Conductivity and temperature simulator, SI 85 At last! A replacement for the classic decades of resistance! The SI 85 switches an array of highprecision resistances electronically. It simulates 6 values of conductivity using resistances. Similarly, it also simulates 6 different temperature values, which facilitates verification of the temperature scale of conductivity meters. The SI 85 is an instrument for verifying and self-calibrating lab conductivity meters and is the ideal tool for checking complete installations for conductivity control in industry. Key features The simulated values cover the whole normal scale, from 1 µS, to 100 mS. The real value of the simulated conductivity or temperature can be viewed on-screen. Highly stable simulated values. Long life membrane keypad, for industrial use. IP 65 protection. The instrument can simulate: - 6 different values of conductivity - 6 values as a Pt 100 sensor - 6 values as a Pt 1000. Signal output comes from an MP-5 connector. The on-screen conductivity values are simulated in two different ways: - ”Uni” objective values, measured with a standard multimeter. - ”GLP”, adapted values, compensating for the length of the cell cable for calibrating GLP CRISON conductivity meters. 75 The instrument automatically switches itself off if no keys are pressed for 5 minutes. This function can be disabled by the user. Uses very little electricity. With the instrument on, the batteries will last approximately 180 hours. Low battery level indicated. Practical case, optional, to keep the instrument safe and carry it around. Certificates The SI 85 is supplied with the specifications Certificate and the EC Declaration of Conformity as per directive EMC 89/336/EC. With code 85 02 the instrument is supplied with an ISO Calibration Certificate, issued by the CRISON calibration lab. For further information, please see page 132. Re-calibration There is very little drift over time in the SI 85, thanks to its high-quality components. However, to ensure that the simulated values are exact, CRISON recommends annual calibration. Laboratory Catalogue 2004 1st Edition � 76 SI 85 (continued) Display examples Keypad The user can access all the instruments functions using only 4 keys. Simulation χ Simulated value Universal GLP CRISON Cell constant = 1 Technical specifications Temperature simulation (Pt 1000) Simulated sensor, Pt 1000 � Operation The SI 85 software is similar to that of all other CRISON portables, and has been designed to make using this new range of instruments as easy as possible. Simulated temperature Temperature simulation (Pt 100) Simulated sensor, Pt 100 Simulated temperature Cables for adapting the SI 85 to various conductivity meters. Simulated values* Conductivity Temperature, Pt 100 Temperature, Pt 1000 1.0, 10.0, 100.0, 1000 µS and 10.00, 100.0 mS (at 25ºC) -23.0, 0.0, 25.0, 50.0, 100.0 and 200 ºC -23.0, 0.0, 25.0, 50.0, 100.0 and 200 ºC Resolution Conductivity Temperature Depending on the simulated value 0.1 ºC Error (± 1 digit) Conductivity Temperature ≤ 0.2%, range 100 mS ≤ 1% ≤ 0.1 ºC Reproducibility (± 1 digit) Conductivity Temperature ≤ 0.1%, range 100 mS ≤ 0.3% ≤ 0.1 ºC Thermal drift Conductivity Temperature ≤ 15 ppm, range 100 mS ≤150 ppm ≤ 15 ppm Connector MP 5, five-contact multipin IP 67 Protection Automatic switch off After 5 minutes, with option to disable this function Display Liquid crystal with pictograms Keypad Membrane, 4 keys. Guaranteed for up to 6 million strokes per key. Material: PET with protective treatment Power supply Two 1.5V, type AA batteries, autonomy > 180 h. Electrical safety EN 61010-1 EMC (Electromagnetic compatibility) Meets EC, EN 61326 Degree of protection IP 65 Permitted ambient conditions Operating temperature 10...40ºC Storage and transport temperature –15... 65ºC < 80 % relative humidity, non-condensing Enclosure Casing material: ABS Physical parameters Weight 190 g, Dimensions 160 x 74 x 50 mm (*) The simulated values are close to the above mentioned values. The real simulated values appear on the instrument display. Specifications suject to change without notice Ordering information 94 30 94 31 / 94 40 94 32 Code Description 85 00 Simulator SI 85 85 01 Simulator SI 85, with carry case 85 02 Simulator SI 85, with carry case and certificate of calibration 94 30 Cable from SI 85 to BASIC 30, GLP 31 and 32 conductivity meters. 94 31 Cable from SI 85 to CM 35 94 32 Cable from SI 85 to terminal strip connection of CM 38, CM 39, etc. 94 40 Cable from SI 85 to PH 25 and TM 65 Laboratory Catalogue 2004 1st Edition
© Copyright 2026 Paperzz