Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT DESCRIPTION The Murphco sleeve-flange spun aluminum plumbing vent is shop fabricated in one piece (without joint and solder) with a proven lathe. The main purpose of the sleeve is to assure the waterproofing around a vent pipe or other roof penetrations such as electrical wire exit, etc. The corresponding spun aluminum cap completes the vent waterproofing in a simple application. Model 1500 MATERIALS Aluminum: Series 1100 Sleeve thickness: 0.064" (1.62 mm) Cap thickness: 0.051" (1.29 mm), models 1500 & 1600 Cap thickness: 0.064" (1.62 mm), models 1700 & 1800 COLOR Color: bare aluminum INSTALLATION Sleeve: This type of sleeve is used on roofs covered with B.U.R. asphalt felt and gravel surface membranes, modified bitumen membranes or other prefabricated PVC and EPDM membranes. With the model 1500, the sleeve is designed to cover the vent pipe previously wrapped with mineral wool insulation on a height of 100 mm (4"). The model no. 1500 D is mainly used on private residences and/or when the height is limited. Model 1600, 1700 & 1800 sleeves are fabricated to assure the waterproofing around the circular pipes (plumbing vent) of an exterior diameter from 100 @ 200 mm (4" @ 8"). PAGE 1 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT To seal the sleeve to the membrane, it is recommended to prime the base flange on both faces, with a primer compatible with the membrane materials. Set the base flange of the sleeve into a bed of bituminous cement. Apply a second trowel layer of bituminous cement to seal the superior face of the flange. Flash-in the metal flange with 2 plies of cotton fabric and 1 ply of roofing felt into hot bitumen (B.U.R.).* For modified bitumen membrane, apply a reinforcing ply from the base of the sleeve to 6" out of the edge of the flange then apply the cap sheet continuously. Apply a circular elastomeric caulking joint around the sleeve on the finished membrane. Cap: The cap must be installed to ensure the waterproofing of the free space between the interior vent pipe and the aluminum sleeve. The cap models nos. 1523 & 1524 serve to complete the vent pipe waterproofing with the sleeve model 1500. The model 1523 fits on vents with a diameter of 75 mm (3") and the model 1524 fits on vents with a diameter of 100 mm (4").** The cap model 1550 is a "Chinese hat" shaped to permit the crossing of electric wires. The original cap is perforated of 24 holes of 13 mm (½") diameter each. The hole may be modified on site or made wider in factory request. This cap is built of 2 pieces of aluminum retained in place by 2 metal screws. This cap may also be installed on a spun aluminum sleeve used for dry cleaning exhaust. In this case, the cap is designed to assure the exterior waterproofing as well as evacuating the condensation water outside. This cap is also retained in place by 2 metal screws. The cap models 1624 & 1625 serve to complete the vent pipe waterproofing with the sleeve model 1600; they fit on vents with a diameter of 100 @ 125 mm (4" @ 5").** Teh cap models 1724, 1725 & 1726 serve to complete the vent pipe waterproofing with the sleeve model 1700; they fit on vents with a diameter of 100 @ 150 mm (4" @ 6").** The cap models 1824, 1825, 1826 & 1827 serve to complete the vent pipe waterproofing with the sleeve model 1800; they fit on vents with a diameter of 100 @ 200 mm (4" @ 8").** * Suivre les recommandations du manufacturier de membrane ** Les diamètres des manchons et évents de plomberie sont les valeurs nominales arrondies Révision 03: Aout 2011 PAGE 2 OF 13 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT INSTALLATION (cont’d) Cap (cont’d) Continuous caulking joint All cap models finishing by 05 are plain caps to close permanently the useless pipes. In this case, the spun aluminum sleeve must be full of mineral wool to prevent condensation. Such cap is retained in place with an interior circular caulking joint. Any model of cap may be prepared on request to close permanently all types of sleeves (models 1500, 1600, 1700 & 1800). Prior to cap application, it is recommended to apply a continuous bituminous cement ribbon or a compatible caulking ribbon between the interior surface of the cap and the pipe, in order to prevent the highly probable condensation water to return into the insulated bell-shape sleeve base. When this caulking joint is dry, it retains the cap in place against vandalism. ADVANTAGES ET WARRANTY - Built in one piece; Without fabrication joint; No solder; Sturdy; Economical; Easy and fast to install; Anti-vandalism; Guaranteed against corrosion; Guaranteed against fabrication defects. ** The diameter of sleeves and plumbing vents are nominal rounded values Révision 03: Aout 2011 PAGE 3 OF 13 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT DETAIL MODEL 1500 (All dimensions are in millimeters) Wider bellshape Vent sleeve, model 1500 Vent sleeve, model 1500 D PAGE 4 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT DETAIL MODELS 1600 & 1700 (All dimensions are in millimeters) Vent sleeve, model 1600 Vent sleeve, model 1700 PAGE 5 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT DETAIL MODEL 1800 (All dimensions are in millimeters) Vent sleeve, model 1800 PAGE 6 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT CAP DETAIL MODEL 1500 (All dimensions are in millimeters) Cap, model 1523 Cap, model 1524 Opening Dia. 13 mm (½") Cap, model 1505 Cap, model 1550 PAGE 7 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT CAP DETAIL MODELS 1600 & 1700 (All dimensions are in millimeters) Cap, model 1624 Cap, model 1625 Cap, model 1724 Cap, model 1725 Cap, model 1726 PAGE 8 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT CAP DETAIL MODEL 1800 (All dimensions are in millimeters) Cap, model 1824 Cap, model 1826 Cap, model 1825 Cap, model 1827 PAGE 9 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT TYPICAL DETAIL Scale: 1:5 Cap model 1524 Continuous circular caulking joint Option of Anti-vandalism cap Spun aluminum plumbing vent no. 1500 Insulating wool Bituminous cement Plumbing vent Seal around vent pipe at vapour-barrier level PAGE 10 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT TYPICAL DETAIL (EXTENDED SLEEVE) Scale: 1:5 d = 4″ (100 mm) Extended interior aluminum sleeve (tapered) Continuous circular caulking joint Spun aluminum plumbing vent no 1500 Insulating wool Bituminous cement Plumbing vent Seal around vent pipe at vapour-barrier level When a reroofing project involves the installation of extra insulating thickness, the plumbing vent pipes are too short. Instead of installing a prefab coupling, an extended aluminum sleeve, tapered shape for stable position, may be used as simpler and inexpensive pipe extension. PAGE 11 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT SELECTION TABLE Piece Description Vent pipe diameter* Model Model 1500 Sleeve Sleeve Cap Cap Cap Cap Wider insulated base Uniform Closed Open Open "Chinese hat" 75 @ 125 mm (3" @ 5") 75 @ 125 mm (3" @ 5") non applicable 75 mm (3") 100 mm (4") not applicable 1500 1500 D 1505 1523 1524 1550 Model 1600 Sleeve Cap Cap Cap Wider insulated base Closed Open Open 100 @ 150 mm (4" @ 6") not applicable 100 mm (4") 125 (5") 1600 1605 1624 1625 Model 1700 Sleeve Cap Cap Cap Cap Wider insulated base Closed Open Open Open 100 @ 175 mm (4" @ 7") not applicable 100 mm (4") 125 mm (5") 150 mm (6") 1700 1705 1724 1725 1726 Model 1800 Sleeve Cap Cap Cap Cap Cap Wider insulated base Closed Open Open Open Open 100 @ 200 mm (4" @ 8") not applicable 100 mm (4") 125 mm (5") 150 mm (6") 175 @ 200 mm (7" @ 8") 1800 1805 1824 1825 1826 1827 Extended sleeve Sleeve Cap Wider insulated base Open 100 mm (4") 100 mm (4") or more on request * Nominal rounded values PAGE 12 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc Les Produits MURPHCO Ltée TECHNICAL DATA SPUN ALUMINUM PLUMBING VENT DESIGNED AND MANUFACTURED BY LES PRODUITS MURPHCO LTÉE Technical assistance or further information may be obtained from: Les Produits MURPHCO Ltée 4955 Brock st. Montreal, Quebec, Canada H4E 1B5 Telephone: (514) 937-3275 Fax: (514) 937-6797 E-mail: [email protected] Web: www.toitures.ca DOCUMENTATION PREPARED WITH THE TECHNICAL COOPERATION OF: Roome, Léger & Associés Limitée ROOFING CONSULTANTS 415, avenue Bourke, suite 102 Dorval (Québec) H9S 3W9 Téléphone : (514) 636-9292 Télécopieur : (514) 631-0910 Courriel : [email protected] DISTRIBUTED BY: NOTICE The information and specification provided in this document are applicable at time of publication. They are condensed from the exact results obtained through real tests and field experience, but may not be construed as implying any absolute and final dictate on our part. Les Produits MURPHCO Ltée Reserves the right to modify, without notice, the information provided in the present document, as a result of its research and development policy on its products. PAGE 13 OF 13 Révision 03: Aout 2011 G:\DESSINS\Fiches techniques\Murphco\Manchon pré-moulé\MANCHON PRÉ-MOULÉ.doc
© Copyright 2026 Paperzz