Low Voltage Energy Aerial fuse switch disconnector Fuse switch disconnector 100A and 160A Créateur en équipement électrique Application K 49X Description Fuse switch disconnector 6-95mm² - 100A and 160A: - The terminals are completely insulated. Connection is established using insulation piercing technology. - The tightening efficiency of the conductors is ensured by two shear head screws on top body. - The conductors are inserted on side. - The fuse holder is opened, removed and closed using a hook stick for K 292 and a pigtail stick for K 291. Note: the fuse holder can be installed without fuses. - The polarity test points are accessible on each terminal without removing the fuse holder. - The degree of protection is IP33. 196 LV protection and cabinets 58 Installation FSD 22x58: FSD size 00: -Insert the fuse into the housing provided on the fuse holder. -Position the assembly on the end of the stick. -Insert the assembly into the FSD up to the stop. -Insert the fuse into the housing provided on the fuse holder. -Position the assembly on the end of the pole. -Place the fuse holder axes in their housings on the "SUPPLY" side. Comment: the "V" shape of the fuse holder can be used as a guide. -By rotating, slide the fuse holder into the FSD up to the stop. Designation Weight (kg) Sales unit K 291 SINGLE PHASE FSD 100A (Size 22x58) 0.507 1 K 292 SINGLE PHASE FSD 160A (Size 00) 0.468 1 K 490 SINGLE PHASE FSD 100A G2 (Size 22x58) (WITH NUMBER PLATE) 0.400 20 K 491 SINGLE PHASE FSD 100A G2 (Size 22x58) (WITHOUT NUMBER PLATE) 0.385 20 K 492 NUMBER PLATE FOR FSD K491 / CABLE 0.025 100 Accessories K 291 K 292 Fuse switch disconnector 6-35mm² - 100A: - The terminals are completely insulated. Connection is established using insulation piercing technology. - The tightening efficiency of the conductors is ensured by two shear head screws on side body. - The conductors are inserted from below. - The fuse holder is opened, removed and closed using a pigtail stick (Note: the fuse holder can be installed without fuses). - The screw heads and fuse holder can be sealed if necessary. - The degree of protection is IP33. 240 K 49X Connection "LEADING-IN" AND "LEADING-OUT" TERMINAL It can be implemented on a live line, but with no load on the conductor section: Al-Cu 6-95mm² for the K29x, and Al-cu 6-35mm² for the K49x. The terminals use insulation piercing technology: - Insert the conductor fully into the terminal (the length as well as the insertion inclination are indicated on the FSD). - Tighten using a 13mm spanner until the shear head breaks. Note: The second screw head is only provided for possible dismantling. Do not use it to re-tighten the screw after the first head has broken. Code 137 58 Fixing The FSD can be fixed directly to a bracket using a supplied M8 screw made of stainless steel. K 291 and K 292 can also be fixed on a wall using two 6mm screws. Polarity test for the K 291 and K 292 only A space is provided to access each terminal in order to check polarity. 196 154 : 500V : 1 000V : 50 to 60Hz : 100A for K 291 and K 49X, and 160A for K 292 The bracket is made of galvanised steel highly resistant to corrosion. Fixing on a pole or façade is achieved by two 10mm diameter galvanised steel screws and two holes on the bracket (top hole having a key shape to make it easier to position the FSD). The adaptor made of synthetic materials is designed to fix a fuse switch disconnector on a "swan neck" type bracket. It can also be fixed using a strap or 2 screws. Bracket K 297 Code Designation Adaptor K 295 Weight (kg) Sales unit K 295 PLASTIC ADAPTOR FOR SINGLE PHASE FSD BRACKET 0.066 5 K 297 BRACKET FOR SINGLE PHASE FSD 0.493 30 SEE SHEET 92 LV Connection / Tools & accessories / LV insulated toolings SEE SHEET 50 LV protection and cabinets / Fuse cartridge Dimensions in mm 116 Non-contractual photos and drawing. MICHAUD Export reserves the right to modify characteristics without any prior notice. SEE SHEET LV protection and cabinets / Operating stick This range meets the criteria of IEC 60 947-3. 15.01 15.01 Non-contractual photos and drawing. MICHAUD Export reserves the right to modify characteristics without any prior notice. 117 Lv protection and cabinets K 292 - Rated voltage, Ue - Rated insulation voltage, Ui - Rated frequency - Rated current, Ie Implementation This fuse switch disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. 3 types of FSD are available: - K 291 is suitable for a 22x58 100A fuse (according to IEC 269-2.1), - K 292 is suitable for a 160A fuse or 240A size 00 solid connecting links (according to IEC 269-2.1). For both references, the insulated conductor section ranges from Al-Cu 6 to 95mm². - K 49X is designed to receive a neutral tube or a AD 100A maximum, size 22x58 fuse cartridge (according to IEC 269-2.1). The Al-Cu insulated conductor section ranges from 6 to 35mm². K 291 Ratings
© Copyright 2025 Paperzz