Name: Similar To

B
A
L1
L2
Item
Description
A
MLFB model number
B
Ratings label
C
Programming port
LED
Description
L1
Relay self-health indicator
L2
Recloser is OPEN
L3
Recloser is CLOSED
L4
Recloser is LOCKED OUT
L5
Fault has occurred
L6
Ground fault has occurred
L7
Recloser is active
L8
Hot line tag active
L3
L4
L5
L9
Ground fault protection off
L10
Reclose sequence in process
L6
L7
L8
C
L9
L10
Item
Description
In
CT secondary current (1 A for recloser)
Fn
50 Hz/60 Hz (user defined)
Vx
Power supply voltage range (dc volts)
BI
Voltage to activate a binary input
01:
1/4/2012
Type 7SR11/7SR12 Relay
Name: Quick Reference Guide
For Single-Phase SDR Recloser
TGH 02/12
DR: _______
TGH 02/12
CH: _______
---AP: _______
Similar To:
Bulletin:
02-12
Scale:
NONE
Sheet:
1 of 4
Part No:
18-671-296-407
Issue/Rev:
01
Quick reference navigation tree guide
for type 7SR relay
Press enter.
If LCD screen does not say “ENTER to CONTROL”, press the Cancel button until it
does. This will not cause the recloser to operate.
Control Mode
Settings Mode
Instrument Mode
Fault Data
CB: Travelling
System Config
Favorite Meters
Fault 1
AR: Out of Service
CT/VT Config
Current Meters
Fault 2
AR: Trip & Reclose
Function Config
Thermal Meters
Fault 3
AR: Trip & Lockout
Current Prot’n
Autoreclose Meters
Fault 4
Hotline Working: IN/OUT
Control & Logic
Maintenance Meters
Fault 5
E/F IN/OUT
Input Config
General Alarm Meters
Fault 6
Inst Prot’n IN/OUT
CB Maintenance
Demand Meters
Fault 7
Data Storage
Binary Input Meters
Fault 8
Communications
Binary Output Meters
Fault 9
Virtual Meters
Fault 10
Communication Meters
Notes:
Miscellaneous Meters
For all arrows pointing
push the
,
button.
For all arrows pointing
push the
,
button.
For all arrows pointing
Refer to page three for
detailed “Settings Mode” tree.
push the
,
button.
To go back one level,
push the
button.
To select,
push the
button.
01:
1/4/2012
Type 7SR11/7SR12 Relay
Name: Quick Reference Guide
For Single-Phase SDR Recloser
TGH 02/12
DR: _______
TGH 02/12
CH: _______
---AP: _______
Similar To:
Bulletin:
02-12
Scale:
NONE
Sheet:
2 of 4
Part No:
18-671-296-407
Issue/Rev:
01
Settings Mode
System Config
Establish system parameters, recloser name, active settings group, viewing/editing settings group and other parameters.
CT/VT Config
Establish current transformer (CT) and voltage transformer.(VT) parameters.
Function Config
Enable functions..
Current Prot’n
Phase Overcurrent
50/51 Measurement RMS
Settings
mode
detailed
tree
51-1 thru 51-2
50-1 thru 50-2
Measured E/F
50G/51G Measurement RMS
51-G thru 51-4
51-G thru 51G-4
50G1- thru 50G-4
Control & Logic
Autorecloser Prot’n
Autorecloser Config
Manual Close
Circuit Breaker
Quicklogic
Input Config
Input Matrix
Binary Input Config
General Alarms
Output Config
Output Matrix
Binary Output Config
LED Config
Pickup Config
Trip Config
CB Maintenance
CB Counters
Output Matrix
Data Storage
Communications
01:
1/4/2012
Type 7SR11/7SR12 Relay
Name: Quick Reference Guide
For Single-Phase SDR Recloser
TGH 02/12
DR: _______
TGH 02/12
CH: _______
---AP: _______
Similar To:
Bulletin:
02-12
Scale:
NONE
Sheet:
3 of 4
Part No:
18-671-296-407
Issue/Rev:
01
This page left intentionally blank.
01:
1/4/2012
Type 7SR11/7SR12 Relay
Name: Quick Reference Guide
For Single-Phase SDR Recloser
TGH 02/12
DR: _______
TGH 02/12
CH: _______
---AP: _______
Similar To:
Bulletin:
02-12
Scale:
NONE
Sheet:
4 of 4
Part No:
18-671-296-407
Issue/Rev:
01