INSTALLATION AND MAINTENANCE INSTALLATION Climatecab sections can be separated to reduce the weight of the individual parts during installation. A typical process is as follows: • Mark and Install wall anchors. • Hang rear section and tighten wall anchors. • Hang air conditioner and tighten support bolts. • Adjust front rail depth. • Install rear rails if supplied. • Make cable entry/ exit by using gland plate or drilling/ installing individual cable glands. • Set desired internal temperature by turning the temperature trim control from inside the cabinet. • Connect to AC supply, test and readjust temperature. • Install equipment. MAINTENANCE ClimateCab air conditioners are sealed for life. There is no requirement to re-gas the system. A removable, washable Aluminium filter is accessible from outside the cabinet. SHELVES ACCESSORIES Rails European ClimateCab rails feature square holes to accept cage nuts and M6 mounting screws. A standard Climatecab includes a pair of front rails. A range of accessories are available for this cabinet series including: >> Additional Rails >> Earth Bonding Kit >> PDUs >> Cable Managers >> Cage Nuts and Screws >> Shelves Standard Shelves Standard shelves typically run the full depth of the cabinet and are mounted at the front and rear. Depending on the load requirement, shelves are of varying thicknesses which can take up “U” space in the cabinet. Cantilever shelves are for smaller lighter equipment and take up virtually no vertical “U” space. ADDITIONAL RAILS Rear rails allow the mounting of a rear PDU or can be used to distribute the weight of heavy items. They are suitable for use with double hinged Climatecabs. Item M6 Rear Rails (pair) Code RMW5RK SHELVES CANTILEVER SHELF A short ventilated shelf that saves U height. Cage nut fixings are included with each shelf. Max Load Bearing 15kg evenly spread. Item 1U 4.45 cm H 1U 4.45 cm H 2U 8.90 cm H 2U 8.90 cm H 20 cm D 30 cm D 30 cm D 40 cm D Code RKT12CSH RKT13CSH RKT23CSH RKT24CSH ACCESSORIES EARTH BONDING KIT Every door or panel on the Wallmount Climatecab is fitted with an earth bonding point. For regulatory compliance and to prevent the risk of an electric shock it is recommended that an earth bonding connection is made. Item Earth Bonding Kit Code RMW5EBK CAGE NUTS, SCREWS AND WASHERS 50 M6 Screws, Cage Nuts and Washers. Item 50x Cage Nuts/ Screws Code RAKCAGENUT50-SP POWER DISTRIBUTION UNITS PDUs UK Horizontal PDUs. See website or contact Black Box for metered or intelligent. Optional connectors include: BS1363 (UK) IEC C13, C14, C20, Commando Item UK Horizontal PDUs – BS1363 1U, 7-way 1U, 8-way 2U, 4-way 2U, 5-way 2U, 8-way Code PDUT/7H PDUT/8H PDUD13/4H PDUD13/5H PDUD13/8H BLACK BOX EXPLAINS CABLE MANAGEMENT Bend Radius You can invest in the best cable and hardware, but if it’s not installed properly, it won’t work, or at least it won’t work well. If you bend twisted-pair cable too much, you loosen the twists and lose performance. Protect your investment by adhering to the following bend radius recommendations under no-load conditions: HORIZONTAL CABLE MANAGERS Jumper ring panels are perfect for horizontal cable runs into patch panels. UTP horizontal: 4 X the cable diameter. ScTP horizontal: 8 X the cable diameter. Multipair backbone: 10 X the cable diameter. 2- and 4-fibre horizontal: Not less than 25mm. Fibre backbone: Not less than 10 times the cable diameter, or as recommended by the manufacturer. Even though there is no standard at this time for patch cable bend radius, it’s good to be aware of bend radius when using patch cables. Item Code 1U x 4-Loop Jumper Ring Panel RKT14JRP 2U x 4-Loop Jumper Ring Panel RKT24JRP CABLE RACEWAY A horizontal manager that features a cover plate for a more professional appearance. Item Code 1U Horizontal Raceway & Cover RMT100A-R3 2U Horizontal Raceway &Cover RMT102A-R3 BRUSH PANEL Brush panels provide an excellent method of concealing excess cable, or feeding cables into patch panels from behind. Item 1U Brush Panel 2U Brush Panel Code RKT1BRP RKT2BRP
© Copyright 2026 Paperzz