- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Categorization of Disturbances Transients Short Duration Variations < 1/2 cycle 0 1/2 cycle - 1 min. Oscillatory Transient > 1minute. 1 minute. 1/2 cycle Impulse Transient Long Duration Variations Instantaneous swell/sag/interruption. Over/under voltage Interruption 1/2 - 30 cycle Momentary swell/sag/interruption 30 cycle - 3sec Temporary swell/sag/interruption. 3sec - 1minute. > 1minute. Categories Transients Impulsive Nanosecond Microsecond Millisecond Oscillatory Low Frequency Medium Frequency High Frequency Typical Spectral Content 5 s rise 1 μs rise Typical Duration Typical Voltage Magnitude 0.1 ms rise < 50 s 50 s -1 ms > 1 ms < 5 kHz 5 - 500 kHz 0.5 - 5 MHz 0.3 - 50 ms 20 μs 5 μs 0 - 4 per-unit 0 - 8 per-unit 0 - 4 per-unit 0.5 - 30 cycles 0.5 - 30 cycles 0.1 - 0.9 per-unit 1.1 - 1.8 per-unit 0.5 cycles - 3 sec 30 cycles - 3 sec 30 cycles - 3 sec < 0.1 per-unit 0.1 - 0.9 per-unit 1.1 - 1.4 per-unit 3 sec - 1 min 3 sec - 1 min 3 sec - 1 min < 0.1 per-unit 0.1 - 0.9 per-unit 1.1 - 1.2 per-unit Long Duration RMS Variations Interruption, Sustained Undervoltages Overvoltages Current Overload > > > > 0.0 per-unit 0.8 - 0.9 per-unit 1.1 - 1.2 per-unit Voltage Imbalance Current Imbalance Steady-state Steady-state 0.5 - 2% 1.0 - 30% Waveform Distortion DC Offset Harmonics Interharmonics Notching Noise 0 - 9 kHz 0 - 9 kHz 0 - 0.1% 0 - 20% 0 - 2% Broadband Steady-state Steady-state Steady-state Steady-state Steady-state Voltage Fluctuations < 25 Hz Intermittent 0.1-7%, 0.2-2 Pst < 10 sec ± 0.10 Hz Short Duration RMS Variations Instantaneous Sag Swell Momentary Interruption Sag Swell Temporary Interruption Sag Swell Power Frequency Variations 1 1 1 1 minute minute minute minute 0 - 1% Customer Contact Information: Company: ___________________________________________________ Address: ___________________________________________________ Contact Name: ___________________________________________________ Phone Number: ___________________________________________________ Fax Number: ___________________________________________________ E-mail Address: ___________________________________________________ Equipment or Process Affected: Equipment Type: _____________________________________________ Manufacturer: _____________________________________________ Equipment Rating: _____________________________________________ Mitigation Equipment: _____________________________________________ Symptoms (√ all): □ Error/Fault Code □ Control Problem □ Dimming Lights □ Breaker Tripping □ Equipment Overheating □ Equipment Damage □ Harmonic Problem □ Capacitor Bank Failure □ Other □ UPS Beeping □ Short Power Loss □ Drives/PLC Tripping Other Details: _________________________________________________________ Disturbance Information: Date: ___________________________________________________________ Time: ___________________________________________________________ Event Description: _______________________________________________ _______________________________________________ Weather Conditions: _______________________________________________ Duration (√): < 2 seconds Regularity (√): Daily □ □ Hourly 2-120 seconds □ Weekly □ □ > 2minutes > Unknown □ > Unknown □ Lost Production Time (hrs): ____________________________ _____________________________ Additional Comments: ______________________________________________ ______________________________________________ □
© Copyright 2026 Paperzz