AF/Armaflex

AF/Armaflex
®
Class 0 Self Seal
the World renowned flexible pipe insulation
range with self adhesive closing for
protection against condensation, pipe
freezing and energy losses
•Available in a range of thicknesses and pipe
diameters to meet Domestic Building Services
Compliance Guide, Part L and BS 5422
recommendations
•Save up to £75 per annum off energy bills*
•25mm thick Armaflex pipe insulation on a 15mm
bore copper pipe provides 8 hours frost protection
at -6°C in accordance with BS 5422** (lower
temperatures will require greater insulation
thickness)
•Easy to apply product with self-adhesive seal tubes
and tapes
*, ** See overleaf for details
DBSCG
COMPLIANT
AF/Armaflex
®
Class 0 Self Seal
The Armaflex range is the most recognised brand of
elastomeric pipe insulation, known throughout the
World. Manufactured in the UK the high quality tubes
and sheets have ODP and GWP ratings of zero and are
dust and fibre free. The Armaflex Self Seal range is
especially convenient for the insulation of domestic
central heating and cold water pipes.
Typical system applications
To supply the home with heating and hot and cold
water, pipes run through floors, walls, ceilings and
loft spaces. These pipes can lose up to 80% of their
heat en-route and transmit annoying operating noises
into the building, problems which can be mitigated by
installing Armaflex.
ARMAFLEX SELF sEAL Product RANGE
•AF/Armaflex Class O Self Seal 2m length tubes
are available in 9, 13, 19 and 25 mm wall thicknesses up to 89mm pipe diameter sizes
Pipe insulation reduces these energy losses whilst
also dampening the transmission of nuisance noise
from pipework and preventing condensation on cold
water pipes.
= cold water pipes
= domestic hot water pipes
= heating system pipes
= waste water pipes
The energy and frost protection calculation examples given on the front page are based on the following conditions:
*Save up to £75 per annum based on 80m of 22mm diameter central heating pipework, insulated with 25mm thick AF/Armaflex
Class O, at ambient room temperature of 20°C, line temperature of 70°C, boiler efficiency of 85%, operating for 5 hours a day, 280
days per year with a gas unit price of £0.05 per kWh.
**8 hours frost protection based on initial water temperature of 7°C
AF/Armaflex
®
Class 0 Self Seal
Save energy and protect pipework
against freezing and condensation
energy savings up to 80%
Armaflex pipe
insulation tape
closed-cell foam with low
thermal conductivity
protect pipework from
freezing and heat losses
Your benefit:
AF/ARMAFLEX CLASS O SELF SEAL: Speed up your installation and save up to 30% on labour costs
AF/Armaflex Class O Self Seal is a nitrile rubber pipe insulation product fully slit along each length with two strips of double
sided self adhesive tape pre-applied to each open slit surface. Specially developed to provide insulation where fast, secure
installation is required and ideal for applications where working space is restricted, AF/Armaflex Class O Self Seal is easily
applied by fitting the insulation and peeling back the self adhesive tape. Fast and secure gluing of seams over the entire
length of an installation is ensured, giving a professional finish and aesthetic appearance to the entire installation.
Air Conditioning
Product range
Outside Ø mm
15
22
28
35
42
Steel pipes
Fe
Inch
¼
½
¾
1
1¼
Plastic
pipes
DN mm Outside Ø mm Outside Ø mm
8
13.5 14
15
21.3
20
26.9
25
33.7
32
42.4
Outside Ø mm
15
22
28
35
42
Inch
¼
½
¾
1
1¼
COMPLIANT
DBSCG Compliant Range to meet Part L compliance requirements
Max. Permissable
Thickness [mm]
m/carton
Code
Heat loss [W/m]
AF-CO-19X015-A
AF-CO-25X022-A
AF-CO-25X028-A
AF-CO-25X035-A
AF-CO-25X042-A
7.89
9.12
10.07
11.08
12.19
19
25
25
25
25
78
40
32
24
24
tubes
tapes
AF/Armaflex Class O Frost Protection
Pipe-Ø
Steel pipes
Fe
DBSCG
Tube, length 2 m.
Product range
Copper pipes
Cu
Plumbing
AF/Armaflex Class O DBSCG Range
Pipe-Ø
Copper pipes
Cu
Heating
Tube, length 2 m.
Plastic
pipes
DN mm Outside Ø mm Outside Ø mm
8
13.5 14
15
21.3
20
26.9
25
33.7
32
42.4
Freezing time hours in accordance with BS5422 (min. 8 hours protection)
Code
AF-CO-25X015-A
AF-CO-25X022-A
AF-CO-25X028-A
AF-CO-25X035-A
AF-CO-25X042-A
Freezing Time Hours
8.1
15.5
21.1
30.0
39.4
Thickness [mm]
25
25
25
25
25
m/carton
48
40
32
24
24
tubes
tapes
AF/Armaflex
®
Class 0 Self Seal
Technical data
Material:Elastomeric foam based on synthetic rubber. Flexible closed cell material with built-in Microban® antimicrobial protection.
Applications: Insulation/protection of pipes (heating system pipes, domestic hot and cold water pipes, air conditioning and refrigeration
chilled pipework) and other heating and plumbing installations (incl. elbows, fittings, flanges, etc) to prevent heat losses and
save energy. For high humidity conditions and all chilled and cold water applications Armaflex is the industry standard to
prevent condensation and corrosion issues.
Property
Value/Assessment
Test Certifi1
cate*
Temperature range
Max. service temperature
Min. service temperature
+110° C (+85° C when sheet or tape is glued to flat surfaces)*
-50° C
GB 5165 /
GB 5164
Tested acc. to EN 14706, EN 14707
and EN 14304
at 0° C
≤ 0.034 W/(m ∙ K)*
D 4804
GB 5148
Tested acc. to DIN EN 12667 and EN
ISO 8497
Reaction to fire
Surface Spread of Flames
Class 1
Fire Propagation
Total Index Performance (I)
≤ 12
Sub Index (i1) ≤ 6
Fire Performance acc. to
Building Regulations
Class O
Euroclass - sheets
B-s3, d0
Euroclass - tubes
BL-s3, d0
3
Super2
vison*
Special remarks
Thermal conductivity* λ
λ = [34 + 0,1 ∙ ϑm + 0,0008 ∙ ϑm²]/1000
Resistance to building
materials
resistant against commonly used building materials
like concrete, lime, gypsum, cement
Dimensions & tolerances
In accordance with EN 14313, table 1
UV resistance
Paint with Armafinish 99 when installed outdoors
GB 5151 &
GB 5153
Surface spread of flame: tested according to BS 476 Part 7: 1997
l/m
Fire propagation: tested according to
BS 476 Part 6: 1989
GB 5150 &
GB 5152
Classified according to 13501-1
Tested acc. to EN 13823
EN ISO 11925-2
GB 5164 /
GB 5165
Tested acc. to EN 822, EN 823, EN
13467
*1 Further technical specifications (test certificates, approvals etc.) can be delivered upon request, please quote certificate number.
*2 l = Official supervision by independent institutes and/or test authorities
m = regular in-factory quality monitoring according to prEN14304
*3 In case the insulation is glued with its whole surface directly onto the object and the surface temperature of the object exceeds +85ºC, HT/Armaflex sheets (rolls) should be used.
Armaflex Accessories
• Adhesive Armaflex 520: guarantees a reliable seal at tube butt joins and seams
• Armaflex Cleaner: for cleaning the surfaces to be joined and the tools used
• Armafinish 99: White or grey paint for protecting Armaflex from UV damage
• Cutting sets: 3 piece knife set with sharpening stone
• Ceramic knife: Cuts Armaflex without becoming dulled
Installation hints
ca 20 cm
A
B
Clean all dust, dirt, oil and water from pipework using Armaflex Cleaner where necessary. Install Armaflex when
ambient temperature is between +10 and +35°C. Open
the pre-slit tube and fit over the pipe. Adjust to ensure
the self-adhesive strips are easily accessible. Remove
the white protection paper strips on both sides. Close
the slit seam and squeeze together with firm pressure,
to ensure a permanent seal. The Armaflex can be pushed around long radius bends. Alternatively two piece
elbows can be formed using the cutting template printed on all Armaflex boxes and seal using Armaflex 520
Adhesive* (always cut along the flat side of tubes). The
use of a sharp ceramic cutting knife is recommended
(Armaflex Cleaner available for cleaning adhesive
from tools and Armaflex insulation). Seal all butt joints
with Armaflex 520 Adhesive. Alternatively AF/Armaflex Class O tape can be used to seal joints on central
heating pipework (not suitable to seal joins on cold
applications).
*Optimal evaporation time under normal conditions: 1 min. 30 sec.
All data and technical information are based on results achieved under typical application conditions. Recipients of this information should, in their own interest and responsibility, clarify with us whether or not
the data and information apply to the intended application area. Installation instructions are available in our Armaflex installation manual. Please consult Customer Services before insulating stainless steels.
Adhesive Armaflex 520 must be used to guarantee proper installation. Product not suitable for outdoor use without painting with Armafinish 99.
Armacell UK
Mars Street, Oldham, OL9 6LY · T +44 (0)161 287 7100
www.armacell.com/uk · [email protected]
© Armacell Enterprise GmbH
Armaflex SS | PL | 20130913