S T A N D A R D 2.25 DMS1.1 / DM1.1 / DML1.1 Modulating Actuators AC/DC 24 V Application The JOVENTA STANDARD electric damper actuator series is designed to operate air dampers in ventilation and air conditioning systems. The compact design and universal adapter fitted with limitation of rotation angle make this JOVENTA actuator highly versatile. Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ DC 0(2)...10 V or 0(4)...20 mA control signal Working area adjustable Load-independent running time Up to 5 actuators in parallel operation possible Plug-in terminal block connection Simple direct-mount with univer-sal adapter on 10...20 mm Ø round-axis or 10...16 mm square shaft 48 mm minimum damper shaft lenght Selectable direction of rotation Limitation of rotation angle Manual release button 2 adjustable auxiliary switches Automatic shut-off at end position (overload switch) Actuators available with 1 m cable Customized versions available Devices meet CE requirements Accessories PB_DMS1.1 / DM1.1 / DML1.1_04 2008 ■ ZK Damper linkage selection ■ ZKG Ball joints Ordering Codes Codes Descriptions DMx1.1 AC/DC 24 V AC/DC 24 V, with 2 auxiliary switches DMx1.1S Technical Specifications Actuator Torque Damper area* Running Time OPEN Running Time CLOSE Supply Voltage Frequency Power Consumption - Running - At end position Dimensioning Working area Y Control Signal Y1 Imput resistance Y1 Control signal Y2 Imput resistance Y2 Position signal U Load resistance Angle of rotation/ Working range Angle of rotation/ Limitation Auxiliary Switches - S1 setting range - S2 setting range Cable - Motor - Switches Life time Noise level Protection Class Degree of Protection Mode of Action Ambient conditions - Operating temperature - Storage temperature - Humidity Weight Service Standards - Mechanics - Electronics - EMC Emissions - EMC Immunity DMS1.1(S) DM1.1(S) DML1.1(S) 8 Nm 1.5 m2 30 s 30 s 16 Nm 3.0 m2 80 s 80 s AC/DC 24 V 50-60 Hz 24 Nm 4.5 m2 125 s 125 s 2.5 W 0.3 W 6.0 VA / 3.6 A @ 2 ms not adjustable DC 0... 10 V Ri 250 Ω 0...20 mA Ri 388 Ω DC 0...10 V > 50 k Ω 90° (93°mech.) 5°...85° in 5° < steps 3(1.5) A, AC 230 V 5°...85° < adjustable 1.0 m halogen-free 5-Wire 1-2-4-5-6 5-Wire 21-22-23-24-25 60.000 rotations 45 dB (A) II IP 54 Type 1 –20...+50 °C / IEC 721-3-3 –30...+60°C / IEC 721-3-2 5...95% r.F. no condensed 1.1 Kg Maintenance-free EN 60 529 / EN 60 730-2-14 EN 60 730-2-14 EN 50 081-1:92 / IEC 61000-6-3:96 EN 50 082-2:95 / IEC 61000-6-2:99 *Caution: Please note damper manufacturer’s information concerning the open/close torque. - Page 1 This document is subject to change without notice. S T A N D A R D 2.25 DMS1.1 / DM1.1 / DML1.1 Modulating Actuators AC/DC 24 V Dimensions in mm Wiring Diagram Parallel Connections Setting the control Signal Control signal Y1 Input resistance DC 0...10 V Ri 250 kΩ Microswitch d Self-adapting Control signal Y2 Input resistance 0...20 mA Ri 388 Ω Dectivated Position signal U Load resistance DC 0...10 V > 50 kΩ Activated By switching microswitch d to ON position, the control signal Y1 or Y2 will be adapted to the chosen angle of rotation. Position transmitter Microswitch c By switching microswitch c the direction of rotation can be changed. DM DML DMS Setting Span and OFFSET The potentiometers O and S help to match control signals Y1 and Y2 to any make of controller. PB_DMS1.1 / DM1.1 / DML1.1_04 2008 The DMxx can also be controlled using the JOVENTA Positioner (PA/PF) with control signal of DC 0...10 V. For further information concerning the PA and PF positioner please refer to sheet 6.20. Caution: A maximum of 5 actuators can be controlled in parallel operation. Example 1 Example 2 Control signal Y1 working between DC 2...10 V Control signal Y2 working between 6...18 mA Setting: Setting: Starting point O=2 working range S=8 Starting point O=3 Working range S=6 Start point O Scale O 0 1 2 3 4 5 6 7 for Y1 (VDC) 0 1 2 3 4 5 6 7 8 8 for Y2 (mA) 0 2 4 6 8 10 12 14 16 Scale S 2 3 4 5 6 7 8 9 10 for Y1 (VDC) 2 3 4 5 6 7 8 9 10 for Y2 (mA) 4 6 8 10 12 14 16 18 20 Working range S - Page 2 This document is subject to change without notice. S T A N D A R D 2.25 DMS1.1 / DM1.1 / DML1.1 Modulating Actuators AC/DC 24 V Auxiliary Switches (S) Settings the auxiliary switches Factory setting Switch a at 10° Switch b at 80° The switching position can be manually changed to any required position by turning the ratchet. Override Control Limitation of Rotation Angle Adapter release The actuator DMxx can be forced to override control when wired in accordance with the diagram. The limitation or rotation angle can be set in 5° steps by moving the adapter. PB_DMS1.1 / DM1.1 / DML1.1_04 2008 Switch position: 1 = Actuator runs at 10 V 2 = Actuator runs at 0(2) V 3 = Automatic control - Page 3 This document is subject to change without notice. The adapter can be remove simply by pressing the adapter clip on the underside of the actuator
© Copyright 2025 Paperzz