Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests page page page page 02 02 05 06 1 Description and general specifications. These instruments are used to detect the temperature in the oil filled transformers and are made for outdoor mounting in as well tropical or artic climates (ambient temperature range : -30 / +70°C). All components are made of corrosion resistant or surface treated materials. Casing : aluminium alloy with powder painting high protection degree. On request case can be provided with an air breather device. Nominal diameter : 100mm. or 150mm. Temp. sensing system : expansion type (liquid filled system), compensated for ambient temperature changing by means of a bimetallic spring. Capillary protection : • protective copper tubing • flexible galvanized iron + PVC tubing • flexible AISI 304 tubing. Locking clear window : glass. Locking ring : nickel plated, transparent coated. Standard measuring ranges : -20 / +130°C 0 / +120°C 0 / +150°C 0 / +200°C Measuring accuracy : 1,5% of full scale value. Bulb : brass or stainless steel Liquid filled contact thermometers. These thermometers are equipped with electrical contacts of air type (silver contacts). On request the electrical contacts can be equipped with a little magneto to avoid uncertain commutations when the instruments are subject to vibrations. The contacts can be normally open or normally closed. The opening and closing of contacts are of slow action type. ELECTRICAL CONTACTS MAKING AND BREAKING CAPACITY : ELECTRICAL CONTACTS STANDARD EXECUTION Volt Alternating Current Direct Current Inductive Load 23mA 380 28mA 15mA 220 46mA 40mA 22mA 110 90mA 80mA 45mA 50 170mA 130mA 70mA Volt 380 220 110 50 MAGNETIC ELECTRICAL CONTACTS Alternating Current Direct Current Inductive Load 70mA 80mA 45mA 140mA 125mA 65mA 275mA 240mA 130mA 500mA 380mA 200mA 2 Insulation test : 2000V 50Hz between terminals and earth for a 60 seconds time. Mechanical protection degree : IP 55. THERMOMETER 1144/S DRWG. N. 1144 1144/S 1184/S 1184/S 1186/S 1186/S THERMOMETER 1147/S THERMOMETER 1186/S DRWG. N. 1186 DRWG. N. 1184 nom. Ø 100 100 150 100 150 Elastic suspension : this device is a vibration damping system able to minimize the effects of machine vibrations on the instrument (Drwg. N.1231). DRWG. N. 1147 THERMOMETER 1184/S Type Measuring accuracy : 1,5% of full scale value. A B C 121 121 172 121 172 58 90 91 90 91 79 79 103 / / 3 THERMOMETER 1187-10 nominal diameter 100 DRWG. N. 1187-10 THERMOMETER 1187-15 nominal diameter 150 DRWG. N. 1187-15 THERMOMETER 1187-10 ES nominal diameter 100 DRWG. N. 1187-10-ES THERMOMETER 1187-15 ES nominal diameter 150 DRWG. N. 1187-15-ES 4 Operating instructions and maintenance. Operating instructions : Mounting : a) rigid stem thermometers ( types 1144/S - 1184/S - 1186/S ) fix the connection on the thermometer pocket by means of a spanner. Attention don't try to tighten the connection by rotating the thermometer's head as you may damage it ! Once the connection is fixed you may need to position the dial to get the best readability. The positioning can be made by means of the swivel nut of the thermometer. b) thermometers with capillary (types 1187/S ) : fix the thermometer's head to the machine by means of the back flange or of the elastic suspension. Then fix at regular distances the capillary to the machine wall or cover and position the bulb inside of the thermometer pocket. Finally tighten the connection Contact setting : remove the locking ring remove the glass rotate the frictioned setting pointers till are positioned at the desired set points value put the glass into its seat taking care that the sealing O-ring is correctly located under screw the locking ring BLACK COLOR = ALARM CONTACT RED COLOR = TRIP CONTACT Cable layout : Remove locking ring and glass as done for contacts setting connect the terminals of the contact by taking care that black screws correspond to black pointer contact and red screws correspond to red pointer contact Reposition the glass and mount the locking ring Maintenance : No particular maintenance is required. Only, on regular basis, schedule inspections to verify correct function and calibration. Typically a check of the precision must be done after 24 months and the check for contact functionality must be done at least once a year. In case the transparent is dirty, thus reducing the readability of the dial, you can clean it with a soft cloth, water and soap. 5 Finished product quality control tests. Thermometers without electric contact for distribution transformers Instrument calibration : carried out through thermostatic baths controlled by a microprocessor based monitoring unit. The procedure varies according to instruments scale. The calibration procedure, being the thermometer scale = 0 / +120°C is made by using 5 different baths set at the following temperatures : bath 1 = 0°C bath 2 = 20°C bath 3 = 50°C bath 4 = 100°C bath 5 = 115°C Calibration procedure : Step 1 : a check is carried out to see whether the temperature taken by the instrument under test differs from that taken through the sample sensor by more than the 70% of the maximum allowed instrument reading tolerance value. This test is performed by sequentially plunging the thermometer bulb into successive temperature increasing thermostatic baths : 0°C / +20°C / +50°C / +100°C / +115°C. Step 2 : the instrument is heated until the instrument pointer exceeds by 20% the angular full scale value. Step 3 : step 1 is repeated, but inversely. Check of instrument mechanical protection degree : IP 55 6 Finished product quality control tests. Thermometer with electric contacts (air type silver contacts) for distribution transformers Instrument calibration : carried out through thermostatic baths controlled by a computer system. The procedure varies according to instruments scale. The calibration procedure, being the thermometer scale = 0/+120°C is made by using 5 different baths set at the following temperatures : bath 1 = 0°C bath 2 = 20°C bath 3 = 50°C bath 4 = 100°C bath 5 = 115°C Calibration procedure : Step 1 : a check is carried out to see whether the temperature taken by the instrument under test differs from that taken through the sample sensor by more than the 70% of the maximum allowed instrument reading tolerance value. This test is performed by sequentially plunging the thermometer bulb into successive temperature increasing thermostatic baths : 0°C / +20°C / +50°C / +100°C / +115°C Step 2 : the instrument is heated until the instrument pointer exceeds by 20% the angular full scale value. Step 3 : step 1 is repeated, but inversely. Manual inspection of the electric contact actuation : in every point of the scale. Tripping status control of electric contacts : performed via visual indicators mounted on a panel-board. The bulb is immersed in a thermostatic bath. A Temperature monitoring and control unit changes the temperature inside of the bath and by means of said panel-board the operator verifies the commutation tolerance, the commutation differential, the electrical circuits of each contact. Check of instrument mechanical protection degree : IP 55 I EDITION AUGUST 2006 Insulation test : carried out by means of a microprocessor controlled testing unit. Terman '90 S.r.l., Via Ghisalba, 13-20/21, 20021 Bollate (MI) – Italy. Tel: +39 02 38 30 37 12, Fax: +39 02 38 30 37 19, E-Mail [email protected], www.terman.com C.F./P. IVA IT 09970270154 – C.C.I.A.A. 1332904 – Trib. Milano Reg. Soc. 302729 – Cap. Soc. € 119.000 7
© Copyright 2025 Paperzz