of FENCE LOCATION 1 2 800

Approach Slab
Bridge
Gutter Transition
Locate Fence Along Slope Where
Top Of Fence Approx. Equals
Tops Of Headwall.
3 Strands Barbed Wire
3
8"
Expansion Or Chemical Concrete
Anchor Eyebolt Or Studs And Eyenuts.
1
2"
Embedment 2
Slope Pavement
Min. (3 Reqd.)
This Post To Be Located Approx. In Line
Terminate Fence Where Culvert
With End Bent. Set Post At Edge Of
Wing Height Approx. Equals
Slope Pavement.
Fence Height
Toe Of Slope
Varies, As Directed By The Engineer
Proposed Fence
Proposed Fence
6"
LA R/W Line
PLAN
PICTORIAL VIEW
Shoulder Line
Slope Pavement
Proposed Fence
Toe Of Slope
Natural Ground
Construct Flush Against Footing
3' Min.
ELEVATION
FENCING TERMINALS AT BRIDGE ENDS
Fence Locations At Cross Drains
With Excavated Outfall Ditches
(ROADWAY)
30°
Or As Shown In Plans.
PLAN
(For Heights Of Headwall Greater Than 4')
Bridge
Approach Slab
FENCING TERMINALS AT BOX CULVERTS
Shoulder Line
Gutter Transition
20'M in.
14' Max.
Proposed Fence
Natural Ground
Toe Of Slope
FENCING DETAIL AT CULVERT
Proposed Fence
8:
39:
27 AM
(For Heights Of Headwalls 4' Or Less.)
LA R/W Line
6"
PLAN
ELEVATION
Note: When height of headwall is 4' or less
(drainage pipe 36" or less) the fence
FENCING TERMINALS AT BRIDGE ENDS
shall not be tied to the headwall, but shall
6/9/2015
span the lateral ditch.
LAST
REVISION
07/01/05
REVISIO N
(STREAM CROSSING)
DESCRIPTION:
INDEX
2016
DESIGN STANDARDS
FENCE LOCATION
NO.
800
SHEET
NO.
1of 2
6'
10'
300'M in.
End LA R/W Line & Fence
NOTE: LA R/W along the crossroad will extend a minimum
300' beyond the end of the acceleration or deceleration
taper, with the taper most remote from the project
establishing the end for both sides of the roadway. In the
absence of a taper the radius point of the ramp return will
be used with the above criteria.
For interchange quadrants having no ramp the LA R/W
will extend along the crossroad to a point opposite the
limit of LA R/W established by the ramp taper or
� Cross Street
INSET A
radius point as noted above.
50' Min. Overlap
30' Min.
� Crossroad
See Inset A
6"
LA R/W Line
Local
Sidewalk
Street
LA R/W Line
45°
See Note B
Fence Type "B"
6"
Ramp
Fence Type "B"
6"
6"
Bridge Over Crossroad
50' Min. Overlap
45°
See Note A
Ramp
6"
Fence Type "B"
Radius Point
Varies
LA R/W Line
Note A - The indicated distance shall be sufficient to provide satisfactory
End LA R/W Line & Fence
sight distance for the traffic from the ramp.
See Note Above
100'M in.
6"
Fence
Note B - The indicated distance shall be identical to the above noted
APPLIES TO BRIDGE OVER CROSSROAD AND CROSSROAD OVER FREEWAY (BRIDGE OVER CROSSROAD SHOWN)
dimension, if practical.
End Fence &
LA R/W Line
FENCING TERMINALS AT RURAL INTERCHANGES
FENCING TERMINALS AT URBAN INTERCHANGES
6" Where Footing Permits
Varies
Retaining Wall
Varies
Fence
LA R/W Line
PLAN
Terminate Fence Where Wall Height
8:
39:
28 AM
Approximately Equals Fence Height.
Ground Line
6/9/2015
ELEVATION
LAST
REVISION
07/01/05
REVISIO N
FENCING TERMINALS AT RETAINING WALLS
DESCRIPTION:
INDEX
2016
DESIGN STANDARDS
FENCE LOCATION
NO.
800
SHEET
NO.
2 of 2