WWW.ANITE.COM/NEMO BTS FILE FORMAT VERSION 1.15 DOCUMENT NUMBER NNNNNNNNN ISSUE N © Anite 2014 BTS FILE FORMAT Copyright The information contained in this document is confidential and no part of it may be copied or reproduced in any form without the written consent of Anite Network Testing. Additionally, this document is not to be passed to or discussed with third parties without the prior written permission of Anite Network Testing. Anite’s products are subject to continual development and specifications may change. Users of Anite’s products and documentation should exercise their own independent judgement to evaluate the suitability of Anite’s products and documentation for their particular use. Anite does not accept any liability arising from the application or use of the product or this documentation. All reasonable care has been made to ensure that this document is accurate. If you have any comments on this document, or would like details of any Anite products, services or equipment, please contact us through the Anite website. Page 2 BTS FILE FORMAT CONTENTS 1 GENERAL STRUCTURE ...................................................................................... 5 2 CREATING BTS FILES ....................................................................................... 6 3 PARAMETERS .................................................................................................. 7 3.1 Mandatory cell parameters ........................................................................ 7 3.2 Optional cell parameters ........................................................................... 7 3.3 AMPS cell parameters ............................................................................... 9 3.3.1 Mandatory parameters ...................................................................... 9 3.3.2 Optional parameters ......................................................................... 9 3.3.3 Cell search method .......................................................................... 10 3.4 GSM cell parameters ................................................................................ 11 3.4.1 Mandatory parameters ..................................................................... 11 3.4.2 Optional parameters ........................................................................ 11 3.4.3 Cell search method .......................................................................... 12 3.5 CDMA cell parameters .............................................................................. 13 3.5.1 Mandatory parameters ..................................................................... 13 3.5.2 Optional parameters ........................................................................ 13 3.5.3 Cell search method .......................................................................... 14 3.6 UMTS cell parameters .............................................................................. 15 3.6.1 Mandatory parameters with 28-bit cell ID ........................................... 15 3.6.2 Mandatory parameters with 16-bit cell ID and RNC ID .......................... 15 3.6.3 Optional parameters ........................................................................ 16 3.6.4 Cell search method .......................................................................... 17 3.7 TETRA cell parameters ............................................................................. 17 3.7.1 Mandatory parameters ..................................................................... 17 3.7.2 Optional parameters ........................................................................ 17 3.7.3 Cell search method .......................................................................... 18 3.8 TD-SCDMA cell parameters ....................................................................... 18 3.8.1 Mandatory parameters ..................................................................... 18 3.8.2 Optional parameters ........................................................................ 19 3.8.3 Cell search method .......................................................................... 19 3.9 WIMAX cell parameters ............................................................................ 20 3.9.1 Mandatory parameters ..................................................................... 20 3.9.2 Optional parameters ........................................................................ 20 3.9.3 Cell search method .......................................................................... 21 3.10 EVDO cell parameters .............................................................................. 22 3.10.1 Mandatory parameters ..................................................................... 22 3.10.2 Optional parameters ........................................................................ 22 3.10.3 Cell search method .......................................................................... 23 Page 3 BTS FILE FORMAT 3.11 LTE cell parameters ................................................................................. 24 3.11.1 Mandatory parameters ..................................................................... 24 3.11.2 Optional parameters ........................................................................ 24 3.11.3 Cell search method .......................................................................... 25 3.12 IDEN cell parameters ............................................................................... 26 3.12.1 Mandatory parameters ..................................................................... 26 3.12.2 Optional parameters ........................................................................ 26 3.12.3 Cell search method .......................................................................... 26 4 TECHNICAL SUPPORT ...................................................................................... 27 4.1 User Club ............................................................................................... 27 4.2 Nemo Support Portal ............................................................................... 27 4.3 Phone and Email Support ......................................................................... 27 Page 4 BTS FILE FORMAT 1 GENERAL STRUCTURE The first row of the file contains the keywords that define the order of the parameters in the following lines. Keywords are separated with semicolon (;) or tabulator character. Other rows in the file contain the cell definitions. Each line describes one cell and contains a set of parameters describing the cell as well as the site in which the cell resides. For both site and cell information, there are both mandatory parameters and optional parameters. Site and cell parameters are separated with semicolon or tabulator character. The file format supports three data types: integer, float and string. Integer type is defined as a numeric value without dot character. Float type is defined as a numeric value with dot character. String type is defined as a set of any printable ASCII characters except semicolon. Page 5 BTS FILE FORMAT 2 CREATING BTS FILES BTS files can be created, for example, with MS Excel. Type in the cell parameters and save the file in CSV format. After you have saved the as CSV, please check with Notepad (or with similar ASCII text editor) that your delimiter is either semicolon or tabulator. Also check that your coordinates have the period (.) character, for example 65.012345. Finally, change the file extension to .nbf. Page 6 BTS FILE FORMAT 3 PARAMETERS 3.1 Mandatory cell parameters Parameter Keyword Type Description System SYSTEM String AMPS, GSM, TDMA, CDMA, UMTS, TETRA, TD-SCDMA, WIMAX, EVDO or LTE. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Latitude LAT Float Latitude of the site in degrees. Longitude LON Float Longitude of the site in degrees. Decimal degrees (DD) express latitude and longitude geographic coordinates as decimal fractions and are used in many Geographic Information Systems (GIS), web mapping applications such as Google Maps, and GPS devices. Decimal degrees are an alternative to using degrees, minutes, and seconds (DMS). As with latitude and longitude, the values are bounded by ±90° and ±180° each. Positive latitudes are north of the equator, negative latitudes are south of the equator. Positive longitudes are east of Prime Meridian, negative longitudes are west of the Prime Meridian. Latitude and longitude are usually expressed in that sequence, latitude before longitude. 3.2 Optional cell parameters Note that BSIC number format and separator parameters are defined per BTS file, not per cell. If these two parameters are included in the BTS file, they must be located at the beginning of the file on separate rows. See example below. Page 7 Parameter Keyword Type Description Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Antenna Identification ANTENNA_ID String Text BTS FILE FORMAT BSIC Number Format BSIC_NUMBER_FORMAT Integer Base Station Identity Code Format. Valid values are: "OCT", "DEC", and "HEX", Case is insensitive. If this keyword is not specified, “DEC” is used by default Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL, REPEATER, SMALL_CELL, or DAS Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. Separator SEPARATOR String SEPARATOR can be specified by the SEPARATOR keyword. If this keyword is not specified, either ; or TAB character is used by default and it is determined from the parameter header line User-defined column name User-defined name String Text Example: BSIC_NUMBER_FORMAT “OCT” SEPARATOR “;” SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;LAC;DIR;NCELL_1;NCELL_2;NCELL_3 GSM;Site Name 1;65.066053;25.458366;Cell Name 1;64;77;12500;65231;0;NEMO1;NEMO2;NEMO3 GSM;Site Name 1;65.066053;25.458366;Cell Name 2;41;42;12501;5231;90;NEMO5;NEMO6;NEMO7 GSM;Site Name 1;65.066053;25.458366;Cell Name 3;2;24;12502; 65231;45;NEMO8;NEMO9;NEMO10 Page 8 BTS FILE FORMAT 3.3 AMPS cell parameters 3.3.1 Mandatory parameters 3.3.2 Parameter Keyword Type Description System SYSTEM String AMPS. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Channel Number CH Integer Channel number SAT SAT Integer Setup Audio Tone Antenna Direction DIR Integer Values range from 0 to 360 degrees. Optional parameters Parameter Keyword Type Description Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;CH;SAT;CID;DIR AMPS;Site Name 1;65.066053;25.458366;Cell Name 1;140;1;11503;45 AMPS;Site Name 1;65.066053;25.458366;Cell Name 2;410;2;11501;90 AMPS;Site Name 1;65.066053;25.458366;Cell Name 3;201;3;11504;230 Page 9 BTS FILE FORMAT 3.3.3 Cell search method Lines are drawn from the current location on a map to the serving cell based on the following algorithm: Matching Channel + SAT Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 10 BTS FILE FORMAT 3.4 GSM cell parameters 3.4.1 Mandatory parameters 3.4.2 Page 11 Parameter Keyword Type Description System SYSTEM String GSM. Site Name SITE String Name of the site. Cell Name CELL String Unique identifier of the cell. If unique name for every cell is not available, concatenation of LAC and CI can be used. Channel Number CH Integer ARFCN. Values range from 0 to 1024. BSIC BSIC Integer Base Station Identity Code in decimal format. Values range from 0 to 63. If BSIC Number Format is octal or hex, values with octal range from 0 to 77. With hex values range from 0 to 3F. Cell ID CID Integer Cell identification. Values range from 0 to 65535. LAC LAC Integer Location Area Code. Values range from 0 to 65535. Antenna Direction DIR Integer Values range from 0 to 360 degrees. Optional parameters Parameter Keyword Type Description RAC RAC Integer Routing Area Code. Values range from 0 to 255. Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text BTS FILE FORMAT Example: BSIC_NUMBER_FORMAT "OCT" SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;LAC;DIR;NCELL_1;NCELL_2;NCELL_3 GSM;Site Name 1;65.066053;25.458366;Cell Name 1;64;1;12500;65231;0;NEMO1;NEMO2;NEMO3 GSM;Site Name 1;65.066053;25.458366;Cell Name 2;41;1;12501; 65231;90;NEMO5;NEMO6;NEMO7 GSM;Site Name 1;65.066053;25.458366;Cell Name 3;2;1;12502; 65231;45;NEMO8;NEMO9;NEMO10 3.4.3 Cell search method Lines are drawn from the current location on a map to the serving cell and neighbor cells based on the following algorithm. Matching CellId + LAC Matching CellId + BCCH Matching BCCH Channel + BSIC (also for neighbor list and missing neighbors) Matching BCCH Channel (also for neighbor list and missing neighbors) Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 12 BTS FILE FORMAT 3.5 CDMA cell parameters 3.5.1 Mandatory parameters 3.5.2 Parameter Keyword Type Description System SYSTEM String CDMA. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Pilot Number PN Integer Values range from 0 to 10000. Channel CH Integer Channel Antenna Direction DIR Integer Values range from 0 to 360 degrees. Optional parameters Parameter Keyword Type Description System ID SID Integer System ID. SID presents international identification and system number identifying the service area and frequency block. Network ID NID Integer Network ID. Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;PN;CH;DIR CDMA;Site Name 1;65.066053;25.458366;Cell Name 1;171;150;90 CDMA;Site Name 1;65.066053;25.458366;Cell Name 2;272;150;55 Page 13 BTS FILE FORMAT 3.5.3 Cell search method Lines are drawn from the current location on a map to the active set and neighbor set cells based on the following algorithm. Matching Channel + Pilot Matching Pilot Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 14 BTS FILE FORMAT 3.6 UMTS cell parameters 3.6.1 Mandatory parameters with 28-bit cell ID Parameter Keyword Type Description System SYSTEM String UMTS. Site Name SITE String Name of the site. Cell Name CELL String Unique identifier of the cell. If unique name for every cell is not available, 28-bit cell ID can be used. Channel Number CH Integer UARFCN. Value ranges: UMTS 850, from 43574458,1007,1012,1032,1037,1062,1087 UMTS 900, from 2935-3090 UMTS 1900, from 96629938,412,437,462,487,512,537,562,587,612,637,662,687 UMTS 2100, from 10550 to 10850. UMTS 2100 AWS, from 15351740,1887,1912,1937,1962,1987,2012,2037,2062,2087 Scrambling Code SCR Integer Values range from 0 to 512. Cell ID CID Integer Cell ID. The 28-bit Cell Identity (“UC-Id” in 3GPP) is a Concatenation of RNC-ID and C-ID. Antenna Direction 3.6.2 DIR Integer Values range from 0 to 360. Mandatory parameters with 16-bit cell ID and RNC ID Parameter Keyword Type Description System SYSTEM String UMTS. Site Name SITE String Name of the site. Cell Name CELL String Unique identifier of the cell. If unique name for every cell is not available, 28-bit cell ID can be used. Channel Number CH Integer UARFCN. Value ranges: UMTS 850, from 43574458,1007,1012,1032,1037,1062,1087 UMTS 900, from 2935-3090 UMTS 1900, from 96629938,412,437,462,487,512,537,562,587,612,637,662,687 UMTS 2100, from 10550 to 10850. UMTS 2100 AWS, from 15351740,1887,1912,1937,1962,1987,2012,2037,2062,2087 Page 15 BTS FILE FORMAT Scrambling Code SCR Integer Values range from 0 to 512. Cell ID CID_16 Integer Cell ID. The 16-bit Cell Identity. C-ID. RNC ID RNCID Integer RNC ID. The 12- bit RNC identity. Cell-ID (28 bit) = RNCID (12 bit) + CI (16 bit). Antenna Direction DIR Integer Values range from 0 to 360. Note that cell ID must be given either in 28-bit (CID) or 16-bit format (CID_16) combined with 12-bit RNC ID (RNCID). 3.6.3 Optional parameters Parameter Keyword Type Description LAC LAC Integer Location Area Code. Values range from 0 to 65535. RAC RAC Integer Routing Area Code. Values range from 0 to 255. URA URA Integer UTRAN Registration Area RNC ID RNCID Integer Radio Network Controller ID. Equal to the 12-bit RNCId in 3GPP TS 25.401, section 6.1.5. Integer, base 10 or (with prefix 0x) hexadecimal representation. Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example with 28-bit cell ID: SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;SCR;DIR;NCELL_1;NCELL_2;NCELL_3 UMTS;Site Name 1;65.066053;25.458366;Cell Name 1;10838;;123811;96;0;NEMO1;NEMO2;NEMO3 UMTS;Site Name 1;65.066053;25.458366;Cell Name 2;10838;;123758;2;0;NEMO4;NEMO5;NEMO6 UMTS;Site Name 1;65.056053;25.458366;Cell Name 3;10838;;123769;4;90;NEMO7;NEMO8;NEMO9 Page 16 BTS FILE FORMAT Example with 16-bit cell ID: SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID_16;RNC_ID;SCR;DIR;NCELL_1;NCELL_2;NCELL_3 UMTS;Site Name 1;65.066053;25.458366;Cell Name 1;10838;;58275;1;96;0;NEMO1;NEMO2;NEMO3 UMTS;Site Name 1;65.066053;25.458366;Cell Name 2;10838;;58222;1;2;0;NEMO4;NEMO5;NEMO6 UMTS;Site Name 1;65.056053;25.458366;Cell Name 3;10838;;58233;1;4;90;NEMO7;NEMO8;NEMO9 3.6.4 Cell search method Lines are drawn from the current location on a map to the active set and monitored set cells based on the following algorithm. Matching Cell ID Matching Carrier + SCR (also for neighbor list and missing neighbors) Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). 3.7 TETRA cell parameters 3.7.1 Mandatory parameters 3.7.2 Page 17 Parameter Keyword Type Description System SYSTEM String TETRA. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. LAC LAC Integer Location Area Code. Values range from 0 to 16383. Main Carrier CH Integer Values range from 0 to 4095. Frequency Band BAND Integer Values range from 0 to 15. Antenna Direction DIR Integer Values range from 0 to 360. Optional parameters Parameter Keyword Type Description Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. BTS FILE FORMAT Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;LAC;CH;BAND;DIR TETRA;Site Name 1;65.066053;25.458366;Cell Name 1;3652;124;3;90 TETRA;Site Name 1;65.066053;25.458366;Cell Name 2;3613;125;3;45 TETRA;Site Name 1;65.056053;25.458366;Cell Name 3;3622;68;3;0 3.7.3 Cell search method Lines are drawn from the current location on a map to the serving cell and neighbor cells based on the following algorithm. Matching Channel + LAC + Band Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). 3.8 TD-SCDMA cell parameters 3.8.1 Mandatory parameters Page 18 Parameter Keyword Type Description System SYSTEM String TDSCDMA or TD-SCDMA. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Channel Number CH Integer Values range from 9504 to 10121. Cell Parameters Id CPID Integer Values range from 0 to 127. Cell ID CID Integer Cell ID (16- bit) Antenna Direction DIR Integer Values range from 0 to 360. BTS FILE FORMAT 3.8.2 Optional parameters Parameter Keyword Type Description LAC LAC Integer Location Area Code. Values range from 0 to 65535. RAC RAC Integer Routing Area Code. Values range from 0 to 255. URA URA Integer UTRAN Registration Area RNC ID RNCID Integer Radio Network Controller ID Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;CPID;DIR TDSCDMA;Site Name 1;65.066053;25.458366;Cell Name 1;10120;;;96;0 TDSCDMA;Site Name 1;65.066053;25.458366;Cell Name 2;10120;;;2;30 TDSCDMA;Site Name 1;65.056053;25.458366;Cell Name 3;10120;;;4;90 3.8.3 Cell search method Lines are drawn from the current location on a map to the active set and monitored set cells based on the following algorithm. Matching Cell ID (16 bit) Matching Carrier + Cell Parameters Id (also for neighbor list) Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 19 BTS FILE FORMAT 3.9 3.9.1 3.9.2 WIMAX cell parameters Mandatory parameters Parameter Keyword Type Description System SYSTEM String WIMAX. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Frequency FREQ Float Frequency in MHz. Preamble Index PI Integer Values range from 0 to 113. Antenna Direction DIR Integer Values range from 0 to 360. Base Station ID BSID String Base Station ID. Six colon separated hex values in double quotes. Optional parameters Parameter Keyword Type Description Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;FREQ;PI;DIR;BSID WIMAX;Site Name 1;65.066053;25.458366;Cell Name 1;2550.000;67;90;03:0f:21:00:02:72 WIMAX;Site Name 1;65.066053;25.458366;Cell Name 2;2550.000;68;180;03:0f:21:00:02:73 WIMAX;Site Name 1;65.056053;25.458366;Cell Name 3;2550.000;69;270; 03:0f:21:00:02:74 Page 20 BTS FILE FORMAT 3.9.3 Cell search method Lines are drawn from the current location on a map to the serving cell and neighbor cells based on the following algorithm. Base Station ID + Preamble index Frequency + Preamble index Note that if multiple matching cells are found, closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 21 BTS FILE FORMAT 3.10 EVDO cell parameters 3.10.1 Mandatory parameters Parameter Keyword Type Description System SYSTEM String EVDO. Site Name SITE String Name of the site. Cell Name CELL String Name of the cell. Pilot Number PN Integer Values range from 0 to 10000. Channel CH Integer Channel Antenna Direction DIR Integer Values range from 0 to 360 degrees. 3.10.2 Optional parameters Parameter Keyword Type Description System ID SID Integer System ID. SID presents international identification and system number identifying the service area and frequency block. Network ID NID Integer Network ID. Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text Example: SYSTEM;SITE;LAT;LON;CELL;PN;CH;DIR EVDO;Site Name 1;65.066053;25.458366;Cell Name 1;171;150;90 EVDO;Site Name 1;65.066053;25.458366;Cell Name 2;272;150;55 Page 22 BTS FILE FORMAT 3.10.3 Cell search method Lines are drawn from the current location on a map to the active set and neighbor set cells based on the following algorithm. Matching Channel + Pilot Matching Pilot Note that if multiple matching cells are found, the closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 23 BTS FILE FORMAT 3.11 LTE cell parameters 3.11.1 Mandatory parameters Parameter Keyword Type Description System SYSTEM String LTE Site Name SITE String Name of the site. Cell Name CELL String Unique identifier of the cell. If there is no unique name available for every cell, Cell ID (CID) can be used Channel Number CH Integer EARFCN number. Values range from 0 to 65535 Cell ID CID Integer Cell identification Cell identification of the current cell. Range: 0 – 268435455 Physical Layer Cell ID PCI Integer Values range from 0 to 503. Antenna Direction DIR Integer Values range from 0 to 360. 3.11.2 Optional parameters Page 24 Parameter Keyword Type Description TAC TAC Integer Tracking area code Tracking area code of the currently used cell. See 3GPP TS 124.301 subclause 9.9.3.32. Range: 0 – 65535 Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text BTS FILE FORMAT Example: SYSTEM;SITE;LAT;LON;CELL;CH;CID;PCI;DIR;NCELL_1;NCELL_2;NCELL_3 LTE;Site Name 1;65.066053;25.458366;Cell Name 1;65535;26842545;96;0;NEMO1;NEMO2;NEMO3 LTE;Site Name 1;65.066053;25.458366;Cell Name 2;65535;26841545;2;0;NEMO4;NEMO5;NEMO6 LTE;Site Name 1;65.056053;25.458366;Cell Name 3;65535;26844545;4;90;NEMO7;NEMO8;NEMO9 3.11.3 Cell search method Lines are drawn from the current location on a map to the active set and monitored set cells based on the following algorithm. Cell Identification (Cell ID) (for serving cell) Matching Channel number + Physical Layer Cell ID (for both serving and neighbor cells) Page 25 BTS FILE FORMAT 3.12 IDEN cell parameters 3.12.1 Mandatory parameters Parameter Keyword Type Description System SYSTEM String IDEN Site Name SITE String Name of the site. Cell Name CELL String Unique identifier of the cell. If unique name for every cell is not available, concatenation of CH and CC can be used. Channel Number CH Integer Values range from 1 to 1200. Color Code CC Integer Color code Range: 0 – 15 Antenna Direction DIR Integer Values range from 0 to 360 degrees. 3.12.2 Optional parameters Parameter Keyword Type Description Antenna Height HEIGHT Integer Values range from 0 to 1000 Antenna Tilt TILT Float Values range from -90 to 90. Antenna Beam Width BEAM Integer Values range from 1 to 360 Cell Range RANGE Integer Cell range in meters. Cell Type TYPE String NORMAL or REPEATER Neighbor Cell Name NCELL_n String Unique identifier of the neighbor n. User-defined column name Userdefined name String Text 3.12.3 Cell search method Lines are drawn from the current location on a map to the active set and monitored set cells based on the following algorithm. Matching channel number + color code (for both serving and neighbor cells) Note that if multiple matching cells are found, the closest cell is selected. The cell is matched only if distance is less than 50 km (31 miles). Page 26 BTS FILE FORMAT 4 TECHNICAL SUPPORT If you have questions on or beyond this documentation about Nemo tools, please contact our technical support service through Nemo Support Portal at http://nemosupport.anite.com, call us (local phone numbers can be found in chapter Phone and Email Support) or send us an email at [email protected]. Note that for full support you need to have the Maintenance Agreement. 4.1 User Club Nemo User Club offers several new ways to benefit from Nemo products. You can find it from http://nemouserclub.anite.com. Access to the Nemo User Club is restricted to customers with SW maintenance and Technical Support agreements or partner agreements. If you are an existing Anite Network Testing customer with SW maintenance and Technical Support agreements, but you are without access to the User Club, please complete an on-line registration form. After submitting the requested information, you will receive a personal access key and password by email in a few days time. Once you are registered with our User Club, you will automatically receive e-mails informing you each time a new version of software for your Nemo Product is released. It is fast, easy, and it is available to you seven days a week, 24 hours a day. 4.2 Nemo Support Portal Nemo Support Portal is a web interface for technical support, product-related questions, and RMA requests. It offers a fast and convenient way to reach our technical support team and submit repair, warranty repair, and calibration requests. Customers can open a support ticket, follow the status of existing tickets, and request technical support 24/7/365. Furthermore the Nemo Support Portal includes a Knowledge Base for the most frequent and latest topics on Nemo Products. Submitting a ticket via Nemo Support Portal ensures that our technical specialists have all the necessary information available to solve your support case, resulting in faster response times. Please go to http://nemosupport.anite.com to access the portal and click “Request access” to obtain a password to the system. 4.3 Phone and Email Support During the warranty period, the phone support related to potential software errors is free of additional charge. Registered users with a valid Maintenance Agreement are entitled to full support. Nemo Support Portal is the preferred channel for technical support requests, but you can also send us an email. When emailing, please let us know the number of your Software Maintenance and Support Agreement. Page 27 BTS FILE FORMAT Please contact us at the following locations: Global Mobile +358 50 395 7800 Americas Mobile +1 469 951 9105 +1 469 774 4608 (En español e português) APAC Tel. +65 9746 2431 P.R. China Tel. +86 10 6567 8528 India Tel. +91 982 0016372 Middle East Tel. +86 10 6567 8528 P.R. China Tel. Page 28 +97 155 620 4132
© Copyright 2024 Paperzz