BOARD OF WATER COMMISSIONERS DENVER,COLORADO ADDENDUM NO.1 TO THE CONTRACT DOCUMENTS 555 OUIVAS REMODEL CONTRACT 12243A June 23, 2009 TO ALL PLAN-HOLDERS: This Addendum No. 1 consists of Page ADl-4. The following changes, additions, and/or deletions are hereby made part of the Contract Documents for 555 Quivas Remodel, Contract 12243A, dated June 2009, as fully and completely as if the same were fully set forth therein: SPECIFICATIONS: 1. SECTION 08 14 16 - FLUSH WOOD DOORS, PART 2, SUBPARAGRAPH 2.2.A.6. PAGE 3: ADD: 2. 6. All solid core wood doors shall be 1 3/4" thick. SECTION 08 71 00 PAGE 7: ADD: DOOR HARDWARE, PART 3. SUBPARAGRAPH 3.6.A, SET #102A 3 Hinges 1 Exit Device 1 RIM Cylinder 1 Door Closer 1 Kick Plate 1 Wall Bumper 3 Door Silencers 3. FBB179 4 1/2 x 4 1/2 2103 x 4903A TRIM lEn D-4551 STD SN K0050 10" x 2" LDW B4E C-Sunk-KP 1270WV 1229A S26D US32D US26D AL ST BE BE ST 630 630 TR TR TR SECTION 09 30 00 - TILING. PART 3, SUBPARAGRAPH 3.3.J, PAGE 9: ADD: J. Accent band within the ceramic tile walls in the restrooms shall be comprised of all four accent colors in approximately equal quantities pattern shall be random. Ceramic tile base will be the same color/pattern as the wall field tile 6 inches high x 12 inches long with integral cove. (BOARD OF WATER COMMISSIONERS (555 QUIVAS REMODEL (12243A AD1-l 4. SECTION 10 1400 - SIGNAGE. PART 3. SUBPARAGRAPH 3.1.C. PAGE 2: ADD: c. The following signs will be required: Room Number On Plan 01 02 03 05 06 09 10 11 12 14 15 18 19 (2 SIGNS) 22 24 25 5. Sign Text To be Determined CONFERENCE 2 VALVE ROOM CONFERENCE 1 CLOSET ELECTRICAL ROOM I.T. SUPPORT JANITOR CONFERENCE 3 WOMEN MEN GARAGE MECHANICAL CONFERENCE COMPUTER STORAGE 1. Room numbers used on signage shall be 3 digits to be determined. All Signage to be ADA compliant. 2. All room signs to be mounted on the wall adjacent to the latch side of the door 48"' above finished floor to tactile characters, maximum. 3. Sign text may vary subject to review by the ENGINEER. Colors shall be selected from Manufacturer's standard colors by Engineer SECTION 23 09 23 - DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC. PART 1. SUBPARAGRAPH 1.1.F. PAGE 1: DELETE: 6. Room Name On Plan OFFICE CONFERENCE SPRINKLER ..... CONFERENCE CLOSET ELECTRICAL IT SUPPORT JANITOR CONFERENCE WOMEN MEN PARKING MECHANICAL CONFERENCE COMPUTER LAB SECURE STORAGE Paragraph in its entirety. SECTION 23 09 23 - DIRECT DIGITAL CONTROL SYSTEM FOR HVAC, PART 1, SUBPARAGRAPH 1.1.J. PAGE 2: ADD: J. Controls Contractor is to prOVide all HVAC controls for this project. except for: 1. 2. 3. (BOARD OF WATER COMMISSIONERS (555 QUIVAS REMODEL (12243A Internal refrigeration controls for the air cooled condensing unit. Burner modulation controls for the air handler heating section. Microprocessor based controls for the CRAC unit, (the BAS will interface with the CRAC unit control system for the purposes of alarm monitoring and space temperature setpoint control). ADl-2 7. SECTION 23 73 00 - INDOOR CENTRAL-STATION AIR-HANDLING UNITS. PART 2, SUBPARAGRAPH 2.10.A., PAGE 6: DELETE: 8. SECTION 2605 19 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES, PART 1, SUBPARAGRAPH 1.3.B.7, PAGE 2: ADD: 9. All conductors sized #6AWG and larger shall be type XHHW-2; all conductors sized less than #6AWG shall be type THHN/THWN. SECTION 26 05 53 - IDENTIFICATION FOR ELECTRICAL SYSTEMS, PART 2, SUBPARAGRAPH 2.2.C, PAGE 2: ADD: 10. Paragraph in its entirety. All wire markers shall be machine printed. SECTION 28 31 00 - COMMON WORK RESULTS FOR FIRE SUPPRESSION, PART 1, SUBPARAGRAPH 1.6.D, PAGE 2: ADD: Provide all fire alarm system passwords, access codes and copy of final fire alarm control panel programming to the OWNER. DRAWINGS: 1. 2. 3. 4. 5. 6. DRAWING ALl - SITE PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised d rawi ng. DRAWING A2.1 - DEMOLITION PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING A2.2 - FLOOR CONSTRUCTION PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised draWing. DRAWING A2.5 - WING PLAN, DEMOLITION AND RCP: DELETE: Drawing in its entirety. SUBSTITUTE: Revised draWing. DRAWING A4.2 - INTERIOR ELEVATIONS: DELETE: Drawing in its entirety. SUBSTITUTE: Revised draWing. DRAWING A6,1 - DOOR SCHEDULES AND DETAILS: DELETE: Drawing in its entirety. (BOARD OF WATER COMMISSIONERS (555 QUIVAS REMODEL (12243A ADl-3 SUBSTITUTE: 7. 8. 9. 10. 11. 12. 13. Revised drawing. DRAWING A6.2 - WINDOW SCHEDULES AND DETAILS: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING M3.1 - MECHANICAL PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING Ml0.l - MECHANICAL DETAILS: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING P1.1 - PLUMBING DEMOLITION PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING E4.1 - POWER PLAN: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING EllA - ELECTRICAL SCHEDULES: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. DRAWING FA11.1 - FIRE ALARM SYSTEM SEOUENCE OF OPERATIONS: DELETE: Drawing in its entirety. SUBSTITUTE: Revised drawing. All Bidders shall acknowledge receipt and acceptance of this Addendum No. 1 in the space provided on the Bid Form. c.ers:PE Engineering Manager Denver Board of Water Commissioners (BOARD OF WATER COMMISSIONERS (555 QUIVAS REMODEL (12243A ADl-4
© Copyright 2025 Paperzz