pv3aluminum electrolytic capacitors with conductive polymer solid

NEW
PV3
PV3
ALUMINUM
ELECTROLYTIC
CAPACITORS
ALUMINUM
ELECTROLYTIC
CAPACITORS
WITH
CONDUCTIVE
POLYMER
SOLID
ELECTROLYTE
WITH
CONDUCTIVE
POLYMER
SOLID
ELECTROLYTE
GREEN
CAP
Chip Type
●
●
●
SMD
Low
ESR
105˚C
1000hours
®
®
Anticleaning
solvent
4.0mm height
Super low E.S.R. and high ripple current are realized.
Guaranteed 105℃, 1000 hours.
Low Profile
PV3
PV2
Marking color : Blue print
Specifications
Performance
ー55 to +105
±20
Item
Tolerance at rated capacitance (%)
Leakage current (µA)
*Note
(20℃,120Hz)
Less than 700µA
(20℃)
(20℃,120Hz)
Less than 0.12
Tangent of the loss angle (tanδ)
Impedance ratio (max.)
Characteristics at high
and low temperature
Zー25℃/Z+20℃
Zー55℃/Z+20℃
1.15
1.25
(100kHz)
Endurance (105℃)
(Applied ripple current)
Test time
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
1000 hours
The initial specified value or less
Within ±20% of initial value
150% or less of the initial specified value
150% or less of the initial specified value
Bias Humidity
60℃, 90 to 95%RH
Test time
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
500 hours
The initial specified value or less
Within ±20% of initial value
150% or less of the initial specified value
150% or less of the initial specified value
The capacitors shall be subject to 1000 cycles each consisting of charge with the surge voltage specified at 105℃ for 30 seconds
through a protective resister (Rc=1kΩ) in 6 minutes per cycle. Surge voltage : 1.15 times of rated voltage
The initial specified value or less
Within ±20% of initial value
150% or less of the initial specified value
150% or less of the initial specified value
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
Characteristics of applied
surge voltage
Failure tare
0.5% per 1000 hours maximum (Confidence level 60% at 105℃)
*Note : If any doubt arises, measure the leakage current after following voltage application treatment.
Voltage application treatment : DC rated voltage are applied to the capacitors for 120 minutes at 105℃.
Outline Drawing
Unit : mm
Part numbering system (example : 2.5V220µF)
PV3
(C)
A±0.2
0.4±0.2
0.3MAX
Series code
̶ 2R5
Rated voltage
symbol
V
221
M
Rated capacitance
Capacitance
symbol
tolerance symbol
E41
Casing
symbol
̶
Taping
symbol
(C)
(P)
B±0.2
φD±0.5
POLYMER
HYBRID
Category temperature range (℃)
L+0.1
−0.2
W
( ) : Reference size
φD
5
●
●
●
L
4
A
5.3
B
5.3
C
2.3
W
0.5 to 0.8
P
1.5
Casing symbol
E41
Soldering conditions are described on page 13.
Land pattern size are described on page 11.
The taping specifications are described on page 14.
CAT.No.2015/2016E
34
NOTE : ‌Design, Specifications are subject to change without notice.
It is recommended that you shall obtain technical specifications
from ELNA to ensure that the component is suitable for your use.
Standard Ratings
Rated voltage (V)
Item
Rated
capacitance (µF)
2.5
PV3
NEW
ALUMINUM ELECTROLYTIC CAPACITORS
WITH CONDUCTIVE POLYMER SOLID ELECTROLYTE
®
6.3
Case
ESR
Rated ripple
current
Case
ESR
Rated ripple
current
φD×L (mm)
(mΩ max.)
(mArms)
φD×L (mm)
(mΩ max.)
(mArms)
150
—
—
—
5×4.0
25
2700
220
5×4.0
25
3300
—
—
—
(Note) Rated ripple current : 105℃ , 100Hz ; ESR. : 20℃ , 100Hz
POLYMER
HYBRID
NOTE : Design,
‌
Specifications are subject to change without notice.
It is recommended that you shall obtain technical specifications
from ELNA to ensure that the component is suitable for your use.
35
CAT.No.2015/2016E