Deck Permit Application Requirements With the submission of a Deck Permit Application please provide the following documents: 1. A complete building permit application form 2. A survey or plot plan showing the property lines and the location of proposed deck dimensioned to all buildings and property lines 3. Two copies of the deck construction drawings. The drawings must have sufficient detail so that someone, following the drawings, could build the deck Construction Drawings The construction drawings must contain the following details: 1. Foundation Plan detailing 2. Footing size and location 3. Size, span, and direction, of beams 4. Size, span, and direction of floor joists and decking 5. Dimensions of all components The construction drawings must contain elevations to demonstrate the following: 1. The general appearance of the deck 2. Cross Section detailing 3. Footing depth and construction 4. Height of deck walking surface above grade 5. Height of guard above walking surface 6. Step details 7. Deck construction 8. Guard construction 9. Details, such as deck to house connection Indicate the following on the Site Plan: 1. Overall deck dimensions 2. Location of deck in relation to house 3. Location of deck in relation to lot lines 4. Stair location(s) and width Guards and Handrails Guards and handrail details must conform to the Ontario Building Code SB-7 Guards for Housing and Small Buildings Guidelines. If using a guard not listed in the SB-7 Guidelines, two copies of manufacturer's installation instructions for proprietary products stamped and signed by an engineer must be submitted. Please ask for details where you purchase the system. Permit Fees Permit fees are calculated based on $0.38/sq.ft, $12/$1000 of the total construction value, or a minimum of twenty five dollars ($25). Accepted methods of payment are cheque, cash, or debit card. Permits are typically issued within ten business days provided the application submission is complete. BUILDING DEPARTMENT 285 County Rd 44, Box 130 Phone: (613)258-9569 ext. 130 Fax: (613)258-1441 ATTACHED DECK NAME: _ BUILDING PERMIT NO: _ ADDRESS: _ REVIEWED BY: _ DATE: _ DATE REVIEWED: _ GUARDS SHALL BE CONSTRUCTED AND CONNECTED AS PER 2012 OBC SUPPLEMENTARY STANDARD SB-7 DETAIL NO.: _______________ FOOTING PLEASE SEE REVERSE SIDE FOR ADDITIONAL INFORMATION BUILDING SECTION LOCATION: 77 Beckwith St N PHONE: 613-283-4124, EXT 1128 FAX: 613-283-0558 ATTACHED DECK BEAM SPANS FOR DECKS FLOOR JOIST SPANS FOR DECKS (2) 2X8………..………..…………….5’-10” (1.8m) (2) 2X10……………………………...7’-2” (2.2m) (2) 2X12……………….……………..8’-4” (2.56m) 2X8@12”.....................................11’-7” (3.54m) 2X8@16”.....................................11’-0” (3.36m) 2X8@24”.....................................10’-6” (3.2m) (3) 2X8……………………….………7’-3” (2.21m) (3) 2X10……………………………...8’-10” (2.7m) (3) 2X12……………………..………10’-3” (3.13m) 2X10@12”...................................13’-8” (4.17m) 2X10@16”...................................13’-0” (3.96m) 2X10@24”...................................12’-4” (3.77m) (4) 2X8………………………….……8’-4” (2.55m) (4) 2X10………………………..……10’-2” (3.12m) (4) 2X12……………………………..11’-10” (3.62m) 2X12@12”...................................15’-7” (4.75m) 2X12@16”...................................14’-9” (4.52m) 2X12@24”...................................14’-1” (4.30m) BUILT UP BEAM SPANS AS PER TABLE A-12 AND A-15 2006 BUILDING CODE JOIST SPANS AS PER TABLE A-1 2006 BUILDING CODE ADDITIONAL INFORMATION (CHECKLIST): 1. INDICATE THE FOLLOWING ON REVERSE PAGE: LENGTH OF LAG BOLTS SIZE OF LEDGER JOIST SPAN AND CANTILEVER BEAM SPAN AND CANTILEVER JOIST SIZE AND SPACING BEAM SIZE AND NUMBER OF PLY POST SIZES TO BE 140mm x 140mm SONO TUBES TO BE MIN. 229mm TO 1200mm BELOW FINISHED GRADE SB-7 DETAIL NUMBER FOR GUARDS (SEE BOOKLET) STAIR CONSTRUCTION 2. INDICATE THE FOLLOWING ON THE PLOT PLAN: OVERALL DECK DIMENSIONS LOCATION OF DECK IN RELATION TO HOUSE LOCATION OF DECK IN RELATION TO LOT LINES STAIR LOCATION (S) AND WIDTH 3. CONFIRM BEAM CANTILEVER WITH INSPECTOR MAX. CANTLEVER FOR 38x184 JOISTS = 400mm MAX. CANTILEVER FOR 38x235 JOISTS = 600mm MAX. CANTILEVER = 1/6 OF JOIST SPAN I (PRINT NAME) HEREBY AGREE TO CONSTRUCT THE DECK IN ACCORDANCE WITH THE SUPPLIED INFORMATION NOTED ON PREVIOUS PAGE AND ABOVE. SIGNATURE: (OWNER/APPLICANT) DATE: _ REFER TO OTHER SIDE FOR FURTHER INFORMATION
© Copyright 2026 Paperzz