Ambu® ACTion™ Fuser 200 ml Pain Pump

Ambu® ACTion™ Fuser 200 ml Pain Pump
Disposable Pain Management System
Key Benefits
• Performance and features common to electrical models in a 100%
mechanical pump.
• Ability to fit the catheter infusion segment to the actual incision site.
• Full flexibility to set & adjust infusion parameters such as: flow rate,
reservoir volume and bolus volume to achieve the optimal nerve
block with sufficient saturation along the entire incision to suit the
needs of the individual patient.
• Reduces cost and minimizes inventory needs due to a high level of
flexibility and modularity.
• Reduces post-operative pain and related need of follow-up
assistance from health care personnel.
• Ambu Regulator Technology allows for consistent flow patterns and
the ability to refill the reservoir.
Completely Latex Safe!
Ambu® ACTion™ Fuser Pain Pump, a disposable pain pump that is mainly designed to give consistent
and customized pain therapy through surgical site infiltration therapy (SSI).
The ability and simplicity to fit the catheter infusion segment to the actual incision length together with
the ability to set the infusion strategy parameters to gain an efficient saturation along the entire
incision is a major advantage of Ambu® ACTion™ Fuser Pain Pump over other pain therapy alternatives.
Ambu® ACTion™ Fuser is intended to be used in hospitals, alternative care sites and at home and
consists of two components; Compression Unit (reservoir) and ACTion™ Fuser Set (regulating set), each
in a separate sterile package.
Such configuration enables users:
(a) to fill the reservoir at a different location while maintaining the sterility of the regulating set
(b) exchange the regulating set in case the flow rate has been locked, but needs to be changed
Regulator
An innovative, patented mechanical flow regulator with exceptional features. Regulator maintains a
uniform accurate flow rate regardless of changes in administration pressure. Furthermore, it enables the
health care provider to select and lock ANY flow rate within its range immediately following priming.
MultiBolus (optional)
A unique patented multivolume mechanical bolus that enables the medical team to select and lock the
bolus volume that best suits the patient’s needs.
(1) Compression
unit (reservoir)
Ambu® ACTionTM Fuser Pain Pump package:
• Compression unit (200 ml)
• Regulating set (several versions of flow rate ranges on
Regulator, with or without MultiBolus)
(4) Multibolus
• Catheter set (introducer + Catheter + Instructions)
• 50/60 cc luer lock disposable syringe
• Wound dressing.
• Medication and pump labels
(6) Catheter
• Carry Pouch
(5) 0.2μ filter
• Physician and Patient Instructions
• Anti-Microbial Dressing
(2) Fill valve
• Flow Splitter (optional)
(3) Regulator
• Lock Guard
COMPONENT
(1) COMPRESSION UNIT (RESERVOIR)
Volume
Fill to any volume between 50 ml to 200 ml.
Refillable
Partial filling
Maximum fill
The reservoir can be re-filled as many time as needed during the duration of use.
The reservoir can be filled partially
300 ml
(3) REGULATOR FLOW REGULATOR
Flow rate range
Stability
1-6 ml/hr or 5-15 ml/hr (depends on version)
±5%
Volume
0, 1, 2, 3, 4, 5 ml (1 ml steps)
Accuracy
±15% of the selected bolus rate
Safety
Secure and permanently locking of the flow rate
(5) 0.2μ FILTER
Safety
The regulating set that the flow regulator is connected to is equipped with 0.2μ filter that provides
a filtration sterilization to avoid any contamination that might occur when filling the reservoir.
OPERATION ENVIRONMENT AND STORAGE
Recommended operation
+20° C (68° F) to +24° C (75° F)
Transport
Avoid exposure to direct sun light and temp over +50ºC (122ºF)
Long term storage
-15ºC (5ºF) to +40ºC (105ºF), avoid exposure to direct sun light
Sterilization: Method
EtO (Ethylene Oxide)
Shelf life: Unopened pouch
3 years from date of manufacture
AMBU® ACTionTM Fuser PAIN PUMP: US ORDERING INFORMATION
ITEM NO.
418
418
418
418
418
418
418
102 200
103 200
106 200
107 200
108 200
111 200
117 200
RESERVOIR
MAX
VOLUME
200
X
X
X
X
X
X
X
Flow Rate
Range
(1-6 ml/hr)
Flow Rate
Range
(5-15 ml/hr)
X
X
X
X
X
X
MultiBolus
(0 to 5 ml)
X
X
Carrying
pouch
X
X
X
X
X
X
X
Catheter
(140 mm,
cut to size)
Catheter
(190 mm,
cut to size)
Introducer
Single
Single
Dual (Splitter)
Single
Dual (Splitter)
Single
Single
6”
6”
6”
9”
6”
4”
6”
UNITS
PER
SHIPPING
BOX
4
4
4
4
4
4
4
ACCESSORIES: ORDERING INFORMATION
ITEM NO.
DESCRIPTION
418
418
418
418
418
418
418
Catheter Set 140 mm (Cut-to-size, 6” introducer, dressing)
Catheter Set 190 mm (Cut-to-size in double sterile pouch)
140 mm Cut-to-size, 6” introducer, dressing
Flow Splitter
Y tubing connector
Closed System Filling Set
Prosit Anti-Microbial Dressing
000 502
000 503
000 504
000 505
000 507
000 508
100 501
UNITS PER SHIPPING BOX
1
1
1
1
1
1
1
Ambu Inc.
6740 Baymeadow Drive Glen Burnie, MD 21060
US: Rx only
Tel.: 1 800 262 8462 Fax: 1 800 262 8673
www.ambu.com
900 002 021 - V01 - Rev 1 - 04/2013 - Ambu Inc. Technical data may be modified without further notice.