Inverter Compatibility Sheet for the ME-ARC with Revision 4.0 The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum inverter and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter to allow these advanced features to be set up or enabled. However, when the ME-ARC is released with a new software revision, some of the features and functionality in this remote may not be available in an inverter or networked accessory that has an earlier software level. In this case, when the advanced setting is requested from the ME-ARC to your inverter (or any other Magnum device networked with the inverter), this setting is not recognized and will not function. Use the steps below to help you determine which ME-ARC (Revision 4.0) menus/features are compatible with your inverter. 1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter’s compatibility level (L1, L2, L3 or L4). 2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter compatibility level is required (see ‘Inverter Model/Level Required’). 3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then your inverter can support the device setting/feature you want. 4. If your inverter does not have the required compatibility level for a feature/setting you want, contact Magnum Energy to determine if there is a software upgrade option for your inverter. ME-ARC (REVISION 4.0) COMPATIBILITY MATRIX Button FEATURES/SETTINGS Main Menu Menu Heading/Item Selections/Adjustments Range Inverter Model/Level Required. CTRL METER Auto Connect ≥Level 1 01 ACIn Control VDC Connect, Time Connect, AC-In Disabled ≥Level 3 [1] SOC Connect ≥Level 3 [1][6] 02 CHG Control Multi-Stage, Start Float, Restart Bulk ≥Level 4 03 Gen Control OFF, ON, AUTO ≥Level 1 [8] Multi-Stage, Charger Off, Start (Float, Bulk, EQ) 04A PT Chg Ctrl ≥Level 1 04 PT Control 04B PT Aux Relay Ctrl DISENGAGE, VDC, FAULT, ENGAGE ≥Level 1 [F] 04C PT Alarm Control OFF, VDC, FAULT, ON ≥Level 1 04D PT MPPT Sweep 5 Min, 15 Min, 1 Hour, Fixed ≥Level 1 01A DC Volts Read only display ≥Level 1 01 DC Meters 01B DC Amps Read only display ≥Level 1 02A Output Volts Read only display ≥Level 4 [3] 02B Output Hz Read only display ≥Level 4 [3] 02C Load Amps Read only display ≥Level 4 [4] 02 AC Meters [5] 02D Input Amps Read only display ≥Level 4 [4] 02E Inv/Chg Amps Read only display ≥Level 4 [4] 02F Input AC (AC1) Read only display MSH Models only 02G Input AC2 Read only display MSH-RE Models 03A Charge Time Read only display ≥Level 1 03 Timers 03B Since Absorb Done [F] Read only display ≥Level 1 03C Since EQ Start [F] Read only display ≥Level 1 04A AGS Status Read only display ≥Level 1 04B DC Volts-AGS Read only display ≥Level 1 04C Gen Run Time Read only display ≥Level 1 04 AGS Meters 04D AGS Temp Read only display ≥Level 1 04E Since GenRun Read only display ≥Level 1 04F Since 100% [F] Read only display ≥Level 1 [7] 04G Hour Meter [F] Display Resettable ≥Level 1 04A BMK Status Read only display ≥Level 1 [7] 04B SOC Read only display ≥Level 1 [7] 04C DC Volts-BMK Read only display ≥Level 1 [7] 04D DC Amps-BMK Read only display ≥Level 1 [7] 04E AH In/Out Read only display ≥Level 1 [7] 05 BMK Meters 04F Reset AH Out Display Resettable ≥Level 1 [7] 04G Total AH Out Display Resettable ≥Level 1 [7] 04H Minimum VDC Display Resettable ≥Level 1 [7] 04I Maximum VDC Display Resettable ≥Level 1 [7] 04J Days Since 100% SOC [F] Read only display ≥Level 1 [7] 06A ACLD Status Read only display ≥Level 1 06B ACLD Power Diverted Read only display ≥Level 1 06 ACLD Meters 06C ACLD Temp Read only display ≥Level 1 [F] 06D Target Volts Read only display ≥Level 1 06E ACLD-X Version Model displays/Read only display ≥Level 1 Magnum Energy, Inc. PN: 64-0030-040 Rev C Default setting. User setting Auto Connect Multi-Stage OFF** Multi-Stage DISENGAGE OFF 15 Min Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Resettable Read Only Read Only Read Only Read Only Read Only Resettable Resettable Resettable Resettable Read Only Read Only Read Only Read Only Read Only Read Only Page 1 of 4 METER 07A 07B 07C 07D 07E 07 PT Meters [F] 07F 07G 07H 07I 07J 01A 01B 01 System Setup 01C 01D 01E 02A 02B 02C 02 Invert Setup 02D 02E 02F 03A 03B SETUP 03 Charger Setup 03D 03E 03F 03G 03H 04A 04B 04 AGS Setup 04C 04D 04E 04F PT Status PV Volts-PT Bat Volts-PT Target Volts Bat Amps-PT PT Status, Power Status, Relay Status ≥Level 1 Read only display ≥Level 1 Read only display ≥Level 1 Read only display ≥Level 1 Read only display ≥Level 1 Now: Read only display Power to Bat Life: Display Resettable ≥Level 1 Reset: Display Resettable Ground Fault Read only display ≥Level 1 PT Data Read only display ≥Level 1 Clear PT Data History Display Resettable ≥Level 1 PT-X Version: Model displays/Read only display ≥Level 1 Set Clock Time= 12:00A-11:59P ≥Level 1 Brightness: 0-100% Screen Setup Contrast: 0-100% ≥Level 1 Pwr Save: OFF, 1-60 Min Temp Display Fahrenheit, Celsius ≥Level 1 Max Charge Amps [F] OFF, 20-990 ADC ≥Level 1 Link PT CHG settings [F] YES, NO ≥Level 1 Search Watts OFF, 5-50 watts (1 watt increments) ≥Level 1 LBCO Setting 9.0-12.2* VDC ≥Level 2 Connect Time= 12:00A-11:45P AC In - Time ≥Level 3 [1] Disconnect Time= 12:00A-11:45P Connect Volts= 9.0-15.9* AC In - VDC ≥Level 3 [1] Disconnect Volts= 9.1-16.0* Connect SOC= 20-99% AC In - SOC ≥Level 3 [7] Disconnect SOC= 21-100% Power Up Always ON, OFF ≥Level 1 AC/AC1 Input= 5-60A ≥Level 1 [1] AC Input Amps AC2 Input= 5-60A MSH-RE Models AC/AC1 Input= 60-100 VAC, UPS Mode US Models VAC Dropout AC2 Input= 60-100 VAC MSH-RE Models 110-190 VAC, UPS Mode Export Models Gel, Flooded, AGM, AGM2 ≥Level 1 Max Chg Amps = (OFF, 20A-990 ADC) CV Charge Volts = (12.0-16.0)* CV Chg Done= (Time, Amps, Hold VDC) CV Chg Done= Time (0.1-25.5 Hrs) Max CC/CV Time= (OFF, 0.1-25.5 Hrs) CC/CV [F] ≥Level 4 ReCharge Volts = (12.0-16.0)* 03C Battery Type CV Chg Done= Amps (0-250 ADC) Max CC/CV Time= (OFF, 0.1-25.5 Hrs) ReCharge Volts = (12.0-16.0)* CV Chg Done= Hold CV Chg VDC Absorb Volts (12.0-16.0)* Float Volts (12.0-16.0)* Custom ≥Level 3 [2] EQ Volts (12.0-16.0)* EQ Done Time (0.1-25.5 Hrs) [F] Time= 0.1-25.5 Hrs ≥Level 4 [5] Absorb Done Amps= 0-150 ADC ≥Level 4 [6] SOC= 50-100% ≥Level 4 [6][7] 10-100% ≥Level 2 Max Charge Rate 0-100% ≥Level 3 Max Charge Time 0.0-25.5 hours ≥Level 4 [6] Final Charge Stage Multi, Float, Silent ≥Level 4 [6] EQ Reminder Days [F] OFF, 1-255 ≥Level 1 Start Gen Volts= 9.0-15.9* Start Volts Delay= 0-127 Sec, 1-127 Min Gen Run VDC ≥Level 1 Stop Gen Volts= 9.1-16.0*, Float Stop Volts Delay= 0-127 Sec, 1-127 Min OFF, ON Gen Run Time Start Gen Time= 12:00A-11:45P ≥Level 1 Stop Gen Time= 12:00A-11:45P Start Gen AC Amps= OFF, 5-60A Start Amps Delay= 0-127 Sec, 1-127 Min Gen Run Amps ≥Level 4 [4] Stop Gen AC Amps= 5-60A Stop Amps Delay= 0-127 Sec, 1-127 Min OFF, Start Gen SOC= 20-90% Gen Run SOC ≥Level 1 [7] Stop Gen SOC= 21-100% Start= OFF, Ext Input, 65-95F (18-35C) Gen Run Temp ≥Level 1 Time= 0.5-6.0 Hrs Max Gen Run Time OFF, 0.1-25.5 Hrs ≥Level 1 Magnum Energy, Inc. PN: 64-0030-040 Rev C Read Only Read Only Read Only Read Only Read Only Read Only Resettable Resettable Read Only Read Only Resettable Read Only 12:00A** 50%** 100%** 15 Min Fahrenheit 200 ADC YES 5 Watts 10.0* VDC 6:00A 6:00P 11.0* 14.1* 50% 100% OFF 30A 20A 80 VAC 75 VAC 150 VAC Flooded 200 ADC 13.8* Time 2.0 Hrs 12.0 Hrs 12.0* 20 ADC 12.0 Hrs 12.0* 14.4* 13.2* 15.6* 4.0 Hrs 2.0 Hrs 20 ADC 100% 100% 12.0 Hrs Multi OFF 11.5* 120 Sec 14.4* 120 Sec OFF 12:00A 12:00A OFF 120 Sec 4A 120 Sec OFF 90% OFF 2.0 Hrs 12.0 Hrs Page 2 of 4 04G 04 AGS Setup 05 BMK Setup 04H 04I 04J 04K [F] 05A 05B OFF, ON Start Quiet Time= 12:00A-11:45P Quiet Time Stop Quiet Time= 12:00A-11:45P Quiet Time Topoff= OFF, 30-120Min Days= OFF, 1-255 days Gen Exercise Run Hour/Min/AM-PM= 12:00A-11:45P Run Time= 0.1-25.5 Hrs Gen Warm-up Time 0-127 Sec, 1-127 Min Gen Cooldown Time 0-127 Sec, 1-127 Min Gen 100% SOC Start Days OFF, 1-255 100% SOC Run Hour/Min/AM-PM= 12:00A-11:45P Charge Eff Auto, 50-97% 200-2500 AH AmpHour Size Gel, Flooded, AGM, AGM2 ≥Level 1 ≥Level 1 ≥Level 1 ≥Level 1 ≥Level 1 [7] ≥Level 1 [7] ≥Level 1 [7] ≥Level 1 Max Chg Amps = (OFF, 20A-990 ADC) 06A Battery Type 13.8* CV Chg Done= (Time, Amps, Hold VDC) Time CV Chg Done= Time (0.1-25.5 Hrs) 2.0 Hrs Max CC/CV Time= (OFF, 0.1-25.5 Hrs) ReCharge Volts = (9.0-16.0)* CV Chg Done= Amps (0-250 ADC) ≥Level 1 SETUP 12.0* Absorb Volts (12.0-16.6)* 14.4* ≥Level 1 EQ Done Time (0.1-25.5 Hrs) 06 PT Setup [F] Amps= 0-150 ADC 13.2* 15.6* 4.0 Hrs 2.0 Hrs Time= 0.1-25.5 Hrs 06B Absorb Done 12.0* 12.0 Hrs ReCharge Volts = (9.0-16.0)* CV Chg Done= Hold CV Chg VDC Float Volts (12.0-16.6)* 12.0 Hrs 20 ADC Max CC/CV Time= (OFF, 0.1-25.5 Hrs) Custom Flooded: 200 ADC CV Charge Volts = (12.0-16.6)* CC/CV [F] OFF 8:00P 10:00A OFF OFF 8:00A 1.0 Hrs 60 Sec 60 Sec OFF 12:00A Auto 400 AH ≥Level 1 20 ADC SOC= 50-100% [6] 06C Max Charge Rate 0-100% ≥Level 1 100% 100% 06D Max Charge Time OFF, 0.1-25.5 Hrs ≥Level 1 12.0 Hrs ≥Level 1 12.0* Daily/SunUp = YES, NO 06E Bulk Start Volts = OFF, 9.0-16.0* YES SOC = 50%-100% [6] 80% Relay Engage Volts = 8.0-16.6* 06F PT Aux Relay Relay Engage Delay = 0-127 Sec, 1-127 Min Relay Disengage Volts = 8.0-16.6* 10.0* ≥Level 1 Relay Disengage Delay = 0-127 Sec, 1-127 Min 06G PT Alarm TECH Magnum Energy, Inc. 14.0* 10 Sec Alarm ON Volts = 8.0-16.6* 10.0* Alarm ON Delay = 0-127 Sec, 1-127 Min 10 Sec Alarm OFF Volts = 8.0-16.6* ≥Level 1 Alarm OFF = 0-127 Sec, 1-127 Min 06H PowerSave PT Display Inv BTS: Inv Tfmer: Inv FETs: AGS Sensor: 01 Temperatures ACLD Temp PT BTS PT FETs PT Inductor Inverter: Remote: AGS: 02 Versions BMK: Router: ACLD: PT: 03 Inv Model: 04A Inv Faults 04A AGS Faults 04 Fault History 04C PT Faults [F] 04D Clear Faults 05 SETUP PIN SETUP PIN = 06 Ext Control 07 Show All Menus [F] 08 Load Defaults Defaults in x.xs 10 Sec OFF, 1-60 Min Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Read only display Display Resettable Unlock SETUP, Lock SETUP, Change PIN Read only display YES, NO Press SELECT (x5 Secs) for default settings PN: 64-0030-040 Rev C 14.0* 10 Sec ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level ≥Level 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 15 Min Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Resettable Unlocked Read Only NO** Read Only Page 3 of 4 * 12-volt values shown; for 24-volts systems - multiply by 2 and for 48-volt systems - multiply by 4. ** These settings return to the factory default setting when power to the remote is removed. [F] Features added to Rev 4.0. ME-ARC (Rev 4.0) Compatibility Matrix Notes: [1] Will not work with MM/MM-E/MM-AE/MMS/MMS-E models. [2] AC Couple Mode activates when Battery Type = Custom with MS-PAE Series ≥Rev 4.1 or MS/MS-PE series ≥5.0. [3] The AC output volts/frequency are only accurate when used with MS, MS-PE, MS-PAE or MSH Series inverters. [4] The AC amps are only accurate and may not be shown unless connected to MS-PE, MS-PAE or MSH Series inverters. [5] Level 2 and 3 inverters can be used, but: Level 2 inverters are limited from 1.0 hour to 4.5 hours, Level 3 inverters <Rev 4.1 are limited from 1.0 hour to 6.5 hours, Level 3 inverters ≥Rev. 4.1 (and MMS Rev 1.5) are limited from 1.5 hours to 6.5 hours; Any setting outside these limited ranges is not recognized and reverts to the inverter's default absorption time (2.0 hours). [6] Requires ≥Level 4 to display. [7] SOC features require the ME-BMK (Battery Monitor Kit) to be installed. [8] To manually turn the generator "ON" with the remote, ME-AGS-N rev 5.0 or higher is required. Magnum Energy, Inc. PN: 64-0030-040 Rev C Page 4 of 4
© Copyright 2026 Paperzz