Cat. No.D02-01 Thermometers with Electric Contact OUTLINE This thermometer with an electric contact is an indicating thermometer in which an electric contact is installed. The contact can be set at any positions. A pressure type thermometer, in which liquid is charged and its expansion and contraction due to temperature change is applied, is used as an temperature element. This thermometer is classified into the non-mercury organic liquid filled type and mercury filled type. Additionally, this catalog is formed by classifying this thermometer into the type with a microswitch and the type with a contact point according to the type of applied contact, and into the drip-proof type and the pressure resistant explosion-protected type according to the construction of a case. * When selecting a thermometer, select a thermometer which is normally applied to a temperature range of 30% to 60% of full span. Check to confirm that the material of the wetted parts is appropriate to measuring gas or liquid. SPECIFICATION 1 Manufacturing temperature range: Liquid filled type • -70g ~ 600g Mercury filled type • -50g ~ 650g Electric contact type: With micro switch With contact switch Construction: Indoor use (With contact switch) Drip-proof type (With micro switch) Explosion-protected type (d2G4) Water-proof (Application for transformer) Dial Size: 100 DIA., 150 DIA. * 75 DIA. of thermometers with contact switch is available. Contact NKS for details. Mounting: Remote surface mounting Remote panel mounting (Mounting hole • Mounting clamp) Bulb • Connection material: 304st.st. Bulb material: Capillay Armored tube 304st.st. or 316st.st. 430st.st. or 430st.st. +PVC Connection: R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF * For other connections, please contact us. Accuracy: Indicator accuracy Reproductibity Within ±2%F.S. Within 2%F.S. SELECTION GUIDE OF THERMOMETERS WITH ELECTRIC CONTACT1 1. Features of switch Micro switch F Traveling contact Plunger Micro switch is able to take electricity rating greatly, and is available for various control other than dispatch of warning with safety from vibration. Contact point (Open and low contacting pressure) switch Hair spring Setting tip Element move a type of contact point b type of contact point Mounting Characteristic Moving tip Mercury filled type Type Rating Liquid filled type Mercury filled type Micro switch Liquid filled type Contact switch Resistance load Inductire load* 125V AC 5A 125V AC 4A 250V AC 5A 250V AC 4A 30V DC 5A 30V DC 4A 125V DC 0.4A 125V DC 0.4A -•-•-•-•-•* AC: Power factor more than DC: Time-contact 7ms or less. Withstand voltage The contact point is mainly applied to warning including a buzzer and a slashing lamp. However, it can be applied to switching large capacity electricity on and off through a relay. A contacting tip is made of high melting point alloy of platinum and osmium. A contact point should be applied under the normal open mode. Resistance load 100V AC 0.5A 200V AC 0.25A 100V DC 0.05A 200V DC 0.025A 1500V AC 1 minute The insulation resistance (with microcontact) should be 100MΩ or larger by a 500V DC megger. * The minimum load of the microcontact is 800mW and that of the contact point 1W. In the case of the microcontact, minute load application can be specified. 1000 V AC 1 minute 2. Explosion-protected temperature switch The electric appliance, which is used at hazardous areas where inflammable gas or liquid causing ignition explosion exists, is imposed use of the the explosion protected products which passed national official approval. Thermometers with electric contact used at each place of the factory , indoor storage, outdoor tank storage, indoor tank storage, general handling place, passage handling place of dangerous materials is available for pressure-proof and explosion- proof type. 3. Compensation system by installation place When the ambient temperature around temperature gauge changes, the filled liquid in the indicator and capillary tube also changes to expand or shrink and this cause the indication error. To compensate this error, following compensations are provided. (1) Bimetal compensation • When the ambient temperature around indicator and lead parts changes at a same time. (2) Lead compensation • When the ambient temperature around indicator and lead parts changes independently. 1) When the temperature change around indicator is small and big for lead parts or it's opposite case. 2) When the lead parts is under various ambient temperature condition. 3) When a part of lead parts is heated. 1) 2) 3) Boiler 4. Temperature range (Scale range) Normal using range. • Scale range should be selected to use normally between 30 to 60% of full span. • When the temperature exceeds the temperature range, it may cause to break the temperature gauge. For example, if there will be a case that the gauges pass the right on the equator or cold district during transportation, or store them at cold district, it needs careful attention. 2 SELECTION GUIDE OF THERMOMETERS WITH ELECTRIC CONTACT2 4. Bulb type Union type • Standard spec. By tightening the fixing screw, it fixied to the connecting thread so that position of bulb does not change. Maximum allowable working pressure of union type is Less than 200g h 2MPa Over 200g h 1MPa Bulb Fixing screw (If the pressure is higher than above, thermowell should be provided.) Connecting thread Slide type • At the time when it needs to adjust the bulb position by the changing the position of fluid to be measured in a tank or other vessel. • At the time when it needs to insert the bulb up to the bottom of thermowell. Bulb Connecting thread Fixing screw By tightening the gasket with fixing screw, bulb can be fixed at any position. Maximum allowable working pressure of slide type is 0.3MPa (If the pressure is higher than above, thermowell should be provided.) Gasket Plain type • In case the bulb to be casted into the fluid. 5. Bulb minimum insertion length Minimum insertion length Minimum insertion length According to type, temperature range and bulb diameter, minimum insertion length is decided. When placing order or decide the specifications, select a suitable length which is longer than the minimum insertion length to keep the performance. A good example A bad example 6. Thermowell In the case of following conditions, thermowell should be provided to protect bulb. (1) In case of corrosion fluid, thermowell with suitable material is necessary. (2) In case of high pressure, necessary to use thermowell suitable for operating pressure. (3) In case of fluid with flow, necessary to use thermowell suitable for flow and viscosity. (4) In case of fluid leaking out when taking off the thermometer,necessary to use thermowell. (5) In case of filled liquid in thermometer is leak out from bulb and it is harmful, necessary to use thermowell. (1) (2) Corrosion (3) (4) High pressure Flow 3 Taking off thermometer (5) Leakage of filled liquid THERMOMETERS WITH ELECTRIC CONTACT1 1. With micro switch thermometer Mounting Max. lead Dial size length (mm) Sensing method Manufacturing range Compensation Liquid filled type -70g ~ 150g Lead compensation - Liquid filled type -70g ~ 300g Lead compensation 15m 100 Model TF14 Drip-proof type (Non-explosion protected) I stem type Mercury filled type -50g ~ 650g Bimetal compensation 10m TE54 Liquid filled type -70g ~ 300g Lead compensation 20m TF56 Mercury filled type -50g ~ 650g Bimetal compensation 10m Liquid filled type -70g ~ 300g Lead compensation 20m Hole mounting Clamp mounting Mercury filled type -50g ~ 650g Bimetal compensation 10m Hole mounting Clamp mounting Liquid filled type -70g ~ 300g Lead compensation 20m Mercury filled type -50g ~ 650g Bimetal compensation 10m Liquid filled type -70g ~ 300g Lead compensation Mercury filled type -50g ~ 650g Mercury filled type 100 DIA. surface mounting 150 150DIA. surface mounting Clamp mounting 20m - TD25 Bimetal compensation 10m - TD21 -30g ~ 650g Bimetal compensation 5m 100 TX54 Mercury filled type -30g ~ 650g Bimetal compensation 5m 150 TX56 Liquid filled type -70g ~ 300g Lead compensation 20m 150 TX81 100DIA. panel mounting Explosion-protected type TE56 TF64 TF74 TE64 TE74 TF66 TF76 TE66 TE76 150DIA. panel mounting * For transformer (Waterproof and moisture protected type) TF54 100 Hole mounting Clamp mounting Hole mounting Surface mounting Surface mounting * Specifications in accordance with JEM standard. 4 THERMOMETERS WITH ELECTRIC CONTACT2 2. With contact switch thermometer Drip-proof type (Non-explosion protected) Mounting Surface mounting Panel mounting (Hole mounting ) * For transformer (Waterproof and moisture protected type) Explosion-protected type Panel mounting (clamp mounting ) Sensing method Manufacturing range Compensation Max. lead length Dial size Model (mm) Lead compensation h20m 100 Bimetal compensation h5m 150 Lead compensation h50m 100 Bimetal compensation h20m 150 Lead compensation h20m 100 Bimetal compensation h5m 150 Lead compensation h50m 100 Bimetal compensation h20m 150 Lead compensation h20m 100 Bimetal compensation h5m 150 Lead compensation h50m 100 Bimetal compensation h20m 150 TK54 TK56 TJ54 TJ56 TK64 TK66 TJ64 TJ66 TK74 TK76 TJ74 TJ76 -70g ~ 500g Bimetal compensation 5m - TD10 Mercury filled type -50g ~ 650g Bimetal compensation 20m - TD11 Liquid filled type -70g ~ 500g Bimetal compensation 5m 100 TW84 Liquid filled type -70g ~ 500g Bimetal compensation 5m 100 TW54 Liquid filled type -70g ~ 500g Mercury filled type -50g ~ 650g Liquid filled type -70g ~ 500g Mercury filled type -50g ~ 650g Liquid filled type -70g ~ 500g Mercury filled type -50g ~ 650g Liquid filled type Indoor use Water-proof type * Specifications in accordance with JEM standard. 5 CONNECTION • BULB SPECIFICATION 1. Without thermowell Connection d DIA. Connection Fixing screw W22 Thread 14 Bulb out dia. d DIA. Flange type d DIA. Union type Screw type • Not available to direct type and slide type. 10 DIA. 24 (10) L 34 Max. operating pressure: 2MPa (20kgf/cm2) for less than 200g 1MPa (10kgf/cm2) for 200g or over 12 DIA. Fixing screw d DIA. T d DIA. Gasket Connection Slide type 8 DIA. Note 13 DIA. L (10) 40 16 DIA. • T=1/2 is not available. • Slide type is not available. Thermowell out dia. d1 DIA Bulb out dia. d DIA Max. operating pressure 0.3MPa (3kgf/cm2) 2. With thermowell Connection Flange type d1 DIA. Union type L (10) 45 d1 DIA. 15 DIA. 10 DIA. • T=1/2 is not available. L (10) 40 19 DIA. 13 DIA. Connection R1/2 (PT) or 1/2 NPT d1 DIA. W22 thread 14 (10) L Fixing screw 23 DIA. 13 DIA. (25) 45 • T=1/2 is not available. • Welding type well is not available. Coneection R1/2 (PT) or 1/2 NPT L (10) (25) 45 Flange rating R1/2 (PT) , 1/2NPT G1/2B (PF) R3/4 (PT) , G3/4B (PF) JIS10K20ARF JIS10K25ARF ANSl1B150RF ANSl1B300RF (Fixing screw only=W22 thread14) Taper 19 23 Fixing screw Connecting screw Standard connection Note 12 DIA. 8 DIA. d1 DIA. Standard type Double socket type Fixing screw Slide type Fixing screw W22 thread 14 Union type Slide type Screw type 13 DIA. • T=1/2 is not available. • Welding type well is not available. Note Other connections except shown left are available. Contact NKS for details. 3. Plain type Note fd Plain type Bulb L d DIA.=8 DIA., 10 DIA., 12 DIA., 13DIA., 16 DIA. 6 Remote type only. Not available to direct type. GRADUATIONS Refer to the manufacturing specifications of respective models regarding the graduations of respective models. range g Scale division and number entry position 0 ~ 50 0 0 0 0 ~ 100 0 ~ 500 0 ~ 60 10 20 100 0 0 0 0 ~ 120 0 ~ 600 0 ~ 80 10 20 100 20 40 200 0 0 0 ~ 400 0 ~ 150 0 ~ 250 0 ~ 650 60 50 0 100 -10 -20 0 0 100 100 60 120 600 60 300 80 400 120 150 150 150 150 200 50 100 500 50 100 500 100 50 0 40 80 400 90 50 0 0 ~ 300 40 80 400 40 200 30 0 30 60 300 30 60 300 20 100 0 0 ~ 200 20 40 200 200 200 200 300 250 250 400 300 500 TD21 • TD25 600 650 Contact indication figure -10 ~ 50 -20 ~ 100 -10 ~ 100 -10 -30 ~ 50 0 -30 -30 ~ 120 -50 -70 ~ 50 -70 -70 ~ 100 -70 20 40 20 -20 -30 -50 ~ 50 10 20 -10 -40 -50 TE 5 • 6 • 7 (100 DIA.) (With micro switch) 10 -20 0 50 100 80 20 30 60 0 -20 40 80 60 30 -40 -60 40 0 0 30 60 100 40 50 90 20 0 120 40 20 40 50 50 50 Mark in case of two contacts 100 TE 5 • 6 • 7 (150 DIA.) TF 5 • 6 • 7 (150 DIA.) (With micro switch) Contact indication figure Contact indication figure TJ 5 • 6 • 7 (100 DIA., 150 DIA.) TK 5 • 6 • 7 (100 DIA., 150 DIA.) (With contact switch) TD10 • TD11 Contact indication figure Contact indication figure Contact point type Mark Upper limit type H OFF ON Lower limit type L ON OFF Upper & Lower limit type HL ON OFF OFF ON Ground: white Entry: Black color, red for graduation line and figure of minus parts. 7 TYPE OF CONTACT AND WIRING SYSTEM With micro switch 1. Upper limit type with one contact • H (Connecting 1) - 2)) Wiring When the temperature rises to a set value, contact points work to turn a circuit ON. Black pointer Operation set min. 3 max. OFF Load Power source Increase in temperature ON OFF 2 1 ON Black pointer Decrease Wiring 1) and 2) reverses ON and OFF at the set point. Note: If this type is applied as the lower limit type, setting should be corrected by the dead band. Dead band 2. Lower limit type with one contac • L (Connecting 2) - 3)) Wiring When the temperature decreases to a set value, contact points work to turn a circuit ON. Black pointer Operation Dead band ON 1 ON OFF Decrease Black pointer Power source Wiring 1) and 2) reverses ON and OFF at the set point. Note: If this type is applied as the upper limit type, setting should be corrected by the dead band. max. set Load Increase in temperature OFF min. 2 3 3. Upper & lower limit type with two contact • HL (1) - 2) Connecting, 5) - 6) Connecting) Wiring Black pointer This is the combination of the upper limit type and the lower limit type and each works independently. Refer to the previous 1 and 2 for the functioning figure. 3 2 1 Load 4 5 6 Load Red pointer 3 2 1 Power source Power source Wiring 4. Upper limit type with two contact • 2H (Connecting 1) - 2), Connecting 4) - 5)) This is the combination of two upper limit types and each works independently. Refer to the previous 1 for the functioning figure. Black pointer Load 6 5 4 1 2 3 Load 4 5 6 Load Load Red pointer Power source Power source Wiring 5. Lower limit type with two contact • 2L (Connecting 2) - 3), Connecting 5) - 6)) Black pointer This is the combination of two lower limit type and each works independently. Refer to the previous 2 for the functioning figure. Power source Power source Red pointer 6. Center parts setting type with two contact • HLR Wiring This is the series combination of the upper limit type and lower limit type. When both contact points are ON, the circuit turns ON. Operation OFF min. OFF ON set set 2 1 Load max. Power source Black pointer Red pionter With contact switch Wiring 1. Upper limit type with one contact • H When the temperature rises to a set value, contact points work to turn a circuit ON. Load 1 Upper limit Operation Power source 2 OFF min. ON set Black pointer max. Wiring 2. Lower limit type with one contact • L When the temperature decreases to a set value, contact points work to turn a circuit ON. Load 1 Operation Lower limit ON min. OFF set max. 3. Upper & lower limit type with two contact • HL Wiring Upper limit This is the combination of the upper limit type and the lower limit type. Because of the common pole, each circuit doesn't work indepently. Operation OFF min. ON set ON Power source 2 Red pointer Lower limit Black pointer max. OFF Red pointer 2 3 Load 1 Power source Load 8 EXPLOSION-PROOF Explosion-protected construction Explosion-protected construction is a totally enclosed construction such that even if the explosive gas explodes inside the container, the container withstands the force of the explosion and there is no danger of ignition of external explosive gases. Application range: d2G4 1) Explosion-protected construction: d 2) Explosion class :2 3) Ignitability : G4 4) Hazardous areas : Zone 1 or zone 2 5) Objective industries: Petrochemical, chemical fiber, syntthetic resin, ethylene, methanol,dielectric products manufacturing, liquefied gas, electric hurnace, pharmaceuticals, paints, ammonium sulfate, soda, other measurement medium or industries in which there is the danger of ighition and explosion. Classification of hazardous areas: Hazardous area Contents Zone 0 A place where hazardous atmosphere is continuously pressent or present for a long period under ordinary circumstances. Zone 1 A place where hazardous atmosphere is likely to occur under ordinary circumstances. Zone 2 A place where hazardous atmosphere is likely to occur under abnormal circumstances. Explosion test equipment Classification of explosion: 1 Minumum gap with a 25mm lenght of patch which permits the flame propagation. Over 0.6mm 2 0.4mm to 0.6mm 3 Up to 0.4mm Explosion class Classification of ignition groups: Ignition class Ignition point Limits of temperature rise (deg) G1 Over 450g 320 G2 300g to 450g 200 G3 200g to 300g 200 G4 135g to 200g 200 G5 100g to 135g 200 G6 85g to 100g 200 Example of classification of typical explosive gases: Ignition class Explosion class The standard ambient temprature range limit of the electrical instrument in the normal using shall be 40g G1 G2 G3 G4 Acetone Ethanol Gasoline Acetadehyde Hexane Etyhl ether Ammonia Amylacetate-iso Carbon monoxide 1-Butanol Ethane Butane G5 Acetic acid Butric anhydride 1 Ethyl acetate Toulene Propane Benzene Methanol Methane 2 3 Carbon gas Water gas Hydrogen Ethylene Ethyelenoxide Acetylene Carbon dioxide 9 G6 EXPLOSION-PROOF 2 Method of leading external conductors and cable to a terminal box 1) Flame-proof packing type Cable Cable out side DIA. Protection tube Inner dia. Connection Ring packing Out dia. 9. 4 10. 5 23 12 9. 9 10. 1 PF1/2 10. 5 PF3/4 11. 0 11. 5 11. 9 14 12. 0 12. 5 12. 6 29. 5 13. 1 15. 5 13. 5 PF3/4 Terminal box PF1 Washer 13. 6 14. 5 16. 5 15. 6 d DIA. D DIA. Ring packing M6 set screw Cable gland Cable clamp Cable protection tube connection Cable outside diameter 2) Conduit type Conduit tube connection PF 3/3 10 THERMOMETERS WITH MICRO SWITCH / DRIP-PROOF • DIRECT TYPE TF14Liquid filled dial thermometer #Dimension (102) (104) 112 DIA. 136 Gasket bore. 9 DIA. Setting positioning axis I stem type #Specification Manufacturing range -70 ~ 150g Case Construction: Drip-proof • equivalent to IP33, Material: AC7A , Finishing: Black Use switch Accuracy Wetted parts material Bulb: 304st.st., Connection • Flange: 304st.st. JIS C 4505 Industrial switch Indication Within ±2% F.S.. (No load to contactor) Electric rating Resistance load Inductive load* 125V AC5A 125V AC4A Setting Setting Internal abjustment 250V AC5A 250V AC4A 30V DC5A 30V DC4A Compensation Lead compensation 125V DC0.4A 125V DC0.4A -• -• -• -• -• -• -•Dead band Within 6% F.S. * AC: Power factor more than 0.4 Ambient temperature error Within ±2% F.S./15deg DC: Time-contact 7ms or less Connection R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. Number of contacts One contact • Two contact Flange Within 2% F.S. Within ±3% F.S. JIS10K20ARF, JIS10K25ARF, 0ANS11B150RF, ANS11B300RF Without thermowell Connection Reproductibity Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/ 1/ NPT (Connection) 2, 2 Slide type is not available with 8 Dia. and 16 Dia. bulb. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g -70 ~ 50 2 -70 ~ 100 5 -50 ~ 50 2 -30 ~ 50 2 -20 ~ 100 2 -10 ~ 100 2 -10 ~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length standard Bulb Dia.$Length d (d1) 10 (15) $ $ $ $ $ $ $ $ $ $ $ $ $ $ L (L) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) 150 (200) 150 (150) 150 (200) 200 (200) 150 (200) 150 (200) 300 (300) 300 (300) 300 (300) 200 (300) 200 (200) 150 (200) 150 (150) 160 (185) 125 (150) 180 (205) 215 (240) 160 (185) 170 (195) 265 (290) 355 (380) 315 (340) 245 (270) 205 (230) 180 (205) 155 (180) 130 (155) 105 (130) 145 (170) 170 (195) 130 (155) 135 (160) 210 (235) 270 (295) 245 (270) 195 (220) 165 (190) 145 (170) 125 (150) d=12 DIA. 100 85 110 130 100 105 155 195 180 145 125 110 100 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 11 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 90 (115) 75 (100) 100 (125) 115 (140) 90 (115) 95 (120) 135 (160) 170 (195) 155 (180) 125 (150) 110 (135) 100 (125) 90 (115) 75 (100) 65 (90) 80 (105) 95 (120) 75 (100) 80 (105) 105 (130) 135 (160) 120 (145) 100 (125) 90 (115) 80 (105) 75 (100) Max. 500 THERMOMETERS WITH MICRO SWITCH/DRIP-PROOF • REMOTE TYPE1 Liquid filled dial thermometer TF 54 • 100 DIA. • Surface mounting #Dimension (102) 3-5.5 DIA. Mounting hole 136 136 DIA. 112 DIA. P.C.D.122 Gasket bore. 9DIA. Setting positioning axis TF 56 • 150 DIA. • Surface mounting #Dimension (159) 3-5.5 DIA. Mounting hole 140 3 125 178 DIA. 159 DIA. P.C.D.165 76 Gland JIS20b Armored tube Setting positioningaxis TF 64 • 74 • 100 DIA. • Panel mounting #Dimension Mounting hole TF74 Mounting clamp 134 3-5.5 DIA. Mounting hole (46) 21 Gasket bore. 9 DIA. 4 P.C.D.124 Armored tube 110 DIA. TF64 112 DIA. Mounting 136 DIA. Model 2-Mounting clamp Setting positioningaxis TF 66 • 76 • 150 DIA. • Panel mounting #Dimension Model Mounting TF66 Mounting hole TF76 Mounting clamp 129.5 3-5.5 DIA. Mounting hole 159 DIA. 3 178 DIA. 15 P.C.D.165 30 Setting positioning axis 12 61 26 152 DIA. Gland JIS20b 3-Mounting clamp Armored tube THERMOMETERS WITH MICRO SWITCH/DRIP-PROOF • REMOTE TYPE 2 TF54 • 56 • 64 • 74 • 66 • 76 Liquid filled type #Specification Manufacturing range Case -70 ~ 300g Construction: Drip-proof • equivalent to IP43, Material: TF54 • 64 • 74: AC7A, TF56 • 66 • 76: ADC12, Finishing: Black Use switch Accuracy Wetted parts material Bulb: 304st.st., Connection • Flange: 304st.st. JIS C 4505 Industrial switch Electric rating Resistance load Inductive load 125V AC5A 125V AC4A Setting Internal abjustment Within ±3% F.S. 250V AC5A 250V AC4A 30V DC5A 30V DC4A 1 • 2 • 3 • 4 • 5 • 8 • 10 • 15 • 20 (m) Dread band Within 4% F.S. 125V DC0.4A 125V DC0.4A Standard 3m Max. 20m -• -• -• -• -• -• - • Ambient Within ±2%F.S./15deg * AC: Power factor more than 0.4 temperature error Lead compensation DC: Time-contact 7ms or less R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. Number of contacts One contact • Two contact Setting Lead length Compensation Connection Flange Within 2% F.S. JIS10K20ARF, JIS10K25ARF, ANS11B150RF, ANS11B300RF Without thermowell Connection Indication Within ±2% F.S. Reproductibity With thermowell Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. Double socket slide type: R1/2, 1/2NPT (Connection) * For other connections, please contact us. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g -70 ~ 50 2 -70 ~ 100 5 -50 ~ 50 2 -30 ~ 50 2 -20 ~ 100 2 -10~ 100 2 -10~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Standard Bulb Dia.$Length d (d1) 10 (15) $ L (L) d=8 DIA. (d1=12 DIA.) d=DIA.10 (d1=150 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 150 (200) 150 (150) 150 (200) 200 (200) 150 (200) 150 (200) 300 (300) 300 (300) 300 (300) 200 (300) 200 (200) 150 (200) 150 (150) 100 (150) 100 (150) 100 (150) 160 (185) 125 (150) 180 (205) 215 (240) 160 (185) 170 (195) 265 (290) 355 (380) 315 (340) 245 (270) 205 (230) 180 (205) 155 (180) 110 (135) 100 (125) 90 (115) 130 (155) 105 (130) 145 (170) 170 (195) 130 (155) 135 (160) 210 (235) 270 (295) 245 (270) 195 (220) 165 (190) 145 (170) 125 (150) 95 (120) 85 (110) 80 (105) d=12 DIA. 100 85 110 130 100 105 155 195 180 145 125 110 100 75 70 65 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 13 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 90 (115) 75 (100) 100 (125) 115 (140) 90 (115) 95 (120) 135 (160) 170 (195) 155 (180) 125 (150) 110 (135) 100 (125) 90 (115) 70 (95) 65 (90) 60 (85) 75 (100) 65 (90) 80 (105) 95 (120) 75 (100) 80 (105) 105 (130) 135 (160) 120 (145) 100 (125) 90 (115) 80 (105) 75 (100) 60 (85) 60 (85) 55 (80) Max. 500 THERMOMETERS WITH MICRO SWITCH/DRIP-PROOF • REMOTE TYPE3 Mercury filled dial thermometer TE 54 • 100 DIA. • Surface mounting #Dimension 3-5.5 DIA. Mounting hole (107) 76 4 P.C.D.122 62 136 DIA. 112 DIA. 30 Setting positioning axis Gland JIS20b TE 56 • 150 DIA. • Surface mounting #Dimension (159) 3-5.5 DIA. Mounting hole 140 3 125 178 DIA. 159 DIA. P.C.D.165 Gland JIS20b Armored tube Setting positioning axis TE 64 • 74 • 100 DIA. • Panel mounting #Dimension 76 Model Mounting TE64 Mounting hole TE74 Mounting clamp 9 3-5.5 DIA. Mounting hole (47) 21 4 P.C.D.124 110 DIA. 136 DIA. 112 DIA. Gland JIS20b 2-mounting clamp Setting positioning axis TE 66 • 76 • 150 DIA. • Panel mounting #Dimension TE66 Mounting hole Gland JIS20b Mounting clamp 3 P.C.D.165 Setting positioning axis 14 61 26 178 DIA. TE76 129.5 3-5.5DIA. Mounting hole 152 DIA. Mounting 159 DIA. Model 3-Mounting clamp Armored tube THERMOMETERS WITH MICRO SWITCH/DRIP-PROOF • REMOTE TYPE 4 TE 54 • 56 • 64 • 74 • 66 • 76 Mercury filled dial thermometer #Specification Manufacturing range -50 ~ 650g Construction: Drip-proof • equivalent to IP43, Material: TE54 • 64 • 74: AC7A, TE56 • 66 • 76: ADC12, Finishing: Black Case Use switch JIS C 4505 Industrial switch Accuracy Wetted parts material Bulb: 304st.st., Connection • Flange: 304st.st. Electric rating Resistance load Inductive load* 125V AC5A 125V AC4A Setting Internal abjustment Within ±4% F.S. 250V AC5A 250V AC4A 30V DC5A 30V DC4A Dead band Within 8% F.S. 1 • 2 • 3 • 4 • 5 • 8 • 10 (m) 125V DC0.4A 125V DC0.4A Standard 3m Max. 10m - •- •- •- •- •- •- •Ambient * AC: Power factor more than 0.4 Within ±2% F.S./15deg temprature error Bimetal compensation DC: Time-contact 7ms or less R1/2 (PT) , R3/4 (PT) , 1 /2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. Number of contacts 100 DIA.One contact, 150 DIA. One contact • Two contact Setting Lead length Compensation Connection Flange Indication Within ±2% F.S. Reproductibity Within 2% F.S. JIS10K20ARF, JIS10K25ARF, ANS11B150RF, ANS11B300RF Without thermowell Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2, 1/2NPT (Connection) Connection Slide type is not available with 16 Dia. bulb. * For other connections, please contact us. #Range • Bulb DIA. • Bulb length Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Standard Range g Bulb Dia.$Length Minimum graduation d (d1) g $ L (L) With one contact With one contact With two contact -30 ~ 50 2 -30 ~ 120 2 -20 ~ 100 2 -10~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 ~ 600 10 ~ 650 20 10 (15) 400 $ (400) 200 $ (200) 200 $ (300) 400 $ (500) 10 (15) 10 (15) 400 $ (500) 400 $ (400) 300 $ (300) 200 $ (300) 200 $ (200) 150 $ (150) 150 $ (150) 100 $ (150) 100 $ (100) 100 $ (100) 100 $ (100) 100 $ (100) 10 (15) 500 $ (500) 300 $ (300) 400 $ (400) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) 410 (430) 210 (230) 265 (285) 305 (325) 160 (180) 200 (220) 390 (410) - - - - - - $ $ $ $ $ $ $ $ $ $ $ 500 (500) 400 (400) 400 (400) 300 (300) 200 (300) 150 (200) 150 (150) 100 (150) 100 (100) 100 (100) 100 (100) 410 (430) 320 (340) 265 (285) 210 (230) 170 (190) 135 (155) 120 (140) 90 (110) 75 (95) 65 (85) 65 (85) 390 (410) 305 (325) 240 (260) 200 (220) 160 (180) 130 (150) 105 (125) 95 (115) 75 (95) 60 (80) 55 (75) 55 (75) d=12 DIA. 215 115 145 270 335 270 215 170 145 115 95 80 70 55 50 45 40 With tne contact (Not available to 100mm Dia.) d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 180 (200) 100 (120) 120 (140) 225 (245) 285 (305) 225 (245) 180 (200) 145 (165) 120 (140) 100 (120) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 135 (155) 75 (95) 90 (110) 170 (190) 210 (230) 170 (190) 135 (155) 110 (130) 90 (110) 75 (95) 65 (85) 55 (75) 50 (70) 40 (60) 40 (60) 40 (60) 40 (60) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) 320 (340) 410 (430) 430 (450) 240 (260) 305 (325) - - - - - - - 390 - 410 (430) 320 (340) 245 (265) 200 (220) 155 (175) 125 (145) 105 (125) 90 (110) 85 (105) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 15 d=12 DIA. 430 (450) 355 (375) 305 (325) 240 (260) 185 (205) 150 (170) 120 (140) 100 (120) 80 (100) 75 (95) 70 (90) 295 170 215 390 295 250 215 170 130 110 85 75 60 55 50 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 250 (270) 145 (165) 180 (200) 330 (350) 185 (205) 110 (130) 135 (155) 240 (260) 340 (360) 240 (260) 185 (205) 155 (175) 135 (155) 110 (130) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 330 (350) 250 (270) 210 (230) 180 (200) 145 (165) 115 (135) 95 (115) 75 (95) 65 (85) 55 (75) 50 (70) 45 (65) Max. d=8 DIA., 16 DIA. 1000 d=10 DIA., 12 DIA. 13 13 DIA. 3000 EXPLOTION-PROOF THERMOMETER WITH MICRO SWITCH 1 TD 25 Liquid filled dial thermometer #Dimension Terminal box 175 221 15 4-10 DIA. Mounting hole 40 ° 40° P.C.D.230 157 (160) 62 214 DIA. 25 (75) Flame-proof packing type 105 165 Setting positioning axis 80 115 Applicable model d2G4 Labor ministry inspection No. No.24201 Weight Approx.12kg (Indicator part) Conduit type Manufacturing range Indication dial Use switch Accuracy #Specification -70 ~ 300g With local indicator JIS C 4505 Industrial switch Number of contacts One contact, Two contact Setting Lead length Case Wetted parts Compensation Connection Flange Indication Within ±2% F.S. Reproductibity Setting Dead band Electric rating Resistance load Within 2% F.S. Within ±3% F.S. 125V 250V 30V 125V Within 4% F.S. External adjustment Ambient 1 • 2 • 3 • 4 • 5 • 8 • 10 • 15 • 20 (m) Within ±2% F.S./15deg Standard 3m temperature error Max. 20m Construction: Drip-proof • equivalent to IP54, Material: AC7A, Finishing : Glay AC5A AC5A DC5A DC0.4A Inductive load ( Power factor 0.75 ) Time-contact 7ms or less 125V 250V 30V 125V AC4A AC4A DC4A DC0.4A Bulb: 304st.st., Connection • Flange: 304st.st. Lead compensation R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g -70 ~ 50 2 -70 ~ 100 5 -50 ~ 50 2 -30 ~ 50 2 -20 ~ 100 2 -10~ 100 2 -10~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Standard Bulb Dia.$Length d (d1) 10 (15) $ L (L) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 150 (200) 150 (150) 150 (200) 200 (200) 150 (200) 150 (200) 300 (300) 300 (300) 300 (300) 200 (300) 200 (200) 150 (200) 150 (150) 100 (150) 100 (150) 100 (150) 160 (185) 125 (150) 180 (205) 215 (240) 160 (185) 170 (195) 265 (290) 355 (380) 315 (340) 245 (270) 205 (230) 180 (205) 155 (180) 110 (135) 100 (125) 90 (115) 130 (155) 105 (130) 145 (170) 170 (195) 130 (155) 135 (160) 210 (235) 270 (295) 245 (270) 195 (220) 165 (190) 145 (170) 125 (150) 95 (120) 85 (110) 80 (105) d=12 DIA. 100 85 110 130 100 105 155 195 180 145 125 110 100 75 70 65 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 16 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 90 (115) 75 (100) 100 (125) 115 (140) 90 (115) 95 (120) 135 (160) 170 (195) 155 (180) 125 (150) 110 (135) 100 (125) 90 (115) 70 (95) 65 (90) 60 (85) 75 (100) 65 (90) 80 (105) 95 (120) 75 (100) 80 (105) 105 (130) 135 (160) 120 (145) 100 (125) 90 (115) 80 (105) 75 (100) 60 (85) 60 (85) 55 (80) Max. 500 EXPLOTION-PROOF THERMOMETER WITH MICRO SWITCH 2 TD 21 Mercury filled dial thermometer #Dimension Terminal box 175 221 15 40° 4-10 DIA. Mounting hole 40 ° (157) (160) 214DIA. P.C.D. 230 Flame-proof packing type 165 105 115 Applicable model d2G4 Labor ministry inspection No. No.24200 Weight Approx11.5kg(Indicator part) Conduit type Manufacturing range Indication dial Accuracy #Specification -50 ~ 650g With local indicator Use switch JIS C 4505 Industrial switch Number of contacts One contact, Two contact Setting 1 • 2 • 3 • 4 • 5 • 8 • 10 (m) Setting Dead band Internal adjustment Lead length Indication Within ±2%F.S. Reproductibity standard 3m Electric rating Resistance load Within 2%F.S. Within ±4%F.S. 125V 250V 30V 125V Within 8%F.S. Ambient Within ±2%F.S./15deg temperature error AC5A AC5A DC5A CD0.4A Inductive load ( Power factor 0.75 ) Time-contact 7ms or less 125V 250V 30V 125V Max. 10m AC4A AC4A DC4A DC0.4A Construction: Drip-proof • equivalent to IP54, Material: AC7A, Finishing : Glay case Wetted parts Bulb: 304st.st., Connection • Flange: 304st.st. Compensation Bimetal compensation R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. Connection Flange JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2, 1/2NPT (Connection) Connection Slide type is not available with 16 Dia. bulb. #Range • Bulb DIA. • Bulb length Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length standard Range Minimum graduation g g Bulb Dia.$Length d (d1) $ L (L) With one contact With one contact With two contact -30 ~ 50 2 -30 ~ 120 2 -20 ~ 100 2 -10~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 ~ 600 10 ~ 650 20 10 (15) 400 $ (400) 200 $ (200) 200 $ (300) 400 $ (500) 10 (15) 10 (15) 400 $ (500) 400 $ (400) 300 $ (300) 200 $ (300) 200 $ (200) 150 $ (150) 150 $ (150) 100 $ (150) 100 $ (100) 150 $ (150) 150 $ (150) 150 $ (150) 10 (15) 500 $ (500) 300 $ (300) 400 $ (400) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) 410 (430) 210 (230) 265 (285) 305 (325) 160 (180) 200 (220) 390 (410) - - - - - - 500 $ (500) 400 $ (400) 400 $ (400) 300 $ (300) 200 $ (300) 150 $ (200) 150 $ (150) 100 $ (150) 100 $ (100) 100 $ (100) 100 $ (100) 410 (430) 320 (340) 265 (285) 210 (230) 170 (190) 135 (155) 120 (140) 90 (110) 75 (95) 65 (85) 65 (85) 390 (410) 305 (325) 240 (260) 200 (220) 160 (180) 130 (150) 105 (125) 95 (115) 75 (95) 60 (80) 55 (75) 55 (75) d=12 DIA. 215 115 145 270 335 270 215 170 145 115 95 80 70 55 50 45 40 d=16 DIA. (d1=23 DIA.) 180 (200) 100 (120) 120 (140) 225 (245) 285 (305) 225 (245) 180 (200) 145 (165) 120 (140) 100 (120) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 135 (155) 75 (95) 90 (110) 170 (190) 210 (230) 170 (190) 135 (155) 110 (130) 90 (110) 75 (95) 65 (85) 55 (75) 50 (70) 40 (60) 40 (60) 40 (60) 40 (60) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) d=12 DIA. 320 (340) 410 (430) 430 (450) 240 (260) 305 (325) - - - - - - - 390 - 410 (430) 320 (340) 245 (265) 200 (220) 155 (175) 125 (145) 105 (125) 90 (110) 85 (105) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 17 Max. With tne contact d=13 DIA. (d1=19 DIA.) 430 (450) 355 (375) 305 (325) 240 (260) 185 (205) 150 (170) 120 (140) 100 (120) 80 (100) 75 (95) 70 (90) 295 170 215 390 295 250 215 170 130 110 85 75 60 55 50 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 250 (270) 145 (165) 180 (200) 330 (350) 185 (205) 110 (130) 135 (155) 240 (260) 340 (360) 240 (260) 185 (205) 155 (175) 135 (155) 110 (130) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 330 (350) 250 (270) 210 (230) 180 (200) 145 (165) 115 (135) 95 (115) 75 (95) 65 (85) 55 (75) 50 (70) 45 (65) d=8 DIA., 16 DIA., 1000 d=10 DIA., 12 DIA., 13 DIA. 3000 THRMOMETER WITH MICRO SWITCH FOR TRANSFORMER 1 TX 54 • 56 Mercury filled dial thermometer • Waterproof and moisture resistance type TX54 • 100 DIA. TX56 • 150 DIA. Armored tube b 4-7 DIA. Mounting hole D b 4-10 DIA. Mounting hole P.C.D. D3 w a P.C.D.D3 n h D DIA. D w Setting positioning axis Setting positioning axis Model Dial size TX54 100 Dimension D D3 125 126 Model Dial size b W h 87.5 4 112.5 TX56 150 Dimension D D3 a b W h 188 180 23 90 7 215 Manufacturing range Use switch Accuracy #Specification -30 ~ 650g JIS C 4505 Industrial switch Number of contacts One contact, Two contact Setting Max. pointer Max.lead length case Wetted parts Compensation Connection Flange Internal adjustment Indication Within ±2% F.S. Reproductibity Setting Dead band Option Electric rating Within 2% F.S. Resistance load 250V AC3A 125V DC0.4A Inductive load 2000V AC1 minute Insulation resistance It is more than 500V DC 100MΩ with megger Within ±4% F.S. Within 8% F.S. Ambient Within ±2% F.S./15deg temperature error 5m (standard 3m) Construction: Water-proof • equivalent to IP65 , Material: Alminium alloy, Finishing: Black Bulb: 304st.st., Connection • Flange: 304st.st. Bimetal compensation R1/2 (PT) , R3/4 (PT) , 1 /2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. #Range • Bulb DIA. • Bulb length Range g Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Minimum graduation g d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) d=12 DIA. d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) -30 ~ 120 2 120 (140) 95 (115) 70 60 (80) -20 ~ 100 2 150 (170) 120 (140) 85 75 (95) 60 (80) 0 ~ 100 2 180 (200) 140 (160) 100 85 (105) 65 (85) ~ 120 2 150 (170) 120 (140) 85 75 (95) 60 (80) ~ 150 2 120 (140) 95 (115) 70 60 (80) 50 (70) ~ 200 5 100 (120) 80 (100) 60 55 (75) 45 (65) ~ 300 5 70 (90) 60 (80) 45 40 (60) 40 (60) ~ 500 10 55 (75) 45 (65) 40 40 (60) 40 (60) ~ 650 20 45 (65) 40 (60) 40 40 (60) 40 (60) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 18 Max. 50 (70) d=8 DIA., 16 DIA. 1000 d=10 DIA., 12 DIA., 13 DIA. 3000 THRMOMETER WITH MICRO SWITCH FOR TRANSFORMER2 TX 81 Liquid filled dial thermometer • Waterproof and moisture resistance type #Dimension Armored tube b E 4-10 DIA. Mounting hole a Setting positioning axis Setting pointer h E1 D DIA. w Dimension Model Dial size TX81 150 D E E1 a b W h 188 127 152 23 105 7 206 Manufacturing range Use switch Accuracy #Specification -70 ~ 300g JIS C 4505 Industrial switch Number of contacts One contact ~ Four contact Setting Max. pointer Max.lead length Cace Wetted parts Compensation Connection Flange Internal adjustment Indication Within ±2% F.S. Reproductibity Setting Dead band Electric rating Within 2% F.S. Resistance load Within ±4% F.S. 250V AC10A Inductive load Within 7% F.S. 125V DC0.6A 2000v AC 1minute Insulation resistance 20m (standard 3m) It is more than 500V DC 100MΩ with megger Construction: Water-proof • equivalent to IP65, Material: Alminium alloy, Finishing: Black Standard Ambient Within ±2% F.S./ 15deg temperature error Bulb: 304st.st., Connection • Flange: 304st.st. Lead compensation R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150R, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) d=12 DIA. d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) -70 ~ 100 5 125 (150) 105 (130) 85 75 (100) 65 (90) -50 ~ 50 2 180 (205) 145 (170) 110 100 (125) 80 (105) -20 ~ 100 2 160 (185) 130 (155) 100 90 (115) 75 (100) 0 ~ 50 1 355 (380) 270 (295) 195 170 (195) 135 (160) ~ 100 2 205 (230) 165 (190) 125 110 (135) 90 (115) ~ 120 2 180 (205) 145 (170) 110 100 (125) 80 (105) 75 (100) ~ 150 2 155 (180) 125 (150) 100 90 (115) ~ 200 5 110 (135) 95 (120) 75 70 (95) 60 (85) ~ 300 5 90 (115) 80 (105) 65 60 (85) 55 (80) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 19 Max. 500 THERMOMETER WITH CONTACT SWITCH /INDOOR • REMOTE TYPE1 TK 54 • 56 Liquid filled dial thermometer • TJ 54 • 56 Mercury filled dial thermometer Surface mounting #Dimension Stiing pointer b 3-5.5DIA. Mounting hple w D DIA. D1 DIA. P.C.D. D3 Model Dial size TJ54 TK54 TJ56 TK56 Dimension D3 b W C 128 115 78 3 (111) 178 165 85 4 (137) D D1 100 112 150 165 Gasket bore 9 DIA. Setting positioning axis c TK 64 • 66 Liquid filled dial thermometer • TJ 64 • 66 Mercury filled dial thermometer Panel mounting (Mounting hole ) #Dimension (46) b a Setting pointer Gasket bore. 9 DIA. D4 DIA. D DIA. D1 DIA. w 3-5.5DIA. Mounting hole P.C.D. D3 Setting positioning axis TK 74 • 76 Liquid filled dial thermometer • TJ 74 • 76 Mercury filled dial thermometer Panel mounting (Mounting clamp) b Setting pointer Setting pointer (46) Gasket bore. 9 DIA. a D DIA. D4 DIA. #Dimension Settting positioninf axis Model Dial size TJ64 • TJ74 TK64 • TK74 TJ66 • TJ76 TK66 • TK76 Dimension D3 D4 a b W 100 112 136 122 104 19 79 3 150 165 192 178 158 21 85 4 D D1 Manufacturing range TK 53 • 70 ~ 500g TJ 53 • ~ 650g Use switch Contact switch (Open type low contact) Number of contacts One contact, Two contact Setting TK33 Lead length TJ33 Case Wetted parts Connection Flange Accuracy #Specification Indication Within ±2% F.S. Reproductibity Setting Within 2% F.S. Within ±3% F.S. Electric rating Resistance load 100V AC0.5A 200V AC0.25A 100V DC0.05A 200V DC0.025A External adjustment Dead band Within ±4% F.S. 1 • 2 • 3 • 4 • 5 • 8 • 10 • 15 • 20 (m) Standard 3m Ambient Within ±2% F.S./ 15deg Bimetal compenstion 5m max. temperature error (350g or over 30m) Bimetal compenstion TJ34, TK34 Lead compenstion 20m max. 1 • 2 • 3 • 4 • 5 • 8 • 10 • 15 • 20 (m) Standard 3 m Compenstion TJ36, TK36 Bimetal compenstion • Lead compenstion Bimetal compenstion 20 m max. In case of more than 350g only bimetal compensation type. Lead compenstion 50 m max. Construction: Indoor use • equivalent to IP32, T354: ADC12, Others: AC7A, Finishing: Black Bulb: 304st.st., Connection • Flange: 304st.st. R1/2 (PT) , R3/4 (PT) , 1/2NPT, G1/2B (PF) , G3/4B ([F) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type: R1/2,1/2NPT (Connection) 20 Slide type is not available with 16 Dia. bulb. THERMOMETER WITH CONTACT SWITCH/INDOOR • REMOTE TYPE2 #Range • Bulb DIA. • Bulb length TK 5 • 6 • 7 (Liquid filled dial thermometer • With contact switch) Range g Minimum graduation g -70 ~ 50 2 -70 ~ 100 5 -50 ~ 50 2 -30 ~ 50 2 -20 ~ 100 2 -10 ~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 d (d1) 10 (15) Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Standard Bulb Dia.$Length $ L (L) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 200 (200) 200 (200) 50 (75) 40 (65) 55 (80) 65 (90) 50 (75) 70 (95) 95 (120) 70 (95) 65 (90) 55 (80) 50 (75) 40 (65) 40 (65) 40 (65) 40 (65) 230 (255) 230 (255) 45 (70) 40 (65) 45 (70) 55 (80) 45 (70) 60 (85) 75 (100) 60 (85) 55 (80) 45 (70) 45 (70) 40 (65) 40 (65) 40 (65) 40 (65) 170 (195) 170 (195) d=12 DIA. 40 40 40 45 40 50 60 50 45 40 40 40 40 40 40 120 120 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 45 (70) 50 (75) 45 (70) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 100 (125) 100 (125) 50 (75) 40 (65) 55 (80) 40 (65) 50 (75) 40 (65) 45 (70) 40 (65) 40 (65) 55 (80) 50 (75) 40 (65) 40 (65) 40 (65) 40 (65) 80 (105) 80 (105) TJ 5 • 6 • 7 (Mercury filled dial thermometer • With contact switch) Range g Minimum graduation g -30 ~ 50 2 -30 ~ 120 2 -20 ~ 100 2 -10 ~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 ~ 600 10 ~ 650 20 Standard d (d1) 10 (15) $ L (L) d=8 (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 200 (200) 100 (150) 200 (200) 300 (300) 300 (300) 300 (300) 200 (200) 200 (200) 200 (200) 100 (150) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 210 (230) 120 (140) 145 (165) 290 (310) 360 (380) 290 (310) 210 (230) 170 (190) 145 (165) 120 (140) 90 (110) 75 (95) 70 (90) 60 (80) 50 (70) 45 (65) 45 (65) 160 (180) 95 (115) 110 (130) 220 (240) 270 (290) 220 (240) 160 (180) 130 (150) 110 (130) 95 (115) 75 (95) 60 (80) 60 (80) 50 (70) 40 (60) 40 (60) 40 (60) d=12 DIA. 115 70 80 155 190 155 115 95 80 70 55 50 45 40 40 40 40 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 21 500 d=8 DIA., 16 DIA. 1000 d=10DIA., 12DIA., 13DIA. 3000 Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length Bulb Dia.$Length Max. d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 100 (120) 60 (80) 70 (90) 130 (150) 160 (180) 130 (150) 100 (120) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 75 (95) 50 (70) 55 (75) 100 (120) 120 (140) 100 (120) 75 (95) 65 (85) 55 (75) 50 (70) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) Max. d=8 DIA., 16 DIA. 1000 d=10 DIA., 12 DIA., 13 DIA. 3000 EXPLOTION-PROOF THERMOMETER WITH CONTACT SWITCH 1 TD 10 Liquid filled dial thermometer $Dimension Terminal box 175 221 15 4-10 DIA. Mounting hole 40° 40° (160) (157) 214 DIA. P.C.D. 230 Flame-proof packing type 165 105 115 80 Applicable model d2G4 Labor ministry inspection No. No.24199 (TD11Model applied product) Weight Approx.11kg (Indicator part) Conduit type Manufacturing range Indication dial Use switch Accuracy #Specification -70 ~ 500g With local indicator Contact switch (Open type low contact) Number of contacts One contact, Two contact Setting Lead length Case Wetted parts Compensation Connection Flange Electric rating Within 2% F.S. Resistance load Within ±3% F.S. 100V 200V 100V 200V Within 4% F.S. Ambient Within ±2% F.S./15deg temperature error Standard 3m Max. 5m, 350g or over. 30m Bulb:304st.st., Connection • Flange:304st.st. Bimetal compensation R1/2 (PT), R3/4 (PT), 1/2NPT, G1/2B (PF), G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Union type, Slide type Double socket union type:R1/2,1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. With thermowell Double socket slide type:R1/2,1/2NPT (Connection) #Range • Bulb DIA. • Bulb length Range g AC0.5A AC0.25A DC0.05A DC0.025A Construction : Drip-proof • equivalent to IP54, Material:AC7A, Finishing :Glay Without thermowell Connection Setting Dead band Internal adjustment 1 • 2 • 3 • 4 • 5 (m) Indication Within ±2% F.S. Reproductibity Minimum graduation g -70 ~ 50 2 -70 ~ 100 5 -50 ~ 50 2 -30 ~ 50 2 -20 ~ 100 2 -10 ~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 Value in parenthesis is the case with thermowell. Bulb length (L)mm Minimum insertion length Standard Bulb Dia.$Length d (d1) 10 (15) $ L (L) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 200 (200) 200 (200) 50 (75) 40 (65) 55 (80) 65 (90) 50 (75) 70 (95) 95 (120) 70 (95) 65 (90) 55 (80) 50 (75) 40 (65) 40 (65) 40 (65) 40 (65) 230 (255) 230 (255) 45 (70) 40 (65) 45 (70) 55 (80) 45 (70) 60 (85) 75 (100) 60 (85) 55 (80) 45 (70) 45 (70) 40 (65) 40 (65) 40 (65) 40 (65) 170 (195) 170 (195) d=12 DIA. 40 40 40 45 40 50 60 50 45 40 40 40 40 40 40 120 120 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 22 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 45 (70) 50 (75) 45 (70) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 40 (65) 100 (125) 100 (125) 50 (75) 40 (65) 55 (80) 40 (65) 50 (75) 40 (65) 45 (70) 40 (65) 40 (65) 55 (80) 50 (75) 40 (65) 40 (65) 40 (65) 40 (65) 80 (105) 80 (105) Max. 500 d=8 DIA., 16 DIA. 1000 d=10 DIA., 12 DIA., 13 DIA. 3000 EXPLOTION-PROOF THERMOMETER WITH CONTACT SWITCH 2 TD 11 Mercury filled dial thermometer #Dimension Terminal box 175 221 15 4-10 DIA. Mounting hole 40° 40° (157) (160) 214 DIA. P.C.D. 230 Flame-proof packing type 165 105 80 115 Applicable model d2G4 Labor ministry inspection No. No.24199 Weight Approx.11kg (Indicator part) Conduit type Manufacturing range Indication dial Use switch Accuracy #Specification -50 ~ 650g With local indicator Contact switch (Open type low contact) Number of contacts One contact, Two contact Setting Lead length Case Wetted parts Compensation Connection Flange Electric rating Within 2% F.S. Resistance load Within ±3% F.S. 100V 200V 100V 200V Within 4% F.S. Ambient Standard 3m temperature error Within ±2% F.S./15deg Max. 20m Bulb: 304st.st., Connection • Flange: 304st.st. Bimetal compensation R1/2 (PT), R3/4 (PT), 1/2NPT, G1/2B (PF), G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Union type, Slide type Double socket union type:R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. With thermowell Double socket slide type:R1/2, 1/2NPT (Connection) #Range • Bulb DIA. • Bulb length Range g AC0.5A AC0.25A DC0.05A DC0.025A Construction: Drip-proof • equivalent to IP54 , Material: AC7A, Finishing: Glay Without thermowell Connection Setting Dead band Internal adjustment 1 • 2 • 3 • 4 • 5 • 8 • 10 (m) Indication Within ±2% F.S. Reproductibity Minimum graduation g -30 ~ 50 2 -30 ~ 120 2 -20 ~ 100 2 -10 ~ 50 1 0 ~ 50 1 ~ 60 1 ~ 80 2 ~ 100 2 ~ 120 2 ~ 150 2 ~ 200 5 ~ 250 5 ~ 300 5 ~ 400 10 ~ 500 10 ~ 600 10 ~ 650 20 Value in parenthesis is the case with thermowell. Bulb length (L)mm Minimum insertion length Standard Bulb Dia.$Length d (d1) 10 (15) $ L (L) d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 200 (200) 100 (150) 200 (200) 300 (300) 300 (300) 300 (300) 200 (200) 200 (200) 200 (200) 100 (150) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 210 (230) 120 (140) 145 (165) 290 (310) 360 (380) 290 (310) 210 (230) 170 (190) 145 (165) 120 (140) 90 (110) 75 (95) 70 (90) 60 (80) 50 (70) 45 (65) 45 (65) 160 (180) 95 (115) 110 (130) 220 (240) 270 (290) 220 (240) 160 (180) 130 (150) 110 (130) 95 (115) 75 (95) 60 (80) 60 (80) 50 (70) 40 (60) 40 (60) 40 (60) d=12 DIA. 115 70 80 155 190 155 115 95 80 70 55 50 45 40 40 40 40 Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 23 d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) 100 (120) 60 (80) 70 (90) 130 (150) 160 (180) 130 (150) 100 (120) 85 (105) 70 (90) 60 (80) 50 (70) 45 (65) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 75 (95) 50 (70) 55 (75) 100 (120) 120 (140) 100 (120) 75 (95) 65 (85) 55 (75) 50 (70) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) 40 (60) Max. d= 8 DIA., 16 DIA. 1000 d=10 DIA., 12 DIA., 13 DIA. 3000 THRMOMETER WITH CONTACT SWITCH FOR TRANSFORMER 1 TW 84 Liquid filled dial thermometer • Indoor use #Dimension 3-5.5 DIA. Mounting hole Setting pointer b w D DIA. D1 DIA. P.C.D. D3 Setting positionaxis Armored tube Model Dimension Dial size TW84 100 D D1 D3 b W 112 134 124 78 3.5 Manufacturing range Use switch Accuracy #Specification -70 ~ 500g Contact switch (Open type low contact) Number of contacts One contact Setting Max. pointer Max. lead length Case Wetted parts Compensation Connection Flange Internal adjustment Indication Within ±2% F.S. Reproductibity Setting Dead band Option Electric rating Within 2% F.S. Resistance load 200V AC 0.25A 200V DC 0.025A Withstand voltage * 1000V AC 1minute Insulation resistance It is more than 500V DC 100MΩ with megger Within ±4% F.S. Within 7% F.S. Ambient Within ±2% F.S./15deg temperature error 5m (Standard 3m) Construction: Indoor use • equivalent to IP43, Material: Alminium alloy, Finishing: Black Bulb: 304st.st., Connection • Flange: 304st.st. Bimetal compensation R1/2 (PT), R3/4 (PT), 1/2NPT, G1/2B (PF), G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type: R1/2, 1/2NPT (Connection) With thermowell Double socket slide type:R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. • Apply the contact contactor in normal open condition. • In the case of 2 contact point type, as a common pole exists, independent 2 circuits are not obtained. * 2000V AC 1minute for transformer application. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g Value in parenthesis is the case with thermowell. Bulb length (L) mm Minimum insertion length d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) d=12 DIA. d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) -70 ~ 100 5 40 (65) 40 (65) 40 40 (65) 40 (65) -20 ~ 100 2 50 (75) 45 (70) 40 40 (65) 50 (75) 0 ~ 50 1 95 (120) 75 (100) 60 50 (75) 45 (70) ~ 100 2 55 (80) 45 (70) 40 40 (65) 55 (80) ~ 120 2 50 (75) 45 (70) 40 40 (65) 50 (75) ~ 150 2 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 200 5 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 300 5 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 500 10 230 (255) 170 (195) 120 100 (125) 80 (105) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 24 Max. 500 d=8 DIA.,16 DIA. d=10 DIA.,12 DIA.,13 DIA. 1000 3000 * Models of which temperature sensing portio is partially flat can be mounfactured. THRMOMETER WITH CONTACT SWITCH FOR TRANSFORMER 2 TW 54 Liquid filled dial thermometer • Waterproof and moisture resistance type #Dimension Armored tube 4-7 DIA. Mounting hole P.C.D. D3 Setting pointer b h D w Dimension Model Dial size TW 54 100 D D3 b W h 125 126 87.5 4 112.5 Manufacturing range Use switch Accuracy #Specification -70 ~ 500g Contact switch (Open type low contact) Indication Within ±2% F.S. Electric rating Within 2% F.S Resistance load 200V AC 0.25A 200V DC 0.025A Setting Number of contacts One contactf • Two contact Within ±4% F.S. Withstand voltage Setting Internal adjustment Dead band Within 7% F.S. * 1000V AC 1minute Ambient Max. pointer Option Insulation resistance Within ±2% F.S./15deg temperature error Max. lead length 5m (Standard 3m) It is more than 500V DC 100MΩ with megger Case Construction: Water-proof • equivalent to IP65, Material: Alminium alloy, Finishing: Black Wetted parts Compensation Connection Flange Reproductibity Bulb: 304st.st., Connection • Flange: 304st.st. Bimetal compensation R1/2 (PT), R3/4 (PT), 1/2NPT, G1/2B (PF), G3/4B (PF) 1/2 is not available with 16 Dia. bulb and 19 Dia., 23 Dia. thermowell. JIS10K20ARF, JIS10K25ARF, ANSI1B150RF, ANSI1B300RF Without thermowell Connection Union type, Slide type Double socket union type:R1/2, 1/2NPT (Connection) With thermowell Double socket slide type:R1/2, 1/2NPT (Connection) Slide type is not available with 16 Dia. bulb. • Apply the contact contactor in normal open condition. • In the case of 2 contact point type, as a common pole exists, independent 2 circuits are not obtained. * 2000V AC 1minute for transformer application. #Range • Bulb DIA. • Bulb length Range g Minimum graduation g Value in parenthesis is the case with thermowell. Bulb length (L)mm Minimum insertion length d=8 DIA. (d1=12 DIA.) d=10 DIA. (d1=15 DIA.) d=12 DIA. d=13 DIA. (d1=19 DIA.) d=16 DIA. (d1=23 DIA.) -70 ~ 100 5 40 (65) 40 (65) 40 40 (65) -20 ~ 100 2 50 (75) 45 (70) 40 40 (65) 50 (75) 0 ~ 50 1 95 (120) 75 (100) 60 50 (75) 45 (70) ~ 100 2 55 (80) 45 (70) 40 40 (65) 55 (80) ~ 120 2 50 (75) 45 (70) 40 40 (65) 50 (75) ~ 150 2 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 200 5 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 300 5 40 (65) 40 (65) 40 40 (65) 40 (65) ~ 500 10 230 (255) 170 (195) 120 100 (125) 80 (105) Note • Above length is the minimum necessary length of bulb to be inserted into the fluid to be measured. • Bulb length should be over the above length and specify 5mm steps. • In case of plain type of bulb, minimum length to be added 40mm to the above length. 25 Max. 40 (65) 500 d=8 DIA., 16 DIA. d=10 DIA., 12 DIA., 13 1000 DIA.3000 Type No. Constituton 1 Please specify Type No., each spcification and temperature range when ordering. (Note: For this Model, there is no applicable item for the figures X, but please specify X when ordering.) TF With micro switch • Liquid filled dial thermometer TE With micro switch • Mercury filled dial thermometer TK With contact switch • Liquid filled dial thermometer TJ 1 Thermowell • Inner connection 0 With contact switch • Mercury filled dial thermometer Mounting 1 With thermowell:W22 thread14 (Standard) 2 With thermowell:R1/2Double socket 3 With thermowell:1/2NPT Double socket 4 With thermowell:G1/2B Double socket 5 With thermowell:R3/4Double socket Direct/I stem type (100 DIA.) 5 Remote/Surface nounting 6 Remote/Panel (Mounting hole) 7 Without thermowell 1 Please refer to other page for thermowell. (SW33) Remote/Panel (Mounting clamp) 15 Document I stem type 150 Dia. and others direct type is available. Contact NKS for details. 3 Connection Mounting • Size 4 100 6 150 75 Dia. is available with electric contact. Contact NKS for details. 2 Connecting form 0 Union type 1 Slide type 4 0 R1/2 1 R3/4 2 1 3 G1/2B 4 G3/4B 5 JIS10K20ARF 6 JIS10K25ARF 7 ANSI1B150RF 0 Nil 1 Please specify your requirement. Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report. /2NPT 14 Other additional spec. 8 ANSI1B300RF A Fixing screw (W22 thread 14)union type only Z Plain type 0 Nil 1 Please specify your requirement. Case finishing • Dual scale with (f) Connection 316st.st. option. 12 Outlet for electric wire Plain type Bulb dend type is available. 0 12 Outlet for electric wire coduit type DIN 9 DIA. With contact switch. 3 PF3/4 Female (Standard) 2 PF1/2 Female A Rc1/2 B 1 /2NPT Female With micro switch. 1 2 3 Selection spec. 4 5 6 Additional Spec. (Option) 7 8 9 10 11 T 12 13 14 15 X Type No. 4 Range (g) 13 Treatment 1 0 ~ 50, 60, 80, 100, 120, 150 2 0 ~ 200, 250, 300 (Liquid filled type TF14 is not available) 0 3 0 ~ 400, 500 (Liquid filled type is not available) 1 Use no oil 4 0 ~ 600, 650 (Liquid filled type is not available) 2 Use no water 5 -10 ~ 50, -30 ~ 50, -50 ~ 50, -10 ~ 100 3 Use no oil • water 6 -70 ~ 50, -70 ~ 100 (Mercury filled type is not available) 7 -30 ~ 120, -20 ~ 100 10 Contact point type Please specify range & unit. 5 Bulb Dia. 1 d=8 Dia. 2 d=10 Dia. 3 d=12 Dia. Nil 6 Bulb length 1 H: Upper limit type with one contact 2 L: Lower limit type with one contact 3 HL: Upper & lower limit type with two contact 4 2H: Upper type with two contact 5 2L: Lower limit type with two contact (Contact type is not available.) 4 d=13 Dia. 5 d=16 Dia. 1 2 From min. insertion length to ~ 500mm Liquid filled type Max. 500mm 505 mm ~ 1000 (8 DIA., 16 DIA.) 3000 (Others) Mercury filled type only (Contact type is not available.) 9 Compensation Please specify bulb length. 1 Bimetal compensation (Micro liquid filled type is not available.) 2 Lead compensation (Micro mercury filled type is not available. Contact 100 DIA. is not available. Contact more than 350deg. impossibility. 7 Lead kind 9 Lead length 0 Nil (Direct type) 1 Capillary: 304st.st., Armored tube: 430st.st. 0 2 Capillary: 316st.st., Armored tube: 430st.st. 1 Less than 3m 3 Capillary: 304st.st., Armored tube: 430st.st.+PVC (Max. 100g) 2 Over 3m 4 Capillary: 316st.st., Armored tube: 430st.st.+PVC (Max.100g) Nil (Direct type) Please specify lead length. * When placing an order, check to confirm the specifications including a model, range, bulb, a lead parts, etc. and then select a model number. 26 Type No. Constituton 2 Please specify Type No., each spcification and temperature range when ordering. (Note: For this Model, there is no applicable item for the figures X, but please specify X when ordering.) TD Explotion-proof thermometer Mounting 15 Document 25 With micro switch • Liquid filled dial thermometer 21 With micro switch • Mercury filled dial thermometer 10 With contact switch • Liquid filled dial thermometer 11 With contact switch • Mercury filled dial thermometer 0 Nil 1 Please specify your requirement. Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report. 1 Thermowell • Inner connection 0 Without thermowell 1 With thermowell: W22 thread14 (Standard) 2 With thermowell: R1/2 Double socket 3 With thermowell: 1/2 NPT Double socket 4 1 5 14 Other additional spec. Nil 1 Please specify your requirement. Case finishing • Dual scale with (f) Connection 316st.st. option. With thermowell: G /2 Double socket With thermowell: R3/4 Double socket Please refer to other page for thermowell. (SW33) 2 Connecting form 0 Union type 1 Slide type 4 Plain type Bulb bend type is available. R /2 1 3 R /4 2 1 3 PF3/4 Female (Standard) 12 Outlet for electric wire In case of flame-proof packing type /2NPT 3 G1/2B 0 PF1/2 Female$10.5 4 G3/4B 1 PF1/2 Female$12 5 JIS10K20ARF 2 PF3/4 Female$10.5 6 JIS10K25ARF 3 PF3/4 Female$12 7 ANSI1B150RF 4 PF3/4 Female$14 ANSI1B300RF 5 PF3/4 Female$15.5 Fixing screw (W22 thread 14)union type only 6 PF3/4 Female$16.5 Plain type 7 PF1 Female$14 8 PF1 Female$15.5 9 PF1 Female$16.5 Z 3 1 0 A 2 12 Outlet for electric wire In case of conduit type 3 Connection 8 1 0 Selection spec. 4 5 6 7 8 9 10 11 12 Additional Spec. (Option) 13 14 15 T D Type No. 4 Range (g) 1 0 ~ 50, 60, 80, 100, 120, 150, 200, 250, 300 2 0 ~ 400, 500, 600, 650 (TD25is not available, TD10 650gis not available) 2 4 13 Treatment -10 ~ 50, -10 ~ 100, -20 ~ 100, -30 ~ 50, -50 ~ 50, -70 ~ 50, -70 ~ 100 (TD25 • 10 only) -10 ~ 50, -20 ~ 100, -30 ~ 50, -30 ~ 120 (TD21 • 11 only) Please specify range & unit. d=8 Dia. 2 d=10 Dia. 3 d=12 Dia. 4 d=13 Dia. 5 d=16 Dia. Nil 1 Use no oil 2 Use no water 3 Use no oil • water 11 Type of outlet 5 Bulb Dia. 1 0 1 Conduit type 3 Flame-proof packing type 6 Bulb length 1 From min. insertion length to ~ 500mm Liquid filled type Max. 500mm 2 505 mm ~ 1000 (8 DIA., 16 DIA.) 3000 (Others) Mercury filled type only 10 Contact point type 7 Lead kind Capillary:3 04st.st., Armored tube: 430st.st. 2 Capillary: 316st.st., Armored tube: 430st.st. 3 Capillary: 304st.st., Armored tube: 430st.st.+PVC (Max. 100g) 4 Capillary: 316st.st., Armored tube: 430st.st.+PVC (Max.100g) H: Upper limit type with one contact 2 L: Lower limit type with one contact 3 HL: Upper & lower limit type with two contact 4 2H: Upper limit type with two contact (TD10 • 11 is not available) 2L: Lower limit type with two contact (TD10 • 11 is not available) 5 Please specify bulb length. 1 1 9 Lead length 8 Lead length 1 Less than 3m 2 Over 3m 1 Bimetal compensation (TD21 • 10 • 11) 2 Lead compensation (TD25) Please specify lead length. * When placing an order, check to confirm the specifications including a model, range, bulb, a lead parts, etc. and then select a model number. 27 Type No. Constituton 3 Please specify Type No., each spcification and temperature range when ordering. (Note:For this Model, there is no applicable item for the figures X, but please specify X when ordering.) TX54 For transformer • With micro switch • Waterproof and moisture resistance type • Mercury filled dial thermometer, 100 DIA. TX56 For transformer • With micro switch • Waterproof and moisture resistance type • Mercury filled dial thermometer, 150 DIA. TX81 For transformer • With micro switch • Waterproof and moisture resistance type • Liquid filled dial thermometer, 150 DIA. TW54 For transformer • With contact switch • Waterproof and moisture resistance type • Liquid filled dial thermometer, 100 DIA. TW84 For transformer • With contact switch • Indoor type • Liquid filled dial thermometer, 100 DIA. 1 Thermowell • Inner connection 0 Without thermowell 1 With thermowell: W22 thread14 (Standard) 2 With thermowell: R /2 Double socket 3 1 With thermowell: /2 NPT Double socket 4 With thermowell: G1/2B Double socket 5 15 Document 1 3 Connection With thermowell: R3/4 Double socket Please refer to other page for thermowell. (SW33) 2 Connecting form R3/4 2 1 3 G1/2B 4 G3/4B 0 Nil 1 Please specify your requirement. /2NPT Union type 5 JIS10K20ARF 6 JIS10K25ARF 4 Plain type 7 ANSI1B150RF 3 Please specify your requirement. Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report. 1 Slide type 2 1 R1/2 1 1 Nil 0 0 Bulb dend type is available. 0 14 Other additional spec. Case finishing • Dual scale with (f) Connection 316st.st. option. 8 ANSI1B300RF A Fixing screw (W22 thread 14)union type only Z Plain type Selection spec. 4 5 6 7 12 Outlet for electric wire 8 9 2 PF1/2 (TX54 • TW54) 3 PF3/4 (TX56) 4 PF1/1 (TX81) 0 Terminal for communication (TW84) 10 12 11 T Additional Spec. (Option) 13 14 15 X Type No. 4 Range (g) 13 Treatment 1 0 ~ 50, 100, 120, 150, 200, 300 2 0 ~ 400, 500 (TW54 • 84) 0 3 0 ~ 500, 650 (TX54 • 56) 1 Use no oil 4 -10 ~ 50, -20 ~ 100, -30 ~ 50, -50 ~ 50, -70 ~ 50, -70 ~ 100 (TW54 • 84) 2 Use no water 3 Use no oil • water 5 -30 ~ 120, -20 ~ 100 (TX54 • 56) 6 Nil -20 ~ 100, -50 ~ 50, -70 ~ 100 (TX81) 10 Contact point type Please specify range & unit. 1 5 Bulb Dia. 1 d=8 Dia. 2 d=10 Dia. 3 d=12 Dia. 4 d=13 Dia. 5 d=16 Dia. 6 Bulb length 1 From min. insertion length to ~ 500mm Liquid filled type Max. 500mm 2 505 mm ~ 1000 (8 DIA., 16 DIA.) 3000 (Others) Mercury filled type only H: Upper limit type with one contact 2 L: Lower limit type with one contact 3 HL: Upper & lower limit type with two contact (TW84 is not available.) 2H: Upper limit type with two contact (TW54 • 84 is not available.) 2L: Lower limit type with two contact (TW54 • 84 is not available.) 4 5 9 Cpmpensation Please specify bulb length. 1 Bimetal compensation (TX54 • 56, TW54 • 84) 2 Lead compensation (TX81) 7 Lead kind 1 Capillary: 304st.st., Armored tube: 430st.st. 2 Capillary: 316st.st., Armored tube: 430st.st. 3 Capillary: 304st.st., Armored tube: 430st.st.+PVC (Max. 100g) 4 Capillary: 316st.st., Armored tube: 430st.st.+PVC (Max.100g) 8 Lead length 1 Less than 3m 2 Over 3m Please specify lead length. * When placing an order, check to confirm the specifications including a model, range, bulb, a lead parts, etc. and then select a model number. 28 THERMOWELL SPECIFICATION #Connection parts and dimension #Thermowell type,Size Standard type X Hex. Welding type S T Welding T Welding d1 DIA. Taper Screw J L M (10) Double socket type Drilled type (Straight) R (PT) T T d1 DIA. X Hex. S Screw type J (10) Standard type T T d2 DIA. W DIA. X Hex. Drilled type (Taper) Straight Screw 3 (mm) J T M (10) T W DIA. Double socket type X Hex. d1 DIA. Screw type Union type L M (25) J S W X M R21/ 18 8 - 27$31.2 43 R43/ 20 9.5 - 30$34.6 45 1 G /2 B 18 - 32 32$37 43 G3/4B 20 - 36 36$41.6 45 L Welding type Welding (25) M d1 DIA. (10) Welding Standard type L Drilled type (Straigh) Flange type JIS, ANSI, JPI 45 (10) Flange type Union type d1 DIA. Welding Double socket type L (10) d1 DIA. Welding d2 DIA. Drilled type (Taper) (25) 45 Note) Please refer to JIS, ANSI, JPI standard for flange size. L Bulb type 15 19 Drilled type Welding type Drilled type Welding type Drilled type Welding type Welding type Out dia (d1) 1 /2 3 /4 JIS, ANSI, JPI o o o o o o Drilled type o o o Welding type o o o Drilled type - o o Welding type - o o 23 DIA. Drilled type - o o 19 DIA./23 DIA. (Taper) Drilled type - o o 8.5 10.5 11 13.5 13.5 13.5 12 DIA. d DIA. 8 8 10 10 13 13 13 15 DIA. 19 DIA. 29 Mounting Flange Drilled type 8.5 304 st.st., 316 st.st., 316 L st.st., Titanium, Hastelloy-B, and Monel-metal are available. Coating is available with followings. Rubber, Kel-F, Teflon, Lead or Glass Thermowell with coating is flange type only. Screw (T) Welding type Inner dia (d2DIA.) #Thermowell material 1 Bulb Thermowell Standard Inner connection ( connection with thermometer )is W22 thread 14 or Rc1/2 Thermowell d DIA. Thermo -well 12 #Relation of Thermowell DIA. and connection 23, 19/23 (Taper) d2 DIA. Out dia (d1 DIA.) d1 DIA. #Relation of Thermowell and bulb. Type No. Constitution Please specify Type No., each spcification and temperature range when ordering. (Note: For this Model, there is no applicable item for the figures X, but please specify X when ordering.) 1 • 2Connection S W 1 Welding type S W 2 Drilled type S W 3 Drilled type 1 2 Straight W22 thread 14 Straight R 1/2 00 Screw Type,R1/2 01 Screw Type,R3/4 3 Straight 1/2 NPT 02 Screw Type,1/2NPT 4 5 Straight G 1/2 B Straight R 3/4 03 Screw Type,G1/2B 04 Screw Type,G3/4B 6 Taper W22thread14 05 Flange type,JIS10K20ARF 7 8 Taper R 1/2 Taper 1/2 NPT 06 Flange type,JIS10K25ARF 07 Flange type,ANSI1B150RF 9 5 Taper G 1/2 B Tape R 3/4 08 Flange type,ANSI1B300RF 0F Flange type,JIS10K15ARF 0G Flange type,JIS10K40ARF 0H Flange type,JIS10K50ARF Model 0W Flange type,JPI1B150RF 0X Flange type,JPI1B300RF Other screw • flange (TF,GF,MF,FMF,R) are avaibable, contact NKS for details. 3 Material 1 304 st.st. 2 316 st.st. 5 316 L st.st. Drilled type only. In case of Drilled type, special material titanium,hastelloy or other materials are available, contact NKS for details. Selection spec. Thermowell 1 2 3 4 5 Additional Spec. (Option) 6 7 8 9 15 10 S W X 11 X 12 13 X X 14 X Type No. 4 • 5Out dia 6 • 7 • 8LSize 12 Out dia12 DIA. 15 Out dia15 DIA. 001 ~ 100 001 ~ 100 19 Out dia19 DIA. 101 101 ~ 200 101 101 ~ 150 Welding type (mm) Drilled type (mm) 23 Out dia23 DIA. 201 201 ~ 300 151 151 ~ 200 AA Out dia 19/23 DIA. Flange type with Drilled type only. 301 301 ~ 400 201 201 ~ 250 401 401 ~ 500 251 251 ~ 300 501 501 ~ 600 301 301 ~ 350 601 601 ~ 700 351 351 ~ 400 701 701 ~ 800 401 401 ~ 450 801 801 ~ 900 451 451 ~ 500 901 901 ~ 1000 501 501 ~ 550 551 551 ~ 600 601 601 ~ 650 651 651 ~ 700 701 701 ~ 750 751 751 ~ 800 801 801 ~ 850 851 851 ~ 900 901 901 ~ 950 951 951 ~ 1000 • Please specify L size. • When required over 1000mm, please specify with 100mm steps. 30 9 Other additional spec. 0 Nil 1 Please specify your requirement. Bore option (Drilled type only) with plug chain. 15 Document 0 Nil 1 Please specify ypur requirement. Drawing one sheet, Mill sheet.
© Copyright 2026 Paperzz