Q-252 SVE BULLETIN SPECIAL VEHICLE ENGINEERING – BODY BUILDERS ADVISORY SERVICE E-Mail via Website: www.fleet.ford.com/truckbbas (click "Contact Us") Toll-free: (877) 840-4338 Date: 08 August, 2016 QVM Bulletin: Q-252 2017 and later F-Series Super Duty Upfitter Switches Models Affected: 2017 to present model year F-250/350/450/550 Super Duty Trucks with optional Upfitter Switches Description: The Ford Upfitter Switches are optional overhead console mount switches (Option Code 66S) that control under hood mounted relays. These relays power six blunt cut wires that are taped on a harness near the upfitter auxiliary relay box that can be found on the driver’s side of the engine compartment. The six blunt cut wires are as follows: Switches Aux 1 Aux 2 Aux 3 Aux 4 Aux 5 Aux 6 Circuit CB117 CB114 CB116 CB113 CB115 CB118 Color Brown / Green Violet / Orange Blue / Green Gray / Brown Brown / Blue Gray / Orange Fuse # F10 F9 F8 F7 F1 F2 Rating 25A 25A 25A 25A 40A 40A In addition to the upfitter switch blunt cut wires, this bundle contains the following blunt cut circuits: Description Run/ Start Output Battery Hot Output PTO Relay Control PTO Relay Output Circuit CB111 SB106 CE924 CB112 Color Brown Brown / Red Blue / Green Green / White Fuse # F3 F6 N/A F5 Rating 20A 20A N/A 25A All relays and fuses are located in the upfitter relay box. Figure 1: 2017 Super Duty Upfitter switch location NOTE: Upfitter Switches cannot be added to a vehicle that was not built with this option at production. Originator: BBAS Document: SVE Bulletin No. Q-252 Date Issued: 08/08/16 Page 1 of 5 To find the bunt cut wires: 1. Open Hood 2. Locate the relay pack on the Left hand side (driver’s side) of the engine compartment (see Fig. 2). 3. Locate bundle of 10 blunt cut wires with shrink wrap on the harness near the relay pack. Upfitter Relay Box & blunt cut circuit access Figure 2: Upfitter Relay Box and upfitter switch blunt cut output location. Accessing blunt cuts wires: On vehicles with dual batteries, removing the upfitter relay box will provide additional access to the blunt cut wires. 1. Disconnect the electrical connector. 2. Release tabs and lift upwards to remove. To reinstall upfitter relay box: 1. To install, reverse the removal procedure. Configuring Upfitter Switches 5 and 6 to Hot-at-all times. Upfitter relay box fuse F4 (5A) can be put into one of two positions. In Position A, auxiliary switch 5 and 6, operate with the ignition in RUN or START. In Position C, auxiliary switch 5 and 6 operate hot at all times. The following procedure describes how to configure #5 and #6 upfitter switches to Battery hot. 1. 2. 3. 4. 5. Remove upfitter relay box cover. Remove 5 Amp fuse located on the lower right hand corner of the upfitter relay box. Slide the contact guard from position A (left) to position C (right) position. Re-insert 5 Amp fuse into position C (right) position. Replace relay box cover. Fuse F4 Figure 3: Fuse F4 location Originator: BBAS Document: SVE Bulletin No. Q-252 Date Issued: 08/08/16 Page 2 of 5 Wiring Schematics Hot in Run or Start Hot at all times BATTERY JUNCTION BOX (BJB) 11-1 F4 C UPFITTER RELAY BOX 11-6 151-16 F4 A 5A 13-10 13-10 NOTE: Either F4-A or F4-C can be installed but not both at the same time. Upfitter relay box shipped with fuse in AUX F4A position. GN-OG C3271A S208 CBP22 GN-OG CBP22 BU-RD 1 23 C2280C C315 - 12 S352 CBP22 GN-OG 1 C9805 GN-OG C1617C BODY CONTROL MODULE (BCM) 11-4 F22 5A 13-19 CBP22 1 SBF03 MEGA 200A 13-10 11 C9120 SB104 GN-RD UPFITTER SWITCH 151-16 5 C315 SB104 GN-RD C9805- 8 C9120 YE-OG CAC13 BU-OG CAC08 BN CAC07 VT-GN CAC06 2 3 F 7 E 10 D 4 9 C 4 B 3 C9120 BK 6 GD233 10 12 C9805 A 140-11 140-11 140-11 140-10 140-10 140-10 GD233 BK 9 YE 8 GN-BN CAC05 7 CAC14 5 TO UPFITTER RELAY BOX G201 10-12 Hot in Run or Start BODY CONTROL F22 MODULE (BCM) 5A 11-4 13-19 Hot at all times BATTERY JUNCTION MEGA BOX (BJB) 200A 11-1 13-10 CBP22 SBF03 BU-RD C315 - 12 S352 CBP22 GN-OG CBP22 GN-OG GN-OG 23 C2280C 1 C1617C S208 CBP22 GN-OG 1 C3271A 2 GD233 BK SB106 BN-RD NOTE: Either F4-A or F4-C can be installed but not both at the same time. Upfitter relay box shipped with fuse in AUX F4A position. 3 UPFITTER RUN/START RELAY 1 F3 25A 13-10 5 SB103 BU-RD 3 2 UPFITTER RELAY BOX 11-6 151-16 UPFITTER PTO RELAY F5 25A 13-10 5 CB112 GN-WH 1 F6 20A 13-10 CE924 BU-GN 13-10 F4 A 5A 13-10 CB111 BN F4 C SB105 GY-RD S353 1 C315 GD233 BK CUSTOMER ACCESS located behind upfitter relay box Hot at all times CUSTOMER ACCESS located behind upfitter relay box Hot in Start or Run CUSTOMER ACCESS located behind upfitter relay box G201 10-12 Originator: BBAS Document: SVE Bulletin No. Q-252 Date Issued: 08/08/16 Page 3 of 5 Wiring Schematics (Cont.) TO UPFITTER SWITCHES Hot at all times BATTERY JUNCTION MEGA BOX (BJB) 200A 11-1 140-8 13-10 A 140-8 140-8 B C 3 CAC07 VT-GN 2 1 F9 25A 13-10 5 GD233 BK SB110 YE-RD GD233 BK UPFITTER RELAY 2 3 CUSTOMER ACCESS located behind upfitter relay box 3 2 UPFITTER RELAY BOX 11-6 151-16 UPFITTER RELAY 3 F8 25A 13-10 5 CUSTOMER ACCESS located behind upfitter relay box SB108 VT-RD 5 CB117 BN-GN 2 1 F10 25A 13-10 CB116 BU-GN UPFITTER RELAY 1 3 SB109 RD 1 C315 GD233 BK CAC05 YE 1 C3271A 9 CAC06 GN-BN 6 CB114 VT-OG SBF03 BU-RD 1 C1617C CUSTOMER ACCESS located behind upfitter relay box GD233 BK S353 GD233 BK GD233 BK 1 C315 G201 10-12 Hot at all times MEGA 200A 13-10 140-8 140-8 D E F 10 CAC13 BU-OG CAC14 YE-OG CUSTOMER ACCESS located behind upfitter relay box 1 F1 40A 13-10 5 CUSTOMER ACCESS located behind upfitter relay box 3 2 UPFITTER RELAY BOX 11-6 151-16 UPFITTER RELAY 6 F2 40A 13-10 5 CB118 GY-OG 2 UPFITTER RELAY 5 GD233 BK 3 SB101 RD GD233 BK 1 F7 25A 13-10 5 CB113 GY-BN 2 UPFITTER RELAY 4 CB115 BN-BU 3 GD233 BK 1 C315 SB102 YE-RD 11 SB107 WH-RD C3271A 4 CAC08 BN 1 140-8 C1617C SBF03 BU-RD 1 TO UPFITTER SWITCHES BATTERY JUNCTION BOX (BJB) 11-1 CUSTOMER ACCESS located behind upfitter relay box GD233 BK S353 GD233 BK BK GD233 1 C315 G201 10-12 Originator: BBAS Document: SVE Bulletin No. Q-252 Date Issued: 08/08/16 Page 4 of 5 Relay and Fuse diagram UPFITTER RELAY BOX F2 F3 F1 F4C F10 UPFITTER PTO RELAY F9 F8 F7 F6 F5 1 3 1 3 UPFITTER RUN/START RELAY 5 2 5 2 UPFITTER RELAY 2 F4A Fuse 2 3 5 UPFITTER RELAY 5 1 2 1 1 UPFITTER RELAY 4 3 5 1 Amps Circuits protected 40 Upfitter relay 5 F2 40 Upfitter relay 6 F3 25 Upfitter run/start relay F4A or F4C 5 Upfitter switch F5 25 Upfitter PTO relay F6 20 Customer access F7 25 Upfitter relay 4 F8 25 Upfitter relay 3 F9 25 Upfitter relay 2 F10 25 Upfitter relay 1 2 3 5 2 F1 5 3 2 5 1 3 5 3 UPFITTER RELAY 6 1 2 UPFITTER RELAY 3 UPFITTER RELAY 1 Originator: BBAS Document: SVE Bulletin No. Q-252 Date Issued: 08/08/16 Page 5 of 5
© Copyright 2025 Paperzz