Digital pressure indicator Type HM 5 HM 5 – 3X/

RE 29 975/10.99
RE 29 975/10.99
Replaces: 05.99
Digital pressure indicator
Type HM 5
F 90 031
Series 3X
Type HM 5
Table of contents
Contents
Features
Ordering code
Technical data
Terminal connection
Unit dimensions
Features
Page
1
1
2
2
2
– Suitable to indicate and control static and dynamic pressures
(in conjunction with pressure transducer HM 14)
– Housing with front panel 96 x 48 mm
– Signal input 0 to 10 V
– Analyzing electronics with analogue output 0 to 10 V
– 3-digit LED display
– Voltage supply 115 VAC or 230 VAC
Suitable pressure transducer:
– Type HM 14 (see RE 29 932)
Ordering code
HM 5 – 3X/
*
Further details in clear text
Pressure indicator with signal input 0 to 10 V
Series 30 to 39
(30 to 39: externally interchangeable)
= 3X
115 =
230 =
Pressure ranges:
up to 10 bar
up to 50 bar
up to 100 bar
up to 200 bar
up to 315 bar
up to 450 bar
up to 600 bar
HM 5
=
=
=
=
=
=
=
1/2
10
50
100
200
315
450
600
Voltage supply:
Operating voltage 115 VAC
Operating voltage 230 VAC
RE 29 975/10.99
Technical Data (For applications outside these parameters, please consult us!)
Operating voltage
UB
115 VAC or 230 VAC; each ± 10 %; 50 to 60 Hz
Power requirement
PS
approx. 8 VA
Fuse, internal
IS
315 mA
Input signal
UE
0 to 10 V (4-conductor)
Output voltage
UA
0 to 10 V; max. 5 mA
Voltage supply for pressure transducer
UA
± 12 V; max. 40 mA
Load resistance
R
≥ 2 kΩ
Pressure indicator
7 segment, 3-digit, 14 mm high, red
Measuring rate
max. 3 s –1
Assurancy
0,25 ± 1/2 digit
Permissible ambient temperature range
ϑ
0 to + 50 °C
Influence of temperature: – on the zero point
– on sensivity
tE
tE
0,2 ‰/°C
0,1 ‰/°C
Weight
m
approx. 0,5 kg
Terminal connection HM 5 with pressure transducer HM 14
Pressure indicator
+
A
+ 12 V
1
B
Signal 0 … 10 V
2
C
0V
5
–12 V
3
Pressure transducer
HM 14
bar
–
D
HM 5
4
We recommend a 4-core connection
cable type LiYCY (0,5 mm2).
0
UA
Output voltage
UA = 0 to 10 V; max. 5 mA
Unit dimensions
1
(dimensions in mm)
2
112
3
96
14
48
42,5
13
bar
HM 5
5
104
Front panel cut-out 91 x 45 mm
10
1
2
3
4
150
4
Mannesmann Rexroth AG
Rexroth Hydraulics
Mannesmann Rexroth Limited
D-97813 Lohr am Main
Jahnstraße 3-5 • D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 • Telex 6 89 418-0
eMail [email protected]
Internet www.rexroth.com
Cromwell Road, St Neots,
Cambs, PE19 2ES
Tel:
0 14 80 / 22 32 56
Fax: 0 14 80 / 21 90 52
E-mail: [email protected]
All rights reserved – Subject to revision
2/2
maximum front panel thickness
connection frame
connect. cabel with Euro flat plug, length approx. 1,5 m
minimum installation length
The specified data is for product description
purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the
contract.
HM 5