OPEN CARE WARMER OCW 100 INTENSIVE EFFICIENT ECONOMIC Total Maternal and Infant Care SUPREME convenience TOTAL comfort OPEN CARE WARMER OCW100 The OCW 100 is a superior radiant warmer at an economic price. Its rugged design gives it an extended operational life. The warmer unit of the OCW 100 may be operated in manual and servo modes. The heater cuts off automatically at 39°C. The large bassinet, together with the unique side-positioned pillar, provides all-round access to the infant. The bed may be tilted continuously to any desired position. The tilting mechanism is spring dampened, preventing the bed from falling down too quickly to the resting position. The OCW 100 is mounted on castors. Its legs are spread out for convenience and mechanical stability. They are specifically designed to avoid the legs of care-givers and visitors. Accessories and essentials may be stored in the shelf and drawer. Other features of the OCW 100 include two-position instrument trays and the facility to introduce X-ray cassettes without disturbing the infant. The warmer unit swivels to accommodate the X-ray unit. An examination lamp is provided for observation of the infant. An extra lamp may be provided optionally. The OCW 100 is easy to operate. It has separate displays for the set temperature and the actual skin temperature. The highly sensitive thermistor probe needs no calibration. The equipment is suitable for all environments from the labour room to the NICU. The trendy looks and styling of the OCW 100 go well with any hospital interior. The OCW100 is backed by the many years of experience has in designing and supplying sophisticated neonatal care equipment worldwide. OXYGEN HOOD Cat. No: 7.2.3-06/02/23 Aug’10 ACCESSORIES RESUSCITATION BAG endeavours to meet your every need. If your practice has any special requirement, call the R&D department . They will be happy to provide you a solution. at A11805 ISO 13485:2003 4426 RT : D THE CL O UN O PO SERVICE SUP CK Your nearest distributor: Phoenix Medical Systems Private Limited No. 32/4, Jawaharlal Nehru Salai, Ekkattuthangal, Chennai 600 097, India. Tel.: 91-44-2225 1177, 2225 1178 Fax : 91-44-2225 0194 : [email protected] : phoenixmedicalsystems.com R OPEN CARE WARMER OPEN CARE WARMER OCW100 Technical Specifications Heat Source Quartz encapsulated 600w or 500w Heater placed in a parabolic reflector Heater module can be swiveled to 65° C Heater power can be adjustable from 0-100% with 20% increments Set Temperature range in SERVO mode 32° C to 38° C 15 to 40° C ±0.2° C ±0.1° C ±0.2° C (Requires no field Calibration) Display Infant Temperature : Bright 1” Numerical LED Display Set Temperature : Bright 0.5” Numerical LED Display Audio and Visual Alarm Indications Low Temp: When infant temperature falls below set temperature by 0.5° C High Temp: When infant temperature raises above set temperature by 0.5° C Probe Failure: Probe short / probe disconnection System Failure (with Heater Cut off) Power Down: If heater power is greater than 60% in MANUAL mode for more than 15mins Heater Fail Power Fail (Optional) Manual mode alert alarm (every 15 minutes) Electronic Salient Features Key Lock Facility prevents accidental change of settings Alarm Mute Facility for low critical alarms Examination Lamp - 50 Watt (Halogen Lamp with >0.1Lumens /cm2) Can be operated in MANUAL and SERVO Mode PWM based heater power control with Zero Cross Detection Over temperature protection Automatic cutoff of heater at 40° C Electrical Specification Operating Voltage* : 230v AC~, 50 Hz Power consumption Fuse Heater Overload protection Leakage current Earth resistance Low Noise RT : D THE CL O UN O 800w/3.4A 800w/7A 4A 8A Single element quartz infrared heater at 4A <0.5mA <0.2 : : : : : Class 1 Type B Continuous Not protected Not protected Physical Dimension and Weight: Length : 116 cm (45.5”) Width : 76 cm (30”) Height : 196 cm (77”) Bassinet : 83(L) x 52(W) cm Mattress : 81(L) x 50(W) x 5 cm Mattress distance from ground level : 98 cm : 50 kg ENVIRONMENTAL SPECIFICATIONS Operating: Temperature Range : 18° C to 30° C Relative humidity Range : 10% to 75% RH Atmospheric pressure : 700 to 1060 hPa Coating Epoxy / powder coated body for scratch protection and rust prevention ERVICE SU P PO S CK : : : : : : Electrical Protection Type of protection against electric shock Degree of protection against electric shock Mode of Operation Protection against hazards of explosion Protection against ingress of liquids Weight Mechanical Salient Features Easily Movable 4” (100mm) lockable castors Tray for placements of monitoring devices Mattress with high quality foam Drawers for keeping patient records IV Pole (Adjustable Optional) Easy accessible side door panels 10° bed tilting(Trendelenburg or Reverse Trendelenburg) continuously variable 110v AC~, 60Hz (*Refer rating plate on the equipment) Cat. No: 7.2.3-06/02/23 Aug’10 Temperature Probe Range : Accuracy : Resolution : Probe Interchangeability : Your nearest distributor: A11805 ISO 13485:2003 4426 Phoenix Medical Systems Private Limited No.32/4, Jawaharlal Nehru Salai, Ekkattuthangal, P.O. Box 3205. Chennai - 600 097, India. Tel.:91-44-2225 1177, 2225 1178 Fax : 91-44-2225 0194. E-mail : [email protected] Website:www.phoenixmedicalsystems.com R
© Copyright 2026 Paperzz