The Art of MultiWave TM Ultrasound Imaging for the Thyroid Aixplorer® with MultiWave™ Technology offers you impeccable thyroid images that are clinically informative MultiWave Technology multiplies your confidence and brings you two waves to better characterize tissue One ultrasound wave ensures impeccable image quality Using SonicSoftware™ the Aixplorer rapidly and flexibly delivers clinical images of a quality never seen before. Technological advances such as SuperCompound™, SuperRes™ and TissueTuner™ ensure superb image resolution and delineation. One ShearWaveTM measures and displays, in real-time, local tissue elasticity in kilopascals With MultiWave technology, Aixplorer relies on the simultaneous use of both ultrasound waves and shear waves to better characterize and quantify tissue stiffness. Shear wave velocity is directly related to the quantifiable measurement of tissue elasticity. Aixplorer can generate, capture and quantify the velocity of a shear wave by acquiring data up to 200 times faster than conventional ultrasound technology. Aixplorer produces in real-time, a quantitative color coded map displaying local tissue elasticity for a large image region. An easy-to-read color scale indicates tissue elasticity. 2 Thyroid ShearWave Elastography image indicating local tissue elasticity: very soft (blue) and very hard (red) MultiWave™ Technology Enables ShearWave™ Elastography Aixplorer meets your quantitative needs with a non-invasive procedure that can: • Generate a shear wave using SonicTouch TM, no manual compression is required • Capture a shear wave with UltraFast TM Imaging - UltraFast acquisition minimizes artifacts due to respiratory or cardiac interference giving a dependable consistent image • Quantify shear wave speed resulting in true tissue elasticity values in kilopascals Capture: UltraFast Imaging Generate: SonicTouch Quantify: ShearWave Elastography +180 KPa 144 t=2ms t=10ms 72 36 t=20ms Shear wave propagation is captured with plane waves using UltraFast Imaging at acquisition speeds of up to 20,000 Hz Shear wave propagation speed relates directly to the local elasticity of tissue and can be measured in kilopascals fication in uanti kilo q e pa m i d n e i l p l t i s e k nde l-s r e nt Us b i l c e u r esu rod p l e ls ca ts R Re a Pulses are successively focused at different depths in tissue at supersonic speed ShearWave SWE Elastography 3 Dedicated solutions for your thyroid imaging challenges Aixplorer’s Thyroid Package offers you exceptional features to optimize your imaging needs Trapezoidal Imaging • Extended field of view to capture the whole thyroid gland. • Expanded measurement capabilities extending outside the image area yielding an estimated thyroid gland size. Trapezoidal Healthy Thyroid Image Dual Imaging Both lobes of the thyroid can be imaged separately in B-Mode and merged to display the entire thyroid gland into one image. Thyroid Right Lobe 4 Thyroid Left Lobe Dual Mode: Full Thyroid Image Annotations and Body Marker Libraries Pioneering Thy-RADS TM Documentation Tool Select the required annotation(s), body marker(s) and transducer orientation for thyroid anatomy imaging directly from the touch screen. This unique feature provides a standardized descriptive checklist, similar to the BI-RADS® (American College of Radiology: Breast Imaging – Reporting and Data System) which enables quick identification and documentation for nodule characterization in thyroid pathology. Thy-RADS can be simultaneously applied on up to 8 thyroid nodules at a time. Descriptors can then be included in your final report. Transducer orientation body marker Aixplorer is at the forefront of ergonomics and provides the optimal workflow for your clinical team. Thy-RADS Clinical Descriptors 5 Impeccable Images Aixplorer® multiplies your confidence in thyroid disease diagnosis SuperRes™ Color Doppler Improves conspicuity with four levels of adjustment to reduce speckle and enhance delineation. Includes Color Power and Color Flow. Ultra sensitive flow without motion artifacts renders enhanced vascularization without compromising B-Mode image quality. In addition Simultaneous Mode gives you the ability to view both live B-Mode and Pulsed Wave Doppler simultaneously. SuperCompound TM Offers excellent B-Mode image quality with spatial compounding even while Color Flow or ShearWave Elastography is in use. SuperRes adaptive filter and SuperCompound on thyroid Color Doppler: Circumferential vascularity in color flow mode Complex nodule displaying excellent tissue differentiation and spatial resolution due to TissueTuner and SuperRes Color Doppler: Intranodular vascularity in color power mode TissueTuner™ Grants optimal resolution with five settings that adjust the system’s parameters to accurately match the speed of sound in various tissue being scanned. 6 ShearWave TM Elastography Q-Box™ Quantification Tool – Accurately measures, in real-time, true tissue elasticity in kilopascals. Multiple areas of interest can be compared and quantified simultaneously. Q-Box™ E Ratio Tool – Compares stiffness of two regions as a ratio; nodule to parenchyma. As ShearWave Elastography is truly quantitative, nodules that are difficult to characterize can be followed over time. Q-Box Quantification Tool. Stiffness of nodule (28 kPa) is softer than parenchyma (52.2 Kpa). Cartilage appears as very hard on ShearWave Elastography map Q-Box Ratio. Thyroid displaying papillary cancer: stiffness of nodule is 201.9 kPa 7x harder than normal parenchyma ShearWave Elastography enables real-time quantitative tissue characterization and differentiation between cystic and solid thyroid nodules. 7 Sophisticated Features for Intuitive Use Fully adjustable wide format 20 inch flat panel monitor Standard features • • • • • • • • • • • • • • • • • • • • • • • Flat 20 inch LCD Monitor B-Mode Imaging Pulse Wave Doppler Simultaneous Mode (B-Mode and PW Doppler) Color Doppler Power Doppler SuperCompound™ SuperRes™ TissueTuner™ Tissue Harmonic Imaging Auto TGC/ManualTouch™ TGC Dual Image Display Trapezoid Imaging in B-Mode HD Zoom Digital Zooming Touch screen measuring capability Real-Time ShearWave™ Elastography Mode Q-Box™ Quantification Lesion Measurement Tool Box CineReview – up to 768 images can be stored Clip Save and Play Back Three different imaging sector widths available Image Management capabilities: thumbnail image review, patient reporting • Cable Management Connectivity • Export/Import managed by CD/DVD or USB mass storage • USB external port • SAMBA communication protocol • DICOM Convenient trackball and TouchRingTM Stereo audio speakers Total arm articulation Interactive touch screen also used for measurements Accessible gel holder Control panel with fully adjustable height and rotation abilities Ultra lightweight transducer Comfortable palm rest Magnetic stylus holder Transducer holder Cable management Easy to maneuver handles Four way swivel wheels with manual brakes SonicResearchTM Package • Open per channel RF data access Footrest 8 Frontwheelsequipped with directional lock The Aixplorer provides you with both excellent B-Mode resolution and penetration while also offering imaging capabilities critical to your thyroid diagnostic process. User Friendly Advanced Tools and Clinical Guides • Quick and accurate measurement package • Automatic report labelling • On-screen digital markers that remain aligned with your clinical area of interest The SuperLinearTM SL15-4 Broadband Transducer The SuperLinear SL 15-4 transducer is designed to help you acquire the most accurate data possible for every exam. The lightweight transducer has been ergonomically studied and validated by physicians and sonographers to fit perfectly in your hand in a relaxed position. • This unique transducer technology provides both outstanding B-Mode image quality and ShearWave Elastography performance. • The 50mm linear array transducer for the thyroid is equipped with an extended frequency range from 4-15 MHz. Four way swivel wheels with manual brakes SuperLinear Transducer 9 Remarkable Post Processing Options SonicSoftware is so advanced that it gives you the capability to save all original, real per channel data taken directly from the transducer and before beam-formation. This software advantage is unique to the Aixplorer and provides you with the following novel post-processing options in Frozen and Review format: Post-Processing TGC enables you to adjust or apply the manual TGC settings while in Frozen or Review Mode with the possibility to modify the Gain. In addition, you can re-save images, delivering flexibility in every imaging mode! In B-Mode . Gain . TGC . B-Mode Map . Dynamic Range . Persistence . SuperRes . Invert left/right . Digital Zoom . Hide Patient Data in accordance with HIPAA privacy regulations 10 Color Modes (CFI/CPI) . Invert Color . Blending . Hide Color (On/Off ) . Baseline . Color Map . Persistence . Color Priority SonicCare™ Customer Care Program SuperSonic Imagine offers you SonicCare a quality customer support program designed with your needs in mind. SonicCare gives you complete peace of mind for the protection and performance of your Aixplorer MultiWave Ultrasound System. Our team of highly trained clinical and technical specialists offer customized solutions, from installation to training to give you sustained maximum performance, higher productivity and increased efficiency. SuperSonic Imagine also offers a choice of clinical and technical education and online resources to meet your professional needs. For further information please contact your sales representative. SonicCare provides long term protection and ongoing enhanced performance for your ultrasound investment. 11 Patented Technology SuperSonic Imagine holds the exclusive rights to 25 patents and submissions and benefits from a close collaboration with the Physics and Industrial Chemistry School of Paris, Langevin Institute (Laboratoire Ondes et Acoustique) a prestigious school that sponsored the works of famous physicists: Curie, Langevin, Joliot-Curie, De Gennes, Charpak and Fink. Contact Details SuperSonic Imagine France SuperSonic Imagine Ltd. UK Les Jardins de la Duranne Bât. E & F 510, rue René Descartes 13857 Aix-en-Provence Cedex France +33 (0)4 88 19 68 55 +33 (0)4 42 52 59 21 * [email protected] 18, Upper Walk Virginia Water Surrey GU25 4SN UK +44 (0)845 643 4516 * [email protected] SuperSonic Imagine, Inc USA SuperSonic Imagine GmbH Germany 11714 North Creek Parkway N, Suite 150 Bothell, WA 98011 USA +1 (425) 686 6380 +1 (425) 686 6387 * [email protected] Dietlindenstr. 15 80802 München Germany +49 89 36036 844 +49 89 36036 700 * [email protected] www.supersonicimagine.com SuperSonic Imagine Asian Distribution Network Les Jardins de la Duranne Bât. E & F 510, rue René Descartes 13857 Aix-en-Provence, France +33 (0)4 88 19 68 55 +33 (0)4 42 52 59 21 * [email protected] SSID01750 / 100V1- TI2D100722B31
© Copyright 2026 Paperzz