ENERGY CABLES Electric Utility Cables Paper Lead 1C 19/33kV, Copper APPLICATION In urban networks for primary supply to underground residential distribution substations. Main feeders to commercial and industrial projects. The lead sheath provides an earth fault capacity adequate for many installations although it is fixed and usually less than the equivalent XLPE copper wire screened cable. STANDARD VOLTAGE CONDUCTOR INSULATION SHEATH MAX. OPERATING TEMP. AS 1026:1992 BS 6480:1988 19000/33000V Compacted Annealed Copper Mass Impregnated (Non Draining) Paper PVC, 4V-75 or MDPE 65 °C TECHNICAL SPECIFICATIONS CONDUCTOR 2 OVERALL DIAMETER APPROXIMATE MASS MINIMUM BENDING RADIUS mm (No./mm) MINIMUM mm MAXIMUM mm MDPE Kg/Km PVC Kg/Km INSTALLED mm DURING INSTALLATION mm 50 70 95 120 150 185 240 300 400 500 630* 19 strands 19 strands 19 strands 19 strands 19 strands 37 strands 37 strands 37 strands 59 strands 60 strands 92 strands 29.9 31.7 33.2 35.2 36.3 38.2 41.2 43.8 47.2 50.6 55.7 31.5 33.4 35.0 37.1 38.3 40.2 43.3 46.1 49.6 53.1 58.4 2600 3000 3400 3800 4300 4800 5700 6600 7900 9500 11500 2800 3200 3600 4000 4400 4900 5900 6700 8000 9600 11900 630 670 700 750 770 810 870 930 1000 1070 1160 660 700 740 780 800 850 910 970 1040 1120 1210 *Conductor uncompacted. New Zealand/Energy/Electric Utility Cables/MV Paper Lead/Screened 33kV/1C, Copper │ VERSION: Lengths and packing can be supplied to customer’s requirements. For glanding details, contact your local service centre. Bending radii to BS 6480 TECHNICAL SPECIFICATIONS - Continued NOMINA L AREA mm² CURRENT RATING (a) ELECTRICAL CHARACTERISTICS Buried Direct Max. DC Resistance @ 20°C ohm/km Buried In Ducts (Trefoil) Max. AC Resistance @ 65°C ohm/km Inductance mH/km Equivalent Star Reactance ohm/km Capacitance µF/km 3 Phase Voltage Drop mV/A.m 1 Sec Fault Rating (b) 3 Phase Symmetrical kA 0.81 0.58 0.43 0.37 0.32 0.27 0.24 0.22 0.20 0.19 0.18 5.7 7.9 10.7 13.6 16.9 20.9 27.1 33.9 45.2 56.5 71.2 A A 50 184 176 0.379 0.446 0.452 0.142 0.230 70 222 212 0.262 0.309 0.426 0.134 0.259 95 264 251 0.195 0.230 0.402 0.126 0.292 120 300 285 0.150 0.177 0.385 0.121 0.320 150 340 320 0.122 0.144 0.370 0.116 0.356 185 381 358 0.0972 0.109 0.337 0.112 0.387 240 439 408 0.0740 0.0886 0.343 0.108 0.430 300 488 450 0.0590 0.0714 0.331 0.104 0.469 400 569 520 0.0461 0.0568 0.320 0.101 0.517 500 633 573 0.0366 0.0464 0.310 0.098 0.568 630 707 634 0.0283 0.0376 0.299 0.094 0.632 (a) Based on 65°C maximum conductor temperature, burial depth of 0.8m, soil temperature of 15°C and thermal resistivity of 1.2°Cm/W. (b) For fault durations other than one second, divide the appropriate given value by the square root of the required time (in seconds). Conductor fault ratings are based on an initial temperature of 65°C and a final temperature of 150°C. CONDUCTOR NOMINAL AREA mm2 NOMINAL DIAMETER mm LEAD ALLOY SHEATH MIN. INSULATION BETWEEN CONDUCTOR & SHEATH mm MINIMUM THICKNESS mm DIAMETER OVER SHEATH MINIMUM MAXIMUM mm mm NOMINAL AREA mm² 50 8.1 7.3 1.5 27.1 28.6 130 70 9.8 7.3 1.5 28.9 30.5 139 95 11.4 7.1 1.6 30.4 32.1 156 120 12.9 7.1 1.6 32.2 33.9 166 150 14.3 6.8 1.7 33.3 35.1 182 185 16.0 6.8 1.7 35.2 37.1 193 240 18.4 6.8 1.8 38.0 40.0 220 300 20.3 6.8 1.8 40.4 42.5 235 400 23.5 6.8 1.8 43.6 45.8 254 500 26.6 6.8 2.0 47.0 49.3 304 630 32.7 6.8 2.1 51.1 53.7 348 (c) For fault durations other than one second, divide the appropriate given value by the square root of the required time (in seconds). 1 SEC FAULT RATING (c) kA 3.9 4.2 4.7 5.0 5.5 5.9 6.7 7.1 7.7 9.2 10.5 Sheath fault ratings are based on an initial temperature of 55°C and a final temperature of 250°C. GENERAL CABLE NEW ZEALAND LIMITED 75 – 89 Main South Road Riccarton, Christchurch PO Box 8044, Riccarton, Christchurch, New Zealand Phone: 0800 CABLES (0800 222 537) FAX: 0800 242 267 EMAIL: [email protected] New Zealand/Energy/Electric Utility Cables/MV Paper Lead/Screened 33kV/1C, Copper │ VERSION: 1C Copper v050412
© Copyright 2026 Paperzz