Application Instructions Polyaspartic – Quartz Floor These instructions are not intended to show product recommendations for specific service. They are issued as an aid in determining correct surface preparation, mixing instructions and application procedure. These instructions should be followed closely to obtain the maximum service from the product. loss of adhesion. Moisture Vapor Testing is always recommended when coating directly over concrete. Smith’s Polyaspartic Clear 2) Remove paint, adhesives and loose particulates from the intended application surface. 3) A Concrete Surface Profile - CSP 3 to CSP 5 must be Colored Quartz achieved via shot blast or mechanical grinding with a 30 (or Smith’s Polyaspartic with less) metal bonded diamonds. If water is introduced to the Tint/Color intended application area, allow substrate to fully dry. Single Broadcast Quartz Floor – 1/16th inch ≈ 60 mils MIXING INSTRUCTIONS: Mix only that amount of product that can be used in 30 minutes (Smith’s Polyaspartic 1000 Series) or 45 minutes (Smith’s Polyaspartic 2000 Series) Substrate at 72F and 40% RH. Higher temperatures and/or high humidity reduce pot life. The mixing ratio is 1 part A to 1 part B. Measure the amounts carefully and mix counter-clockwise Double Broadcast Quartz Floor – 1/8th " inch ≈ 125 mils for one full minute using a low speed drill, make sure to Smith’s Polyaspartic Clear include the bottom and sides of the mixing container. Do not mix at high speeds to avoid air and moisture entrapment. Colored Quartz Mechanical agitation is recommended Smith’s Polyaspartic Clear APPLICATION METHOD: Smith’s Polyaspartic 1000 and Colored Quartz 2000 Series may be applied via brush, roller and/or squeegee. Smith’s Polyaspartic with ROLLER APPLICATION: Use a 3/8 inch non-shed Tint/Color chemical resistant roller cover. Substrate AREA PREPARATION: Be sure to mask or cover all areas that are not intended to be coated including but not limited to door frames, doors, walls and windows. SURFACE PREPARATION: The surface preparation phase of a polyaspartic floor system should be viewed as the most important. Proper floor preparation results in the product’s longevity, minimizes potential failures and creates the best environment for an aesthetically pleasing installation. In short, the more detail and time allotted to this phase of the project will dramatically affect the appearance and durability of the finished floor. 1) Allow new concrete to cure for at least 28 days. Application of Smith’s Polyaspartic to a damp surface or incompletely cured concrete may cause a hazy appearance or BRUSH APPLICATION: Utilize traditional bristle brush application for corners and edges. INSTALLATION: Cure times based on 72°F – 40% RH 1) Key in all termination points by saw cutting 1/8th inch wide by 1/8th inch deep termination lines at doorways, drain, etc. 2) Apply a body coat of Smith's Polyaspartic1000 or 2000 with Tint at 10 mils ≈ 100 to 160 sq. ft. per gallon via squeegee then back roll with 3/8" Non-shed solvent resistant roller 3) Immediately broadcast decorative Quartz at a rate of 0.4-0.5 lbs. per sq. ft. to full rejection. Allow to cure: • 2000 Slow Cure – 4-5 hours • 1000 Fast Cure – 2-3 hours 4) Sweep up loose Quartz then vacuum entire floor thoroughly to ensure all loose granular has been removed 5) HIGHLY RECOMMENDED - Apply a second body coat of Smith's Polyaspartic Gloss 1000 or 2000 at 10 mils ≈ 100 160 sq. ft. per gallon via squeegee then back roll with 3/8" Non-shed solvent resistant roller 6) Immediately broadcast decorative Quartz at a rate of 0.4-0.5 lbs. per sq. ft. to full rejection. Allow to cure: Smith Paints Products •2200 Paxton Street, Harrisburg, PA 17111• 800/466.8781•www.smithpaints.com Application Instructions Polyaspartic – Quartz Floor These instructions are not intended to show product recommendations for specific service. They are issued as an aid in determining correct surface preparation, mixing instructions and application procedure. These instructions should be followed closely to obtain the maximum service from the product. • 2000 Slow Cure – 4-5 hours • 1000 Fast Cure – 2-3 hours 7) Sweep up loose Quartz, scrape any undesirable ridges using a flat blade drywall tape knife on an extension pole then vacuum entire floor thoroughly ensure all loose granular has been removed. 8) Apply first grout Smith's Polyaspartic Gloss 1000 or 2000 at 7 – 8 mils ≈ 145 sq. ft. per gallon. Allow to cure. • 2000 Slow Cure – 4-5 hours • 1000 Fast Cure – 2-3 hours 9) Repeat grout coat to achieve a more smooth texture Topcoat with •Gloss Finish - Smith's Polyaspartic Gloss 1000 or 2000 at 3-4 mils ≈ 250 to 300 to 250 sq. ft. per. •Low Sheen - Smith's Polyaspartic Low Sheen 1550 or 2550 at 2.5-3.5 mils ≈ 350 to 500 sq. ft. per gallon. * Mil and sq. ft. coverage are theoretical. Substrate porosity will affect coverage rates. APPICATION DIRECTIONS: Material Surface Ambient Humidity Best 60-80°F 65-80°F 65-85°F 10-60% Minimum 50°F 50°F 50°F 0% Maximum 90°F 90°F 95°F 70% - Do not apply when substrate has direct sun - High humidity will decrease pot life. - Smith’s Polyaspartic 4000 Series for low temperature install a calcium chloride test (ASTM F-1869) and/or relative humidity probe (ASTM 2170) should be conducted and is the responsibility of the installer. Smith Paint Products is not responsible for failures due to the presence of moisture vapor emissions and/or high levels of alkalinity. CAUTIONS/WARNING: Material is flammable. Extinguish all flames, pilot lights and electric motors until all vapors are gone and the coating is hard. Keep away from sparks, heat and open flame. Use with adequate ventilation when mixing, applying and curing. Product emits harmful solvent and isocyanate vapors which can cause respiratory irritation. Individuals with chronic lung or breathing problems or negative reaction to isocyanates, should not use this product. The use of a self-contained respiratory equipment (TC 19C NIOSH/MESA) is recommended. Prevent all contact with skin. Use impermeable gloves and chemical resistant eye protection. . RECOATING: Smith’s Polyaspartic should be recoated as soon a previous coat is dry to the touch. If recoating after 24 hours has elapsed, degloss existing sealer film with a black janitor pad, 80-100 grit sandpaper or sanding screen. SLIP RESISTANCE: OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slipresistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. Smith Paint Products recommends the use of angular slip-resistant aggregate in all coatings that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to achieve current safety standards. MOISTURE/ALKALINITY: The absence of an effective moisture vapor barrier may create an environment for moisture vapor transmission as well as high levels of alkalinity in concrete slabs (generally, but not limited to interiors). Introducing an impermeable coating/flooring system to this environment may result in blistering or general failure. Thus, Smith Paints Products •2200 Paxton Street, Harrisburg, PA 17111• 800/466.8781•www.smithpaints.com
© Copyright 2025 Paperzz