B C 230 * 15 M BARS @ 150 mm O.C. * STORM A SIZE * A B 4-15 M BARS @ 50 mm O.C. C PLAN A DIMENSION B SANITARY SIZE DIME- 250 300 375 450 NSION 750 780 825 870 915 1675 825 825 870 915 960 1750 900 870 915 960 1000 1830 975 915 960 1000 1045 1905 1050 960 1000 1045 1090 1980 1200 1045 1090 1135 1180 2135 1350 1135 1180 1225 1270 2285 1500 1225 1270 1315 1360 2440 1650 1315 1360 1400 1445 2590 1800 1400 1445 1490 1535 2745 1950 1490 1535 1580 1625 2895 2100 1580 1625 1670 1715 3050 SLAB REINFORCING SCHEDULE CHIMNEY WALLS TO BE 230 mm THICK THROUGHOUT CHAMBER WHERE TOTAL DEPTH IS LESS THAN 4.6 m & 300 mm WHERE TOTAL DEPTH IS GREATER 230 230 660 15 mm PARGING ADJUSTMENT UNITS. IF BRICKS ARE USED, THICKNESS TO 230 AGREE WITH THICKNESS OF 660 230 230 660 230 CHIMNEY WALLS. 460 660 230 230 23 0 KEYWAY & EXTENDED STEEL OR 15 M DOWELS @ 300 mm IF CONCRETE CHIMNEY IS USED. 900 SANITARY ‘ H’ STORM 300 NOTE 915 MIN. SECTION * NOTES: B 230 mm UNDER 4.6 m 300 mm OVER4.6 m 150 B * SECTION A A 150 B * 230 STORM 230 230 150 1200 1200 SEE NOTE 7 SANITARY ‘ H’ 300 230 SEE NOTE SEE 15 M DOWEL @ 460 mm O.C. 75 mm COVER. LAP 24 DIA. TO EXTEND 175 mm INTO BASE SLAB. 150 900 230 760 760 SEE NOTE 7 15 M BARS @ 460 m m O. C.VERT. 15 M BARS @ 230 m m O. C.HORI Z. I N ALL W ALLS THAN 4.6 m MAXIMUM 300 mm OF VERTICAL * SECTION C * PIPE BARREL THICKNESS + 230 mm UNDER 4.6 m + 300 mm OVER 4.6 m 1. CONCRETE TO BE 32 MPa AT 28 DAYS CAST IN PLACE. 7. FOR USE ON STRAIGHT RUNS ONLY 2. REINFORCING STEEL TO BE 350 MPa DEFORMED BARS 1.2 m FOR DEPTHS 2.0 m to 2.3 m MINIMUM COVER TO BE 50 mm LAP 24 BAR DIA. 3. FIRST STEP TO BE 75 to 300 mm BELOW FRAME. LAST STEP TO BE 300 mm ABOVE BENCHING OR H= 1.5 m FOR DEPTHS 2.3 m to 2.8 m STACK 760 mm X 760 mm 1.8 m FOR DEPTHS 2.8 m to 3.2 m 2.1 m FOR DEPTHS 3.2 m and over STACK 760 mm X 900 mm 600mm ABOVE INVERT IF NO BENCHING. 4. ALL BOXES FOR FUTURE SEWER TO HAVE 50 mm x 100 mm KEYWAY ON ALL SIDES. 8. PARGING SHALL BE 1:3 MORTAR MIX. 9. WATERPROOFING OVER PARGING TO BE TWO HEAVY COATS 5. TOP OF BENCHING TO BE SLOPED TO A MAXIMUM OF 8:1 6. IF DEPTH IS SUFFICIENT TO WARRANT A SAFETY PLATFORM CHIMNEY SHALL BE 1200 mm x 1200 mm. OF BITUMEN. 10. WHERE PIPES JOIN AT MAINTENANCE HOLE, JOINTS ARE TO BE WATERTIGHT WITH THE APPROVED SEAL. All dimensions are in millimetres unless otherwise shown. ENGINEERING AND CONSTRUCTION SERVICES STANDARD DRAWING REV 1 APR 2013 TYPICAL DUAL MAINTENANCE HOLE T-701.013-1 WITH INVERTS LEVEL MINIMUM STORM SIZE 750 mm DIAMETER NTS SHEET 1
© Copyright 2026 Paperzz