Latitude™ 8 Moda™II 312 BTE Slim Tube Signature Features Speech Enhancement LD Automatically emphasizes speech signals based on the input level AutoPro2™ Allows clients to experience superior automatic performance with fast, smooth transitions between 2 distinct destinations Enhanced Feedback Management System Offers adjustable strengths to suppress various degrees of feedback and provide more usable gain Smart Control (optional) A hand-held remote control providing access to volume control, program change and more Additional Features • 8 channels, 8 bands • Automatic program (2 destinations) + 3 manual programs • Multiple microphone options: omnidirectional, fixed directional, and adaptive directional • Noise Reduction • AntiShock™ • MyMusic™ • Wind Noise Manager • Data logging • Telecoil Fitting Guide 250 500 1000 2000 4000 8000 Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 open dome closed dome sleeve mold 117/45 Latitude 8 Moda II Latitude™ 8 Moda™ II is suitable for fitting mild to moderately severe hearing losses and can fit audiogram configurations ranging from reverse to precipitously sloping. unitron.com 09-029 027-5413-02 M4/T4 1.5% 1.3% 1.0% 1.15 mA 130 h 24 dB 92 dB 0 dB < 100-7800 32 dB 45 dB 35 dB 33 dB 117 dB 109 dB 104 dB HFA 1.6 kHz 200 500 1000 2000 5000 10000 Hz 5000 10000 Hz 5000 10000 Hz 1000 2000 5000 10000 Hz 70 60 60 50 200 200 200 500 500 500 500 1000 1000 1000 1000 2000 2000 2000 2000 5000 5000 5000 5000 10000 Hz 10000 Hz 10000 Hz 10000 Hz Battery: 312 Source: Voltage 1.3 V The measurements obtained with a closed configuration with a straight measurement micro tube (004-1393) using a HA-1 coupler (ANSI-3.7-1995) or occluded ear simulator (EN 60711, coupling arrangement according to fig. 4 in the test standard). The hearing instrument set to linear, omni mode with all adaptive features disabled. Test Conditions: 80 90 80 70 100 90 500 110 100 200 Pout dB Pout dB 60 2000 50 1000 70 60 500 80 70 200 90 80 110 100 100 90 Pout dB 10 2000 0 1000 20 10 500 30 20 Pout dB 40 50 30 40 200 70 200 70 60 80 80 50 90 90 Gain dB 100 100 Gain dB 110 120 120 110 Pout dB Pout dB Current Drain at RTG Typical Battery Life Equivalent Input Noise at RTG Total Harmonic Distortion at 500 Hz at 800 Hz at 1600 Hz EMC immunity by IEC 60118-13, Field Strength 75/50 V/m, Omni mode IRIL Low/High band dB SPL Graph shown for 31.6 mA/m at RTG at RTF (1 mA/m at Full On Gain) Maximum at RTF Induction Coil Sensitivity Frequency Range (Hz) (DIN 45605) Reference Test Gain Basic Frequency Response (input 50 dB) Maximum at RTF Full on Gain Maximum at RTF OSPL90 IEC 118-0 Reference Test Frequency IEC 118-0 OES COUPLER TECHNICAL DATA Domes should never be fit on patients with perforated eardrums, exposed middle ear cavities, or surgically altered ear canals. In the case of such a condition, we recommend use of a customized ear mold. We reserve the right to change specification data without notice as improvements are introduced. Current Drain at RTG Typical Battery Life Equivalent Input Noise at RTG Total Harmonic Distortion at 500 Hz at 800 Hz at 1600 Hz EMC ratings by ANSI C63.19-2001 EMC, Omni/Telecoil (ANSI 1996/ANSI 2003, 31.6 mA/m) HFA SPLITS STS/RSETS Induction Coil Sensitivity Frequency Range (Hz) Reference Test Gain (AANSI 1996/ANSI 2003) Basic Frequency Response (input 50 dB) Maximum HFA at RTF Full on Gain Maximum HFA at RTF OSPL90 ANSI IEC 118-7 Reference Test Frequency ANSI 3.22 1996/ANSI 3.22 2003/IEC 118-7 2CC COUPLER TECHNICAL DATA Latitude 8 Moda II 43/43 1.5% 1.3% 1.5% 1.15 mA 130 h 24 dB 83 dB 75 dB 95 dB 35 dB < 100-8000 55 dB 41 dB 122 dB 113 dB 1.6 kHz Latitude 8 Moda II Latitude™ 8 Moda™II
© Copyright 2025 Paperzz