Release Notes Release Notes for Cisco OnPlus Service r6.8 Last updated: 7 February, 2012 Contents 1 What’s New 1 Resolved Issues 1 Known Issues 2 What’s New Release 6.8 of the OnPlus Service addresses several known issues. Support has also been added for automated closure of ConnectWise service desk tickets associated with device monitor events after the device recovers. For example, if you have created a notification delivery rule that creates a service desk ticket when the device monitor detects that the monitored host is down, a notification is sent to ConnectWise, and a service desk ticket is created. If the device subsequently comes back up, the ConnectWise service ticket associated with that event is automatically marked Complete, and the Resolution field displays the device recovery event information. This feature applies to all device monitors except IP Change and WAN Network Performance. An Auto Select feature has been added to the Default View drop-down menu on the Dashboard. Auto Select will determine the view based on the number of devices discovered on the network (1 to 99 devices will display the Topology view, 100 or more devices will display the Device listing view). OnPlus Mobile App No updates to mobile application. Resolved Issues Table 1. Issues Resolved in Cisco OnPlus Service r6.8 Ref # CSCtw89811 Description Add Customer: Countries not sorted in drop-down list CSCtn94056 Cannot delete notification rule after the first one CSCtw76252 Contacts: "&" is displayed for "&" in tooltip for email address CSCto56874 Deactivated customer's device needs to stop contacting portal CSCtx17782 Delivery Rules: Issues observed in Edit drawer when using IE 7 or 8 CSCtw89990 Email address with “&” not populated correctly when clicking on it CSCtx06883 Export PNG button creates an image with topology errors CSCtw84917 Warning indicates deleting All Customers when actually deleting a rejected subagent © 2012 Cisco Systems, Inc. All rights reserved. Page 1 of 4 Release Notes Release Notes for Cisco OnPlus Service r6.8 Known Issues Table 2. Known Issues for Cisco OnPlus Service r6.8 Identifier Description CSCtq47355 Cannot trigger notifications for some Cisco Product support events (Field notices, S/W EoX) Symptoms: Notifications are not triggered and delivered for Cisco product support Field Notice and Software End-of Sale, -Support, -Life events. Workaround: None. CSCtr15833 PoE-connected ON100 Network Agent does not log source device’s events Symptoms: After restoring or upgrading firmware, a PoE power-source device (such as a switch or router) that is connected, LAN side, to an ON100 Network Agent does not list the “configuration starting” or “configuration completed” messages for that restore or upgrade process in the event logs. Workaround: None. CSCtr91637 Suspended agent is able to receive scheduled report notifications Symptoms: Scheduled report notifications are still delivered to suspended agents. Workaround: None CSCts16190 OnPlus GUI: Missing devices in topology lag several minutes behind monitors Symptoms: Devices that are powered off or go missing are slow to be displayed in the topology. Monitors will show an error occurred, but the difference in time is several minutes. Workaround: None. CSCts35706 Received error when adding a customer with PNG image (IE7 and IE8) Symptoms: When adding a customer using IE 7 or IE 8, if a PNG file was uploaded as the image, the following error is seen: Customer > createCustomer > Failed with message: Unable to create image (Problem importing image). Workaround: Use a .jpg-format image or use a different Web browser (Firefox, Safari). CSCts38607 OnPlus Mobile App (iOS): Errors for International (UTF-8) characters Symptoms: Input of UTF-8 characters gives “Internal Server Error”. Error occurs on the Add/Update Customer page, and the Create Report page. Workaround: Do not use international UTF-8 characters when entering data on the OnPlus portal. CSCtt05265 Safari 5.1, Flash 10.3.183.10 – No keyboard input Symptoms: When using Safari 5.1 browser and Adobe Flash 10.3.183.10 on the portal, if you select a customer and go to their dashboard, keyboard input is not accepted; you will not be able to enter access credentials or modify any device setting that require keyboard input. Workaround: None. Use a different Web browser, such as Internet Explorer or Firefox. CSCtt38708 Device Support: The device driver for the Cisco 2800 has no probe function Symptoms: For example, if you add a Cisco 2811 device to a customer network and connect the ON100 directly to a 2811 with a NM-ESW card and turn CDP off, the ON100 cannot discover the device properly. Workaround: None. CSCtu00522 Devices: Cisco 3750 does not show firmware success message. Symptoms: When performing a firmware upgrade via the OnPlus portal, the firmware upgrade successful message does not appear for 3750 switch (stacked configuration), even though the upgrade completes successfully. Workaround: None © 2012 Cisco Systems, Inc. All rights reserved. Page 2 of 4 Release Notes Release Notes for Cisco OnPlus Service r6.8 CSCtu24116 ntop disconnects current cross-launched connection without warning Symptoms: In the scenario where User A is connected to a device via a portal tunnel connection, when User B launches the ntop portal, User A will lose the connection to that device. There is no warning to User B about the disconnection. Workaround: None. CSCtu33471 Long user input with UTF-8 characters not displayed correctly Symptoms: User input that contains more than 25 UTF-8 characters does not display correctly on the portal. Workaround: None CSCtw47881 Need list to anchor on the current page after a delete Symptoms: On the Notifications > Delivery Rules and Agents > Approved Agents pages, after deleting an entry that is not on the first page, the user is taken to the first page instead of remaining on the current page. Workaround: None. CSCtw56748 Device Support: Discovery of NAS after restore displays wrong IP address and icon Symptoms: After restoring a backup of the NAS322, the NAS changes from DHCP IP (192.168.10.53) to a "192.168.1.50" The icon changes to the "TM" icon for one discovery cycle then changes back. Workaround: None. CSCtw75700 Reports: Misleading error statement when generating reports Symptoms: The message "Data Unavailable" can appear in OnPlus reports in cases where the cause of the error is that there is too much data. In this scenario, the report message is misleading and does not inform the user of the actual cause of the error. Workaround: None. CSCtw76098 Device Support: Cannot perform multi-firmware upgrade while PVC2300 has spinner on GUI Symptoms: When multiple devices are selected for firmware upgrade and one of the selected devices does not send a spinner stop message when the upgrade does not proceed, the user is not able to reselect the group of devices to try to upgrade firmware again. Workaround: None. CSCtw80622 Event History Report: Not all customer data is present in CSV format Symptoms: When creating a Event History report for All customers in CSV format, the following issues are observed in the generated report: The name of the customer is not in the report Data for only the first customer is included in the report Workaround: None. CSCtw84244 Device Support: Backup of device with no startup-configuration should generate error Symptoms: Generic iOS driver for the portal does not display an error message when configuration backup is attempted for a device without a startup-config file. Workaround: None. CSCtx03803 Device: Restoring configuration using latest firmware load of SG300 switch is not working Symptoms: After starting the restore of configuration on SG300 switch using firmware load 1.1.1.8 or 1.1.2.0 the user gets this message "Failed status code from LoadStatus:" and the restore doesn't complete. Workaround: None. CSCtx06111 Upgrading Cisco 1941 firmware renders 2 nodes with different MACs in portal Symptoms: After upgrading firmware on a Cisco 1941 device, a new MAC address is © 2012 Cisco Systems, Inc. All rights reserved. Page 3 of 4 Release Notes Release Notes for Cisco OnPlus Service r6.8 associated with the device on the same IP, causing two separate nodes to appear in the topology with same information. Workaround: None. CSCtx15629 Device Support Discovery fails to differentiate two devices of the same class with same IP address Symptoms: The discovery process fails to determine that two devices have the same IP address but different MAC addresses. Workaround: None CSCtx27699 Device Support : ASA 5500 driver name is misleading Symptoms: Using a device other than the ASA 5505 Security Appliance causes unfavorable results. Workaround: None. OnPlus Mobile Application CSCts33477 Cannot disable Push Notification for iPhone Symptoms: On the iPhone, the user cannot disable push notifications. Going to Settings>Notifications from the phone's home page does not show OnPlus Mobile. Workaround: None CSCtu05822 Android: Event added twice to Google Calendar Symptoms: When you press Add to Calendar, the event is always added, even if it is already listed, which can result in multiple duplicate entries for the same event. Workaround: None CSCtx17917 Android: Reports - Severities are out-of-order Symptoms: The report severities are out-of-order for Event History reports, making it difficult to determine which is the highest and which is the lowest severity. Workaround: None CSCtx20558 Android: Cannot 'Choose photo' for Samsung Galaxy S2 Symptoms: For the Samsung Galaxy S2, the user cannot choose a photo from the phone's local storage for uploading a Gallery photo. The user can browse to an image on the phone and select it for upload, but the image is never uploaded. Workaround: None CSCtw95486 When viewing the topology on an Android platform, the Topology is heavily compressed/pixilated Symptoms: The topology is heavily compressed on the Android screen. Workaround: None © 2012 Cisco Systems, Inc. All rights reserved. Page 4 of 4
© Copyright 2026 Paperzz