C:\Documents and Settings\품질

Y H
Item And Code No.
I T E M
CONNECTOR
S P E C
2.00㎜ Pitch Wire to Board DIP Type
YW200-04
M A K E R
S P E C
Code No.
REMARK
The Best Partner for Electronic Circuits Connections
www.yeonho.com
Specification Approval Sheet
Head Office
& Laboratory
: Yeoksam-dong Gangnam-gu Seoul Korea 14Floor Samikrabidol B/D 720-2
TEL:02)3453-0871 FAX:02)3453-1468
Korea Factory
: 506-2 Hanam-dong Gwangsan-gu Gwangju Korea
TEL:062)952-0772 FAX:062)952-0782
China Factory
: Tian-Mei Industrial North Area Huang Jiang Dong Guan, Guang Dong
TEL:86-769-8)363-2525 FAX:86-469-8)363-5530
Wuxialndustrial Area A10 Donglidistrict Tian Jin, China
TEL:86-22)8445-4110 FAX:86-22)8436-7016
Indonesia Factory
: JL.Industri Selatan 3A SFB blok GG3-C.D.E Jababeka Ⅱ Cikarang, Bekasi 17550, Indonesia
Tel:62-21-898-33225
Fax:62-898-33228
Philippines Warehouse
: Lot2, Block 10, Phase 1, PEZA, Rosario, Cavite, Philippines
Tel:63-46-437-6770
Fax:63-46-437-6772
PRODUCT SPECIFICATION
Pitch
2.00 ㎜
Special
Wire to Board
T y p e
D I P
Y200 Series
Y200 Series
Connector 제품규격
Product Specification
Indemnification
Yeonho will indemnify, hold harmless, and at buyer's request, defend buyer and buyer's directors, officers,
employees, agents and independent contractors from and against any loss, cost, liability or expense
(including court costs and reasonable fees of attorneys and other professionals) arising out of or
resulting from any third party claim that any products and/or components provided by yeonho infringes
patent, copyright, trade secret right or other intellectual property right.
if yeonho receives notice of an alleged patent, copyright, trade secret or other intellectual property right
infringement or if buyer's use of the products and/or the components provided by yeonho shall be prevented
by permanent injunction for reasons of patent, copyright or trade secret infringement, yeonho may, at
its sole option and expense, procure for buyer the right to continued use of the products and/or the
components as provided hereunder, or modify the allegedly infringing item such that it is no longer
infringing, or replace the allegedly infringing item.
● 제,개정 이력『History Revision』
NO
DATE
ISS.
CHK.
APP.
SUMMARY
1
2001.10.15
P.K.H
A.J.I
B.J.S
Presentation
2
2002.10.04
C.A.N
J.J.E
A.J.I
염수분무 시험조건 개정
3
2003.01.21
C.A.N
J.J.E
A.J.I
특허문구 삽입
4
2004.06.07
K.H.S
A.J.I
시험방법 및 시험조건 개정
Yeon Ho Electronics CO.,LTD
1 / 7
PRODUCT SPECIFICATION
Y200 Series
아래와 같이 사양 승인원을 제출합니다.
『Yeon Ho Electronics CO.,LTD. submits the approval certification of connector
specification.』
1. 업
체
명 : (주) 연 호 전 자
『Manufactured by : Yeon Ho Electronics CO.,LTD.』
2. 기 안 부 서 : 품질관리실
『Written by : Quality Control Department』
♠♠♠
목
차 『Contents』 ♠♠♠
1. 적용범위 『Scope』
2. 형명구성 『Numbering System of Products (Ordering Information of Products)』
3. 원 재 료 『Material Specifications』
4. 정
격 『Ratings』
5. 성
능 『Performance Characteristics』
6. 포장 및 식별표시 『Identification & Packing』
♠♠♠
별
첨 『Attachment』 ♠♠♠
1. 검사성적서 『Inspection Data』
2. 사
양
도 『Drawings』
3. 재질증명서 『Material Certification』
4. 유해물질 분석 Data 『The Analysis Data of Toxic Substance』
5. 물질안전보건자료 『MSDS Data』
6. Q.C 공정도 『QC Process Chart』
Yeon Ho Electronics CO.,LTD
2 / 7
PRODUCT SPECIFICATION
Y200 Series
1. 적용 범위 『Scope』
본 사양서는 (주)연호전자 제품 Y200 series DIP type connector에 한하여 적용한다.
『This specification covers the requirements for Y200 series DIP type connector』
2. 형명 구성 『Numbering System of Products(Ordering Information of Products)』
Y W 200 - NN
Number of Circuits
Parts: Straight Wafer
Series Name
Y H 200 - NN
Number of Circuits
Parts: Housing
Series Name
YT200
Parts: Terminal
3. 원재료 『Material』
Item
Material
Maker
Plated / Color
Wafer Material
PA66
LG Chem
White
Housing Material
PA66
LG Chem
White
Pin Material
Brass
C2700
Poong San
* Over plating : Sn(2-6㎛)
Terminal Material
Phosphor Bronze
C5191
Poong San
* Over plating : Pre-plated tin(1-2㎛)
4. 정 격 『Ratings』
항
목 (Item)
정격 전압 (Operating Voltage)
정격 전류 (Current Rating)
정
격 (Standard Data)
AC/DC 125V
AC/DC 3A
사용 온도 (Operating Temperature)
-25℃ ~ +85℃
적용 전선 (Applicable Wire)
AWG #24 ∼ #28
적용 PCB (Applicable P.C.B))
1.2 ~ 1.6 ㎜
Yeon Ho Electronics CO.,LTD
3 / 7
PRODUCT SPECIFICATION
Y200 Series
5. 성 능 『Performance Characteristics』
NO.
시험항목
『Test Title』
1.
외 관 치 수
『Dimensions 』
2.
시 험 방 법 및
조 건
『Test Procedures/Methods Conditions』
규
격
『Requirements』
첨부 제품도에 준한다.
『Refer to drawings』
전 기 적 성 능
『Electrical Characteristics』
2-1.절연저항
⊙ 인접 Terminal(Contact)간에 DC 500V ±5V 전압을
1분±5초간 인가하였을 때 절연저항을 측정한다.
(1회 측정에서 규격 치 미달인 경우 3시간 이내 재측정)
1000㏁ 이상
2-1.Insulation
Resistance
⊙ Measured between adjacent contacts
⊙ Test voltage : DC 500V / 1 Min ±5 Sec
(Based upon MIL-STD-202G Method 302 Condition B)
1000㏁ MIN
2-2.내 전 압
⊙ 인접한 Terminal간에 AC 1000V 전압을 1분±5초간 인가한다. 절연파괴/섬락이 없고
사용상 결함이 없을 것
2-2.Dielectric ⊙ Measured between adjacent contacts
Withstanding ⊙ Test voltage : AC 1000V
Voltage
⊙ Electrification time : 1 Min ±5 Sec
(Based upon MIL-STD-202G Method 301)
No flash over and
no physical damage
shall be observed
2-3.접촉저항
⊙ Terminal과 Wafer Pin간의 접촉저항 측정 20mV. 10mA
30mΩ 이하
2-3.Contact
Resistance
⊙ Measured the resistance of mated connector, 20mV. 10mA
30mΩ MAX
3.
물
3-1.납 땜 성
리
적
성
질
『Physical Characteristics』
⊙ FLUX (ROSIN 10%, METHANOL 90%)에 5∼10초 동안 담근 후
SnAg(3.5)Cu(0.7)의 Pot 납땜조 온도 (240℃±5℃)에
3초±0.5초 동안 침전시킨다.
침전 부위의 납땜이
90% 이상일 것
3-1.
⊙ Immersion in flux consisting of rosin 10% and
Solder Ability
methanol 90% for a period of 5 to 10 seconds dip
in molten solder consisting of SnAg(3.5)Cu(0.7) at
240℃± 5 ℃degrees for 3 ± 0.5 seconds.
More than 90% of
area dipped in molten
solder should be
coated by solder
3-2.납땜내열성
외관 변형등이 없을 것
※ WAVE TYPE
⊙ 온도 260℃±5℃ 5±0.5초간 침적시킨다.
3-2.Solder Heat ※ WAVE TYPE
Resistance ⊙ Solder consisting
: 260℃±5℃ degrees for 5±0.5 seconds
Yeon Ho Electronics CO.,LTD
Appearance : Good
4 / 7
PRODUCT SPECIFICATION
NO.
시험항목
『Test Title』
Y200 Series
시 험 방 법 및
조 건
『Test Procedures/Methods Conditions』
규
격
『Requirements』
3-3.Pin유지력
⊙ 사출물(수지)이 Pin을 유지하고 있는 힘 측정
* Pin을 25±3mm/min 속도로 뺄 때의 힘을 측정한다.
0.5Kgf 이상
3-3.Pin
Retention
Force
⊙ Measured withdrawal force that resin grips and
supports pin
* Velocity of withdrawal : 25 ±3mm/min
0.5Kgf MIN
3-4.총합삽입력
⊙ 회로수가 같은 Housing Ass`Y에 Wafer Ass`Y를 삽입할
때의 힘 측정
3-4.Total
Insertion
Force
⊙ Measured force to insert wafer assembly into
the housing assembly which has same circuits
3-5.총합발거력
⊙ 결합된 Housing Ass`Y로부터 Wafer Ass`Y를 발거할 때의
힘 측정
3-5.Total
Withdrawal
Force
⊙ Measured force to withdraw wafer assembly from
the housing assembly which has same circuits
3-6.내구성시험
⊙ 결합된 제품 Housing Ass`Y과 Wafer Ass`Y의 삽입 및
분리 동작을 10th/min 속도로 30회 행한 후 접촉저항 측정.
3-6.Durability
of Contact
Resistance
⊙ Measured contact resistance after 30 cycles of total
insertion and withdrawal operation.
⊙ Withdrawal Rate : 10th/min.
3-7.Terminal
삽입력
⊙ Housing을 고정시키고 Terminal를 25 ±3㎜/min 속도로
일직선으로 삽입할 때의 삽입력 측정
1.0Kgf 이하
3-7.Insertion
Force of
Terminal
⊙ Insert a terminal into the housing straightly and
measure insertion force
⊙ Velocity of insertion : 25 ±3mm/min
1.0Kgf MAX
3-8.Terminal
조립강도
⊙ Housing에 Terminal을 조립한 후 Terminal을 25 ±3mm/min
속도로 인장시켜 이탈될 때의 힘 측정
0.5Kgf 이상
3-8.Terminal
Retention
Force
⊙ Insert a terminal into the housing and measure
the force to withdraw the terminal from housing
⊙ Apply axial pull out force at the speed rate of
25 ±3mm/minute
0.5Kgf MIN
3-9.압착강도
⊙ Terminal에 Lead Wire를 압착한후 압착부위(심선부위)가
파괴될 때까지 25 ±3㎜/min 속도로 인장강도 측정.
3-9.Crimp
Tensile
Strength
⊙ Measured tensile strength of the crimped contact
(stripped wire barrel section of contact) to conductor joint
Yeon Ho Electronics CO.,LTD
Pos Push(Kgf) Pull(Kgf)
02 2.5 Max 0.70 Min
03 3.0 Max 0.75 Min
04 3.5 Max 0.80 Min
05 4.0 Max 0.85 Min
06 4.5 Max 0.90 Min
07 5.0 Max 1.00 Min
08 5.5 Max 1.10 Min
09 6.0 Max 1.20 Min
10 6.4 Max 1.30 Min
11 6.8 Max 1.40 Min
12 7.2 Max 1.50 Min
13 7.6 Max 1.60 Min
14 8.0 Max 1.70 Min
15 8.4 Max 1.80 Min
접촉저항 : 50mΩ 이하
Contact Resistance
: 50mΩ MAX
AWG #24 : 2.0Kgf MIN
AWG #26 : 1.5Kgf MIN
AWG #28 : 1.0Kgf MIN
5 / 7
PRODUCT SPECIFICATION
NO.
시험항목
『Test Title』
시 험 방 법 및
조 건
『Test Procedures/Methods Conditions』
환
4.
Y200 Series
경
시
험
규
격
『Requirements』
『Environmental Test』
4-1.내진동성
시
험
⊙ DC 100mA 통전상태에서 진폭1.52mm 진동수 10-55-10HZ
1)접촉저항: 50mΩ 이하
진동 상태에서 X,Y,Z방향으로 각각 2시간씩 진동을 시킨 후 2)단전상태: 1μsec
단전상태 및 접촉저항 측정
동안 단전상태 없을것
4-1.Vibration
⊙ Current of 100mA shall be applied during the testing
The vibration shall be along each axis for the
period of two hours with the maximum amplitude of
1.52mm and frequency of 10-55-10Hz/Min
(Based upon MIL-STD-202G Method 201A)
4-2.염수분무
시
험
⊙ Connector를 결합한 상태에서 아래 조건으로 시험 후
1)접촉저항: 50mΩ 이하
흐르는 물에 세척 후 상온에서 4시간 방치 후에 특성을
2)외관: 흑녹현상 없을것
측정한다.
조건: 염수농도 5% ±1%
염수분무 시간 48시간 ±4시간(단,원자재: 2시간 적용함)
시험온도 35℃ ±2℃
4-2.Salt Spray
⊙ Measure after exposure to salt solution spray
of 5 ±1% density at a temperature of 35℃ ±2℃
for 48hrs ±4hrs. (But, material apply to 2hrs)
after test wash and leave to dry
(Based upon MIL-STD-202G Method 101E Condition B)
1)Contact Resistance
: 50mΩ MAX
2)Appearance
: Not black rust
4-3.내습성시험
⊙ Connector를 결합한 상태에서 아래조건에 따라 시험을
행한 후 측정한다.
조건 : 시험조의 온도 40℃ ±2℃
상 대 습 도 90% ∼ 95%
시 험 시 간 96시간
1)절연저항: 500㏁ 이상
2)접촉저항: 50mΩ 이하
3)외관 : 양호할 것
4-3.Humidity
⊙ Mated connector shall be left for 96 hours in an
1)Insulation Resistance
environment of 40 ±2℃, and 90 ∼ 95% humidity.
: 500㏁ MIN
After the exposure the connector shall be left in an ambient 2)Contact Resistance
condition for one hour before the measurement is done
: 50mΩ MAX
(Based upon MIL-STD-202G Method 103B Condition B)
3)Appearance : Good
4-4.내고온성
시
험
⊙ Connector를 결합한 상태에서 시험조의 온도 85 ±2℃에서 1)접촉저항: 50mΩ 이하
96시간 동안 시험 후 상온에서 30분간 방치 후 측정한다.
4-4.Resistance ⊙ Chamber temperature : 85 ±2℃
to High
Exposed 30 minutes after being exposed 96 hours
Temperature
under the chamber temperature electrical
characteristics were measured and tested
(Based upon MIL-STD-202G Method 108A Condition A)
4-5.내한성시험
1)Contact Resistance
: 50mΩ MAX
2)Discontinue
: 1μsec MAX
1)Contact Resistance
: 50mΩ MAX
⊙ Connector를 결합한 상태에서 시험조의 온도 -40 ±3℃에서 1)접촉저항: 50mΩ 이하
96시간 동안 시험 후 상온에서 30분간 방치 후 측정한다.
4-5.Altitude
⊙ Chamber temperature : -40 ±3℃
Low Temperature
Exposed 30 minutes after being exposed 96 hours
under the chamber temperature electrical
characteristics were measured and tested
(Based upon JIS C60068-2-1)
Yeon Ho Electronics CO.,LTD
1)Contact Resistance
: 50mΩ MAX
6 / 7
PRODUCT SPECIFICATION
NO.
시험항목
『Test Title』
시 험 방 법 및
조 건
『Test Procedures/Methods Conditions』
Y200 Series
규
격
『Requirements』
4-6.열충격시험
⊙ Connector를 결합한 상태에서 아래조건에 따라 5회 연속
시험을 행한 후 시험을 실시한다.
단 계
1
2
3
4
+0
+10
+3
온도(℃) -55
25
85
25 +10
-3
-5
-0
-5
시간(분)
30
5
30
5
1)내전압: 절연파괴 및
섬락이 없고 사용상
결함이 없을 것
2)접촉저항: 50mΩ 이하
3)절연저항: 500㏁ 이상
4)외관 : 양호할 것
4-6.Thermal
Shock
⊙ Mated connector shall be exposed five cycles as table #1 1)Dielectric Strength
(Based upon MIL-STD-202G Method 107-A table #1)
: No flash over and
no physical damage
STEP
1
2
3
4
shall be observed
+0
+10
+3
+10
2)Contact Resistance
Temperature (℃) -55
25
85
25
-3
-5
-0
-5
: 50mΩ MAX
Exposed Time (MIN)
30
5
30
5
3)Insulation Resistance
: 500㏁ MIN
4)Appearance : Good
6. 포장 및 식별방법 『Identification and Packing』
1) 포장 조건 『Packing Condition』: Bulk Packing
2) 수
량 『Quantity』
3) 포장 방법 『Packing Method』:
충분한 강도의 종이 BOX를 사용하여 충격을 방지하여 물리적 변형 또는 화학적 변화가
발생되지 않도록 하여야 한다.
『 Carton box for shipment must have enough strength in order to protect physical
damage during transportation.』
4) 식별 표시 : 다음과 같은 사항을 제품포장 BOX에 명기한다.
『Identifications shall be marked as follows』
4-1. 제조회사, 제조자명 또는 상표 『Manufacture's LOGO』
4-2. 형명 또는 부품번호
4-3. 수
『Part Number』
량 『Quantity』
4-4. 제조 LOT NO
『Date Code』
4-5. 기타 상호 필요하다고 인정되는 사항
『Others agreed with manufacturer and customer』
Yeon Ho Electronics CO.,LTD
7 / 7
INSPECTION DATA
DESCRIPTION
Test Title
1-1.Insulation
Resistance
1-2.Dielectric
Withstanding
Voltage
1-3.Contact
Resistance
CONNECTOR
MODEL NO
Test Procedures
YW200-04
Specification
A
Writ`N
CHK`D
APR`D
P
P`
L.J.H
K.S.I
C.G.N
R
TEST CONDITION
Temp:22℃,Humid:65%
X1
X2
X3
X4
X5
Conclusion
GOOD
쐕Test voltage : DC 500V 1minute
1000㏁ MIN
쐕Test voltage : AC 1000V
쐕Electrification time : 1minute
No damage
O.K
O.K
O.K
O.K
O.K
GOOD
쐕Measured the resistance of
mated connector, 20mV. 10mA
30mΩ MAX
7.6
7.8
7.5
7.9
7.7
GOOD
90% MIN
O.K
O.K
O.K
O.K
O.K
GOOD
GOOD
O.K
O.K
O.K
O.K
O.K
GOOD
0.5Kgf MIN
1.62
1.55
1.59
1.48
1.52
GOOD
04P: 3.5Kgf MAX
2.05
2.08
2.10
2.12
2.15
GOOD
04P: 0.8Kgf MIN
1.92
1.95
1.98
1.96
2.00
GOOD
Contact Resistance :
50mΩ MAX
7.9
7.8
7.7
8.1
8.0
GOOD
2-7.Insertion
쐕Insert a terminal into the housing
Force of Terminal straightly and measure insertion force
1.0Kgf MAX
0.33
0.35
0.31
0.34
0.32
GOOD
2-8.Terminal
Retention
Force
0.5Kgf MIN
1.43
1.49
1.48
1.45
1.47
GOOD
AWG #24: 2.0Kgf MIN
4.50
4.62
4.58
4.53
4.63
GOOD
Contact
Resistance
50mΩ MAX
7.7
8.0
7.9
8.1
7.8
GOOD
Discontinue 1μsec MAX
O.K
O.K
O.K
O.K
O.K
GOOD
Contact
Resistance 50mΩ MAX
8.5
8.6
8.9
8.7
8.8
GOOD
Not black
rust
O.K
O.K
O.K
O.K
O.K
GOOD
2-1.Solder Ability 쐕SnAgCu 240±5℃ 3±0.5sec
2-2.Solder Heat
Resistance
쐕260℃±5℃, 5±0.5sec
2-3.Pin
Retention Force
쐕Measured withdrawal force that
resin grips and supports pin
2-4.Total
Insertion Force
쐕Measured force to insert wafer
ass'y into the housing ass'y
which has same circuits
쐕Measured force to withdraw
2-5.Total
wafer ass'y from the housing
Withdrawal Force
ass'y which has same circuits
2-6.Durability
of Contact
Resistance
쐕Measured contact resistance
after 30 cycles of total insertion
and withdrawal operation.
쐕Insert a terminal into the housing and
measure the force to withdraw the
terminal from housing.
쐕 Measured tensile strength of the
2-9.Crimp
Tensile Strength
crimped contact to conductor joint
3-1.Vibration
3-2.Salt Spray
3-3.Humidity
쐕 100mA, 1.52mm, 10-55-10Hz 2hrs
쐕Salt solution : 5±1%
쐕Exposed time : 48hrs ±4hrs
(Material : 2hrs)
쐕Temperature : 35±2℃
쐕Chamber temperature: 40℃±2℃
쐕Relative humidity : 90∼95%
쐕Duration : 96hrs
Appearance
1000㏁ MIN
Insulation 500㏁ MIN
Resistance
GOOD
500㏁ MIN
Contact
Resistance 50mΩ MAX
8.3
8.0
8.2
8.1
8.4
GOOD
Appearance
O.K
O.K
O.K
O.K
O.K
GOOD
Good
쐕Chamber temperature : 85±2℃
쐕Exposed time : 96hrs
Contact
Resistance 50mΩ MAX
7.8
8.0
7.9
8.1
8.2
GOOD
쐕Chamber temperature: -40±3℃
3-5.Altitude
Low Temperature 쐕Exposed time : 96hrs
Contact
Resistance 50mΩ MAX
8.0
7.9
8.1
8.2
7.8
GOOD
Dielectric
Strength
No damage
O.K
O.K
O.K
O.K
O.K
GOOD
Contact
Resistance 50mΩ MAX
8.1
8.3
8.2
8.4
8.5
GOOD
3-4.Resistance
to High Temper
쐕1 Cycle is table #1
쐕After performing 5 cycles
3-6.Thermal
Shock
STEP
1
2
3
4
+0
+10
+3
+10
Temperature
-55
25
85
25
(℃)
-3
-5
-0
-5
Exposed Time
30
5
30
5
(MIN)
Insulation 500㏁ MIN
Resistance
Appearance
Good
GOOD
500㏁ MIN
O.K
O.K
O.K
O.K
O.K
GOOD
Test Report No. F690101/LF-CTSAYAA11-41560
To:
Issued Date: 2011. 12. 30
Page 1 of 5
LG CHEM. LTD.
LG twin tower 23
Yeoeuido-dong
Yeongdeungpo-gu
SEOUL
Korea
The following merchandise was submitted and identified by the client as :
SGS File No.
: AYAA11-41560
Product Name
: LUMID GN1001BF-NP
Item No./Part No.
: N/A
Received Date
: 2011. 12. 27
Test Period
: 2011. 12. 28
Test Results
: For further details, please refer to following page(s)
Test Performed
: SGS Korea tested the sample(s) selected by applicant with following results.
to 2011. 12. 30
SGS Korea Co. Ltd.
Timothy Jeon
Jinhee Kim
Cindy Park
Jerry Jung/ Testing Person
Jeff Jang / Chemical Lab Mgr
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company.
Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
SGS Korea Co.,Ltd.
F052 Version4
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080
t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlab
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYAA11-41560
Sample No.
Sample Description
Item No./Part No.
Materials
Heavy Metals
Issued Date: 2011. 12. 30
Page 2 of 5
: AYAA11-41560.001
: LUMID GN1001BF-NP
: N/A
: N/A
Test Items
Unit
Test Method
MDL
Results
Cadmium (Cd)
mg/kg
With reference to IEC 62321:2008, ICP
0.5
N.D.
Lead (Pb)
mg/kg
With reference to IEC 62321:2008, ICP
5
N.D.
Mercury (Hg)
mg/kg
With reference to IEC 62321:2008, ICP
2
N.D.
Hexavalent Chromium (Cr VI)
mg/kg
With reference to IEC 62321:2008, UV-VIS
1
N.D.
Test Items
Unit
Test Method
MDL
Results
Monobromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Dibromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Tribromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Tetrabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Pentabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Hexabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Heptabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Octabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Nonabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Decabromobiphenyl
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Monobromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Dibromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Tribromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Tetrabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Pentabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Hexabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Heptabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Octabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Nonabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Decabromodiphenyl ether
mg/kg
With reference to IEC 62321:2008, GC-MS
5
N.D.
Flame Retardants-PBBs/PBDEs
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company.
Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
SGS Korea Co.,Ltd.
F052 Version4
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080
t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlab
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYAA11-41560
Issued Date: 2011. 12. 30
Page 4 of 5
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ /PBBs&PBDEs Testing
Cd/Pb/Hg
Cr 6+
PBBs/PBDEs
Cr 6+
Mechanic_Sample
Mechanic_Sample
Mechanic_Sample
Mechanic_Sample
Sample Measurement
Sample Measurement
Sample Measurement
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Solvent Extraction
of the Sample
Nonmetallic Material
Filtration
Residue
Clean-up with Florisil
Column
Concentration/Dilution
of Extraction Solution
Adding Extraction Solution
Metallic Material
Spot Test / Boiling
Water Extraction
Adding 1,5Diphenylcarbazide
for Color Development
Heating to 90~95°C
for Extraction
Filtration and pH Adjustment
Total Digestion
Filtration
Adding 1,5-Diphenylcarbazide
for Color Development
ICP-AES/AAS/MS
DATA
GC/MS
A Red Color Indicates
the Presence of Cr6+
UV-Vis
Confirm
with UV-Vis
DATA
DATA
DATA
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.
Section Chief : Gilsae Yi
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company.
Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
SGS Korea Co.,Ltd.
F052 Version4
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080
t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlab
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYAU12-02138
To:
Issued Date: 2012. 04. 19
Page 1 of 3
POONGSAN CORPORATION
611 Daejung-ri,
Onsan-eup,
Ulju,
ULSAN
KOREA
The following merchandise was submitted and identified by the client as :
SGS File No.
: AYAU12-02138
Product Name
: C2700
Item No./Part No.
: Brass
Received Date
: 2012. 04. 16
Test Period
: 2012. 04. 17
Test Results
: For further details, please refer to following page(s)
Test Performed
: SGS Korea tested the sample(s) selected by applicant with following results.
Conclusion
: Based on the performed tests on submitted sample(s), the results comply with the RoHS
Directive 2002/95/EC and its subsequent amendments.
to 2012. 04. 19
SGS Korea Co. Ltd. / Gimhae Laboratory
Sharpless Park
Jonadan Lee
Taehee Kang
Jongsir Lim/Testing Person
Thomas Hwang / Gimhae Lab. Mgr
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Test Report No. F690101/LF-CTSAYAU12-02138
Sample No.
Sample Description
Item No./Part No.
Materials
Heavy Metals
Issued Date: 2012. 04. 19
Page 2 of 3
: AYAU12-02138.001
: C2700
: Brass
: N/A
Test Items
Unit
Test Method
MDL
Results
Cadmium (Cd)
mg/kg
With reference to IEC 62321:2008, ICP
1
N.D.
Lead (Pb)
mg/kg
With reference to IEC 62321:2008, ICP
5
24.0
Mercury (Hg)
mg/kg
With reference to IEC 62321:2008, ICP
2
N.D.
**
With reference to IEC 62321:2008
-
Negative
Hexavalent Chromium (Cr VI) By boiling
water extraction*
Picture of Sample as Received:
NOTE:(1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Test Report No. F690101/LF-CTSAYAU12-02138
Issued Date: 2012. 04. 19
Page 3 of 3
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ Testing
Cd/Pb/Hg
Cr 6+
Cr 6+
Mechanic_Sample
Mechanic_Sample
Mechanic_Sample
Sample Measurement
Sample Measurement
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Nonmetallic Material
Adding Extraction Solution
Metallic Material
Spot Test / Boiling
Water Extraction
Filtration
Residue
Heating to 90~95°C
for Extraction
Adding 1,5Diphenylcarbazide
for Color Development
Filtration and pH Adjustment
Total Digestion
ICP-AES/AAS
Adding 1,5-Diphenylcarbazide
for Color Development
UV-Vis
A Red Color Indicates
the Presence of Cr6+
Confirm
with UV-Vis
DATA
DATA
DATA
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.
Section Chief : Sharpless Park
*** End ***
NOTE:(1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Test Report No. F690101/LF-CTSAYAU11-04481
To:
Issued Date: 2011. 11. 04
Page 1 of 3
POONGSAN CORPORATION
611 Daejung-ri,
Onsan-eup,
Ulju,
ULSAN
KOREA
The following merchandise was submitted and identified by the client as :
SGS File No.
: AYAU11-04481
Product Name
: C5191
Item No./Part No.
: Phospher Bronze
Received Date
: 2011. 10. 28
Test Period
: 2011. 10. 31
Test Results
: For further details, please refer to following page(s)
Test Performed
: SGS Korea tested the sample(s) selected by applicant with following results.
Conclusion
: Based on the performed tests on submitted sample(s), the results comply with the RoHS
Directive 2002/95/EC and its subsequent amendments.
to 2011. 11. 04
SGS Korea Co. Ltd. / Gimhae Laboratory
Sharpless Park
Jonadan Lee
Taehee Kang
Jongsir Lim/Testing Person
Thomas Hwang / Gimhae Lab. Mgr
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Test Report No. F690101/LF-CTSAYAU11-04481
Sample No.
Sample Description
Item No./Part No.
Materials
Issued Date: 2011. 11. 04
Page 2 of 3
: AYAU11-04481.001
: C5191
: Phospher Bronze
: N/A
Heavy Metals
Test Items
Unit
Test Method
MDL
Results
Cadmium (Cd)
mg/kg
With reference to IEC 62321:2008, ICP
1
N.D.
Lead (Pb)
mg/kg
With reference to IEC 62321:2008, ICP
5
31.0
Mercury (Hg)
mg/kg
With reference to IEC 62321:2008, ICP
2
N.D.
**
With reference to IEC 62321:2008
-
Negative
Hexavalent Chromium (Cr VI) By boiling
water extraction*
Picture of Sample as Received:
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) ** = Qualitative analysis (No Unit)
(6) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Test Report No. F690101/LF-CTSAYAU11-04481
Issued Date: 2011. 11. 04
Page 3 of 3
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ Testing
Cd/Pb/Hg
Cr 6+
Cr 6+
Mechanic_Sample
Mechanic_Sample
Mechanic_Sample
Sample Measurement
Sample Measurement
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Nonmetallic Material
Adding Extraction Solution
Metallic Material
Spot Test / Boiling
Water Extraction
Filtration
Residue
Heating to 90~95°C
for Extraction
Adding 1,5Diphenylcarbazide
for Color Development
Filtration and pH Adjustment
Total Digestion
ICP-AES/AAS
Adding 1,5-Diphenylcarbazide
for Color Development
UV-Vis
A Red Color Indicates
the Presence of Cr6+
Confirm
with UV-Vis
DATA
DATA
DATA
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.
Section Chief : Sharpless Park
*** End ***
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) ** = Qualitative analysis (No Unit)
(6) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility
is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 180 days only.
F055 Version4
SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
LG Chemical
Reg. No.
MSDS
Issue Date
(Material Safety Data Sheet)
LG Twin Tower/ East Wing, 20,
Yoido-dong, Youngdungpo-gu
PA Compound
Seoul 150- 721, Korea
LUMID GN1001BF
Tel : 82-2-3773-7743
Fax : 82-2-3773-7660
DGN1001BF
2003.03.03
4.0
Version
RevIsion
Date
Page
2009.11.04
1/5
1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION
①
②
③
④
Product Name :
Product Type :
Ext. Appearance :
Purpose / Use :
⑤ Manufacture :
⑥ Supplier :
LUMID GN1001BF
PA Compound
Pellet type plastic solid
May be used to produce molded or extruded particles or as a component of
other industrial products.
LG Chemical Ltd. Iksan Plant
599, Yongjei-dong, Iksan-city, Chunbuk-do, 570-350, Korea
Tel) 082-0653-830-4121, Fax) 082-0653-830-4036
LG Chemical Ltd. / 20, Yoido-dong, Yongdungpo-gu, Seoul, 150-721, Korea
Tel) 082-02-3773-1114, Fax) 082-02-3773-7766, 7111
2. COMPOSITION / INFORMATION ON INGREDIENTS
Chemical Name
Polyamide
Polyamide
Melamine Cyanuate
Others
0
0
0
Common Name
Nylon 66
Nylon 6
Additives
CAS Number
32131-17-2
25038-54-4
37640-57-6
0
0
0
Contant (%)
60 ~ 80
5 ~ 20
5 ~ 20
0~5
0
0
0
3. HAZARDS IDENTIFICATION
NFPA RATINGS (SCALE 0-4) : HEALTH=1 FIRE=1 REACTIVITY=0
EC CLASSIFICATION (CALCULATED) : No classification assigned.
EMERGENCY OVERVIEWS :
Solid pellets with slight or no odor. Spilled pellets create slipping hazard.
Can burn in a fire creating dense toxic smoke. Molten plastic can cause severe thermal burns.
Fumes produced during melt processing may cause eye, skin and respiratory tract irritation.
Secondary operations, such as grinding, sanding or sawing, can producs dust which may present an
explosion or respiratory hazard.
POTENTIAL HEALTH EFFECTS :
EYE
: Product may cause irritation or injury due to mechanical action.
SKIN
: Pellets not likely to cause skin irritation.
INGESTION : Not acutely toxic.
INHALATION : Pellet inhalation unlikely due to physical form.
CHRONIC / CARCINOGENICITY :
NTP : Not Tested
OSHA : Not Regulated
IARC : Not Listed
Antimony and its compounds were reported as potential carcinogenic substance.
IARC had classified the glass fiber as noncarcinogenic material.
LG Chemical
PA Compound
LG Chemical
LUMID GN1001BF
Reg. No.
DGN1001BF
Version
4.0
Page
2/5
4. FIRST AID MEASURES
MEDICAL RESTRICTIONS :
EYE
: Remove contract lenses at once. Immediately flush eyes well with copious
quantities of water or normal saline for at least 15-20 minutes. If irritation
persists, seek medical attention.
SKIN
: seek medical attention if rash or burn occurs.
INGESTION : Not probable. If a large amount is swallowed, seek medical attention.
INHALATION : Not Likely to be inhaled due to physical form.
MELT PROCESSING :
For molten plastic skin contact, cool rapidly flush water and immediately seek medical attention.
Do not attempt removal of plastic without medical assistance. Do not use solvent for removal.
For processing fume inhalation irritation, leave contaminated area and breathe fresh air. If coughing,
difficult breathing or any other symptoms develop seek medical attention at once, even if symptoms
develop at a later time.
For skin contact with fume comdiesate, immediately eash thoroughly with soap and water. If irritation
develops seek medical attention.
5. FIRE FIGHTING MEASURES
FIRE FIGHTING :
Approved pressure demand breathing apparatus and pritective clothing should be used for all fires.
Water spray is the preferred extinguishing medium. This product will melt but will not be carried on
the surface for water.
EXTINGUISHING MEDIA :
Water spray and foam, Water is the best extinguishing medium. Carbon dioxide and dry chemical
are not generally recommended because their lack of cooling capacity may permit re-ignition.
HAZARDOUS COMBUSTION PRODUCTS :
Hazardous combustion products may include intense heat, dense black smoke, carbon monoxide,
carbon dioxide, oxides of phosphorus, hydrogen xyanide, hydrocarbon fragments, hydrogen
fluoride, carbonyl fluoride and fluorocarbon fragments.
FLASH POINT
: Not Applicable
LOWER FLAMMABLE LIMIT
: Not Established
UPPER FLAMMABLE LIMIT
: Not Established
AUTOIGNITION
: Not Established
FLAMMABILITY CONDITIONS : Requires a continuous flame source to ignite and sustain combustion.
EXPLOSION DATA
: Not Established
IMPACT SENSITIVITY
: Not sensitive to mechanical impact.
STATIC DISCHARGE
: Not sensitive to static discharge. (See Section 7)
LG Chemical
PA Compound
LG Chemical
LUMID GN1001BF
Reg. No.
Version
Page
DGN1001BF
4.0
3/5
6. ACCIDENTAL RELEASE MEASURES
GENERAL :
Sweep or gather up material and place in preper container for disposal or recovery. (See Section 13)
7. HANDLING AND STORAGE
HANDLING :
Follow recommendations on label and in processing guide. Prevent contact with skin and eyes.
Use good industrial hygiene proctices. Provide adequnte ventilation. Secondary operations such as
grinding, sanding or sawing may produce a dust explosion hazard. Use aggressive housekeeping
activities to prevent dust accumulation; employ bonding, grounding, venting and explosion relief
provisions in accordance with accepted engineering practices.
STORAGE :
Store in a dry place away from moisture, excessive heat and sources of ignition.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS :
A continuous supply of fresh air to the workplace together with removal of processing fumes through
exhaust systems is recommended. Processing fume condensate may be a fire hazard and toxic;
remove periodically from exhaust hoods, duct work amd othwr suricaces using appropriate
personal protection. For piwders and residual dusts refer to Section 7.
PERSONAL PROTECTION :
EYE/FACE
: Wear safety glasses with side shields or chemical goggles. In addition, use
full face shield when cleanning processing fume condensates from hoods,
ducts and other surfaces.
RESPIRATORY
: When handling fumes are not adequstely controlled, use respirator approved
for protection from organic vapors and acid gases. When dust or powder
from secondary operations, such as grinding, sanding or sawing, are not
adequately controlled use respirator approved for protection from dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
PHYSICAL STATE
: Solid
COLOR AND APPEARANCE : Plastic pellet with slight odor
BOILING POINT
: Not Applicable
MELTING POINT (℃)
: 260 ~ 270
VAPOR PRESSURE (mmHg) : Negligible
VAPOR DENSITY (Air=1)
: Not Applicable
SPECIFIC GRAVITY
: 1.15 ~ 1.25
WATER SOLUBILITY
: Insoluble
LG Chemical
PA Compound
LG Chemical
LUMID GN1001BF
Reg. No.
Version
Page
DGN1001BF
4.0
4/5
9. PHYSICAL AND CHEMICAL PROPERTIES (continued)
SOLVENT SOLUBILITY
: Slightly soluble in strong polar slovent or chlorinated solvents
% VOLATITLES
: Negligible
pH
: Not Applicable
ODOR THRESHOLD
: Not Established
EVAPORATION RATE
: Negligible
COEFFICIENT WATER / OIL DISTRIBUTION : Not Established
COMMENT
: This product does not exhibit a sharp melting point, but softens
gradually over a wide temperature range.
10. STABILITY AND REACTIVITY
STABILITY : Stable under recommended conditions of Section 7
REACTIVITY : Not reactive under recommended conditions of handling, storage, processing and use.
CONDITIONS TO AVOID :
Do not exceed melt temperature recommendations in product literature.
In order to avoid autolgnition/hazardous decomposition of hot thick meases of plastic, purgings should
be collected in small, flat shapes or thin strands to allow for rapid cooling and quenching in water.
Do not allow product to remain in barrel at elevated temperatures for extended periods of time ;
purge with a general purpose resin. (See Section 8 for respiratory protection advice)
HAZARDOUS DECOMPOSITION :
Major decomposition gases are oxidized hydrocarbons (probably carbon monoxide) and steam.
Minor components in decomposition gas may be phenolic compounds, hydrogen bromide, THF, etc.
11. TOXICOLOGICAL INFORMATION
Not Available
12. ECOLOGICAL INFORMATION
Not expected to present any significant ecological problems.
13. DISPOSAL CONSIDERATIONS
RCRA HAZARDOUS WASTE :
Products is not a RCRA hazardous waste.
WASTE DISPOSAL :
Recycling is encouraged. Landfill or incinerate in accourdance with federal, state and local
requirements. Collected processing fume condensates and incinerator ash should be tested to
determine waste classification.
LG Chemical
PA Compound
LG Chemical
LUMID GN1001BF
Reg. No.
Version
Page
DGN1001BF
4.0
5/5
14. TRANSPORT INFORMATION
DOT HAZARD CLASS
PROPER SHIPPING NAME
IDENTIFICATION NUMBER
TDGA
:
:
:
:
Not
Not
Not
Not
Regulated
Regulated
Listed
Listed
15. REGULATORY INFORMATION
Listed below are chemical substances subject to supplier notification requirements.
U.S. REQULATIONS :
TSCA INVENTORY STATUS : This product complies with the Chemical Substance Inventory
requirements of the US EPA TSCA.
CERCLA SECTION 103 (40CFR302.4)
: Not Listed
SARA SECTION 313 (40CFR372.65): Not Listed
SARA HAZARD CATEGORIES, SARA SECTIONS 311/312 (40CFR370.21)
ACUTE
: Not Listed
CHRONIC
: Not Listed
FIRE
: Not Listed
REACTIVE
: Not Listed
SUDDEN RELEASE : Not Listed
STATE REQULATIONS :
California Proposition 65 : Not Listed
EUROPEAN REGULATIONS :
EC NUMBER
: Not assigned
16. OTHER INFORMATION
The information submitted in this MSDS is based on our current knowledge and experience.
Because it is not possible to anticipate all conditions of use additional safety precautions may be
required, we make no warranty.
ABBREVIATIONS :
ACGIH : American Conference of Governmental Industrial Hygienist
DOT : Department of Transportation
EC : European Communities
EPA : Environmental Protection Agency
IARC : International Agency for Research on Cancer
NOISH : National Institute for Occupational Safety and Health
NTP : National Toxicology Program
OSHA : Occupational Safety and Health Administration
RTECS : Registry of Toxic Effects of Chemical Substances
CAS # : Chemical Abstracts Service Number
RCRA : Resource Conservation and Recovery Act
LG Chemical
Date Issued
Revision No
Apr.23.2009
1
Material Safety Data Sheet
Copper & Brass Sales -- Brass Strip, Plate, Wire (C2600, C2680, C2700, C2800, C2801)
Material Safety Data Sheet
Part Number/Trade Name : Brass Strip, Plate, Wire
1. Product and Company Identification
① Item Name: Brass Strip, Plate, Wire (C2600, C2680, C2700, C2800, C2801)
② Company's Name: POONGSAN CORPORATION
③ Company's Address : 611, Daejung-Ri,
Onsan-Up, Ulju-Kun, Ulsan, 689-890, SOUTH KOREA
④ Phone Number : 81-52-231-9302
⑤ Fax Number : 81-52-231-9400
2. Composition
Element
Elementary Symbol
CAS Number
Content
Copper
Cu
7440-50-8
61.0%~70.5%
Zinc
Zn
7440-66-6
39.0%~29.5%
3. Hazard Identification
① Route Of Entry
- Inhalation: YES
- Skin: YES
- Ingestion: YES
② Health Hazard Acute and Chronic
- Copper Inhalation : Fumes may cause metal fume fever.
- Skin: Dermatitis, Keratinzation of the hands & the soles of the feet.
- Copper dust & fume cause irritation of the upper respiratory tract.
③ Carcinogenicity : None
4. First Aid Measures
① Inhalation : Breathing difficulty caused by inhalation of particulate requires immediate removal to
fresh air. If breathing has stopped, perform artificial respiration and obtain medical help
② Ingestion : Induce vomiting immediately as directed by medical personnel. Never give anything by
mouth to an unconscious person.
③ Skin : Thoroughly wash skin cuts or wounds to remove all particulate debris from the wound. Seek
medical attention for wounds that cannot be thoroughly cleansed. Treat skin cuts and wounds
with standard first aid practices such as cleansing, disinfecting and covering to prevent wound
infection and contamination before continuing work. Obtain medical help for persistent irritation.
Material accidentally implanted or lodged under the skin must be removed.
④ Eyes : Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper
eyelids occasionally. Get medical attention immediately.
5. Fire Fighting Measures
① Unusual Fire And Explosion Hazards : Solid massive form isn't combustible. Molten metal may react
violently water.
② Extinguishing Media : Use special mixtures of dry chemical/sand.
③ Special Fire Fighting Procedures : Pressure-demand self-contained breathing apparatus must be
worn by firefighters or any other persons potentially exposed to the metal fumes or dust release
during or after a fire.
6. Accidental Release Measures
① Steps If Material Released or Spill : Remove by vacuuming/wet sweeping to Prevent heavy
concentration of airborne dust. If liquids containing solubilized metal are spilled evacuate area.
Absorb by mens of vermiculite, dry sand/similar material
7. Handing and Storage
① Handling : Particulate may enter the body through cuts, abrasions or other wounds on the surface
of the skin. Wear gloves when handing parts with loose surface particulate or sharp edges.
② Storage : Store in a dry area.
8. Exposure Controls, Personal Protection
① Allowing concentration
- TWA : 10㎎/㎡ (Total Dust, OSHA Standard)
② Respiratory Protection : If exposure above the PEL/TLV, wear NIOSH/MSHA approved respirator.
③ Ventilation : Local exhaust ventilation.
④ Personal Protection
- Protective Gloves : Required
- Eye Protection : Safety glasses W/side shields
- Other Protective Equipment : Face shields, specially tinted glass.
9. Physical And Chemical Properties
① Physical State : Solid
⑥ Evaporation Rate : Not Applicable
② pH : Not Applicable
⑦ Freezing Point : Not Applicable
③ Melting Point : 900℃
⑧ Radioactivity : Not Applicable
④ Density : 8.50
⑨ Solubility : None
⑤ Odor : None
⑩ Vapor Pressure : Not Applicable
10. Stability And Reactivity
① General Reactivity : The Material is stable
② Incompatibility : Reacts with some acids and caustic solutions to produce hydrogen gas.
Hydrogen gas can be an explosion hazard
③ Hazardous Decomposition Products : None under normal conditions of use
④ Hazardous Polymerization : Will not occur
11. Toxicological information
① No human data are available for this product
12. Ecological Information
① This material is recyclable
13. Disposal Considerations
① Waste Disposal Method : Dispose of low/federal, State & local regulations
② Byproduct Recycling : When recycled(used in a process to recover metals), this material is not
classified as hazardous waste under federal law. Seal particulate or particulate containing materials
inside two plastic bags, place in a DOT approved container, and label appropriately.
③ Solid Waste Management : When spent products are declared solid wastes (no longer recyclable),
they must be labeled, managed and disposed of, in accordance with federal, state and local
requirements.
14. Transport Information
① None reported
15. Regulatory Information
① Occupational Safety and Health Administration
Air contaminants, 29 CFR 1910.1000
Hazard Communication Standard, 29 CFR 1910.1200
16. Other Information
The information above is believed to be accurate and represents the best information currently
available to us. However, we make no warranty of merchantability or any other warranty, express or
implied, with respect to such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the Information for their particular
purposes. If you require more information, please contact us at the location listed on the page of this
report.
Date Issued
Jun.4.2010
Revision No
2
Material Safety Data Sheet
Copper & Brass Sales -- Phosphor Bronze Strip (C5102, C5111, C5191, C5212, C5210, C5240)
Material Safety Data Sheet
Part Number/Trade Name : Phosphor Bronze Strip
1. Product and Company Identification
① Item Name : Phosphor Bronze Strip (C5102, C5111, C5191, C5212, C5210, C5240)
② Company's Name : POONGSAN CORPORATION
③ Company's Address : 611, Daejung-Ri, Onsan-Up, Ulju-Kun, Ulsan, 689-890, SOUTH KOREA
④ Phone Number : 81-52-231-9302
⑤ Fax Number : 81-52-231-9400
2. Composition
Element
Elementary Symbol
CAS Number
Content
Copper
Cu
7440-50-8
89.3%~96.5%
Tin
Sn
7440-31-5
3.5%~10.5%
Phosphorus
P
7723-14-0
0.03%~0.2%
3. Hazard Identification
① Route Of Entry
- Inhalation: YES
- Skin: YES
- Ingestion: YES
② Health Hazard Acute and Chronic
- Copper Inhalation : Fumes may cause metal fume fever.
- Skin: Dermatitis, Keratinzation of the hands & the soles of the feet.
- Copper dust & fume cause irritation of the upper respiratory tract.
③ Carcinogenicity : None
4. First Aid Measures
① Inhalation : Breathing difficulty caused by inhalation of particulate requires immediate removal to
fresh air. If breathing has stopped, perform artificial respiration and obtain medical help
② Ingestion : Induce vomiting immediately as directed by medical personnel. Never give anything by
mouth to an unconscious person.
③ Skin : Thoroughly wash skin cuts or wounds to remove all particulate debris from the wound. Seek
medical attention for wounds that cannot be thoroughly cleansed. Treat skin cuts and wounds
with standard first aid practices such as cleansing, disinfecting and covering to prevent wound
infection and contamination before continuing work. Obtain medical help for persistent irritation.
Material accidentally implanted or lodged under the skin must be removed.
④ Eyes : Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper
eyelids occasionally. Get medical attention immediately.
5. Fire Fighting Measures
① Unusual Fire And Explosion Hazards : Solid massive form isn't combustible. Molten metal may react
violently water.
② Extinguishing Media : Use special mixtures of dry chemical/sand.
③ Special Fire Fighting Procedures : Pressure-demand self-contained breathing apparatus must be
worn by firefighters or any other persons potentially exposed to the metal fumes or dust release
during or after a fire.
6. Accidental Release Measures
① Steps If Material Released or Spill : Remove by vacuuming/wet sweeping to Prevent heavy
concentration of airborne dust. If liquids containing solubilized metal are spilled evacuate area.
Absorb by mens of vermiculite, dry sand/similar material
7. Handing and Storage
① Handling : Particulate may enter the body through cuts, abrasions or other wounds on the surface
of the skin. Wear gloves when handing parts with loose surface particulate or sharp edges.
② Storage : Store in a dry area.
8. Exposure Controls, Personal Protection
① Allowing concentration
- TWA : 10㎎/㎡ (Total Dust, OSHA Standard)
② Respiratory Protection : If exposure above the PEL/TLV, wear NIOSH/MSHA approved respirator.
③ Ventilation : Local exhaust ventilation.
④ Personal Protection
- Protective Gloves : Required
- Eye Protection : Safety glasses W/side shields
- Other Protective Equipment : Face shields, specially tinted glass.
9. Physical And Chemical Properties
① Physical State : Solid
⑥ Evaporation Rate : Not Applicable
② pH : Not Applicable
⑦ Freezing Point : Not Applicable
③ Melting Point : 1,020℃
⑧ Radioactivity : Not Applicable
④ Density : 8.80
⑨ Solubility : None
⑤ Odor : None
⑩ Vapor Pressure : Not Applicable
10. Stability And Reactivity
① General Reactivity : The Material is stable
② Incompatibility : Reacts with some acids and caustic solutions to produce hydrogen gas.
Hydrogen gas can be an explosion hazard
③ Hazardous Decomposition Products : None under normal conditions of use
④ Hazardous Polymerization : Will not occur
11. Toxicological information
① No human data are available for this product
12. Ecological Information
① This material is recyclable
13. Disposal Considerations
① Waste Disposal Method : Dispose of low/federal, State & local regulations
② Byproduct Recycling : When recycled(used in a process to recover metals), this material is not
classified as hazardous waste under federal law. Seal particulate or particulate containing materials
inside two plastic bags, place in a DOT approved container, and label appropriately.
③ Solid Waste Management : When spent products are declared solid wastes (no longer recyclable),
they must be labeled, managed and disposed of, in accordance with federal, state and local
requirements.
14. Transport Information
① None reported
15. Regulatory Information
① Occupational Safety and Health Administration
Air contaminants, 29 CFR 1910.1000
Hazard Communication Standard, 29 CFR 1910.1200
16. Other Information
The information above is believed to be accurate and represents the best information currently
available to us. However, we make no warranty of merchantability or any other warranty, express or
implied, with respect to such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the Information for their particular
purposes. If you require more information, please contact us at the location listed on the page of this
report.
정일자
ESTA. Date
개정일자
REV. Date
시행일자
EFFECT.Date
문서번호
FILE. NO
NO
H O U S I N G
Q C
공 정 도
PRODUCT&PROCESS CHART (HOUSING)
=============================
2004. 03. 17
2004. 03. 17
작성일자 : 2004. 03. 17
Q - M - 001
공정명
PROCESS
NAME
01
원자재 입고
INCOMING
MATERIAL
02
수입 검사
INCOMING
INSPECTION
03
INJECTION
04
공정 및
최종검사
Process&
Final Test
05
포 장
PACKAGE
06
보 관
STORAGE
07
출하 검사
OUTGOING
TEST
D A T E : 2004. 03. 17
흐름도
부공정
주공정
SUB PROCESS MAIN PROCESS
사용설비
및 장비
EQUIPMENT
사 출 기
EJECTOR
작성부서 : 품질관리실
D E P T .: QUALITY CONTROL
공 정 관
리 (MGT OF PROCESS)
항
목
I T E M
작 성 자 : 서 홍 엽
WRITTEN BY : MR.H Y SEO
승 인
APR`D
A S.H.Y B.J.S S.S.S
P
R` 03/17 03/17 03/17
D
검 사 관 리 (MGT OF INSPECTION)
검사항목
ITEM
검사방식
METHOD
판정기준
JUDGEMENT
겉모양(Shape)
물성(Certificate
of Propertied)
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
형체력(Shape)
작업표준
DRY HOPPER온도(DRY HOPPER Temp) STD OF WORK
OIL 온도(OIL Temp)
OIL량(Quantity of Oil)
겉모양(Shape)
AIR 공급량(Air Pressure)
저울,SEALING기 수량(Quantity)
Digital Scale 포장상태(State of Package)
Packer
V/C,공구현미경
V/C,TOOL M/S
관리기준
MGT.RULE
결 작 성 검 토
WRIT`N CHK`D
재
관련표준
STANDARDIZE
YSI-101-003
YSI-091-004
체크검사
CHECK
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
포장관리
규칙
Package
Regulation
YSI-102-001
YSP-152
겉모양(Shape) 체크검사(CHECK) 출하검사 규격
치수(Dimension) 계수조정형샘플링 STD OF OUTGOING
TEST
형합성(Matching) MIL-STD-105D
YSI-102-100
제정일자
ESTA. Date
개정일자
REV. Date
시행일자
EFFECT.Date
문서번호
FILE. NO
NO
W A F E R
Q C
공 정 도
PRODUCT&PROCESS CHART (WAFER)
=============================
2004. 03. 17
2004. 03. 17
작성일자 : 2004. 03. 17
Q - M - 002
공정명
PROCESS
NAME
01
원자재 입고
INCOMING
MATERIAL
02
수입 검사
INCOMING
INSPECTION
03
INJECTION
04
공정 및
최종검사
Process&
Final Test
05
포 장
PACKAGE
06
운 반
STORAGE
D A T E : 2004. 03. 17
흐름도
부공정
주공정
SUB PROCESS MAIN PROCESS
사용설비
및 장비
EQUIPMENT
사 출 기
EJECTOR
작성부서 : 품질관리실
D E P T .: QUALITY CONTROL
공 정 관
리 (MGT OF PROCESS)
항
목
I T E M
관리기준
MGT.RULE
작 성 자 : 서 홍 엽
WRITTEN BY : MR.H Y SEO
포장관리규칙
Package
Regulation
승 인
APR`D
A
P S.H.Y B.J.S S.S.S
R` 03/17 03/17 03/17
D
검 사 관 리 (MGT OF INSPECTION)
검사항목
ITEM
검사방식
METHOD
판정기준
JUDGEMENT
겉모양(Shape)
물성(Certificate
of Propertied)
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
형체력(Shape)
작업표준
DRY HOPPER온도(DRY HOPPER Temp) STD OF WORK
OIL 온도(OIL Temp)
겉모양(Shape)
OIL량(Quantity of Oil)
AIR 공급량(Air Pressure)
저울,SEALING기 수량(Quantity)
Digital Scale 포장상태(State of Package)
Packer
운반차
Carrier
결 작 성 검 토
WRIT`N CHK`D
재
관련표준
STANDARDIZE
YSI-101-003
YSI-091-004
체크검사
CHECK
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
YSI-102-001
YSP-152
제정일자
ESTA. Date
개정일자
REV. Date
시행일자
EFFECT.Date
문서번호
FILE. NO
NO
P I N
Q C
공 정 도
PRODUCT&PROCESS CHART (PIN)
=============================
2004. 03. 17
2004. 03. 17
Q - P - 002
공정명
PROCESS
NAME
결 작 성 검 토
WRIT`N CHK`D
재
작성일자 : 2004. 03. 17
작성부서 : 품질관리실
작 성 자
D A T E : 2004. 03. 17
D E P T .: QUALITY CONTROL
WRITTEN BY : MR.H Y SEO
흐름도
부공정
주공정
SUB PROCESS MAIN PROCESS
사용설비
및 장비
EQUIPMENT
01
원자재 입고
INCOMING
MATERIAL
02
수입 검사
INCOMING
INSPECTION
03
CUTTING
CUTTING
MACHINE
04
공정 및
최종검사
Process&
Final Test
V/C
05
포 장
PACKAGE
06
보 관
STORAGE
07
외주도금
PLATING VENDOR
공 정 관
리 (MGT OF PROCESS)
항
목
I T E M
관리기준
MGT.RULE
포장관리규칙
Package
Regulation
A S.H.Y B.J.S S.S.S
P
R` 03/17 03/17 03/17
D
검 사 관 리 (MGT OF INSPECTION)
검사항목
ITEM
검사방식
METHOD
판정기준
JUDGEMENT
겉모양(Shape)
치수(Dimension)
물성(Certificate
of Propertied)
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
원재료 풀림상태(MATERIAL WINDING) 작업표준
STD OF WORK
CAM고정상태(STATE OF CAM)
PUNCH고정상태(STATE OF PUNCH)
FEEDING 동작상태(FEEDING)
겉모양(Shape)
CHIP가루발생(CHIP OCCURRENCE)
BEARING 및 GEAR 동작상태
(BEARING, & GEAR)
저 울
수량(Quantity)
Digital Scale 포장상태(State of Package)
: 서 홍 엽
승 인
APR`D
관련표준
STANDARDIZE
YSI-102-004
YSI-091-007
체크검사
CHECK
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
YSI-102-004
YSP-152
제정일자
ESTA. Date
개정일자
REV. Date
시행일자
EFFECT.Date
문서번호
FILE. NO
NO
T E R M I N A L
2004. 03. 17
Q C
결 작 성 검 토
WRIT`N CHK`D
재
공 정 도
PRODUCT&PROCESS CHART (TERMINAL)
=============================
2004. 03. 17
Q - P - 001
공정명
PROCESS
NAME
01
원자재 입고
INCOMING
MATERIAL
02
수입 검사
INCOMING
INSPECTION
03
PRESS
04
공정 및
최종검사
Process&
Final Test
05
포 장
PACKAGE
06
보 관
STORAGE
07
출하 검사
OUTGOING
TEST
작성일자 : 2004. 03. 17
D A T E
흐름도
부공정
주공정
SUB PROCESS MAIN PROCESS
: 2004. 03. 17
사용설비
및 장비
EQUIPMENT
PRESS
작성부서 : 품질관리실
D E P T .: QUALITY CONTROL
공 정 관
리 (MGT OF PROCESS)
항
목
I T E M
관리기준
MGT.RULE
: 서 홍 엽
WRITTEN BY : MR.H Y SEO
A S.H.Y B.J.S S.S.S
P
R` 03/17 03/17 03/17
D
검 사 관 리 (MGT OF INSPECTION)
검사항목
ITEM
겉모양(Shape)
치수(Dimension)
도금두께
(Coating Thickness)
유압 OIL량(Oil Pressure)
작업표준 물성(Certificates
AIR 공급량(Air Pressure)
STD OF WORK of Propertied)
납땜성
원재료 및 간지 풀림(Winding)
(Solderability)
수량 CHECK SENSOR(Counter Sensor)
겉모양(Shape)
금형 이상 유무(State of press Tool)
치수(Dimension)
타발유 도포(Oil Injection)
형합성(Matching)
OIL 냉각장치(Oil Cooler)
저울,SEALING기 수량(Quantity)
Digital Scale 포장상태(State of Package)
Packer
V/C,공구현미경
V/C,TOOL M/S
작 성 자
승 인
APR`D
검사방식
METHOD
판정기준
JUDGEMENT
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
관련표준
STANDARDIZE
YSI-101-004
YSI-091-005
체크검사
CHECK
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
포장관리규칙
Package
Regulation
YSI-102-002
YSP-152
겉모양(Shape) 체크검사(CHECK) 출하검사 규격
치수(Dimension) 계수조정형샘플링 STD OF OUTGOING
형합성(Matching) MIL-STD-105D
TEST
YSI-102-100
제정일자
ESTA. Date
개정일자
REV. Date
시행일자
EFFECT.Date
문서번호
FILE. NO
NO
W A F E R
A S S ` Y
Q C
공 정 도
PRODUCT&PROCESS CHART (WAFER ASS`Y)
=============================
2004. 03. 17
2004. 03. 17
Q - A - 001
공정명
PROCESS
NAME
01
도금핀 입고
INCOMING
Plated Pin
02
수입 검사
INCOMING
Inspection
03
조 립
ASS'Y
04
공정 및
최종검사
PROCESS &
FINAL TEST
05
포 장
PACKAGE
06
보 관
STORAGE
07
출하검사
OUTGOING
TEST
작성일자 : 2004. 03. 17
작성부서 : 품질관리실
D A T E : 2004. 03. 17
D E P T .: QUALITY CONTROL
흐름도
부공정
주공정
SUB PROCESS MAIN PROCESS
사용설비
및 장비
EQUIPMENT
공 정 관
리 (MGT OF PROCESS)
항
목
I T E M
관리기준
MGT.RULE
작 성 자
결 작 성 검 토
WRIT`N CHK`D
재
: 서 홍 엽
WRITTEN BY : MR.H Y SEO
검사방식
METHOD
납땜조(Solder Port)
겉모양(Shape)
체크검사
도금두께측정기
납땜성
(CHECK)
(Coating Thickness
(Solderability)
Gauge), V/C
도금두께
조립기(ASS'Y M/C) PIN이송(State of Pin carried) 작업표준 (Coating Thickness
WAFER 이송(State of Wafer carried) STD OF WORK 치수(Dimension)
PIN휨(Pin Camber)
공구현미경,V/C SENSOR 동작(Sensor function)
전수검사
겉모양(Shape)
(Tool M/C),V/C PIN DETECTOR 동작상태
치수(Dimension) (Test of Total
Push Pull Gage
CHECK)
(Pin Detector Function)
납땜성
통전기
체크검사
(Solderability)
(Short Checker)
(CHECK)
PIN유지력
수량(Quantity)
포장관리규칙 (Pin retention)
저울(Digital
포장상태(State of Package)
Package
Scale)
Regulation
Sealing기(Packer)
납땜조(Solder Port)
P.P.Gage, V/C
mΩ/㏁ meter
내전압 시험기
(Puncture Tester)
A S.H.Y B.J.S S.S.S
P
R` 03/17 03/17 03/17
D
검 사 관 리 (MGT OF INSPECTION)
검사항목
ITEM
승 인
APR`D
판정기준
JUDGEMENT
수입검사 규격
STD OF INCOMING
INSPECTION
관련표준
STANDARDIZE
YSI-101-005
YSI-091-006
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
겉모양(Shape) 체크검사(CHECK) 출하검사 규격
치수(Dimension) 계수조정형샘플링 STD OF OUTGOING
TEST
형합성(Matching) MIL-STD-105D
납땜성
(Solderability)
PIN 유지력
(Pin retention)
YSI-102-003
YSP-152
YSI-102-100