DRAFT The NELAC Institute Presents: SUGGESTED PROCEDURES FOR LOQ TNI plays well with Others… These suggested procedures are compliant with NELAC and TNI standards, and can provide a dataset suitable for other Quantitation Limit protocols, including: Detection/Quantitation Federal Advisory Committee procedure Office of Water MRL Texas PQL DoD QSM v4.1 TNI DEFINITION - LOQ Limit of Quantitation The minimum levels, concentrations, or quantities of a target analyte that can be reported with a specified degree of confidence. What is a TNI LOQ? I see some yellow pollen on the stamens below. This magnification is at my Limit of Detection (LOD). If it were any smaller I wouldn’t see the pollen. Magnif Magnification – 2x How many pollen particles do I see? (quantitate?) I think maybe 3… TNI DEFINITION - LOQ I wasn’t really sure at 2x how many pollen particles there were. But at 5x I am sure I am reliably quantitating Magnification – 5x LOD is 2x (I can see it) LOQ is 5x (I can reliably quantitate) Exceptions for LOQ An annual LOQ verification is not required if the LOD was already determined or verified annually on that instrument. Requirements: All sample processing steps must be included in the determination of the LOQ Requirements: An LOQ verification study is not required for any component or property for which spiking solutions or quality control samples are not available or otherwise inappropriate. Such as pH or temperature. Requirements: The LOQ verification sample: a. Must be spiked at 1-2 times the claimed LOQ, b. And recovery must be within established control limits. Limits Result 50 – 150% 94% percent VERIFIED 120 110 100 90 80 LOQ Verification Spike LOD LOQ 2xLOQ concentration Requirements: The LOQ verification sample: a. Must be spiked at 1-2 times the claimed LOQ, b. And recovery must be within established control limits. percent Limits Whatever 89.375 50 +/–is-–107.6 3125% 150% SD % reasonable! Result 94% 120 110 100 90 80 LOD LOQ 2xLOQ concentration Requirements: When an LOD is determined or verified by the laboratory, the LOQ shall be above the LOD. Translation: They can not be the same number zero LOD LOQ If you don’t require an LOD, then you don’t have to check that your LOQ is greater than your LOD! Requirements: What? Verify LOQ annually …In each quality system matrix AND for each technology… ON EACH INSTRUMENT?? Requirements: Document your procedures for LOQ determination and verification for each quality My Quality Manual or SOP system matrix type. How my LOQ is determined in: a. Water b. Sediment c. Tissue Please be sure to check the appropriate TNI module for analysisspecific LOD or LOQ requirements Recommendation: Because your lowest calibration standard will be your LOQ concentration or lower, pick an LOQ that will pass calibration criteria. LOQ Recommendation: If you have an LOD that is about as low as you can go, then pick an LOQ that is at least 2 x your LOD LOD LOQ Q: A: Can your LOQ be anything you want? As long as it is greater than your LOD. And it meets all client or program requirements… Recommendation: If you want to comply with other programs that require multiple spikes for verification, we recommend you first test with just one spike. If the LOQ was too low, you didn’t waste time or money preparing the rest. Recommendation: To be compliant with other programs by analyzing multiple LOQ spikes, we recommend… Analyzing at least 2 replicates on each instrument for a total of at least 7 replicates. Replicates should not all be analyzed in a single batch – a more representative data set is obtained if the samples are spread over time. Thought: If you make an LOQ spike part of your routine quality assurance, you won’t have to bother doing a separate study at the end of the year. REVIEW: Your TNI LOQ wish-list …something that Something meetsabout program twice the LOD would …ohhhh. And don’t forget and customer different matrices or technologies. berequirements…. nice…. If this LOQ …something won’t pass forthat them can be (even thoughverified it’s the on same each …maybe something that analyte), I may require a separate instrument… would pass LOQ forcalibration those. criteria and… end
© Copyright 2026 Paperzz