INDUSTRIAL POWER SUPPLY Worldwide Electric Motors Wiring Diagram A. Frames 143T through 184T are 9-Lead, 208-230/460 Volt, Wye wound. B. Frames 213T through 256T are 9-Lead, 208-230/460 Volt, Delta wound. C. Frames 284T through 447T and 505UZ are 12-Lead, 208-230/460 Volt, Wye/Delta wound. D. Frames 449T and 586/7 are 6-Lead, 460 Volt, Wye-Delta wound. E. Please see wiring terminal samples provided below. 9-Lead, 208-230/460 Volt YY 9-Lead, 208-230/460 Volt Y Low Voltage ΔΔ High Voltage Δ Low Voltage High Voltage 4 5 6 4 5 6 6 4 5 4 5 6 7 8 9 7 8 9 7 8 9 7 8 9 1 2 3 1 2 3 1 2 3 1 2 3 L1 L2 L1 L3 L2 L3 L1 12-Lead, 208-230/460 Volt 5 4 5 6 6 4 5 7 8 9 7 8 9 1 2 3 12 10 11 12 10 11 1 2 3 1 2 3 L3 L1 L2 L1 L2 L3 L3 Corporate Headquarters: TEMCo - Tower Electric Motor Company Inside USA: International: (877) 474-8209 L3 High Voltage 4 L2 L2 Δ High Voltage 6 L1 L1 L3 6-Lead, 460 Volt Δ ΔΔ Low Voltage L2 (510) 490-2187 41484 Christy Street Fax: (510) 490-1507 Fremont, CA 94538 www.temcoindustrialpower.com esentative.