A New Era in High Speed Analysis with Dynamic MRM and UHPLC Tim Schlabach, Marketing Anabel Fandino, Ph.D., R&D PeteStone, Ph.D., Marketing Page 1 Agilent LC/MS, GC/MS, and ICP-MS Products Page 2 Page 2 ASMS Training Agilent LC/MS, GC/MS, and ICP-MS Products Page 3 Page 3 ASMS Training Agilent 1290 Infinity LC Attributes for MS - Infinitely Better for LC/MS High Pressures Page 4 1200bar @ 2mL/min for highest resolution Reduced Ion & Matrix Suppression Low Delay Vol. Less than 100 uL delay volumes First peaks can elute in < 6 seconds High Throughput HT-Solution for up to 2,000 samples/day Complete System Integration MassHunter Agilent 6000 Series LC/MS: Speed for UHPLC Fast MRMs for UHPLC 1 ms dwell for MRM 30 ms Pos/Neg Switching > 200 MRMs/ sec Agilent 6460 Best Data Quality Fast Scans for UHPLC Agilent 6530 Page 5 40 MS Scans/sec 10 MS/MS scans/sec 1290 Infinity LC means fast peaks, < 3 seconds Page 6 Fast MRMs with 6400 Series QQQ – metabolism polarity switching in 30 millisecs plus 6 transitions (2 ISTDs) Avg W1/2 = 0.71 sec 15 points across Verapamil, 0.75 min RSD [%] = 2.9 Avg W1/2 = 1.3 sec 35 points across Buspirone, 0.40 min RSD [%] = 1.8 Dextromethorphan, 0.53 min Avg W1/2 = 0.52 sec 11 points across RSD [%] = 6.5 Avg W1/2 = 1.3 sec 35 points across RSD [%] = 2.7 Diclofenac, 1.04 min Peaks widths with UHPLC only 2 seconds or less > ten uniform measurements across peak REQUIRED Verapamil, peak RSD 5% Avg. W1/2 = 0.72 sec W = 2.1 sec Cycle time < 115 ms Page 8 Peak Capacities are very high with UHPLC 40 Extracted Ion Transitions in 1 minute Page 9 Dynamic MRM for 6400 Series Triple Quads monitors ion transitions only when compounds elute Cycle Time: Concurrent MRMs Dwell Time: With DMRM the number of concurrent MRMs are fewer than with Time Segments Page 10 Analysis of 600 Pesticide DMRM Transitions in 15 min. Agilent 1290 Infinity LC + 6460 Triple Quad 9 replicates analyzed at 200 pg level Mean area %RSD = 3.2 Page 11 1290/6230 Accurate Mass TOF Pesticide Screening 250 pesticides, 50 pg on column 17 min. 3 min. Most peaks 1-2 seconds wide! 1.5 min. The Need for Speed in UHPLC/MS/MS Cycle Times (MRM): <150 milliseconds Dwell Times (MRM or DMRM): <= 2 millliseconds Polarity Switching (MRM): < 50 milliseconds Spectral scans: at 5 Hz or faster PPM Mass Accuracy: at 5 Hz 20 K Resolution: at 5 Hz Page 13 Agilent LC/MS can meet your most demanding application needs. The ultimate Qual solution 1290 Infinity LC and 6530 Accurate Mass Q-TOF MS The ultimate Quant solution 1290 Infinity LC and 6460 Triple Quad MS Page 14
© Copyright 2024 Paperzz