HWEa ® FARLINE Total system for perimeter wall installation with integrated electrical trunking FARLINE • FARLINE HWBa offers the same total solution as HWAa with cooling, heating and ventilation but is equipped with the Stifab Farex integrate distribution system for electrical, data, alarm and telecommunications cables. • Using FARLINE you maintain full flexibility with regard to interior wall positioning. HWEa • The FARLINE system has a large capacity despite its compact size. FUNCTIONS – Ventilation – Cooling – Heating – Integrated room temperature control – Integrated electrical trunking – Integrated socket panel for connectors – Casings – Approved to supply several fire compartments APPLICATIONS New building, extension and refurbishment of: – Offices – Conference rooms – Hotels KEY FIGURES Cooling effect: 1279 W (L= 1600 mm, ∆t mk = 10°C, q = 45 l/s). l Heating effect: 1958 W (L= 1600 mm, ∆tmk= 30°C). Air flow: 10 to 45 l/s. Pressure array: 150 - 300 Pa. Lengths: 800, 1000, 1300 and 1600 mm. Height: 500, 550, 650 and 700 mm. Ducting dimensions: Ø160, Ø200 mm. Control: Integrated system control equipment for sequential control per room. The product is patent pending We reserve the right to change the technical specification. Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se 153 HWEa ADVANTAGES OF FARLINE HWBa • In addition to the fact that Stifab Farex perimeter system FARLINE HWBa, as FARLINE HWAa, is a total solution for cooling, heating, ventilation and control, FARLINE HWBa also offers an integrated electrical trunking solution. • It can be supplied in a screened design with aluminium ducting which is connected to a cable shelf, folding cover and front casing panel for earthing. Function + - • Vertical connection of plugs allows more options for furnishing along the perimeter wall without connectors and sockets being concealed. Excess cables can be collected inside the folding cover. • As with the Stifab Farex perimeter wall system FARLINE HWAa all components are prefabricated and matched for installation by a contractor – giving short attendance times and a minimum of coordination with other contractors. Cooling FARLINE HWE FARLINE HWE is a perimeter wall unit with the functions cooling, heating, ventilation and electrical trunking. Installation Neutral Heating Air terminal with folding cover Installation: The units are suspended on an assembly rail and the prefabricated pipe and electrical trunking are positioned once the units are fixed to the wall. Hinge at the back Connection: Connection pipes, pipe stops and ducting covers are fitted at the start and end of a unit branch. Control equipment: The connection cable is connected to snap-in terminals on the unit’s connection card and is routed on to the adjacent unit. The transformer is suspended on a wall rail and is connected to the connection card, number as required. Casing: Perimeter casing and supply air grille are fitted in position after which the room regulator is connected to the snap-in terminals on the unit’s connection card. Socket panel with strain relief Cable channel Electrical trunking System solution with casing Topline YMC and folding cover (see separate section YMC). RANGE AVAILABLE ON ORDER Perimeter unit with cooling, heating and ventilation. Factory fitted valves, actuator, connection card and cable shelf with socket panel and support for electrical trunking. Length: 800, 1000, 1300 and 1600 mm. Height: 650 mm with duct size Ø160 mm and 700 mm with duct size Ø200 mm. Ducting dimensions:Ø160 mm or Ø200 mm. Pressure range: 1 = Up to 150 Pa 2 = 160 - 300 Pa Air flow for respective pressure ranges, see separate brochure HWD. 154 FARLINE HWE Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se ACCESSORIES HWE The accessories listed below are unique to FARLINE HWBa. Accessories Connection set HWET AR Contains end cover, connection pipes, terminating pipes with venting nipples pipe brackets and cable entries. Coupling pipe set HWET SP Coupling pipe set for joining heating, cooling and supply air between units. Electrical trunking is available in either ABS plastic or aluminium. Wall block HWET VF Sound dampening prefabricated wall block for fixed or interior walls. Loose end section HWET LG End sections in either right or left-hand designs with the same dimensions as the FARLINE end sections. HWDT AR HWET SP HWET VF Insert unit HWET IP Loose cable shelf with socket panel and two loose end sections for freestanding installation between two units. Units are available in lengths 800, 1000, 1300 and 1600 mm and have the same outside dimensions as FARLINE HWE. HWDT AR HWDT MS Electrical trunking HWET EK 1 x pipe Ø40 mm in ABS-plastic or aluminium. Casing TOPLINE YMCa A presentation of the casing and folding cover can be found in the brochure TOPLINE YMC. TECHNICAL SPECIFICATION Cooling effect & pressure drop data The air’s cooling effect & sound data. Heating effect water & pressure drop data. For technical data refer to the section in the brochure HWD: Control: See separate section in the brochure water based climate systems. Insert unit HWET IP HWEa Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se 155 HWEa DIMENSIONS Length HWE Nominal measurements HWE: 220 800, 1000, 1300 and 1600 mm Length HWE: Nominal - 10 mm. Outlet sleeve internally: Nominal - 235 mm. 180 140 60 Ø8 123 172 Ø40 Outlet sleeve 135 700 90 25 74 348 Ø25 500 Ø8 260 (View: end) HWE duct dimension 200 mm Length 58 (View: front) Socket panel, L 220 180 140 60 Ø8 123 172 Ø40 650 74 25 348 Ø25 240 95 30 215 450 Ø8 Ø160 90 220 (View: end) HWE duct dimension 160 mm 156 Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se 290 265 119 120 110 Ø200 60 180 270 30 SPECIFICATION Perimeter unit system type FARLINE HWBa for cooling, heating and ventilation and electrical trunking. The system shall comprise Stifab Farex room control equipment and essential accessories for connection of pipes and the air supply. Each unit shall be supplied with a preset prescribed air flow. The Stifab Farex delivery shall include all material for each unit branch shown on the drawings for the physical limit of contract. Wall penetration shall be carried out using Stifab Farex wall block VF-1, Stifab Farex wall penetration VF-2 built on site or any other method as set out on the drawing. Carried out by VE or another contactor. Stifab Farex casing Topline YMCa as set out in the drawing shall be carried out by VE or another contractor. Limits of contract Stifab Farex’s limits of contract are the connection points for water (according to the figure under Project planning – Contractor – Physical limits of contract on page 141). At these connection points RE connects to plain pipe ends, fills the system, vents and carries out a pressure test. VE connects to the duct connections with dimensions as set out on the basic size drawing under the section “Dimensions”. EE provides an earthed 230 V socket for each transformer and a fitted connection box for each thermostat. EE supplies and installs requisite sockets for electricity, data, telecom and route cables. BE makes the cut outs in interior walls and soundproofs as per the drawings. Specification Product FARLINE HWE aaa - bbb - bbb - c - ddd - ee Length: 800, 1000, 1300 and 1600 mm HWET SP - a - bbbb - cccc Type: 1= Electrical trunking of ABS-plastic. 2= Electrical trunking of aluminium Ducting dimensions: 160, 200 mm or 1620 (adapter Ø200 to Ø160 mm) Length: According to the specification within the range 300 ≤ L ≤ 5000 mm. Control cables order separately according to the specification in brochure RWB. If these are to be included state the cable type and length. Loose ends HWDT LG - a - bbb-bbb Design: V= left H= right Ducting dimension and height (mm): Ø160 - 650 or Ø200 - 700 HWET VF - a - bbb-bbb - ddd Wall penetration Design: 1= wall block 2= wall penetration built on site EI60 Ducting dimension and height (mm): Ø160 - 650 or Ø200 - 700 Thickness: 100, 150 mm. (VF-2 only t=150 mm) Height and ducting dimension (mm): 650 - 160, 500 -160, 550 - 200 or 700 - 200 Insert set HWET IP - aaa - bbb Ducting dimensions: 160, 200 mm. Pressure range: Length: 1 = Nozzles for pressure up to 150 Pa 800, 1000 1300 and 1600 mm. Electrical trunking Drive pressure: State the required pressure 150 – 300 Pa HWEa 2 = Nozzles for pressure up to 160 – 300 Pa Air flow rate: State the required air flow rate as set out in tables 1-4 Jointing pipe set HWET EK - a - bbbb Type: 1= ABS-plastic 2= Aluminium Length: According to the specification within the range 300 ≤ L ≤ 5000 mm. Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se 157 HWEa 158 Stifab Farex Indoor climate systems 2000 - 2002 www.stifarex.se
© Copyright 2025 Paperzz