Latitude 8 Moda II Spec Sheet

Latitude™ 8 Moda™II
312 BTE Slim Tube
Signature Features
Speech Enhancement LD
Automatically emphasizes speech signals based on the input level
AutoPro2™
Allows clients to experience superior automatic performance with fast,
smooth transitions between 2 distinct destinations
Enhanced Feedback Management System
Offers adjustable strengths to suppress various degrees of feedback
and provide more usable gain
Smart Control (optional)
A hand-held remote control providing access to volume control,
program change and more
Additional Features
• 8 channels, 8 bands
• Automatic program (2 destinations) + 3 manual programs
• Multiple microphone options: omnidirectional, fixed directional, and
adaptive directional
• Noise Reduction
• AntiShock™
• MyMusic™
• Wind Noise Manager
• Data logging
• Telecoil
Fitting Guide
250 500 1000
2000 4000 8000 Hz
-10
0
10
20
30
40
50
60
70
80
90
100
110
120
open dome
closed dome
sleeve mold
117/45
Latitude 8 Moda II
Latitude™ 8 Moda™ II is suitable for fitting
mild to moderately severe hearing losses
and can fit audiogram configurations ranging
from reverse to precipitously sloping.
unitron.com
09-029 027-5413-02
M4/T4
1.5%
1.3%
1.0%
1.15 mA
130 h
24 dB
92 dB
0 dB
< 100-7800
32 dB
45 dB
35 dB
33 dB
117 dB
109 dB
104 dB
HFA
1.6 kHz
200
500
1000
2000
5000
10000
Hz
5000
10000
Hz
5000
10000
Hz
1000
2000
5000
10000
Hz
70
60
60
50
200
200
200
500
500
500
500
1000
1000
1000
1000
2000
2000
2000
2000
5000
5000
5000
5000
10000
Hz
10000
Hz
10000
Hz
10000
Hz
Battery: 312
Source: Voltage 1.3 V
The measurements obtained with a closed configuration
with a straight measurement micro tube (004-1393) using
a HA-1 coupler (ANSI-3.7-1995) or occluded ear simulator
(EN 60711, coupling arrangement according to fig. 4 in the
test standard).
The hearing instrument set to linear, omni mode with all
adaptive features disabled.
Test Conditions:
80
90
80
70
100
90
500
110
100
200
Pout
dB
Pout
dB
60
2000
50
1000
70
60
500
80
70
200
90
80
110
100
100
90
Pout
dB
10
2000
0
1000
20
10
500
30
20
Pout
dB
40
50
30
40
200
70
200
70
60
80
80
50
90
90
Gain
dB
100
100
Gain
dB
110
120
120
110
Pout
dB
Pout
dB
Current Drain at RTG
Typical Battery Life
Equivalent Input Noise at RTG
Total Harmonic Distortion
at 500 Hz
at 800 Hz
at 1600 Hz
EMC immunity by IEC 60118-13,
Field Strength 75/50 V/m,
Omni mode
IRIL Low/High band dB SPL
Graph shown for 31.6 mA/m at RTG
at RTF
(1 mA/m at Full On Gain)
Maximum
at RTF
Induction Coil Sensitivity
Frequency Range (Hz)
(DIN 45605)
Reference Test Gain
Basic Frequency Response
(input 50 dB)
Maximum
at RTF
Full on Gain
Maximum
at RTF
OSPL90
IEC 118-0
Reference Test Frequency
IEC 118-0 OES COUPLER TECHNICAL DATA
Domes should never be fit on patients with perforated eardrums, exposed middle ear cavities, or surgically altered ear canals. In the case of such a condition, we recommend use of a customized ear mold.
We reserve the right to change specification data without notice as improvements are introduced.
Current Drain at RTG
Typical Battery Life
Equivalent Input Noise at RTG
Total Harmonic Distortion
at 500 Hz
at 800 Hz
at 1600 Hz
EMC ratings by
ANSI C63.19-2001 EMC,
Omni/Telecoil
(ANSI 1996/ANSI 2003,
31.6 mA/m)
HFA SPLITS
STS/RSETS
Induction Coil Sensitivity
Frequency Range (Hz)
Reference Test Gain
(AANSI 1996/ANSI 2003)
Basic Frequency Response
(input 50 dB)
Maximum
HFA
at RTF
Full on Gain
Maximum
HFA
at RTF
OSPL90
ANSI
IEC 118-7
Reference Test Frequency
ANSI 3.22 1996/ANSI 3.22 2003/IEC 118-7 2CC COUPLER TECHNICAL DATA
Latitude 8 Moda II
43/43
1.5%
1.3%
1.5%
1.15 mA
130 h
24 dB
83 dB
75 dB
95 dB
35 dB
< 100-8000
55 dB
41 dB
122 dB
113 dB
1.6 kHz
Latitude 8 Moda II
Latitude™ 8 Moda™II