B 7SR224 Relay A L1 A PH Fault L2 B PH Fault L3 C PH Fault L4 Gnd Fault L5 SEF L6 Lockout L7 Aux Power OK L8 Recloser OK L9 Open L15 All Prot’n OFF L10 Close L16 Inst Prot’n OFF Reclose ON L17 L11 Hot Line Tag ON L12 L18 L13 Gnd Fault L19 Prot’n OFF L14 SEF L20 Prot’n OFF C Trip & Reclose Item Description LED Button Description A MLFB model number L9 F1 Push-to-open recloser Recloser is OPEN B Ratings label L10 F2 Push-to-close recloser Recloser is CLOSED Reclose functionality is ON C Programming port LED Description L1 Phase A target L2 Phase B target L3 Phase C target L4 Ground fault target L5 Sensitive earth fault (SEF) target L6 Recloser is locked out L7 AC input power to control cubicle ok L8 Capacitors charged and system ready to reclose If associated LED is lit, status: L11 F3 Push-to-toggle reclose functionality ON/OFF L12 F4 Push-to-toggle hot line tag ON/OFF Hot line tag is ON L13 F5 Push-to-toggle ground fault protection ON/OFF Ground fault protection is OFF SEF protection is OFF L14 F6 Push-to-toggle SEF protection ON/OFF L15 F7 Push-to-toggle all protection ON/OFF All protection is OFF L16 F8 Push-to-toggle instantaneous protection ON/OFF Instantaneous protection is OFF L17 F9 User defined User defined L18 F10 User defined User defined L19 F11 User defined User defined L20 F12 Push-to-trip and reclose recloser ---- Item Description In CT secondary current (1 A for recloser) Fn 50 Hz/60 Hz (user defined) Vn Voltage supplied to relay from voltage sensors Vx Power supply voltage range (dc volts) BI Voltage to activate a binary input Config Firmware revision number Serial No. Serial number 01: 1/4/2012 Type 7SR224 Relay Name: Quick Reference Guide For Three-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 01-12 Scale: NONE Sheet: 1 of 4 Part No: 18-671-296-402 Issue/Rev: 01 Quick reference navigation tree guide for type 7SR relay Press enter. If LCD screen does not say “ENTER to CONTROL”, press the Cancel button until it does. This will not cause the recloser to operate. Control Mode Settings Mode Instrument Mode Fault Data CB: Open/Closed/Travel System Config Favorite Meters Fault 1 AR: Out of Service IN/OUT CT/VT Config Current Meters Fault 2 AR: Trip & Close Function Config Voltage Fault 3 AR: Trip & Lockout Current Prot’n Frequency Meters Fault 4 Hotline Working IN/OUT Voltage Prot’n Power Meters Fault 5 G/F Prot’n IN/OUT Supervision Energy Meters Fault 6 SGF Prot’n IN/OUT Control & Logic Directional Meters Fault 7 Inst Prot’n IN/OUT Input Config Thermal Meters Fault 8 Loss of Voltage IN/OUT Output Config Autoreclose Meters Fault 9 Battery Test Initiate Maintenance Loss of Voltage Meters Fault 10 Set Local Data Storage Maintenance Meters Set L or R Communications General Alarm Meters Set Remote Battery Condition Set Service Capacitor Condition Notes: For all arrows pointing push the , button. For all arrows pointing , Power Quality Meters push the button. Demand Meters Refer to page three for detailed “Settings Mode” tree. For all arrows pointing , Binary Input Meters push the button. Virtual Meters To go back one level, Comm Meters push the button. Misc Meters To select, Quick Logic Meters push the button. 01: 1/4/2012 Type 7SR224 Relay Name: Quick Reference Guide For Three-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 01-12 Scale: NONE Sheet: 2 of 4 Part No: 18-671-296-402 Issue/Rev: 01 Settings mode detailed tree Settings Mode System Config Establish system parameters, recloser name, active settings group, viewing/editing settings group and other parameters. CT/VT Config Establish current transformer (CT) and voltage transformer.(VT) parameters. Function Config Enable functions.. Current Prot’n Phase Overcurrent 67-N 51-N thru 51-4 50-1 thru 50-4 Voltage Cont O/C Cold Load Measured E/F 51-G thru 51G-4 50G1- thru 50G-4 Sensitive E/F 67-N 50SEF-1 thru 50SEF-4 Restricted E/F NPS Overcurrent 46IT 46DT Undercurrent Thermal Voltage Prot’n Phase U/O Voltage 27/59-1 thru 27/59-4 Vx U/O Voltage NPS Overvoltage 47-1 & 47-2 Neutral Overvoltage 59NIT 59NDT U/O Frequency 01: 1/4/2012 Type 7SR224 Relay Name: Quick Reference Guide For Three-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 01-12 Scale: NONE Sheet: 3 of 4 Part No: 18-671-296-402 Issue/Rev: 01 Supervision CB Fail Settings mode detailed tree VT Supervision CT Supervision Broken Conductor Trip CCT Supervision Inrush Detector Battery Test Capacitor Test Power Quality 27SAG 59SWELL Control & Logic Autorecloser Prot’n Autorecloser Config Manual Close Circuit Breaker Quicklogic Input Config Input Matrix Function Key Matrix Binary Input Config General Alarms Output Config Output Matrix Binary Output Config LED Config Pickup Config Maintenance CB Counters 1ˆ2T CB Wear Output Matrix Test Data Storage Communications 01: 1/4/2012 Type 7SR224 Relay Name: Quick Reference Guide For Three-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 01-12 Scale: NONE Sheet: 4 of 4 Part No: 18-671-296-402 Issue/Rev: 01
© Copyright 2026 Paperzz