F L O W C O N T R O L RSR SERIES SPRING RETURN ELECTRIC ACTUATORS UP TO 540" LBS KEY FEATURES AND BENEFITS •Mechanical Spring Open or Closed Operation •Manual Override Standard •NEMA 4X/IP66 Rated •Pre-Wired 1M Cable •1/2" Conduit Connection •Compact Size OPTIONS •Internal Dual Mechanical Auxiliary Switches •Proportional Control •Manual Handwheel Override •External Auxiliary Switch Pack TECHNICAL INFORMATION DIMENSIONS Spring CW Side 80mm 3.15" Spring CCW Side 210mm 8.28" 1m 39" 119mm 4.69" 30mm 1.18" 30mm 1.18" 14mm 0.55" 95mm 3.74" spring wind 74mm 2.92" Spring CW Side Ø6.6 THRU (6) HOLES TOTAL DOUBLE SQUARED 12 x 12 mm M4 THREAD (Existing) (6) HOLES TOTAL Y YEAR NT 2 AR D WA R R A QU TY ASSU D H AY W LI RSR4~6 Series RE A RSR3 Series Flow Control: Valves | Actuation & Controls | Strainers | Filters | Instrumentation | Pumps | Bulkhead Fittings & Tank Accessories S PR I N G R ET UR N ELEC TR IC AC TUATION NEW PRODUCT PREVIEW RSR Series Spring Return Electric Actuators UP TO 540" LBS TECHNICAL INFORMATION (Continued) ACTUATOR SPECIFICATIONS Torque (Motor) Minimum Torque (Spring) Minimum Minimum Required Torque Current Draw Runtime (Power)*** Runtime (Spring)*** Drive Configuration Physical Dimensions Weight RSR3-0 RSR3-2 RSR3-P RSR4-0 133"lb/15Nm 133"lb/15Nm 27"lb/3Nm 4.7A @ 3 sec Mode MAX 30 Seconds @ 90 deg 10 Seconds @ 90 deg 12mm Double Square, 100% Overload-Proof Self-Locking up to 133"lbs/15Nm 8.3"L x 3.7"W x 3.2"D / 210mm x 95mm x 80mm 7.8 lbs / 3.5Kg (No Options Installed) ACTUATOR SPECIFICATIONS RSR4-2 270"lb/30Nm 270"lb/30Nm RSR4-P RSR5-0 RSR5-2 RSR5-P RSR6-0 450"lb/50Nm 450"lb/50Nm 90"lb/10Nm 1.5A @ 24V ~ 0.13A @ 240v 90 Seconds @ 90 deg 20 Seconds @ 90 deg 16m Double Square, 100% Overload-Proof Self-Locking up to rated torque 13.7"L x 5.9"W x 4.6"D / 348mm x 149mm x 116mm 21 lbs / 9.5Kg (No Options Installed) 540"lb/60Nm 540"lb/15Nm RSR3, 4, 5, 6-0 RSR3, 4, 5, 6-2 RSR3, 4, 5-P* On/Off/Jog None 24 ~ 230vac/dc, +15% / -20% AC:50/60Hz Class 1 (grounded) 95 deg including 5 deg pre-load Brushless DC Minimum 10,000 Cycles @ 10 sec Spring (20 sec Spring RSR4~6) Up to 1 second after power failure On/Off/Jog None 4-20mA or 2-10vdc IN 4-20mA or 2-10vdc OUT 0.1A @ 250vac / 3A @ 24vac None Supply Voltage/Frequency Wiring Class Angle of Rotation Motor Type Life Cycles – Spring Response Time (Spring) Control Mode Feedback Auxiliary Switch Rating (2) - fixed @ 5° and 85° Electrical Connections Environmental Rating Manual Override Integral Heater Housing Material None RSR6-2 1m Cable, Exits through 1/2" EMT Connector NEMA 4X / IP66 ** Supplied Hex Key (Opt Handwheel) Thermostatically controlled Aluminum die cast, Epoxy painted Storage Temp: -40F/+158F (-40C/+70C) Working Temp: -40F/+122F (-40C/+50C) Ambient Operating Range Duty Cycle (>14 sec Mode) Maintenance * RSR6 is NOT available in proportional control model ** Rain / Snow / Ice / Sun shield is recommended for outdoor installations *** Power and Spring runtime can be factory reconfigured upon request 50% Maintenance Free WIRING DIAGRAMS 4 Loss of Main Power “c” causes spring return, regardless of “a” or “b” condition. If mounted CCW side UP: Optional ... close “a” = drive CW ... close “b” = drive CCW Internal aux. switches are dry contact Form A type. Max 24v/3A, 230v/0.25A. Switch points are FIXED at 5° and 85° rotation. Either CW or CCW side up does not affect the switch points. If mounted CW side UP: ... close “a” = drive CCW ... close “b” = drive CW (To Override Mod Signal) If mounted CCW side UP: ~ + ~ C ... close “a” = drive CCW ... close “b” = drive CW 24 to 240 VAC/DC 24 to 240 VAC/DC GND If mounted CW side UP: ... close “a” = drive CW ... close “b” = drive CCW > 85° < 5° A GND ~ + ~ YmA Y VDC 2 3 heater Hayward is a registered trademark of Hayward Industries, Inc. © 2017 Hayward Industries, Inc. UmA UVDC B C 1 VDC/mA 4 5 6 7 I 8 1 2 3 4 heater Contact Hayward Flow Control with questions: USA: 1.888.429.4635 • Fax: 1.888.778.8410 • One Hayward Industrial Drive • Clemmons, NC 27012 • Email: [email protected] Canada: 1.888.238.7665 • Fax: 1.905.829.3636 • 2880 Plymouth Drive • Oakville, ON L6H 5R4 • Email: [email protected] Visit us at: haywardflowcontrol.com NPP0417
© Copyright 2026 Paperzz