ITEM DESCRIPTION QTY UNIT RATE AMOUNT KSHS LIGHTING

BILL NO. 2
ITEM DESCRIPTION
QTY
UNIT
RATE
LIGHTING SYSTEM
Supply, install, test and commission the following items
A
Lighting points wired with 3x1.5mm sq. PVC single core
copper cables drawn in 20 mm Dia. Conduit for one way
switching
33
No
B
Ditto but for two way switching
8
No
C
Switches
1. 10 A One gang one way switch as mem
2. Ditto but two way
3. Two gang two way switch
26
2
2
No
No
No
2
No
2
No
1x36W 1200mm bare batten fluorescent fitting as Thorn
Manufacture Cat. No. PP136 or approved equivalent
1x100W ball fitting as Thorn manufacture Cat. No. MTC
1100
400W floodlight lighting as Thorn manufacture Cat. or
approved equivalent
12
No
9
No
2
No
J
Posttop light fitting complete with lampThorn
manufacture Cat. No. PP136 or approved equivalent
10
No
K
2x8W fluorescent bulkhead lighting fitting as Thorn OBV
2008 or approved equivalent
4
No
D
E
F
H
1
LIGHT FITTINGS
1 X 16 w Oyster lighting fitting as THORN
2DCL 16BR complete with 16W 2D LAMP or approved
equivalent
3 Bulbs Ornamental Chandellier lighting fitting as Thorn
Manufacture or approved equivalent
Total C/F
PAGE I
AMOUNT
KSHS
ITEM DESCRIPTION
A
Total carried from previous page
POWER SYSTEMS
Twin Socket outlet points wired with 3* 2.5mm sq. pvc
single core cables drawn in 20 mm dia. Donduit
QTY
UNIT
10
No
B
13A Twin outlet boxes as MK or approved equivalent
10
No
C
Telephone cord outlet point in concealed pvc conduit
complete with outlet place and draw wire
2
No
D
Telephone outlet box as MK or approved equivalent
2
No
E
Television Aerial cord outlet point in concealed pvc
conduit complete with outlet plate and draw wire
1
No
F
Television outlet box as MK or approved equivalent
1
No
G
5x25.0mm sq. pvc single core cables drawn in 32mm
from cable -loop-in box
20
LM
H
1x16.0mm² 4C PVC/SWA/PVC Cable for the 1no.
passeger lift power
I
9 Way TPN distribution board complete with 80A
Isolator AS crabtree
1
No
J
16 Gauge galvanized steel 250 x 50mm, 2 compartment
wall mounted metal trunking
16
LM
RATE
Total carried to next page
PAGE 2
AMOUNT
KSHS
ITEM DESCRIPTION
Total carried from previous page
A
Circuit breakers as Crabtree
1) 10A
2) 30A
3) 30A
4) 80A TPN
5) blaking plate
Earthing to KP & LC standards
200A Fuse Switch as MEM or approved equivalent
QTY
UNIT
8
5
3
1
6
1
1
No
No
No
No
No
Item
No
D
20A DP switch fuse with cover painted red and an
attached / Label with the conspicuous legend FIRE
ALARM-DO NOT SWITCH OFF , complete with all wiring
in 3x2.5mm dia.pvc conduit from 10A MCB in DB, all
accessories included.
1
Item
E
Break glass call points flash mounted as Menvier Model
No. MBG 913 or approved equivalent.
2
No
2
No
2
No
1
No
B
C
RATE
FIRE ALARM SYSTEM
F
Fire bell Sounders as:(i) 24V DC6" (150mm) as Menvier Model No. MBM 246
or
approved equivalent
(ii) Weather - proof electronic Sounder - deep base
rated 105db as Menvier Model No. MWS 424 or
equivalent.
G
4 zone fire protection control panel complete with 72hr
battery back up all accessories included as Menvier
Model No. MF 9304 or approved equivalent
H
Fire alarm points wired appopriately
10
No
J
smoke detectors as Menvier
Total for lighting and power carried to collection page
10
No
PAGE 3
KSH
ITEM DESCRIPTION
POWER DISTRIBUTION
QTY
UNIT
1
No
Circuit breakers as crabtree as follows:
1) 5A SPN
2) 30A SPN
3) Blanking plates
1
1
10
No
No
No
3
1x4.0mm² 4 c PVC/SWA/PVC cable for ATM machine
30
M
4
1x4.0mm² 4c PVC/SWA/PVC cable for ATM machine
30
M
5
1x10.0mm² 4C PVC/SWA/PVC cable for body scanner
machine
20
M
6
1x10.0mm² 4C PVC/SWA/PVC Cable for luggage scanner
machine
20
M
7
1x4.0mm² 4C PVC/SWA/PVC cable for vehicles access
control machine
40
M
8
1x4.0 mm2 4C PVC/SWA/PVC cable for automatic gate
isolator
20
M
9
60A TPN isolator
6
No
9
Trenching,laying of cables,tilling and backfilling
50
M
10
Earthing the cable loop in box to to Kenya Power and
Electrical Engineers satisfaction
1
Item
1
2
9 Way Distribution board complete with 80A Isolator as
Crabtree
Total for Power switch room and power distribution carried to collection page
PAGE 4
RATE
KSH
ITEM DESCRIPTION
QTY
UNIT
RATE
LIGHTNING PROTECTION SYSTEM
A
25mm x 4mm copper tape down conductor supported
under ridge tiles, at water bonding and all at 1.0m
intervals including junction clamps
40
LM
B
Galvanized Steel conduit 32mm dia. At ground floor
(2.5m) for item (A) above
1
LM
C
Earthing Chamber 300 x 300mm masonary type
complete with removal cover
1
No
D
16mm dia. X 1500mm long pure copper earth rod with
clamp and all accessories
1
No
E
Approved test clamps as furse
1
No
F
Air termination (600mm long pure copper with spikes)
mounted on bracket as furse
3
No
Total for Lightning Protection system carried to Collection
page
PAGE 5
KSH
BILL NO. 2 COLLECTION PAGE
ITEM DESCRIPTION
A
lighting and power sub-total
b
power reticulation sub-total
H
Lightning arrester system sub-total
Page
AmountKsh
Total for Bill No. 2 Carried forward to the price summary page
PAGE 6
Cts
PRICE SUMMARY PAGE
ITEM DESCRIPTION
AMOUNT (KSH.)
1
Total for sub-contract preliminareis (Bill No. 1)
2
Total for Bill No. 2
3
Allow for production of "as installed drawings"
4
Allow for the gate CCTV surveillance system
5
Contigency sum to be expended at the Project Managers
discretion
2,000,000.00
Total Carried to GRAND SUMMARY PAGE IN VOL.1
Total amount in Words: Kenya Shillings ……………………………………………………………………………………………..
………………………………………………………………………………………………………………………………………………………………
Tenderer's Name and Stamp: ……………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………………………………………
Signature: ………………………………………………….
Date: …………………………………………………………..
PIN No. ………………………………………………………
VAT Certificate No. ……………………………………
Witness: …………………………………………………….
Address: ……………………………………………………
……………………………………………………………………
Signature of Witness: ………………………………..
Date: ………………………………………………………….
PAGE 7