Cross Reference Table for Area Classification Details Equipment Area Focus Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Adjacent Areas Adequately ventilated nonenclosed area adjacent to a classified area Enclosed area with vaportight barriers adjacent to a classified area Enclosed area with non-vaportight barriers adjacent to a classified area and in contact with its Division 1 hazardous influence boundary Enclosed area with non-vaportight barriers adjacent to a classified area and in contact with its Division 2 hazardous influence boundary Figure 2 Figure 3 Figure 4 Figure 5 Bulk Loading or Unloading Drum Filling Station (Outdoors or Indoors in an Adequately Ventilated Building)) Marine Terminal Tank Car or Tank Truck Loading and Unloading Via Closed System Tank Car or Tank Truck Loading and Unloading Via Open System Handling Flammable Liquid Figure 5.9.6 Handling Flammable or Combustible Liquid Product Transfer through Bottom Only for Flammable Liquid Figure 19 Figure 5.9.14 Figure 11 Product Transfer through Dome Only for Flammable Liquid Figure 10 Tank Truck: Figure 5.9.4(d) Tank Car: Figure 5.9.4(c) Tank Car Only: Figure 5.9.4(b) Product Transfer through Bottom Only for Liquefied Gas, Compressed Gas, or Cryogenic Liquid Product Transfer through Dome Only for Flammable Liquefied Gas, Compressed Gas, or Cryogenic Liquid Product Transfer through Top or Bottom for Flammable Liquid Figure 13 Figure 9 Figure 5.9.5 Figure 12 Figure 5.9.4(e) Compressors Compressor Below Grade (Inadequately Ventilated Area) Compressor at Grade (Outdoors) Handling Flammable or Combustible Gas or Vapor or Highly Volatile Liquids (HVL) Figure 101 Handling Flammable or Combustible Gas or Vapor Handling Highly Volatile Liquid (HVL) Figure 51 Page 1 of 10 Figure 93 Figure 5.9.2(a) Cross Reference Table for Area Classification Details (cont.) Equipment Compressor (Inside Adequately Ventilated Compressor Shelter) Compressor (Inside Inadequately Ventilated Compressor Shelter) Compressor (Outdoors but Under Roofed Building without Sides) Compressor (Inside Adequately Ventilated Roofed Building with One or More Sides) Compressor (Inside Inadequately Ventilated Roofed Building with One or More Sides) Compressor (Indoor with Enclosed Operating Equipment) Compressor (Indoor with Open or Semi-Enclosed Operating Equipment) Compressor (Indoor, Walled Off Area, Enclosed Operating Equipment) Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Compressors (cont.) Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Figure 23 Figure 5.9.9(a) Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Figure 25 Figure 5.9.9(b) Handling Flammable or Combustible Gas or Vapor Handling Highly Volatile Liquid (HVL) Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Groups F or G Dust with no visible dust cloud, dust layer less than 1/8 inch and surface color not discernable Groups F or G Dust with no visible dust cloud or dust layer and surface color discernable Group E Dust with moderate or dense dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Groups F or G Dust with moderate or dense dust cloud to no visible dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Group E Dust Figure 52 Page 2 of 10 Figure 52 with Figure 93 Figure 105 Figure 53 Figure 94 Figure 106 Figure 54 Figure 95 Figure 5.8(c) Figure 5.8(d) Figure 5.8(b) Figure 5.8(a) Figure 5.8(f) Cross Reference Table for Area Classification Details (cont.) Equipment Drain System (Enclosed Area) Drain System (Enclosed Area) (cont.) Drain System (Nonenclosed Area) Emergency (Above Grade) Emergency or Temporary (Below Grade) Sump (Adequately Ventilated Enclosed Area) Sump (Inadequately Ventilated Enclosed Area) Sump (Nonenclosed Adequately Ventilated Area) Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Effluent Handling and Treatment Type 1 Open Drain System Figure 58 Type 2 Open Drain System Adequately ventilated Type 3 Open Drain System Type 4 Open Drain System Inside Adequately Ventilated Building handling Cryogenic Flammable Liquids including Natural Gas Type 1 Open Drain System Type 2 Open Drain System Adequately ventilated Type 3 Open Drain System Adequately ventilated Type 4 Open Drain System Handling Cryogenic Flammable Liquids including Natural Gas Impounding Basin Oil-Water Separator handling Flammable Liquid Drainage Ditch Oil-Water Separator handling Flammable Liquid Below grade Open Sump handling Flammable or Combustible Liquid Figure 59 Figure 61 Above Grade Sump inside an enclosure handling Flammable or Combustible Liquid Below Grade Open Sump Inside Open Vault or Containment Area Below grade Open Sump handling Clean Water Below grade Open Sump handling Flammable or Combustible Liquid Below grade Closed Sump or Oily Water Separator with Atmospheric Vent and No Access Hatch(es) Below grade Closed Sump or Oily Water Separator with Vent to Carbon Cannisters and No Access Hatch(es) Page 3 of 10 Figure 63 Figure 5.9.13, Top Detail Figure 58 Figure 59 Figure 60 Figure 62 Figure 5.9.13, Bottom Detail Figure 5.9.7, Top Detail Figure 5.9.7, Bottom Detail Figure 57 with Division 2 for the remainder of the enclosed area Figure 34 Figure 63 Figure 58 Figure 57 Figure 27 – Detail 4 1. Figure 27 Detail 4 but without Vent classification 2. Add Vent note “To Carbon Cannisters” Cross Reference Table for Area Classification Details (cont.) Equipment Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Effluent Handling and Treatment (cont.) Sump (Nonenclosed Adequately Ventilated Area) (cont.) Below grade Closed Sump or Oily Water Separator with Atmospheric Vent and Access Hatch(es) Waste Water Treatment (Nonenclosed Adequately Ventilated Area) Open Top Below Grade Separator or Preseparator Open Top Above Grade Separator or Preseparator Fixed Roof Above Grade Separator or Preseparator Open Top Below Grade Dissolved Air Flotation (DAF) Unit Open Top Above Grade Dissolved Air Flotation (DAF) Unit Fixed Roof Above Grade Dissolved Air Flotation (DAF) Unit Open Top Below Grade Biological Oxidation (BIOX) Unit Open Top Above Grade Biological Oxidation (BIOX) Unit Fixed Roof Above Grade Biological Oxidation (BIOX) Unit Injecton Well without Cellar or Below Grade Sump Injecton Well with Inadequately Ventilated Cellar or Below Grade Sump Below grade Closed Sump or Oily Water Separator with Vent to Carbon Cannisters and Access Hatch(es) 1. Figure 27 – Detail 4 2. Figure 100 – Detail B 1. Figure 27 – Detail 4 but without Vent classification 2. Add Vent note “To Carbon Cannisters” 3. Figure 100 – Detail B Figure 27 – Detail 1 Figure 7 Figure 6 Figure 27 – Detail 2 Figure 7 Figure 6 Figure 27 – Detail 3 Figure 7 Figure 6 Figure 39 Figure 40 General Process Equipment Above Grade Source with Closure (Nonenclosed Adequately Ventilated Area) Cooling Tower Diverter Line Outlet handling Flammable or Combustible Liquid Pig Launching or Receiving Installation handling Flammable or Combustible Liquid Process Filter or Strainer handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Mechanical Draft handling Process Cooling Water Page 4 of 10 Figure 89 Figure 49 Figure 102 Figure 28 Cross Reference Table for Area Classification Details (cont.) Equipment Dust Handling Equipment (Indoor with Enclosed Operating Equipment) Dust Handling Equipment (Indoor with Open or Semi-Enclosed Operating Equipment) Dust Handling Equipment (Indoor, Walled Off Area, Enclosed Operating Equipment) Fired Equipment Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 General Process Equipment (cont.) Groups F or G Dust with no visible dust cloud, dust layer less than 1/8 inch and surface color not discernable Groups F or G Dust with no visible dust cloud or dust layer and surface color discernable Group E Dust with moderate or dense dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Groups F or G Dust with moderate or dense dust cloud to no visible dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Group E Dust Fired Heater with air-aspirated burners Fired Heater with FD fan or FD/ID fans and safety shutdown system Fired Heater with FD fan or FD/ID fans and no safety shutdown system Flare Flammable GasBlanketed and Produced Water-Handling Equipment Located Outdoors at Grade in a Nonenclosed Adequately Ventilated Area Located at Grade in Adequately Ventilated Enclosed Area and all Vents extend outside enclosed area Located at Grade in Adequately Ventilated Enclosed Area and all Vents do not extend outside enclosed area Located at Grade in an Inadequately Ventilated Enclosed Area Page 5 of 10 Figure 5.8(c) Figure 5.8(d) Figure 5.8(b) Figure 5.8(a) Figure 5.8(f) Unclassified entending out 10 feet from perimeter of burner bank Unclassified Figure 48 Unclassified entending out 10 feet from tip Figure 50 Figure 50 with Division 2 for the remainder of the extent of enclosed area Figure 50 with the remainder of the extent of enclosed area Division 1 Figure 50 with Division 1 for the extent of enclosed area Cross Reference Table for Area Classification Details (cont.) Equipment More than One Piping System With Multiple Valves, Screwed Fittings, Flanges, Hoses, etc. in Close Proximity: Metering Skid Manifolds Prover Skid Sampler System Chemical Injection Skid Plate and Frame Filter Press (Adequate Ventilation) Product Dryer (Inside Adequately Ventilated Butilding) Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 General Process Equipment (cont.) Located Outdoors at Grade handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Located Outdoors at Grade handling Cold Liquefied Flammable Gas including Liquefied Natural Gas Located in Inadequately Ventilated Process Location handling HeavierThan-Air Flammable or Combustible Gas or Vapor or Highly Volatile Liquid (HVL) Located in Inadequately Ventilated Process Location handling LighterThan-Air Flammable or Combustible Gas or Vapor Located Inside Adequately Ventilated Roofed Building with One or More Sides handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Located Inside Adequately Ventilated Roofed Building with One or More Sides handling Cold Liquefied Flammable Gas including Liquefied Natural Gas Located Inside Inadequately Ventilated Roofed Building with One or More Sides handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling a Solid wet with a Flammable Liquid Handling a Solid wet with a Flammable Liquid Figure 96 Figure 5.9.1(g) Figure 5.9.11 Figure 22 Figure 26 Figure 97 Figure 5.9.13 Figure 5.9.12 Figure 98 Figure 5.9.3(b) Figure 5.9.3(a) Hydrocarbon Pressure Vessels (e.g. Heat Exchanger (Hazardous Material Shell-side), Fin-Fan Heat Exchanger, Reactor, Accumulator, Oil-gas Separator, Tower) Multiple Sources of Leakage from Process Equipment Located on More than One Floor In Adequately Ventilated Building Handling a Flammable Liquid In Outdoor Process Area Handling a Flammable Liquid Page 6 of 10 Figure 5.9.1(n) Figure 5.9.1(k) or Figure 5.9.1(l) or Figure 5.9.1(m) Cross Reference Table for Area Classification Details (cont.) Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Hydrocarbon Pressure Vessels (cont.) (e.g. Heat Exchanger (Hazardous Material Shell-side), Fin-Fan Heat Exchanger, Reactor, Accumulator, Oil-gas Separator, Tower) Equipment Vessel (Inside Inadequately Ventilated Process Enclosure) Vessel (Inside Adequately Ventilated Roofed Building with One or More Sides) Vessel (Inside Inadequately Ventilated Roofed Building with One or More Sides) Vessel (Indoor with Enclosed Operating Equipment) Vessel (Indoor with Open or Semi-Enclosed Operating Equipment) Vessel (Indoor, Walled Off Area, Enclosed Operating Equipment) Handling Heavier-Than-Air Flammable or Combustible Gas or Vapor or Highly Volatile Liquid (HVL) Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Source above Floor Level handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling Cold Liquefied Gas including Liquefied Natural Gas Handling Lighter-Than-Air Flammable or Combustible Gas or Vapor Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Groups F or G Dust with no visible dust cloud, dust layer less than 1/8 inch and surface color not discernable Groups F or G Dust with no visible dust cloud or dust layer and surface color discernable Group E Dust with moderate or dense dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Groups F or G Dust with moderate or dense dust cloud to no visible dust cloud, dust layer greater than 1/8 inch to less than 1/8 inch and surface color not discernable Group E Dust Page 7 of 10 Figure 22 Figure 26 Figure 105 Figure 97 Figure 5.9.1(j) Figure 5.9.1(d) Figure 5.9.12 Figure 106 Figure 98 Figure 5.9.1(i) Figure 5.8(c) Figure 5.8(d) Figure 5.8(b) Figure 5.8(a) Figure 5.8(f) Cross Reference Table for Area Classification Details (cont.) Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Hydrocarbon Pressure Vessels (cont.) (e.g. Heat Exchanger (Hazardous Material Shell-side), Fin-Fan Heat Exchanger, Reactor, Accumulator, Oil-gas Separator, Tower) Equipment Vessel Below Grade (Inadequately Ventilated Area) Vessel at Grade (Nonenclosed Adequately Ventilated Area) Vessel Above Grade (Nonenclosed Adequately Ventilated Area) Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling Flammable or Combustible Liquid Handling Cold Liquefied Flammable Gas including Liquefied Natural Gas Handling Flammable or Combustible Liquid Figure 101 Handling Highly Volatile Liquid (HVL) Figure 21 with Figure 99 Figure 48 Figure 5.9.11 Figure 99 Handling Cold Liquefied Flammable Gas including Liquefied Natural Gas Handling Liquified or Compressed Flammable Gas or Cryogenic Flammable Liquid When Flammable Gas is vented to the inside of enclosure (control panel) Figure 64 Adequately ventilated control panel (enclosure) with instruments inside Inadequately ventilated control panel (enclosure) with instruments inside Located in nonenclosed adequately ventilated area Figure 66 Adequately ventilated area Inadequately ventilated area Figure 63 Located in enclosed inadequately ventilated area Sample Valve (Discharge located in Enclosed Area) Figure 65 Division 2 extends 18 inches from stem seal (not shown on plot plan or support drawing) Division 2 to the extent of the enclosed area Division 1 to the extent of the enclosed area Figure 61 Located in enclosed adequately ventilated area Page 8 of 10 Figure 5.9.1(b) or Figure 5.9.1(h) or Figure 5.9.2(b) Figure 5.9.1(b) or Figure 5.9.1(h) Figure 5.9.11 Figure 5.9.2(b) Instrumentation Control Panel (Enclosure) for Instruments having Connections to Flammable or Combustible Fluids (Instruments located Inside or Attached to Panel) Process Control Valve Figure 5.9.1(g) Cross Reference Table for Area Classification Details (cont.) Equipment Pump Below Grade but External to Associated Equipment (Inadequately Ventilated Area) Pump at Grade (Outdoors) Pump (Outdoors but Under Roofed Building without Sides) Pump (Inside Adequately Ventilated Roofed Building with One or More Sides) Pump (Inside Inadequately Ventilated Roofed Building with One or More Sides) Specific Equipment/Scenario Pumps Pump associated with Oil-gas Separator, Receiver, Sump, etc. handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling Flammable or Combustible Liquid Handling Highly Volatile Liquid (HVL) Handling Liquefied or Compressed Flammable Gas or Flammable Cryogenic Liquid Handling Flammable or Combustible Liquid Handling Highly Volatile Liquid (HVL) Handling Flammable or Combustible Liquid Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Handling Flammable or Combustible Liquid Handling Flammable or Combustible Liquid or Highly Volatile Liquid (HVL) Cross Reference for Area Classification Details Per Recommended Practices API RP 500 NFPA 497 NFPA 499 Figure 101 Figure 51 Figure 5.9.2(a) Figure 93 Figure 5.9.1(a) Figure 5.9.2(a) Figure 52 Figure 52 with Figure 93 Figure 53 Figure 94 Figure 5.9.1(c) or Figure 5.9.1(e) Figure 54 Figure 95 Figure 5.9.1(f) Storage Storage Area Storage Tank (Nonenclosed Adequately Ventilated Area) Storage Tank for Cryogenic and other Cold Liquefied Flammable Gases (Outdoors) Bags Drums Closed Hoppers handling Groups E, F, or G Dusts Fixed Roof Flammable Liquid Storage Tank Fixed Roof Flammable Liquid Storage Tank with Internal Floating Roof Open Top Floating Roof Flammable Liquid Storage Tank Fixed Roof Combustible Liquid Storage Tank Dike height less than distance from container to dike Dike height greater than distance from container to dike Conainer with liquid level below grade or top of dike Page 9 of 10 Figure 5.8(e) Figure 6 Figure 5.9.4(a) Figure 6 Figure 7 Figure 8 Figure 5.9.10(a) Figure 5.9.10(b) Figure 5.9.10(c) Cross Reference Table for Area Classification Details (cont.) Equipment Cross Reference for Area Classification Specific Details Per Recommended Practices Equipment/Scenario API RP 500 NFPA 497 NFPA 499 Storage (cont.) Storage for Hydrogen (Indoors in an Adequately Ventilated Building) Storage for Hydrogen (Outdoors) Gaseous Hydrogen only Figure 5.9.8(b) Liquid Hydrogen only Figure 5.9.8(a) Gaseous Hydrogen only Liquid Hydrogen only Figure 5.9.8(b) Figure 5.9.8(a) Vent To Atmosphere (Nonenclosed Adequately Ventilated) From a Division 1 Area Vents Vent To Atmosphere (Indoors Adequately Ventilated Building) From a Division 2 Area From Instrument or Control Device (Low Pressure) From Process Equipment From Relief Valve From Rupture Disk From source handling Cryogenic Flammable Liquids including Natural Gas From source handling Cryogenic Flammable Liquids including Natural Gas Figure 16 or Figure 87 Figure 17 or Figure 88 Figure 15 Figure 14 Figure 18 Figure 18 Figure 5.9.13, Bottom Detail Figure 5.9.13, Top Detail Notes: 1. NFPA Figures above use “Division” nomenclature. The use of NFPA Figures with “Zone” nomenclature is discouraged. 2. See Section 5.10 for Highly Volatile Liquid (HVL), Flammable Liquid, and Combustible Liquid definitions. 3. Specific radius dimensions for use with the Figures above should be obtained from Gas/Vapor Dispersion modeling results. 4. If modeling results cannot be obtained (e.g. composition of material is unknown), use the recommended radius per the specific figure. Page 10 of 10
© Copyright 2026 Paperzz