STEEL
PLASTIC CANNULA
Reactions to plastic cannula / History
of bent cannula / Pregnant (up to
2nd trimester) / Small child
Less active / Alternative site
usage / Poor dexterity
Less active / Alternative site usage
Active / Lean / Muscular /
Pregnant (from 2nd trimester)
90 degree insertion
90 degree insertion
90 degree insertion
30-45 degree insertion
Sure-T ® infusion set
Quick-set® infusion set
mio® infusion set
Silhouette® infusion set
Simple steel needle infusion set
Our most popular infusion set
Convenient “all in one” infusion set
Flexible insertion angle infusion set
Low/Average BMI
Average/High BMI
6mm
8mm
Wear insulin pump close
to infusion site
Wear insulin pump
close to infusion site
18” or
23”
23”
10mm
32”
Low/Average BMI
Average/High BMI
Low/Average BMI
Average/High BMI
Low/Average BMI
Average/High BMI
6mm
9mm
6mm
9mm
13mm
17mm
Wear insulin pump close
to infusion site
Wear insulin pump close
to infusion site
Wear insulin pump close
to infusion site
Wear insulin pump close
to infusion site
Wear insulin pump close
to infusion site
18” or 23”
23”
18” or 23”
18” or 23”
23”
32”
Wear insulin pump away
from infusion site
Wear insulin pump
away from infusion site
Wear insulin pump away
from infusion site
Wear insulin pump away
from infusion site
Wear insulin pump away
from infusion site
Wear insulin pump away
from infusion site
Wear insulin pump away
from infusion site
32”
32”
32” or 43”
32” or 43”
32”
32” or 43”
32” or 43”
Recommendation based on Insulin Pump Therapy: Best practices in choosing and using infusion devices. American Association of Diabetes Educators, 2011. Data on file.
-
BMI stands for Body Mass Index which is calculated based on an individual’s weight and height.
Safety Information
Infusion sets are indicated for the subcutaneous infusion of medication, including insulin, from infusion pumps. They are neither intended nor indicated for intravenous (IV) infusion or the infusion of blood or blood products. Inaccurate medication, delivery, infection and/or site irritation may result from improper insertion and maintenance
of the infusion insertion and maintenance of the infusion site. Replace the infusion set every 48-72 hours , or per your healthcare professional’s instructions.
Mio, Quick-set, Silhouette, and Sure-T are registered trademarks of Medtronic MiniMed, Inc.
940M10292-011 20120727 © 2012 Medtronic MiniMed, Inc. All rights reserved.