B A L1 L2 Item Description A MLFB model number B Ratings label C Programming port LED Description L1 Relay self-health indicator L2 Recloser is OPEN L3 Recloser is CLOSED L4 Recloser is LOCKED OUT L5 Fault has occurred L6 Ground fault has occurred L7 Recloser is active L8 Hot line tag active L3 L4 L5 L9 Ground fault protection off L10 Reclose sequence in process L6 L7 L8 C L9 L10 Item Description In CT secondary current (1 A for recloser) Fn 50 Hz/60 Hz (user defined) Vx Power supply voltage range (dc volts) BI Voltage to activate a binary input 01: 1/4/2012 Type 7SR11/7SR12 Relay Name: Quick Reference Guide For Single-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 02-12 Scale: NONE Sheet: 1 of 4 Part No: 18-671-296-407 Issue/Rev: 01 Quick reference navigation tree guide for type 7SR relay Press enter. If LCD screen does not say “ENTER to CONTROL”, press the Cancel button until it does. This will not cause the recloser to operate. Control Mode Settings Mode Instrument Mode Fault Data CB: Travelling System Config Favorite Meters Fault 1 AR: Out of Service CT/VT Config Current Meters Fault 2 AR: Trip & Reclose Function Config Thermal Meters Fault 3 AR: Trip & Lockout Current Prot’n Autoreclose Meters Fault 4 Hotline Working: IN/OUT Control & Logic Maintenance Meters Fault 5 E/F IN/OUT Input Config General Alarm Meters Fault 6 Inst Prot’n IN/OUT CB Maintenance Demand Meters Fault 7 Data Storage Binary Input Meters Fault 8 Communications Binary Output Meters Fault 9 Virtual Meters Fault 10 Communication Meters Notes: Miscellaneous Meters For all arrows pointing push the , button. For all arrows pointing push the , button. For all arrows pointing Refer to page three for detailed “Settings Mode” tree. push the , button. To go back one level, push the button. To select, push the button. 01: 1/4/2012 Type 7SR11/7SR12 Relay Name: Quick Reference Guide For Single-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 02-12 Scale: NONE Sheet: 2 of 4 Part No: 18-671-296-407 Issue/Rev: 01 Settings Mode System Config Establish system parameters, recloser name, active settings group, viewing/editing settings group and other parameters. CT/VT Config Establish current transformer (CT) and voltage transformer.(VT) parameters. Function Config Enable functions.. Current Prot’n Phase Overcurrent 50/51 Measurement RMS Settings mode detailed tree 51-1 thru 51-2 50-1 thru 50-2 Measured E/F 50G/51G Measurement RMS 51-G thru 51-4 51-G thru 51G-4 50G1- thru 50G-4 Control & Logic Autorecloser Prot’n Autorecloser Config Manual Close Circuit Breaker Quicklogic Input Config Input Matrix Binary Input Config General Alarms Output Config Output Matrix Binary Output Config LED Config Pickup Config Trip Config CB Maintenance CB Counters Output Matrix Data Storage Communications 01: 1/4/2012 Type 7SR11/7SR12 Relay Name: Quick Reference Guide For Single-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 02-12 Scale: NONE Sheet: 3 of 4 Part No: 18-671-296-407 Issue/Rev: 01 This page left intentionally blank. 01: 1/4/2012 Type 7SR11/7SR12 Relay Name: Quick Reference Guide For Single-Phase SDR Recloser TGH 02/12 DR: _______ TGH 02/12 CH: _______ ---AP: _______ Similar To: Bulletin: 02-12 Scale: NONE Sheet: 4 of 4 Part No: 18-671-296-407 Issue/Rev: 01
© Copyright 2026 Paperzz