NE NE 2 mg/m3 2 mglm3 Boiling Point: 101`C,214"F Skjn?Yes

Axcent Self Cure Liquid Monomer
Section I
Garreco, lncManufacturer: P. O. Box 1258
Heber Springs, AR
Material Safety Data Sheet
Emergency Telephone Number: CHEMTRAC 800-424-9300
Telephone Numberfor lnformation: 501-362-6261
72543
Date Prepared: 1ot15to7
Section ll - Hazardous lngredients/ldentity lnformation
Hazardous
Components
OSHA
80-62-6)
Substituted Toluidine (CAS# 99-97-8)
Benzophenone (CAS# 131-57-7)
Hydroquinone (CAS# 123-31-9)
PEL
ppm
NE
NE
2 mg/m3
Methyl Methacrylate (CAS#
100
ACGIH
TLV
Other Limits Recommended
100 ppm
NE
NE
2
mglm3
Section lll - Physical/Chemical Characteristics
Boiling Point:
101'C,214"F
Specific Gravity (Hr0=1): 0.94
Vapor Pressure (mm Hg.):29 mm at 20"C, 68'F Melting Point: N/A
VaporDensity(AlR=1):3.5@60"F,16"C EvaporationRate(ButylAcetate=1):3.0
Solubility in Water: 1.69/1009 @ 20'C,
68'F
Appearance and Odor: Clear, pale liquid, with an acrid fruity odor
Section lV - Fire and Explosion Hazard Data
Flash
Point: 10"C,
51'F
Flammable
Limits
LEL. 2.12
UEL: 12.5
Extinguishing Media: Chemical foam, carbon dioxide, dry chemical.
Unusual Fire and Explosion Hazards: Vapors may travel to source of ignition and flash back. Heat can cause polymerization
with rapid release of energy which may rupture container explosively.
Special Fire Fighting Procedures. Wear self contained breathing apparatus & full protective gear. EXPLOSION HAZARD-Fighl
fire from protected location. Use water spray to cool containers.
Section V - Reactivity Data
Stability:
Unstable
Conditions to Avoid: Heat and ignition sources, aging and contamination.
lncompatibility: Oxidizing agents, reducing agents, and UV light. Material has strong solvent properties.
Hazardous Decomposition or By-products: Oxides of carbon when burned.
Hazardous Polymerization: May Occur
ConditionstoAvoid: TemperaturesaboveT0'F,2l"C,oxidizingorreducingagents,peroxides,acids,alkaliesandamines.
Section Vl - Health Hazard Data
Route(s) of
Entry:
lnhalation?
Yes
Skjn?Yes
lngestion? Yes
Health Hazards: Acute or Chronic, N/A
Carcinogenicity: NTP?
Hydroquinone
IARC Monographs?
No
OSHA Regulated? No
Signs and Symptoms of Exposure. Headaches, nausea, staggering gait, confusion, drowsiness and unconsciousness.
Medical Conditions Generally Aggravated by Exposure: NAIF
EmergencyandFirstAidProcedures. lnhalation.Removetofreshair. lfbreathinghasstoppedgiveoxygen.Eye: Flushwithwaterincludingunder
evelids. Skin: Wash thorouqhlv with soap and water. lnqestron: Do not induce vomitinq. Rinse mouth out with water.
Section Vll - Precautions for Safe Handling and Use
Steps to Be Taken in Case Materaal is Released or Spilled. Evacuate area. Eliminate sources of ignition. Use self-contained breathing apparatus
and protective clothing. Dike and absorb with inert material. Transfer to proper containers for disposal, use non-sparking tools. Contaminated
monomer may be unstable, add inhibitor to prevent polymerization. Keep spills and cleaning runoffs out of sewers and open bodies of water.
WasteDisposal Method. WhendrscardeditislistedasahazardouswastebyEPAunderRCRAU-l62withthereportablequantity(RQ)
of 1000 lbs.
lncinerate liquid and diking material after addition of excess inhibitor, in accordance with Federal, State, and Local regulations.
Precautions to Be Taken in Handling and Storing: Observe precautions found on the label. Store in cool. dry place away from heat, sparks, flame,
and direct sunlight. Close container after each use. Ground all metal containers when transferring. Check inhibitor levels every 3 months.
Other Precautions. Wash face and hands thoroughly with soap and water after handling and before eating, drinking, or smoking.
Section Vlll - Control Measures
Respiratory Protection: Use self-contained breathing apparatus when needed.
Ventilation
Recommended
NAIF
gloves recommended
Special: NAIF
Local Exhaust:
Other: NAIF
Mechanical (General):
Protective Gloves: lmpervious
Other Protective Clothing or Equipment: Prolectjve creams for clean up
Eye Protection. Safety glasses or chemical splash goggles
only.
Work/Hygienic Practices: N/A
Axcen- SC L qu d.x1s
I'IATfiRTAL SEFETT
5Ef;ASil
NEfE
SHEE*f
I
*ARUF*CTUEERI
c*-Gfal-{tE Dentnl Hfg cs. inc,
33{U Su*rjss Hltd
Eancho Cor4oua, CA 95?42
?gT^EFHONE
Fr6)
638-S382
',F#f;$jg#ff***" ffir
FRODOCT:
Uethacryt*te)
r€Rl,tUtAr *(CHeC(clt3lc0ScH3]-X + Dinlkyl Fhtlalate
$SI*rTSS
Dialkd.
BSIHCIPAL HA'AE}O{S :HG*ED:EHTS
T
<15
$TlCgIotE ItS pt{YSrC*r,
rhthelate
E:rAPOREtTOit
lII
B&fEl ilA
s*tu8lL3ru IH HA?HR:
VAFSS
{renluhle
A*FROXIF{A*$ BOILTIiG fiANQE: Hot
APPEABailCE AHD
5
F$Mr (HetHOnl:
APPRSX" !'LAHi{AEIE
IV!
UEN*ryl *ot
Appliccbl"e
pn&*U*e VOtAllLE; {5*
At}Filg*ah}e DSI{SITXI Hot
FIRB
El^ffih ignition
fJEIfS:
mpm
Oh?A
*DOR; I**e ponder. Faint ceor in
$ECIIOH
F5.ASH
TLV
*
Rppli*able
bullG
ErmroffiSil D&fA
aF*mr, 3g4C frccl
Not applicable
E:i?IHGU:SttIilc FIEtrIA: farbon dioride, $at€sr, &y.
cheniel
SPTCIAL FJRE FTGHftl,lS FfiOCFDllflESr Svaid exfinEuishing metftod,* uhich nay
gererat$ dust clou*p. i{ater $tie*m cae di*peree dHsh in air, producfng n
fire hazard and pcsfiible *xplosian hazard if expcsed to ig*ilion scurce,
e EXPL*SI+N I{efiAHn& P*lyrcex dupt is cosrbrisfib}e. fh€
the p*lymer p*rticle *uspended in air are apgroximately
those cf coal drrst- fjr€dight*rc should r+ear s€ff,-mntairred br-eathirE
trHtlS*BL fsRE
explmive
H*its
cvf
aFparcttE
$ECTIOH
VI
I{fifr,LTH HA9.il,RO EAfA
IN€ESEiOi*l flinse *rou*r out with Hats, InEestlon of srnall guantities of
thrig material under normel c:rcunstances $oLr]d not cause harmfui. effect.
nee 5/89