ARGO 12 3.3.2 SP3 US Common AID Update

Triton Systems of Delaware, LLC
ARGO 12 3.3.2 SP3 US
Common AID Update
Software Release Notes
Affected products
ARGO 12
August 2, 2016
Version 1.0
Triton Systems of Delaware, LLC
21405 B Street
Long Beach, MS 39560 USA
PHONE: (228) 868-1317
FAX: (228) 868-0437
ARGO 12 3.3.2 SP3 US Common AID Update Software Release Notes
Triton Systems
Page 1 of 5
August 2, 2016
INTRODUCTION......................................................................................................................... 3
PLATFORMS AFFECTED ......................................................................................................... 3
HARDWARE SUPPORT .................................................................................................................. 3
SOFTWARE REQUIREMENTS ......................................................................................................... 3
DESCRIPTION OF CHANGES ................................................................................................. 4
EMV KERNEL .............................................................................................................................. 4
CHANGES FROM 1.0.0 .................................................................................................................. 4
SUPPORT OF US APPLICATION IDS (AIDS) .................................................................................. 4
AUTOMATICALLY SELECT US EMV APPLICATIONS .................................................................... 4
MAGSTRIPE CARD READ BEHAVIOR ............................................................................................ 4
DESCRIPTION OF CHANGES (SERVICE PACK 3) ............................................................. 5
MTIP 01-06-01............................................................................................................................ 5
TRANSFER TRANSACTIONS .......................................................................................................... 5
PAN SEQUENCE # ........................................................................................................................ 5
DISCOVER UPDATE ...................................................................................................................... 5
VISA PLUS UPDATE ...................................................................................................................... 5
ADVT TEST CASE 8 .................................................................................................................... 5
MASTERCARD 9C TAG ................................................................................................................ 5
JCB/DNA AIDS .......................................................................................................................... 5
POS ENTRY MODE FLAG ............................................................................................................. 5
REVISION HISTORY ................................................................................................................. 5
ARGO 12 3.3.2 SP3 US Common AID Update Software Release Notes
Triton Systems
Page 2 of 5
August 2, 2016
Introduction
This document describes new functionality for the 3.3.2 Service Pack 3 US Common AID update
software release for ARGO 12 CE5 ATMs. The differences described are from version 3.3.2
SP1.
Platforms Affected
This release is for the following families:
 ARGO 12 CE5
Hardware Support
The following is a list of hardware supported by this software:
 Card Reader: Sankyo ICM330 Dip Reader
Software Requirements
The following load files are included with this release:
 xu34scsf3.3.2sp3.tfv – ARGO 12 CE5 Update
Must be loaded on top of any US 3.3.2 version. The program build after updating will be
3.3.2.28b.
.
ARGO 12 3.3.2 SP3 US Common AID Update Software Release Notes
Triton Systems
Page 3 of 5
August 2, 2016
Description of Changes
EMV Kernel
This software release contains a new version of the EMV kernel. The version listed in
Management > Terminal Configuration > More Options > EMV Configuration > Terminal
EMV Configuration will be 1.0.1.0. This kernel has been tested according to EMVCo Type
Approval Terminal Level 2 Test Cases document version 4.3d November, 2014.
Changes from 1.0.0
The following changes have been made from version 1.0.0:
- Support new test cases Interoper 29 02, 29 03 and MTIP 31 USM 01 01
- Application label incorrect when issuer code table index supported
- General memory leak fixes
Support of US Application IDs (AIDs)
This load file adds the following application ID to the available list of EMV applications:
- Visa US:
A0000000980840
- Maestro US: A0000000042203
- Discover:
A0000001523010
- Discover US: A0000001524010
- JCB US:
A000000065
- DNA US:
A000000620
All of these applications are enabled by default.
Automatically Select US EMV Applications
This update adds the capability for the ATM to automatically select US applications over other
applications with the same IIN on a chip card. The US AIDs are designated as priority
applications in this software update.
Magstripe Card Read Behavior
This software version changes the method in which magstripe cards are read with EMV enabled
at the ATM:
 If a magstripe only (non-chip) card is removed before the system finishes attempting to
read the chip, the ATM will continue to process the card as magstripe.
 If a chip card is removed before the system finishes attempting to read the chip, the ATM
will instruct the customer to re-insert the card and leave it in the reader until instructed.
ARGO 12 3.3.2 SP3 US Common AID Update Software Release Notes
Triton Systems
Page 4 of 5
August 2, 2016
Description of Changes (Service Pack 3)
MTIP 01-06-01
This software release contains an update to support test case MTIP 01-06-01 (version 15A).
Transfer Transactions
For transfer transactions with chip card, approve transaction based on host authorization (request
AAC from chip).
PAN Sequence #
For some cards, the PAN Sequence # was not printed correctly on the receipt. This is fixed in
SP3.
Discover Update
This update contains changes to support new Discover test cases E2E_17 and E2E_54.
Visa Plus Update
This update contains a fix for a specific Visa Plus card that was causing an application error.
ADVT Test Case 8
Previously Visa was allowing ADVT Test Case 8 to not fallback since the test was informational
only. The latest EMV spec now specifies this test should fallback.
MasterCard 9C Tag
For MasterCard, 9C tag should be 30 for balance inquiries and 92 for PIN change.
JCB/DNA AIDs
Change JCB AID to A0000000651010 and DNA to A0000006200620. Some JCB cards were
not partially matching correctly. Also corrected the TAC Default value: FC6024A800.
POS Entry Mode Flag
Previously the POS Entry Mode Flag, indicating a fallback transaction, would be sent anytime
the ATM falls back to magstripe. Per US EMV guidelines, this has been changed to only send
this flag if the terminal cannot read the card’s chip due to technical issues with the chip.
Revision History
Date
August 2, 2016
Version
1.0
Description of Change
Initial version
ARGO 12 3.3.2 SP3 US Common AID Update Software Release Notes
Triton Systems
Page 5 of 5
August 2, 2016