TCAT612 600mm × 1200mm LED Twin Contemporary Architectural Troffer PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing, reflectors and end caps are die formed code gauge cold rolled steel. High transmission extruded acrylic lenses feature custom formulation for high efficacy without pixelation. FEATURES • Twin lens configuration • High efficiency acrylic lenses feature custom formulation for high performance without pixelation • Appropriate for offices, schools, medical, and public spaces • High performance reflector with matte white paint standard • 60,000 hour LEDs at L80 (up to 86,000 projected life) for reduced maintenance* • Four LED color choices and 82 or greater CRI • Eight lumen packages • Multiple driver options to satisfy different applications • LED modules and electrical accessible from below • Optional architecturally styled integration of daylight and occupancy sensor(s) • QR code traceability • Integral battery pack optional on most models • Compatible with Dual-Lite inverters • Recessed, surface or cable mount • Five year warranty (Terms and Conditions apply) • DesignLights Consortium® (DLC) qualified; see www.designlights.org CERTIFICATION All luminaires are built to UL1598 and 2108 standards, and bear appropriate CSA labels. Damp location is standard. Emergency-equipped fixtures labeled UL 924 and Dry Location unless specified. Adheres to LM79, LM80, and TM21 industry standards. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www. designlights.org. SHIELDING Removable lenses and center channel for easy access to LED module and electrical components. FINISH All reflective surfaces are finished after fabrication with unique formula high reflectivity matte white paint for soft, uniform illumination. IC RATING IC label is standard for recessed products. WARRANTY Five year warranty (Terms and Conditions apply). INSTALLATION An access plate is furnished with each luminaire for fast wiring access without the necessity to open the fixture or wireway. CEILING COMPATIBILITY Luminaire fits recessed exposed Grid ceilings (G); four integral NEC compliant T-bar clips are standard. Can be placed in Slot Grid (SG) style ceiling with regress 9.5mm above ceiling plane. A Flange Kit (FK) accessory is available for recessed hard ceiling applications. Surface Mount (SM) option allows placement below ceiling plane. Cable Mount (CM) option allows suspension below ceiling plane. * Lifetime hours based on TM21-11 calculations ORDERING INFORMATION TCAT 612 EXAMPLE TCAT612-35MLG-ESDU – MODEL – COLOR TEMPERATURE TCAT LED Twin Contemporary Architectural Troffer 30 35 40 50 SIZE 3000K 3500K 4000K 5000K – CEILING TYPE VOLTAGE G Grid Lay-in1 SM Surface Mount CM Cable Suspended Mount2 U 120V-277V 347 347V LUMEN OUTPUT 612 600mm x 1200mm XW Extra Low Watt VW Very Low Watt MW Medium Low Watt LW Low Watt ML Medium Lumen HL High Lumen VL Very High Lumen XL Extra High Lumen See Product Availability Table below. DRIVER E ESD ED ED1 LUTH Fixed Output Step Dimming3 0-10V Dimming 0-10V 1% Dimming Hi-lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology3,4 LUT5 5-Series EcoSystem LED driver3,4 DRIVER AVAILABILITY TABLE E ED ED1 ESD LUT5 LUTH XW X X X VW X X X MW X X X X X X X Page 1/3 Rev. 02/27/17 LW X X X X X X ML X X X X X X HL X X X X X X VL X X X X XL X X X X For drywall, order G with Flange Kit Accessory. Order hanger accessories separately Not available in 347V 4 For compatability with Dual-Lite LiteGear® inverters, contact Hubbell Lighting Representative 5 Only available with 0-10V Dimming (ED) Driver Option. 6 Not available with ESD, LUTH or LUT5. 7 VIVE is a trademark of Lutron Electronics Co., Inc. For questions about configuration options, contact Hubbell Representative. 1 2 OPTIONS ELL14 C388 C488 C588 GLR EOR INT CP NYC ODP LV Emergency Battery Pack Installed, 1400 Lumens3,4 3-Wire Flex 4-Wire Flex 5-Wire Flex Fast Blow Fuse End of Row (SM and CM only. Provides end wiring access for continuous row mounting.) Intermediate (SM and CM only. Provides ends with wiring access for continuous row mounting.) Chicago Plenum NYC Compliant Occupancy and Daylight Sensors, Philips3,5 Lutron Vive Enabled, 0-10V6,7 ACCESSORIES (ORDER SEPARATELY) FK612 600mm x 1200mmSingle Flange Kit (Shipped separately) CM48Y2SC3F-KIT 1200mm Cable Mount Kit for 600mm wide Cable Mount fixtures, 3 Wire 3 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / TCAT612 TCAT612 600mm × 1200mm LED Twin Contemporary Architectural Troffer Product Availability Lumen Package Lumens Input Watts LPW TCAT612-30XWG 2493 19 131.2 TCAT612-35XWG 2568 19 135.2 TCAT612-40XWG 2608 19 137.3 TCAT612-50XWG 2667 19 140.4 TCAT612-30VWG 3157 25 126.3 TCAT612-35VWG 3251 25 130.0 TCAT612-40VWG 3302 25 132.1 TCAT612-50VWG 3595 25 143.8 TCAT612-30MWG 3558 28 127.1 130.9 TCAT612-35MWG 3665 28 TCAT612-40MWG 3722 28 132.9 TCAT612-50MWG 4053 28 144.8 TCAT612-30LWG 4152 34 122.1 125.8 TCAT612-35LWG 4276 34 TCAT612-40LWG 4343 34 127.7 TCAT612-50LWG 4729 34 139.1 TCAT612-30MLG 4713 39 120.8 TCAT612-35MLG 4855 39 124.5 TCAT612-40MLG 4930 39 126.4 TCAT612-50MLG 5368 39 137.6 TCAT612-30HLG 5368 45 119.3 TCAT612-35HLG 5530 45 122.9 TCAT612-40HLG 5615 45 124.8 TCAT612-50HLG 6115 45 135.9 TCAT612-30VLG 6883 55 125.1 TCAT612-35VLG 7090 55 128.9 TCAT612-40VLG 7200 55 130.9 TCAT612-50VLG 7840 55 142.5 TCAT612-30XLG 8321 69 120.6 124.2 TCAT612-35XLG 8571 69 TCAT612-40XLG 8704 69 126.1 TCAT612-50XLG 8932 69 129.4 Page 2/3 Rev. 02/27/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / TCAT612 TCAT612 600mm × 1200mm LED Twin Contemporary Architectural Troffer PHOTOMETRIC DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet Test #16567 Test Date 8/13/2016 ZONAL LUMEN SUMMARY TCAT612-35LWx-EDU TCAT LED Troffer, Recessed Architectural 2x4 LED with Acrylic Refractor XI040C110V054BST1 1.00 LED 4276 33.50 Recessed 0º = 90 90º = 90 0º = 1.19 90º = 1.26 Length: 3.92 Width: 1.92 Height: 0.00 Zone INDOOR CANDELA PLOT 90 Lumens % Lamp % Fixt. 0-30 1236 28.9 28.9 0-40 2007 46.9 46.9 0-60 3453 80.7 80.7 0-90 4276 100.0 100.0 0-180 4276 100.0 100.0 75 800 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 128 Non-Compliant $1.90 based on 3000 hrs. and $0.08 per KWH 1600 0 15 30 45 Horiz 0-180 0.0 45.0 90.0 Test #16570 Test Date 8/13/2016 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY TCAT612-35MLx-EDU TCAT LED Troffer, Recessed Architectural 2x4 LED with Acrylic Refractor. XI040C110V054BST1 1.00 LED 4855 38.90 Recessed 0º = 90 90º = 90 0º = 1.19 90º = 1.26 Length: 3.92 Width: 1.92 Height: 0.00 Zone INDOOR CANDELA PLOT 90 Lumens % Lamp % Fixt. 0-30 1404 28.9 28.9 0-40 2280 47.0 47.0 0-60 3920 80.7 80.7 0-90 4855 100.0 100.0 0-180 4855 100.0 100.0 75 950 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 125 Non-Compliant $1.94 based on 3000 hrs. and $0.08 per KWH 1900 0 15 30 45 Horiz 0-180 0.0 45.0 90.0 Test #16576 Test Date 8/13/2016 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY TCAT612-35HLx-EDU TCAT LED Troffer, Recessed Architectural 2x4 LED with Acrylic Refractor XI054C150V054BST1 1.00 LED 5530 44.60 Recessed 0º = 90 90º = 90 0º = 1.19 90º = 1.26 Length: 3.92 Width: 1.92 Height: 0.00 Zone 0-30 INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 1597 28.9 28.9 0-40 2593 46.9 46.9 0-60 4462 80.7 80.7 0-90 5530 100.0 100.0 0-180 5530 100.0 100.0 90 75 1100 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 124 Non-Compliant $1.95 based on 3000 hrs. and $0.08 per KWH 2200 0 15 30 45 Horiz 0-180 0.0 Page 3/3 Rev. 02/27/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com 45.0 90.0 LED / TCAT612 TCAT612 600mm × 1200mm LED Twin Contemporary Architectural Troffer 23 3/4" DIMENSIONAL DATA — GRID Back of Housing, Grid Recessed Section, Grid 23 3/4" 594mm 47 3/4" 1194mm 4" 102mm 594mm 23 3/4" STANDARD METRIC - 23 25/64" x 47" 23 3/4" 4" CEILING COMPATIBILITY STANDARD METRIC - 23 25/64" x 47" Type G FKCR FK24 Flange Kit Side End Side For lay-in installation in exposed grid ceilings. Maximum tee widths of 25mm and maximum tee heights of 51mm allowed. End For hard ceiling applications, order FK612 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK612 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK612 & (1) FKCR) Row cut out dimensions using FK612s & FKCR adapters: Width 619mm, Length [1219mm × (# in row)] + 9.5mm. Example: (1219mm x 2) + 9.5mm = 2448mm Flange kit cut out dimension for single unit only: 619mm × 1229mm DIMENSIONAL DATA — SURFACE MOUNT OR CABLE MOUNT Surface Section (SM) 51mm 1016mm 44 29/32" 2" 44 29/32" 2" B A B A B B A A B B A 216 215.9 mm 38mm A 8 1/2" 8 1/2" A B A B A A B B A A 12 1/2" B B 89 mm 318mm 12 1/2" Surface Mount: Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 9.5mm, provided in center channel as indicated at left, marked A. 3 1/2" 1245mm 49" 3 1/2" 25" 49" Back of Housing, Surface Mount (SM) and Cable Mount (CM) 635mm 25" 4 5/8" Cable Mount: Order CM ceiling type. Use CM48Y2SC3F-KIT 1219mm Cable Mount Kit for 610mm wide CM trim fixtures. Mounting holes are provided in diagonal straps shown at left, marked B. 117mm 4 5/8" For Cable Mount a 51mm x 76mm access plate with (4) 22mm KOs provided in place of Mounting Collar shown. NOTE: All dimensions are in millimeters; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. * Page 4/3 Rev. 02/27/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / TCAT612
© Copyright 2026 Paperzz