MasterForce/KAZ-A Tension Force Measuring System

MasterForce/KAZ-A
Tension Force Measuring System
Application
• Sensor for direc load measurement
in ropes and guy wires
• Assembly technology 9K8
• Inspection of back up devices,
slacklines, climbing equipment
Features
• 1t up to 12 t
• Accuracy class 0.1 %
• Made from stainless steel
• Environmental protection IP 65
Options/ Accessoires
• Sensor, separately
• Accessories according to customer
Dimensions (mm)
D
C
B
A
101
ED9
F
MasterForce KAZ-A/5t mit TEDS-M
sensor detection and display
Rated Load in t
1
2
3.2
5
8
12
A
A
B
C
KAZ-S 1t
148 128
6
KAZ-S 2t
162 136
8
148 170
162 186
KAZ-S 8t
206
170 226
KAZ-S 12t
186
206
226
D
B 47
47
12859
13659
16 69
140
19 69
148
158
176
E
F
8
20
10
25
KAZ-S 3,2t
140
10
12
30
KAZ-S 5t
148
13
16
37
20
48
24
48
158
176
C
D
E
F
Masse
6
8
10
13
16
19
49
49
59
59
69
69
8
10
12
16
20
24
20
25
30
37
48
48
1.3kg
1.5kg
2.0kg
2.2kg
3.2kg
3.5kg
Wiring Code
Cable length 3m
+EX Excitation / Speisespannung
TEDS
TEDS-M Gnd
M
TEDS-M Data
SHI Shield / Schirm
-EX Excitation / Speisespannung
+SI Signal / Signalausgang
-SI Signal / Signalausgang
Specifications
Accuracy Class
Rated force (Fnom)
Maximum operating force (FG)
Breaking force (FB)
Rated characteristic value (Cnom)
Relative deviation of zero signal
Reference excitation voltage (Uref)
Operating range of excitation voltage (BUG)
Input resistance (Re)
Output resistance (Ra)
Insulation resistance (Ris)
Relative linearity error (dlin)
Relative reversibility error (v)
Temperature effect on zero signal (TK0)
Temperature effect on charact. value (TKC)
Relative creep over 30 minutes (dcr, F+E)
Reference temperature (Tref)
Rated temperature range (BT, nom)
Operating temperature range (BT, G)
Storage temperature range (BT, S)
Environmental protection (EN 60529)
% Fnom
t
% Fnom
% Fnom
mV/V
%
VDC
VDC
Ω
Ω
Ω
%
%
%/10K
%/10K
%
o
C
o
C
o
C
o
C
Instrument
Input signal range(Cnom)
Voltage range
A/D-converter resolution
Measurement rate (average value)
Relative linearity error (dlin)
Noise (depend on measurement rate)
Environmental protection (EN 60529)
% Fnom
mV/V
VDC
Bit
Hz
%
% Fnom
0.1
1/ 2/ 3.2/ 5/ 8/ 12
150
>500
1.2 ± 0.2
≤1
10
0.5 ... 12
380 ± 30
352 ± 1.5
> 5 x 109
≤ 0.1
≤ 0.1
≤ 0.1
≤ 0.1
≤ 0.1
+23
-25 ... +60
-30 ... +70
-40 ... +70
IP 65
0.3 ... 5
5
22
6.25 ... 1600
0.0015
0.002 (6.25 Hz) ... 0.04 (1600 Hz)
IP 54
All data according to VDI/VDE/DKD 2638
Order Example
Type Code
MasterForce/KAZ-A/12t
Description
Tension force transducer 12t with TEDS-M connector, display AE 703, incl.
case, software and manual
Rated force
Model
Accessoires
Upon request
for example: plugged cable, connector to the display, lifting accessories.
Data sheet Masterforce KAZ-A • Data subject to change • 09/2014
A.S.T. – Angewandte System Technik GmbH, Mess- und Regeltechnik • Marschnerstraße 26 • 01307 Dresden • Germany • Tel +49 (0)351/ 44 55 491 • www.ast.de