Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au CONTENTS FOR ALL ENQUIRIES CONTACT US Contents Page No. Ordering Procedure For Metal Door Frames 3 Metal Door Frame Information Fixing Details and Handing. 4 Metal Door Frame Information & Terminology 5 Additional Extra’s Hinges, Frame Fixings, Welding, Non Standard Sizes, Etc 6 Non Rated Metal Door Frames 7 Fire Rated Metal Door Frames 8 Fire Door Ordering Procedure 9 Fire Door Installation Guide & Important Information 10 Fire Rated Doors, Mini 35mm Thick 11 Fire Rated Doors, Maxi 45mm Thick 12 Fire Door Additional Extra’s, Special Provisions, Vision Panels, Door Grilles 13 Non Rated Doors , Metal Cladding & Perimeter Seals 14 Fire Door Hardware, Door Locks, Door Closers, Head Latches, Etc 15 Fire Door Upgrade Seals 16 Fire Rated Access Panels, for walls & ceilings 17 Access Panels (Non Fire Rated) & Lift Motor Room Hatches 18 Sliding Fire doors 19 Fire Rated Windows 20 Warranty 21 Terms & Conditions of Sale 22 Company Details 23 Inglis 24 QBSA Licence Number 1162186 ABN - 96 132 923 669 Head Office Australian Architectural Fire Doors Pty Ltd 29 Andrew Campbell Drive. Narangba, Qld. 4054 Phone: 07 3888 5911 Fax: 07 3888 4619 E-mail: [email protected] Web: www.aafd.com.au Gold Coast Office 5 / 6 John Duncan Court, Varsity Lakes, Queensland 4277 Phone: 07 5593 6668 Fax: 07 5593 8898 Page 2 Australian Architectural Fire Doors Pty Ltd ORDERING PROCEDURE FRAMES Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au ORDERING PROCEDURE - METAL DOOR FRAMES 1 Profile E.g. 110mm,brick you would select a frame with a throat size = 114mm for wrap around 140mm block work, you would select a 145mm throat size 190mm block work, you would select a 193mm throat size 2 Fixing Method Please When ordering frames for partition stud walls, you must allow for the stud thickness and plasterboard thickness. Note: A stud wall with 10mm plasterboard either side and a 70mm stud would E.g. give you a wall thickness of 90mm - You would select our N93 profile which has a throat size of 93mm. New masonry walls = Wire ties E.g. Existing masonry walls = Diabolo fixings Stud walls = stud clips, strap fixings or Counter sunk holes. When ordering stud clips you must specify plasterboard thickness, Fire rated frames strap fixing only. 3 Rebate Size The rebate size is determined by the door thickness, E.g. 35mm thick door = 41mm rebate 40mm thick door = 47mm rebate Standard rebate sizes are, 41mm, 47mm & 51mm 4 Reveal Height = Door height + clearance gaps and allow for floor finish thickness Reveal Sizes Reveal Width = Door width + 4mm clearance gaps, double doors allow 6mm Standard Reveal heights are : Non rated frames - 2065mm : Fire rated frames - 2055mm E.g. Reveal Height = 2040mm door + 25mm for door clearances = Standard 2065mm reveal, Reveal Width = 820mm door + 4mm for door clearances = 824mm reveal Frame reveal = 2065 x 824mm 5 Handing When determining the door handing of a door frame, pull the door open towards you and which ever side the hinges are on is the handing. Hinge Type Specify - Quantity, Type, Finish or prep only hinges by others If unsure, refer to page 4 for diagrams of handing. 6 Frames are supplied standard with 2 x Zinc Plated 2.5mm Butt screw fixed hinges. External doors, solid core doors & steel doors generally have 3 hinges or even more depending on size and weight of the door. 7 Assembly Method Metal door frames can be supplied in 3 options: Option 1 - Knockdown form - Slot and lugged mechanically jointed for on site assembly. Option 2 - Welded, Dressed & Primed - Factory Welding, Dress and shop primed with grey zinc phosphate primer or grey etch primer for galvabond frames. Option 3 - Saw Mitred - Assembly and weld, dress & Priming by others. 8 Order Reference Details 1 - Order number 2 - Contact name 3 - Phone number 4 - Transport details 5 - Delivery address 6 - Date required Australian Architectural Fire Doors Pty Ltd Page 3 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 INFORMATION FOR ALL ENQUIRIES CONTACT US POPULAR FIXING METHODS FOR MASONRY/CONCRETE WALLS Face Fix Tilt Panel - Cast in Wrap Around Dyna Fix POPULAR FIXING METHODS FOR STUD WALLS Stud Clips Standard Strap Fixings Fire Rated Strap Fixings New Generation SPECIFICATIONS FOR KNOCKDOWN METAL DOOR FRAMES Material: Frames manufacture from 1.1mm zinc anneal, FM frames 1.4mm Standard Heights: Non rated frames 2065 and Fire rated frames 2055 Standard Widths Singles: 624 / 724 / 774 / 824 / 874 / 924 Standard Widths Doubles: 1246 / 1446 / 1646 Hinges: 2 100 x 75 x 2.5mm zinc plated screw fixed hinges, FM frames 2 100 x 100 x 2.5mm Lock Prep: Standard striker preparation @ standard height -1042mm Fixings: Wire ties fixings for new masonry walls Packing: Individually wrapped and strapped onto timber skids, for ease of transportation Labeling: Numbered, Bar-coded or branded upon request. Stud clip HANDINGS LEFT HAND DOUBLE DOORS RIGHT HAND DOUBLE ACTION Page 4 Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 INFORMATION FOR ALL ENQUIRIES CONTACT US DOOR FRAME INDUSTRY TERMINOLOGY REVEAL WIDTH HEAD 285MM 1780MM REVEAL HEIGHT H I N G E S T I L E L O C K S T I L E 1040MM O/ALL HEIGHT LOCK HEIGHT STD = 1042MM 300MM STANDARD HINGE AND LOCK POSITIONS FOR NON RATED FRAMES O/ALL WIDTH DOOR STOP: VAIRES REBATE SIZE: 41, 47 OR 51mm REBATE DOOR STOP Non rated = 15mm HEIGHT Fire rated = 25mm ARCHITRAVE: 38mm SECOND RETURN: 9 -11mm RETURN: 12mm THROAT SIZE: VARIES Australian Architectural Fire Doors Pty Ltd Page 5 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au EXTRA'S FOR ALL ENQUIRIES CONTACT US LOCK PROVISIONS & FRAME FIXINGS - Standard lock preparation at non Standard height - Stud Clips - Additional standard lock preparation - 10mm Dyna Bolt provisions - Non standard lock preparations - Strap Fixings - 10 x per frame - Electric striker preparation - 5 or 10mm counter sunk holes-10 x per frame - Universal Stainless Steel Striker Plate with screws - Wire Ties, Large or Small SPECIAL PROVISIONS AND MISCELLANEOUS ITEMS - Split frames - Reinforce for Bommer Hinges / PVC Doors - Per prep - Fill in back of frames – Per LM - Removable Mullion or Transom - Reed switch provisions - Non standard reveal widths, KD frames only- Add to next size up - Fill in back of frame with plasterboard - 25 - 50mm stop to head of frames, for lift off hinges - Raking frames - Sets 2100 x 1000mm Stop section 25mm stop build ups - Hinge Bolts - Per prep - Stick on rubber buffers - Colours available: Grey Black or Clear - Extended stop for sliding door frames - Pull through rubber buffers -Grey only - Cut down knockdown stiles - Striker & hinge service sections SPECIAL PACKING CHARGES - UPON REQUEST - Welded frames on pallets - per frame - Knockdown frames (Bottom & side protection) - Per frame - Minimum charge - Minimum charge DELIVERY Brisbane Metro Area Gold Coast Sunshine Coast All other areas No discount is to be deducted from delivery rates EXTRA'S - ADDITIONAL HINGES & HINGE PREPARATIONS - KNOCKDOWN FRAMES - Replaces standard 2 x zinc plated screw fixed hinges - HINGES SUPPLIED LOOSE - SCREWS SUPPLIED LOOSE - DOOR CLOSER PROVISIONS - WELD, DRESS AND PRIMING - ETCH PRIMING OF GALVABOND FRAMES PROJECT PROFILE D E A F C B Allowable Variances A = 38mm Only B = 13 to 25mm C = 15 to 40mm D = 41 to 51mm Only E = 16 or 25mm Only F = 11mm Only If dimensions are outside the allowable variances, please refer to sales staff for correct pricing. Page 6 Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au NON RATED FRAMES FOR ALL ENQUIRIES CONTACT US STANDARD SIZES AND PROFILES Non standard height & widths , refer project profile page: 6 * Denotes - Only available with 3 x screw fixed hinge Preparations - Zinc plated hinges included. 47 42 47 15 Singles: 2065 x 624 / 724 / 774 / 824 / 874 / 924 NM114 38 12 Doubles: 2065 x 1246 / 1446 / 1646 38 114 N86 Singles: 2065 x 624 / 724 / 774 / 824 / 874 / 924 15 15 Doubles: 2065 x 1246 / 1446 / 1646 38 N93 38 9 12 145 12 NM194* & N102 47 38 9 9 12 124 47 41 35 41 NM145 12 NM145* & N93 15 9 86 12 47 38 9 9 15 38 15 38 12 75 47 41 15 9 9 24 41 NM114* & N86 15 93 12 41 44 41 Singles: 2065 x 624 / 724 / 774 / 824 / 874 / 924 15 15 NM194 38 38 15 15 N102 38 9 9 12 Doubles: 2065 x 1246 / 1446 / 1646 194 9 9 12 12 102 SD93 & N114 117 38 12 138 Singles: 2055 x 690 / 740 / 790 Singles: 2055 x 840 / 890 / 990 SD93 38 93 Singles: 2055 x 840 / 890 / 990 N114 38 12 114 41 42 N145 38 12 41 145 12 N7610 & N194 15Singles: 2065 x 624 / 724 / 774 / 824 / 874 / 924 Doubles: 2065 x 1246 / 1446 / 1646 N7610 38 9 9 12 15 50 15 15 38 9 9 41 87 41 Singles: 2055 x 690 / 740 / 790 15 15 12 SD114 & N145 41 54 41 114 12 12 38 9 9 9 9 12 SD114 38 38 41 136 41 15 15 50 N194 38 38 37 12 11 76 11 12 12 194 12 Quantity Discounts apply for stock orders: Qty: 20 - 39 Deduct 5% Qty: 40 + Deduct 10% Note: For discount to apply, all frames must be of same profile and on one purchase order, sizes may vary. Australian Architectural Fire Doors Pty Ltd Page 7 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FIRE RATED FRAMES FOR ALL ENQUIRIES CONTACT US STANDARD SIZES AND PROFILES 41 56 41 25 25 F114 Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 F114 38 38 9 9 114 12 Non standard height & widths , refer project profile page: 6 12 41 68 41 To suit 35mm thick fire doors 25 25 F126* - Available with 3 screw fix hinges only Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 F126 38 9 9 12 38 126 Non standard height & widths , refer project profile page: 6 12 41 87 41 To suit 35mm thick fire doors 25 25 F145 Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 F145 38 145 12 41 136 41 To suit 35mm thick fire doors Non standard height & widths , refer project profile page: 6 9 9 12 38 F193 25 25 F193 38 12 38 12 51 36 FM114* - Available with 3 screw fix hinges only 25 25 FM114 38 12 38 114 51 25 25 FM145 38 38 145 FM145* - Available with 3 screw fix hinges only Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 Doubles: 2055 x 1246 / 1446 / 1646 9 9 Doubles: 2055 x 1246 / 1446 / 1646 Non standard height & widths , refer project profile page: 6 12 67 51 Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 To suit 45mm thick fire doors 9 9 12 To suit 35mm thick fire doors Non standard height & widths , refer project profile page: 6 193 51 Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 To suit 45mm thick fire doors 12 Non standard height & widths , refer project profile page: 6 51 115 51 25 25 FM193* - Available with 3 screw fix hinges only FM193 38 38 Singles: 2055 x 624 / 724 / 774 / 824 / 874 / 924 Doubles: 2055 x 1246 / 1446 / 1646 12 193 12 Non standard height & widths , refer project profile page: 6 * Denotes - Only available with 3 x screw fixed hinge Preparations - Zinc plated hinges included. Page 8 Australian Architectural Fire Doors Pty Ltd ORDERING PROCEDURE DOORS FOR ALL ENQUIRIES CONTACT US Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Before we can commence with the manufacture of your fire doors, we will require the following information. Note: We recommend, that all door openings are site measured prior to ordering. 1 Door Sizes Height & Width, Reveal sizes less clearances - Generally less 4mm from reveal width and less 7mm from reveal height Note: From finish floor height (top of floor). 2 Door thickness 35mm Thick = Mini or 45mm Thick = Maxi Note : If doors are to be metal clad add 5mm to finish thickness Double doors only 45mm and are supplied with aluminium meeting stiles 3 Hour Rating 1, 2, 3 or 4 Hour Fire Rating Note: 35mm thick doors are generally for unit Residential Buildings – 1 to 2 hours only 45mm thick doors are generally for Commercial Buildings – 1 to 4 hours only 4 Internal or external. Specify if door will be internal or external 5 Door Finish MDF, PLY, Special Veneer or Metal Clad 6 Special Reinforcing All fire doors are manufactured with reinforcement plates to accept lock, closer & 3 x hinges in standard positions. If alternative or additional hardware is to be fitted, please specify as this will ensure that when installing fire doors, all hardware has correct fixing provisions. Refer page 11 for exploded view of fire door 7 Order Reference Details 1 - Order number 2 - Contact name 3 - Phone Number 4 - Transport details 5 - Delivery address 6 - Date required Special note: All door hardware fitted to E-Plus fire doors, must be tested and approved. If you are not certain that the door hardware you are fitting to the E Core fire door is tested and approved, please contact our sales team on Ph: 07 3888 5911 Australian Architectural Fire Doors Pty Ltd Page 9 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FIRE DOOR INSTALLATION GUIDE FOR ALL ENQUIRIES CONTACT US BCA (Building Code of Australia) requires that all Fire Doors, be installed in accordance with the Australian Standard AS/NZS 1905.1.2005 It is also a requirement in Queensland that a BSA licensed person or company installs and certifies fire door sets Refer below for key points to ensure that doors are installed correctly: * Fire rated door frames must be installed to tested prototype specifications. * The sill of the opening shall be of concrete or other non-combustible material. * Clearances between door and frame at the head and the stiles are to be generally no more than 3mm. The clearance between the finished floor level to the bottom of the door should not exceed 10mm. If it is not practical to adhere to these tolerances please refer to your representative before proceeding. * All door hardware (locks, closers etc.) fitted to fire doors must be tested and approved. If in doubt check with your A.A.F.D. representative. * A maximum of 6mm can be trimmed from all edges. If more is required a special sized door should be ordered. * Special attention should be taken to ensure that door is hung the correct way. E Core fire doors contain reinforcing plates specially prepared within the door to accept hinges, lock and door closer. The doors are stamped at the top hinge stile with the words “top hinge” and the fire rating of the door. * We recommend the use of 35mm x 4.91mm (10# gauge) self tapping screws for fixing the closer and the hinges to the door leaf. A pilot hole of 4mm (5/32”) must be prepared in the door prior to screws being fastened. * When using knob handles with approved locksets a minimum 127mm back set is required. * On completion of installation, all fire door sets must have prescribed metal tags affixed & certified to AS 1905.1 2005, Certification is not included in the sale price of fire doors. * If you require anymore information or are unsure on any of the above matters, please do not hesitate to contact our sales team on 07 3888 5911, or refer to our website :aafd.com.au Please note: These are minimum recommendations only for side hung hinged doors. For further information on special doors e.g. Sliding Fire Doors, Two Way Swing Doors etc, please contact our sales team on (07) 3888 5911. Failure to comply with the above, may result in the fire door being non-compliant and therefore certification can not be issued, warranty may also be void. Important Information: State Legislation , Building Regulations and Occupational Health and Safety Regulations require building owners to maintain the fire doors in their buildings in good operating condition. Australian Standard AS1851:2005, sets out the minimum requirements for the regular maintenance of fire doors. * Inspection Programs, Every 6 or 12 months from date of certification by a licensed QBSA company or individual. AS 1851.2005 stipulates that the fire doors must be regularly inspected and the log book & schedule of evidence must be kept up to date and that prior to the commencement of each inspection the owner or occupier shall furnish the inspector with the log book / schedule of evidence. The building owner has a duty of care to ensure that the lives of the building occupants and the property within the building is protected. Failure to maintain safety equipment is a breach of duty of care and the law in Queensland. Australian Architectural Fire Doors - Door Inspection and Maintenance Service can assist building owners meet the requirements of the various regulations. Page 10 Australian Architectural Fire Doors Pty Ltd FIRE DOOR MINI Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FOR ALL ENQUIRIES CONTACT US MINI 35MM THICK FIRE DOORS Stock Doors 2040 x 820 2040 x 870 2040 x 920 MDF 1 Hr YES YES YES PLY 1 Hr YES YES YES PLY 2 Hr YES YES YES Special Sizes up to 2045 x 820 2100 x 920 2100 x 1200 2400 x 920 2350 x 1200 MDF 1 Hr yes yes yes yes yes PLY 1 Hr yes yes yes N/A N/A PLY 2 Hr yes yes yes yes yes Note: BCA (Building Code of Australia) requires that all Fire Doors, be installed, tagged and certified in accordance with the Australian Standard AS/NZS 1905.1.2005 Typical exploded view of a E-Core door leaf 1. Fire Rated core 2. Lock reinforcing plate 3. Closer reinforcing plate 4. Hinge reinforcing plate 5. Plywood 6. Timber edge strip Australian Architectural Fire Doors Pty Ltd Page 11 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FIRE DOOR MAXI FOR ALL ENQUIRIES CONTACT US MAXI 45MM THICK FIRE DOORS Stock Doors 2040 x 820 2040 x 870 MDF 1 Hr YES YES PLY 1 Hr YES YES PLY 2 Hr YES YES PLY 3 Hr YES YES PLY 4 Hr YES YES Special Sizes up to 2045 x 820 2100 x 920 2100 x 1200 2400 x 920 2400 x 1200 2700 x 920 2700 x 1200 3000 x 1200 3000 x 1500 3500 x 1200 MDF 1 Hr YES YES YES YES YES YES YES YES YES YES PLY 1 Hr YES YES YES YES YES YES YES YES YES YES PLY 2 Hr YES YES YES YES YES YES YES YES YES YES PLY 3 Hr YES YES YES YES YES YES YES YES YES YES PLY 4 Hr YES YES YES YES YES YES YES YES YES YES Note: BCA (Building Code of Australia) requires that all Fire Doors, be installed and certified in accordance with the Australian Standard AS/NZS 1905.1.2005 Double Fire Door Aluminium Meeting Stiles (supply only) For use with 45 mm thick fire doors only T-Bar Meeting Stiles Page 12 T-Bar set 2135mm T-Bar set 2440mm T-Bar set 3050mm T-bar set 3500mm Double Action Bull nose set 2135mm Double Action Bull nose set 2440mm Bull nose Meeting Stiles Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FIRE DOOR EXTRA'S FOR ALL ENQUIRIES CONTACT US Optional Extra's & Provisions for Fire Doors Additional reinforcing provision for: Locks, EMHOD, Hinges, Seals, Panic Bar & Closers Intumescent Air Grills 2 hour rated sizes: 450 x 450mm & 300 x 600mm Vision panels 1 - 4 hours Robax Glass : 300 x 200mm 450 x 120mm 600 x 100mm Extra over, to fit Grills & Vision Panels to Metal Faced doors Conduit through door for electric lock Semi or Fully Concealed Bottom Door Seals Double Action fire doors 2 hour Moulded Panel Fire Doors Special Veneers Bolection Moulds Optional Extra's & Provisions for Fire Doors Intumescent Air Grill Kits: 2 hour rated sizes: 450 x 450mm & 300 x 600mm Vision panels Kits: 1 - 4 hours Fire Rated Glass : 300 x 200mm 450 x 120mm Lorient Intumescent 600 x 100mm Mastic LVH44 Intumescent air transfer Intumescent Door Air Grille Cover grille Intumescent Door Air Grille Cover Plate BOLECTION MOULDS FOR FIRE DOORS DUO REEF LOMBOK TIDE SPADE LILLIE BOLECTION MOULDS PRICE ON APPLICATION Additional Extras for NON RATED DOORS Rebating - Pair of doors Rounded Meeting Stiles - Pair of doors Door grille cut out Glass cut out - includes beading 6.38mm Clear Laminate Glass - Supply and factory fit Groove bottom of door for seal Semi rebate bottom of door for seal External Meranti / Pine Edge Strips - 2 x sides External Meranti / Pine Edge Strips - 4 x sides ALL OTHER SIZES, THICKNESSES AND FINISHES PLEASE CONTACT US Australian Architectural Fire Doors Pty Ltd Page 13 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 SOLID CORE DOORS , METAL CLADDING & SEALS HMR SOLID PARTICLEBOARD CORE MDF FACED WITH 25MM INTERNAL RAILS OR ABOND PLY FACES WITH PINE BLOCKBOARD CORE DOOR Special Sizes up to 35 mm YES YES YES YES YES YES YES NO NO 2040 X 820 2100 x 900 2100 x 1200 2400 x 900 2400 x 1200 2700 x 900 2700 x 1200 3000 x 900 3000 x 1200 40 mm YES YES YES YES YES YES YES YES YES 45 mm YES YES YES YES YES YES YES YES YES Optional - Metal Cladding - Doors sheeted both faces & capped all edges Special Sizes up to 1.1 mm Zinc Anneal 1.2 Galva bond 0.55 Colorbond 2100 x 900 YES YES YES 2100 x 1200 YES YES YES 2400 x 900 YES YES YES 2400 x 1200 YES YES YES 2700 x 900 YES YES YES 2700 x 1200 YES YES YES 3000 x 900 YES YES YES 3000 x 1200 YES YES YES SEALS LE1212 (12 x 12mm) & LE1515 (15 x 15mm) Batwing Seals - (Per L/M, Supplied loose) Standard Sizes: 1000mm, 2100mm, 2400mm, 2700mm & 3000mm Colours available: Black, White, Brown & Grey - Up to 4 Hr Fire Rating IS7060SI Aluminium Astragal Seal (Per L/M, Supplied loose) Used on rebated or unrebated pairs of doors - Finish Silver Anodized Aluminium - Non Fire Rated IS8090SI Heavy duty automatic bottom seal Size: 820mm (Cuts back to 610mm) Size: 920mm (Cuts back to 610mm) - Up to 4 Hr Fire Rating IS8100SI Heavy duty automatic bottom seal fully mortised Size: 820mm (Cuts back to 610mm) Size: 920mm (Cuts back to 610mm) - Up to 4 Hr Fire Rating 12 15 LE1212 Batwing Self Adhesive LE1515 Batwing Self Adhesive IS8100SI Aluminium Bottom seal IS7025SI Aluminium Page 14 IS7060SI Aluminium Astragal seal IS8090SI Aluminium Bottom seal Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 FIRE RATED HARDWARE FOR ALL ENQUIRIES CONTACT US Locks - 1 to 2 Hr Fire Rating Fire Rated Lever Set Lockset—SC Entrance Lever set Lockset - SC Storeroom Lever set Lockset - SC Classroom Lever set Lockset - SC Storeroom Double Lever set Lockset - SC Entrance Knob set Lockset - SC Storeroom Knob set Lockset - SC Classroom knob set Lockset - SC Double Storeroom knob set Fire Rated Knob Set Door Closers Fire Rated Closer - 1 to 3 strength - 1 to 2 Hr Fire Rating Closer - 2 to 4 strength - 1 to 2 Hr Fire Rating Closer - 1 to 6 strength - 1 to 4 Hr Fire Rating Fire Rated Closer Miscellaneous Strike Shield - Stainless Steel - 1 to 3 Hr Fire Rating Head Latch - with Turn Snib - 1 to 4 Hr Fire Rating Head Latch - Chain Bolt Stainless Steel Sequence Selector - 1 to 2 Hr Fire Rating Sequence selector Door Stops Stainless Steel Lock Shield Head Latch - Chain Bolt Head Latch with Turn Door Stops Miscellaneous Size: 50mm Size: 85mm Size: 100mm Size: 150mm Size: 200mm Size: 300mm Stainless Steel Lettering also available Stainless Steel Numerals Australian Architectural Fire Doors Pty Ltd Page Page 17 15 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au FIRE RATED UPGRADE SEALS FOR ALL ENQUIRIES CONTACT US The Lorient Integrity range of upgrade solutions for fire resistant doors can overcome frustrating and expensive problems for building owners, building contractors and essential service providers alike. In-situ fire resistant doors that would otherwise need new and expensive replacements, can now be salvaged. Intumescent Perimeter Seals HP4002 1000mm Lengths HP400221 2100mm Lengths HP400224 2400mm Lengths 3000mm Lengths HP400230 Colours available: Silver, White or Beige Lorient HP4002 Approved for use on fire doors with excessive clearances 4mm to 7mm, top and sides only Bottom upgrade seals to 20 mm FDBU20-820 820mm Lengths FDBU20-920 920mm Lengths FDBU20-1220 1220mm Lengths Finishes available: Clear Anodized or Bronze Lorient FDBU20 Approved to seal gap sizes up to 20mm maximum Bottom upgrade seals to 60 mm FDBU60-820– 35 FDBU60-915-35 FDBU60-1220-35 FDBU60-820– 45 FDBU60-915-35 FDBU60-1220-35 820mm Lengths - 35mm doors 915mm Lengths-35mm doors 1220mm Lengths-35mm doors 820mm Lengths - 45mm doors 915mm Lengths-45mm doors 1220mm Lengths-45mm doors Lorient FDBU60 Approved to seal gap sizes up to 60mm Approvals ∗ All seals are fully tested to AS1530.4 for up to 2 Hours on fire rated door assemblies ∗ Complies with AS/NZS 1905.1 We can also offer competitive prices on the following seals: Fire, Smoke, Sound and Weather. For further information, please contact our sales staff Page 16 Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au ACCESS PANELS FOR ALL ENQUIRIES CONTACT US FIRE RATED All access panels made to order, sizes specified are up to sizes Hinged - Wall & Ceiling 1 Hour Rated Hinged - Wall & Ceiling 1 Hour Rated 300 x 300mm with setting bead 300 x 300mm with Feather Flanged 400 x 400mm with setting bead 400 x 400mm with Feather Flanged 450 x 450mm with setting bead 450 x 450mm with Feather Flanged 530 x 530mm with setting bead 530 x 530mm with Feather Flanged 600 x 600mm with setting bead 600 x 600mm with Feather Flanged 700 x 700mm with setting bead 700 x 700mm with Feather Flanged Specifications: Supplied with feather edged architrave , flanged architrave or setting bead for flush finish Concealed hinges, Standard Allen key budget lock, can be specially keyed for maximum security Maximum door size: 700 x 700mm Hinged - Wall & Ceiling 2 Hour Rated Tested to Australian Standard: AS 1530.4. FRL: - / 60 / 30 Hinged - Wall & Ceiling 2 Hour Rated 300 x 300mm with setting bead 300 x 300mm with Feather Flanged 400 x 400mm with setting bead 400 x 400mm with Feather Flanged 450 x 450mm with setting bead 450 x 450mm with Feather Flanged 530 x 530mm with setting bead 530 x 530mm with Feather Flanged 600 x 600mm with setting bead 600 x 600mm with Feather Flanged 1000 x 600mm with setting bead 1000 x 600mm with Feather Flanged 1200 x 600mm with setting bead 1200 x 600mm with Feather Flanged Specifications: Supplied with feather edged architrave , flanged architrave or setting bead for flush finish Door panel screw fixed into frame, only option - for 2 hour rated with setting bead. Maximum door size: 2100 x 900mm Screw Fixed - Wall & Ceiling 2 Hour Tested to Australian Standard: As 1530.4. FRL: - / 120 / 30 Screw Fixed - Wall & Ceiling 2 Hour 300 x 300mm with setting bead 300 x 300mm with Feather Flanged 400 x 400mm with setting bead 400 x 400mm with Feather Flanged 450 x 450mm with setting bead 450 x 450mm with Feather Flanged 530 x 530mm with setting bead 530 x 530mm with Feather Flanged 600 x 600mm with setting bead 600 x 600mm with Feather Flanged 1000 x 600mm with setting bead 1000 x 600mm with Feather Flanged 1200 x 600mm with setting bead 1200 x 600mm with Feather Flanged Specifications: Supplied with feather edged architrave , flanged architrave or setting bead for flush finish Door panel screw fixed into frame Maximum door size: 1200 x 600mm Tested to Australian Standard: As 1530.4. FRL: - / 120 / 30 2 Hour Hinged Wall Access Panel Australian Architectural Fire Doors Pty Ltd Page 19 17 Page Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au NON RATED ACCESS PANELS & LIFT MOTOR ROOM HATCHES STANDARD SIZES - NON FIRE RATED Metal / Architrave Metal / Setting Bead 200 x 200mm with Feather Flanged 200 x 200mm with setting bead 300 x 300mm with Feather Flanged 300 x 300mm with setting bead 450 x 450mm with Feather Flanged 450 x 450mm with setting bead 450 x 600mm with Feather Flanged 450 x 600mm with setting bead 550 x 550mm with Feather Flanged 550 x 550mm with setting bead 600 x 600mm with Feather Flanged 600 x 600mm with setting bead 600 x 1200mm with Feather Flanged 600 x 1200mm with setting bead Note: We also supply non-standard sizes All panels: Manufactured from 1.0mm & 1.2mm Zinc seal Steel Each panel individually supplied with key Concealed hinging Horizontal & vertical fixing lugs Finished with grey primer, ready for painting Lift Motor Room Hatches • Approved to AS 1530.4 to two hours. • Complies with work cover regulations. • Tailor made to suit clear opening. • Safety rails for open position. • Easy retrofit application. Description Australian Architectural Fire Doors Lift Motor Room Hatch systems are designed to provide flexibility and strength while also providing a fire rating of up to two hours. Australian Architectural Fire Doors Lift Motor Room Hatches consist of a steel frame supporting a hinged load bearing, steel chequer plate. Safety gates and bar to hold open cover plates are provided. To fire rate the hatch, a ply-faced 75mm E-Core panel (fitted with handles) is laid into steel frame work. Application The Australian Architectural Fire Doors Lift Motor Room Hatch system is suitable for installation in new and existing buildings where access to lift motor is required. Specification Lift motor room hatches shall be fire protected using Australian Architectural Fire Doors fire rated lift motor room hatch system. The system is to be approved to AS 1530.4 and will meet BCA requirements. Installation The Lift Motor Room Hatch system is complete ready to drop into slab with all frame work, gates and rails supplied. It can be ordered up to two meters wide and up to four meters long Pricing / Technical Support Please contact our sales staff for pricing and technical support on this product. Typical Construction Page 18 20 Page Australian Architectural Fire Doors Pty Ltd SLIDING FIRE DOOR FOR ALL ENQUIRIES CONTACT US Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 About the Sliding Fire Door Resistance to spread of fire by compartmentisation of buildings is a long established international practice and appropriate methods are extensively prescribed in Australian Building Regulations. a commitment toward research and development and sensitivity to market demands has resulted in an extensive range of sliding door test approvals and sliding door styles. Sliding fire doors have been approved to AS 1530 Part 4 to suit the maximum Fire Resistance Level requirements of the Australian Building Regulations. AAFD Sliding Fire Doors are designed to be used where maximum opening sizes are required for the movement of plant or equipment, or where the use of conventional side hung doors is impractical due to limited space. The internal Core board construction gives sliding fire doors new slim line and light weight qualities that have never before been seen in such fire door constructions. AAFD Horizontally Sliding Fire Doors are specified for a large range of industrial and commercial buildings. Sliding fire doors are generally specified for applications in factories, warehouses, car parks, shopping complexes, hospitals, schools and institutions. AAFD fire doors are produced from natural and environmentally friendly materials resulting in a one piece Core that is asbestos and mineral fibre free. Sliding Doorset Selection An AAFD sliding door system selected for the application at hand is dependent on the size of the opening to be covered and the available side room around the opening. The different sliding door configurations available are listed below: (1) Single Leaf Sliding Doors (2) Bi-Parting Sliding Doors (3) Multiple Leaf sliding Doors (4) Combination Multiple Leaf Bi-Parting Sliding Doors (5) Personnel “Wicket” doors with one or two Access Wicket Doors All sliding doors have counterweight assembly located at the leading or trailing edges. Bi-Parting, Multiple Leaf and Combination doors depending on size may require more than 1 counterweight systems (refer to individual data sheets for further details). Pricing / Technical Support Please contact our sales staff for pricing and technical support on this product. Australian Architectural Fire Doors Pty Ltd Page 21 19 Page Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au FIRE RATED WINDOWS FOR ALL ENQUIRIES CONTACT US Fire rated window systems The Glaze is a 5 mm thick clear glass that is used for fire and smoke protection of windows in buildings. Based on the standard fire resistant test, the Glaze can retain integrity for more than 240 minutes to temperatures up to 1100 degrees Celsius, therefore effectively stopping fire and smoke spreading, enabling occupants enough time to evacuate the building. It also offers protection for fire fighters carrying out search and rescue and fire fighting operations. Some of the benefits of using fire rated glass include: • Locally cut to size • Fire rated up to 4 hours to Australian Standards • • • • Low thermal expansion Can be upgraded to a safety glass Simple steel framing system Low cost compared to other fire rated glass and toughened glass Provides up to 4 hours FRL to Australian Standard AS 1530 Part 4 (-/240/-) and meets the deemed-to-satisfy provisions of Building Code of Australia (BCA96). Applications Fire rated window systems can be used to provide fire and smoke protection for windows requiring fire resistance and a clear view. It is approved for use in masonry and plasterboard wall applications. At the end of test - 4 Hours Typical Frame Profile Safety Classification The Glaze can be upgraded to a safety classification of Grade A to conform to AS/NZS 2208:1996 for safety glazing materials in buildings meeting DTS provisions of BCA96 for glazed assemblies. This provides increased protection from flying glass and better protection from windstorms and blasts. Other benefits include blocking of harmful UV light, reduction in glare and fading of interior furnishings and it also deters smash and grab burglaries. Maintenance The Glaze fire-rated glass and window systems should be inspected routinely to ensure there are no cracks, foreign materials such as stickers, notices, etc affixed to the glass or frame and the frame is not under any undue stress. Pricing / Technical Support Please contact our sales staff for pricing and technical support on this product. Page Page 2022 Australian Architectural Fire Doors Pty Ltd Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 WARRANTY METAL DOOR FRAME WARRANTY All frames supplied by Australian Architectural Fire Doors( AAFD), shall be supplied upon the following terms and conditions that are to be read in conjunction with AAFD’s standard terms and conditions. No subsequent order, contract, correspondence or communication will vary these Terms & Conditions unless such variations are acknowledged in writing by Australian Architectural Fire Doors . Australian Architectural Fire Doors Warrants: 1. Those goods specified in the Schedule, for a period of one (1) year as from the date of transfer of risk, to be free from defects in material and workmanship which would render them unserviceable or unfit for normal use or for any use specified by the purchaser as a condition of its order prior to manufacture. 2. To the extent permitted by the law or the express provision of any statute or otherwise hereby expressly excluded and in respect warranties that cannot be so excluded, these terms and conditions shall be read such that those statutory warranties are read as being in additional to the warranties hereby given. 3. Subject to Clause 2, the warranty in Clause 1 shall be read subject to the following matters being excluded as defects: 3.1 frames not accorded reasonable treatment by the customer. 3.2 damage or defects arising out of, or in connection with, shipment or storage after frames leave the control of Australian Architectural Fire Doors Queensland (i.e. delivered to site or handed over to a carrier). Frames must be inspected by the customer for visible defects immediately upon delivery. 3.3 Claims for non conforming deliveries (incomplete defective or incorrectly supplied) will only be considered if made within 3 working days of receipt or delivery of frames. All delivery checks are the responsibility of the customer 3.4 Under NO Circumstance will AAFD be liable if frames are installed before checking that they are supplied correctly and free from defects. 3.5 Factory priming is only to protect frames in transport and general handling it is the responsibility of the customer to immediately on delivery of all frames apply 2 coats of Compatible sealing priming to ensure corrosion or the like does not occur. 3.6 It is the responsibility of the builder to ensure that the frames are installed plumb and square and suitably anchored using fixing plates or fixing clips where provided. 3.7 The storage and security of frames either in a storage area or storage facility is the responsibility of the builder. 3.8 Stainless steel hinges are required to be maintained every 2 months to ensure prevention of tarnishing and corrosion. If not carried out warranty will not be DOOR WARRANTY All doors supplied by AAFD, shall be supplied upon the following terms and conditions that are to be read in conjunction with AAFD's standard terms and conditions. No subsequent order, contract, correspondence or communication will vary these Terms & Conditions unless such variations are acknowledged in writing by AAFD. 1.0 Those goods specified in the Schedule, for a period of one (1) year as from the date of transfer of risk, to be free from defects in material and workmanship which would render them unserviceable or unfit for normal use or for any use specified by the purchaser as a condition of its order prior to manufacture. 2.0 To the extent permitted by the law or the express provision of any statute or otherwise hereby expressly excluded and in respect warranties that cannot be so excluded, these terms and conditions shall be read such that those statutory warranties are read as being in additional to the warranties hereby given. 3.0 Subject to Clause 2, the warranty in Clause 1 shall be read subject to the following matters being Excluded as Defects: 3.1 Variations in geometry of doors, unless not in accordance with AS26881984 for squareness and flatness. 3.2 Natural variations in the colour and texture of timber. 3.3 Variations in veneered plywood finishes, unless not in accordance with AS2270-1979 or AS2271-1979 3.4 Normal show through of internal and core components (Note: it is not recommended to use high gloss finishes on doors where reflected light may exaggerate show through.) 3.5 Doors not accorded reasonable treatment by the customer, including failure by customer to store flat or hang in dry buildings including moist or freshly plastered areas where the moisture content of the door skins and door components may increase abnormally and cause warping. 3.6 Failure by the customer to ensure that the doors: A. Immediately after fitting and prior to hanging (including top and bottom edges) have received two (2) coats of paint, varnish or sealer so as to prevent absorption of moisture and damage to doors. B. Have been painted with a preparation suitable to eliminate damage caused by exposure to natural or induced elements. C. Have received proper exterior finishes for exterior doors and depending on the degree of exposure and additional protection by flashing and weather-stripping on the top and bottom edges. D. Where doors are exposed to direct sunlight the door surface has been finished with light reflective colours. E. Claims for non conforming deliveries (incomplete defective or incorrectly supplied) will only be considered if made within 3 working days of receipt or delivery of doors. All delivery checks are the responsibility of the customer F. Under NO Circumstance will Australian Architectural Fire Doors be liable if doors are installed before checking that doors are supplied correctly and free from defects. 3.7 Experience has demonstrated that when warp occurs after delivery, it is usually due to improper storage or adverse moisture conditions prior to or after hanging, not due to faulty manufacture. Australian Architectural Fire Doors will accept no responsibility for The development of warp if: A. The moisture content of the door falls below 12% or exceeds 18% B. Doors with face veneers of differing materials or timber species C. Doors that are improperly installed or which do not swing freely D. External doors painted with dark colours E. Doors installed in air conditioned areas or with abnormal temperature differentials from one face to the other F. Doors that have been leant against walls prior to hanging G. Doors that are fitted with bolection mouldings that have been installed by others or differ from the tested prototype H. Doors installed in frame out of square or untrue I. Wedging of doors 3.8 Australian Architectural Fire Doors does not extend any guarantee against warping for 35 & 40mm thick doors which are greater in height than 2100mm or wider than 900mm. 3.9 Due to moisture characteristics of M.D.F. it is recommended that the additional care be taken in the storage and handling of these doors to prevent moisture damage to the face of the M.D.F., or warping. The doors should be stored flat on at least three timbers in a dry room. 4.0 Whilst our price may include external edge strips, this type of door construction has inherent issues beyond the control of the manufacturer i.e. cracking at the edge strip. For this reason, should cracking occur AAFD will not be held responsible. 4.1 Damage or defects arising out of or in connection with the shipment or storage, after doors leave the control of Australian Architectural Fire Doors (i.e. delivered to site or handed over to the carrier). Doors must be inspected by the customer for visible defects immediately upon transfer of risk. 4.2 Fire doors must be installed in accordance with AS1905.1-1997., and maintained in accordance with AS1851.7-1994. 4.3 Unless otherwise indicated all fire doors are supplied un-primed. No allowance made for signage with the BSA Page D-27 Amendment D2.23 for fire doors. 4.4 Australian Architectural Fire Doors does not accept responsibility for the protection of doors nor will AAFD be responsible for the protection of doors once installed into frames. 4.5 Door installations are to be signed of using the Australian Architectural Fire Doors QA door installation sign off sheet as completed and accepted. Returning to an installation will constitute a variation. GENERAL PRODUCTS WARRANTY All Products supplied by Australian Architectural Fire Doors Queensland, shall be supplied upon the following terms and conditions that are to be read in conjunction with AAFD's standard terms and conditions. No subsequent order, contract, correspondence or communication will vary these Terms & Conditions unless such variations are acknowledged in writing by Australian Architectural Fire Doors. 1.0 To the extent permitted by the law or the express provision of any statute or otherwise hereby expressly excluded and in respect warranties that cannot be so excluded, these terms and conditions shall be read such that those statutory warranties are read as being in additional to the warranties hereby given. 2.0 Subject to Clause 2, the warranty in Clause 1 shall be read subject to the following matters being excluded as defects: 2.1 Products not accorded reasonable treatment by the customer. 2.2 Damage or defects arising out of, or in connection with, shipment or storage after Goods leave the control of Australian Architectural Fire Doors Queensland (i.e. delivered to site or handed over to a carrier). Goods must be inspected by the customer for visible defects immediately upon delivery. 2.3 Claims for non conforming deliveries (incomplete defective or incorrectly supplied) will only be considered if made within 3 working days of receipt or delivery of frames. All delivery checks are the responsibility of the customer 2.4 Under NO Circumstance will Australian Architectural Fire Doors be liable if goods are installed before checking that they are supplied correctly and free from defects. Australian Architectural Fire Doors Pty Ltd Page Page2321 Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 Web: www.aafd.com.au TERMS & CONDITIONS OF SALE 1.General 1.1 All goods supplied by Australian Architectural Fire Doors 29 Andrew Campbell Drive Narangba Qld 4504, shall be supplied upon the following terms and conditions. 1.2 No subsequent order or correspondence or communication will vary these Terms and Conditions unless such variations are acknowledged in writing by Australian Architectural Fire Doors. 2.Interpretation 2.1 For the purpose of these Terms and Conditions: Supplier – means Australian Architectural Fire Doors, 29 Andrew Campbell Drive Narangba Qld 4504 Purchaser - means any person, firm or corporation who requests the supply of goods by the supplier. Warp, Twist, or Show Through - means any allowable warp, twist or show through for timber doors as defined in the relevant Australian Standard. Moisture Content - means any allowable variation as defined in the relevant Australian Standard for timber door sets. Goods - means any frame, door or other item supplied by the supplier. 3.Orders 3.1 Subject to clause 3.2 a contract according to these Terms and Conditions shall be created upon receipt by the Supplier of an oral, written or facsimile order from the Purchaser. 3.2 The Supplier may in its absolute discretion refuse to supply goods where:(a) Goods are unavailable for any reason. (b) An order has not been received by the Supplier. (c) No satisfactory credit arrangements have been reached. (d) The Supplier has refused credit to the Purchaser. (e) The Purchaser has unpaid accounts owing to the Supplier. (f) Agreed credit limits have been reached. 3.3 No cancellation of an order for the supply of goods may be made unless agreed to in writing by Australian Architectural Fire Doors. Any incurred costs resulting from a cancellation are the responsibility of the purchaser. 3.4 It is the absolute responsibility of the Purchaser to ensure all working documents and specifications are correct at no charge to the Supplier. The Supplier shall be entitled to rely on any instruction from the Purchaser. 4.Australian Standards 4.1 All goods and services supplied by the Supplier shall comply with all relevant Australian Standards. 4.2 The builder is to ensure that all frames doors, passive products or any product installed by purchaser, conform to Australian Standards when installed on site. 5.Warranties and Exclusions 5.1 All expressly implied conditions and warranties representation are expressly negatived save for those:(a) In the Terms and Conditions (b) Implied under the Law of New South Wales or the provisions of Division 2 of Part V of the Trade Practices Act 1974. 5.2 The Supplier expressly excludes any responsibility or liability for any defect in goods including their appearance where: (a) There is a loss or gain in the moisture content outside acceptable limits due to the goods not being immediately sealed upon receipt by the Purchaser pursuant to Clause 7.6 or not being stored horizontally in dry conditions undercover or any condition outside the suppliers authority. 5.3 The Supplier shall not be liable for any damage, expense or cost due to the non delivery of goods, or delay in their delivery or in their installation caused by: (a) The Purchaser not fulfilling their obligations pursuant to these Terms and Conditions. (b) Weather (c) Industrial action (d) Unavailability of raw materials (e) Any matter beyond the Supplier’s control (f) Refusal of reasonable access to the Supplier and their contractors to any site. (g) Incorrect working documentation supplied by the Purchaser (h) Painted or varnished doors or frames replaced by Warrantee are to be repainted or varnished by the purchaser. 5.4 Back Charges cannot exceed the cost of material to the affected area. 6.Risk / Property 6.1 Risk in goods shall pass to Purchaser immediately upon delivery. 6.2 Notwithstanding the passing of risk, property in the goods delivered shall not pass to the purchaser until all amounts payable by the Purchaser under any order have been paid. 6.3 Where goods are delivered by Supplier to the Purchaser or delivered and hung by the Supplier or its subcontractors without payment of the price in full to the Supplier the Purchaser shall: (a) Hold the goods on trust for Supplier until all amounts owed by the Purchaser to Supplier have been paid in full. (b) Be deemed to have irrevocably appointed the Supplier its lawful attorney to do all acts necessary to ensure the retention if title to goods to the Supplier including the registration of any charge pursuant to the Corporation Law. 7.Delivery 7.1 Purchaser shall give the supplier at least 14 working days notice of the date for delivery. 7.2 Delivery of good shall be at the Suppliers premises during normal business hours. 7.3 Where Purchaser requires delivery of goods to be on site the Purchaser Page 22 24 Page 7.4 Delivery of goods on site shall be on vehicle on a properly constructed roadway along or as close as possible to the job site as conditions allow in the absolute discretion of the Supplier or its subcontractors. 7.5 The Purchaser shall be responsible for the unloading of goods. In the event the Purchaser is not available at the job site the Supplier has the right to unload to goods and shall not be responsible for any damage or expense. 7.6 The Purchaser shall immediately upon delivery store the goods in a horizontal position in a dry area under cover and shall as soon as practicable seal the top and bottom of doors to maintain the acceptable moisture content limits. 7.7 A quantity, description, date time and place of delivery of goods as indicated on the Supplier’s invoice or delivery docket shall be conclusive evidence of the quantity, description, date, time and place of delivery of goods. 8.Installation 8.1 Where the purchaser requests the Supplier to install the goods Purchaser shall give the Supplier a minimum of fourteen working days notice of such request and shall identify the site for installation. 8.2 The Supplier may in its absolute discretion appoint or engage any subcontractor to perform any obligation to the Supplier to install or deliver goods or any other requirements of these Terms and Conditions. 8.3 The Purchaser shall provide at its own expense full and complete access to the site for installation and safe working conditions to the Supplier and its subcontractors. 8.4 All installation quoted allows for hardware to be installed at time of hanging of the doors unless qualified otherwise in our tender. 9. Price / Payment 9.1 The Supplier shall not be under any obligation to certify the goods as complying with any applicable safety standard:(a) Unless the final contract value including any variations have been agreed in writing by the Supplier and the Purchaser and paid in full to the Supplier. (b) Until the Purchaser has done all ancillary matters such as painting and carpeting in the absolute discretion of the Supplier to enable the Supplier to provide such certification. (c) Unless the Purchaser has paid all outstanding monies payable to the Supplier arising from whatever source. 9.2 The Purchaser shall not at any time be entitled to retain any money owing to the Supplier for whatever reason including allegedly defective goods or installation of goods. 9.3 The Purchaser shall comply with any credit terms imposed by the Supplier otherwise all goods and installation of goods shall be paid in full prior to delivery. 9.4 Credit Payment Terms: 7 days after end of month. 9.5 We the tendered reserve our right to negotiate an equitable adjustment to the terms and conditions applicable to this contract (or order) and to the prices under which the goods and services are to be provided if there is imposed on Australian Architectural Fire Doors Pty Ltd or its input costs the burden of any taxation change in the form of a consumption tax, new wholesale tax or similar which is not to be fully reimbursed to Australian Architectural Fire Doors Pty Ltd. Upon receipt of variations advice reserves Australian Architectural Fire Doors , the right to charge an investigation & design fee. Australian Architectural Fire Doors reserves the right to negotiate an equitable adjustment to the terms and conditions applicable to this tender and to the prices under which the work is to be executed/services offered or product supplied. If there is imposed on Australian Architectural Fire Doors, whether directly or indirectly, the burden of any taxation change and, in particular, by way of a goods and services tax, consumption tax or similar (“GST”). The proposed adjustment sought will apply is not fully reimbursed, fully off-set or otherwise fully recouped by Australian Architectural Fire Doors from current activities. 10.Default by Purchaser 10.1 In the event that Purchaser: (a) Breaches their Terms and Conditions (b) Fails to pay any monies owing to the Suppliers (c) Becomes or threatens to become or is in jeopardy of being insolvent, bankrupt or wound up, as the case may be (d) Ceases or threatens to cease business the Supplier may in absolute discretion without prejudice to any of its other rights (e) Refuse delivery or installation of goods (f) Repossess any goods delivered by the Purchaser (g) Retain all monies paid on account by the Purchaser 10.2 Where the Purchaser breached any Terms and Conditions of this contract the Supplier reserves the right to re-sell the goods. Exclusions: The following items are excluded unless specifically noted to the contrary within the body of our tender submission. Door, frame and installation sets noted below have not been allowed for: - Roller Shutter. - Joinery Doors. - Vertical movement of doors etc. - Distribution on site of frames (frames will be delivered to one drop off point). - Installation of frames or grouting fire frames. - Reed Switch, electric strike or other electrical devices. - Electrical connections. - Hoisting facilities by others. Australian Architectural Fire Doors Pty Ltd Company Details FOR ALL ENQUIRIES CONTACT US Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 QBSA Licence Number 1162186 ABN - 96 132 923 669 Head Office Australian Architectural Fire Doors 29 Andrew Campbell Drive. Narangba, Qld. 4054 Phone: 07 3888 5911 Fax: 07 3888 4619 E-mail: [email protected] Web: www.aafd.com.au Gold Coast Office Australian Architectural Fire Doors 5 / 6 John Duncan Court, Varsity Lakes, Queensland 4277 Phone: 07 5593 6668 Fax: 07 5593 8898 E-mail: [email protected] Australian Architectural Fire Doors Pty Ltd Page 2523 Page INGLIS FIRE & SAFETY Australian Architectural Fire Doors 29 Andrew Campbell Drive, Narangba. 4054. Ph: 07 3888 5911 Fax: 07 3888 4619 INGLIS FIRE & SAFETY PTY LTD ABN: 68 125 870 831 INGLIS FIRE & SAFETY Pty Ltd For all replacement, repairs and inspection of door Head Office: 29 Andrew Campbell Drive. Narangba, Qld. 4504.4013 Email: [email protected] Web: www.inglisfireandsafety.com.au Phone: (07) 3888 591 Fax: (07) 3888 4619 QBSA Licence Number 1142980 FIRE DOOR REPLACEMENT AND REPAIRS Direct from the manufacturer Cost effective solutions Queensland owned Quality Service Guaranteed Obligation free quotes Speedy response BSA Licensed certification Security Doors
© Copyright 2026 Paperzz