Installation Instructions PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Introduction Important: The Power Modules on PowerFlex 700S and 700H frame 12 drives are matched at the factory and cannot be paired with any other Power Modules. Therefore, when a Power Module fails, you must replace both power structures on a frame 12 drive. Use this document to install the replacement power structures on a frame 12 drive. This document covers the following replacement power structures: Spare Module Catalog String SK-H1-PWRMOD-F12D SK-H1-PWRMOD-F12E PowerFlex 700H AC Input 20CC820 20CD820 20CC920 20CD920 20CC1K0 20CD1K0 20CE650 20CF650 20CE750 20CF750 20CE820 20CF820 PowerFlex 700H DC Input 20CH820 20CJ820 20CH920 20CJ920 20CH1K0 20CJ1K0 20CK650 20CM650 20CK750 20CM750 20CK820 20CM820 PowerFlex 700S AC Input 20DC820 20DD820 20DC920 20DD920 20DC1K0 20DD1K0 20DE650 20DF650 20DE750 20DF750 20DE820 20DF820 PowerFlex 700S DC Input 20DH820 20DJ820 20DH920 20DJ920 20DH1K0 20DJ1K0 20DK650 20DM650 20DK750 20DM750 20DK820 20DM820 Note: The frame 12 power structure kit does not contain the drive-rated ASIC boards. You must either use the existing ASIC boards or order replacement ASIC boards in order to complete this installation. Please refer to the Spare Parts and Options List for PowerFlex Architecture (7) Class Low Voltage AC Drives for part catalog numbers. This list is located at: www.ab.com/support/abdrives/powerflex700s/phase2/index.html From this page, click on the “Parts List” link to view a PDF of the parts list for both 700S and 700H drives. 2 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures What You Need to Do This document contains directions for replacing one power structure mounted in a Rittal TS8 drive enclosure. These steps must be repeated for the installation of the second power structure. ❐ Step 1: Remove power from existing drive ❐ Step 2: Remove protective covers from existing drive ❐ Step 3: Prepare old power structure for removal ❐ Step 4: Remove old power structure from drive ❐ Step 5: Remove existing ASIC board from old power structure (optional) ❐ Step 6: Install ASIC board on new power structure ❐ Step 7: Configure EMC filter ❐ Step 8: Install new power structure ❐ Step 9: Connect power structure to components on drive ❐ Step 10: Install product identification label on new power structure ❐ Step 11: Start drive Step 1: Removing Power from the Existing Drive ! ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before servicing the drive. Check the DC bus voltage at the Power Terminal Block by measuring between the +DC and -DC terminals, between the +DC terminal and the chassis, and between the -DC terminal and the chassis. The voltage must be zero for all three measurements. Remove power before making or breaking cable connections. When you remove or insert a cable connector with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: • sending an erroneous signal to your system’s field devices, causing unintended machine motion • causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 3 1. Turn off and lock out input power and wait five minutes. 2. Verify that there is no voltage at the drive’s input power terminals. 3. Measure between the +DC and -DC terminals, between the +DC terminal and the chassis, and between the -DC terminal and the chassis. The voltage must be zero for all three measurements. L1 L2 L3 I O Step 2: Removing the Protective Covers from the Existing Drive 1. Open the enclosure door and loosen the T8 Torx-head screws that hold the control frame to the drive enclosure. 2. Swing the control frame out and away from the power structure. Loosen screws Control assembly not shown for clarity only. 4 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 3. Remove the T8 Torx-head screws which secure the airflow plate to the drive. 4. Slide airflow plate off the enclosure frame. Remove screws PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 5 5. Remove the four M5 POZIDRIV screws that hold the top and bottom protective covers to the main front protective cover, then remove the top and bottom protective covers. 6. Remove the four M5 POZIDRIV screws that hold the main front protective cover to the drive, then remove the protective cover. 7. remove the side protective covers. Screws Screws Screws 6 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 3: Preparing the Old Power Structure for Removal 1. Remove the motor wiring from the power structure at the front of the power structure. 2. Remove the ground connection from the lower right rear corner of the power structure. 3. Remove the input (AC or DC) from the incoming terminals at the top of the power structure. ASIC board AC Power connection terminals Power Supply Voltage Feedback board Motor connection terminals Drive frame ground connection PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 7 4. Carefully disconnect the fiber-optic cables from sockets along the front of the ASIC board, and carefully set them aside. ! ATTENTION: Hazard of permanent eye damage exists when using optical transmission equipment. This product emits intense light and invisible radiation. Do not look into fiber-optic ports or fiber-optic cable connectors. ! ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure are energized at (-) DC bus potential high voltage. Risk of electrical shock, injury, or death exists if someone comes in contact with the assembly. 5. Disconnect the other cables from the sockets on the front of the ASIC board, and set them aside. H8 Connects to X50 terminal block for pre-charge circuitry on DC Input drives X2 X11 X9 H9 H10 H11 X15 X26 H12 H1 H13 H2 H3 X3 Fiber Optic ports H4 X1 H5 H6 X4 H7 X6 X5 Connects to DC Bus 6. If you are replacing a power structure on a PowerFlex 700S drive, disconnect the cable from connector J8 and the fiber optic connections, J4 and J5, from the Power Supply Voltage Feedback board on the power structure in the left-hand enclosure. J4 J5 J8 8 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 4: Removing the Old Power Structure from the Drive 1. Follow the instructions in publication PFLEX-IN014…, Installation Instructions - PowerFlex 700S /700H High Power Maintenance Stand, to install the Maintenance Stand (part number 20-MAINSTND). Slide the power structure out of the enclosure onto the rails of the Maintenance Stand. Note: The Maintenance Stand is designed for removing power structures from drives supplied in Rittal TS8 enclosures. Alternate means of removal will be necessary for other types of enclosures. 2. Remove the old power structure from the maintenance stand using the following lifting instructions: Note: Frame 12 power structures weight approximately 120 kg (265 lbs.). a. Attach the lifting hardware to the power structure. The lifting hardware must be fastened symmetrically to at least two of the lifting holes on the unit. Lifting points b. Lift the power structure off of the maintenance stand and place the back side of the unit onto a sturdy palette. PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 5: Removing the Existing ASIC Board from the Old Power Structure 9 Important: If you are installing a new ASIC board, continue with Step 6 “Installing the ASIC Board on the New Power Structure” on page 10. If you are installing the existing ASIC board, continue with step 1 below. ! ATTENTION: Hazard of permanent eye damage exists when using optical transmission equipment. This product emits intense light and invisible radiation. Do not look into fiber-optic ports or fiber-optic cable connectors. ! ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure are energized at (-) DC bus potential high voltage. Risk of electrical shock, injury, or death exists if someone comes in contact with the assembly. 1. Carefully disconnect the remaining fiber-optic cables from sockets of the ASIC board, and carefully set them aside. Figure 1 Termination Points on the ASIC Board Connects X13 to Rectifying board on AC drives X2 X11 H8 X9 H9 Fiber Optic ports H10 H11 X15 X26 H12 H1 H13 H2 H3 X3 X1 Connects to Gate Driver board X4 H4 H5 H6 H7 X5 X6 2. Disconnect the remaining cables from sockets on the front of the ASIC board, and set them aside. 3. Remove the screws that secure the ASIC assembly to the drive and set the assembly aside. 10 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 6: Installing the ASIC Connecting a DC Input Drive Board on the New Power Power structures are shipped from the factory pre-configured for DC input Structure operation. Connecting an AC Input Drive If you are installing an existing ASIC board on the new power structure, continue with step 11 on page 12. If you are installing a new ASIC board on the new power structure, continue with step 1 below. 1. Remove the cover from the existing ASIC assembly and the DC- bus connection from the cover. 2. Unplug the fan that mounts on the ASIC assembly cover from connector X1 of the ASIC board. 3. Disconnect the Feedback board that mounts on the ASIC assembly cover from connector X26 on the ASIC board. X26 Feedback board connection X2 X11 H8 X1 Fan connection X9 H9 H10 H11 X15 X26 H12 H1 H13 H2 H3 X3 X1 X4 H4 H5 H6 H7 X5 X6 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 11 4. Slide the old ASIC board out of its chassis. 5. Slide the new ASIC board into the chassis. ASIC Board 6. If you are installing a replacement power structure on a drive with AC input, remove the X2 plug from its protective sleeve and plug the cable into the X2 socket on the ASIC board. X26 Feedback board connection To X13 connection on Rectifying board X2 X11 H8 X9 H9 H10 H11 X1 Fan connection X15 X26 H12 H1 H13 H2 H3 X3 X1 X4 H4 H5 H6 H7 X5 X6 7. Connect the other end of the cable connected to X2 on the ASIC board to X13 on the Rectifier circuit board on the upper right side of the power structure. 8. Connect the cable from the Feedback board to the X26 connector on the ASIC board. 9. Plug the fan that mounts on the ASIC assembly cover into the X1 connector on the ASIC board. 12 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 10. Secure the cover of the ASIC assembly and reconnect the DC- bus cable to the cover. 11. Secure the ASIC board and assembly to the new power structure. ! ATTENTION: Hazard of permanent eye damage exists when using optical transmission equipment. This product emits intense light and invisible radiation. Do not look into fiber-optic ports or fiber-optic cable connectors. 12. Connect the remaining cables and fiber-optic cables to the ASIC board in the reverse order of Step 5: "Removing the Existing ASIC Board from the Old Power Structure" on page 9. Step 7: Configuring the EMC Filter Frame 12 size drives are equipped with common mode capacitors and capacitors that are connected to the input terminals. To guard against drive damage, these capacitors should be disconnected depending upon the type of ground system on which the drive is installed. Installation on an Ungrounded Distribution System or High Resistive Ground If you are installing a 400/480V AC input drive on an ungrounded distribution system or high resistive ground, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 14. • Should insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 15. • Must disconnect the small capacitors from the input terminals - refer to Disconnect the Small Capacitors from the Input Terminals on page 16. If you are installing a 600/690V AC input drive on an ungrounded distribution system or high resistive ground, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 14. • Must insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 15. • Must disconnect the small capacitors from the input terminals - refer to Disconnect the Small Capacitors from the Input Terminals on page 16. PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 13 Installation on a Grounded B Phase Delta System If you are installing a drive on a grounded B phase Delta system, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 14. • Must insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 15. • Must disconnect the small capacitors from the input terminals - refer to Disconnect the Small Capacitors from the Input Terminals on page 16. Note: Refer to Wiring and Grounding Guidelines for Pulse Width Modulated (PWM) AC Drives - Installation Instructions, publication DRIVES-IN001…, for additional information on an ungrounded distribution system or high resistive ground installation. Figure 2 Common Mode Jumper and Rectifier Circuit Board Location Common Mode jumper There is one jumper located on each Rectifying Module. The Rectifying Modules are located on the upper-right side of the right side power stack of in each enclosure of the drive’s power structure. Front View of Assembly Rectifier Circuit Board DANGER DC BUS CONDUCTORS AND CAPACITORS OPERATE AT HIGH VOLTAGE. REMOVE POWER AND WAIT 5 MINUTES BEFORE SERVICING DANGER DC BUS CONDUCTORS AND CAPACITORS OPERATE AT HIGH VOLTAGE. REMOVE POWER AND WAIT 5 MINUTES BEFORE SERVICING Control Frame not shown for clarity only 14 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Move the Common Mode Jumper to the Disconnected Position Follow the lettered steps below to move the common mode jumper to the disconnected position (refer to Figure 2 on page 13 for jumper location): Task A Description Loosen the upper screw. B Remove the lower screw. Move the jumper to the horizontal position. C Install and tighten the screws. D A Front View of Power Structure D C B Rectifier Circuit Board PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 15 Insulate Terminal X4 on the Rectifier Circuit Board Follow the lettered steps below to insulate terminal X4 on the Rectifier circuit board (refer to Figure 2 on page 13 for Rectifier board location): Task A Description Remove the screw from the X4 connection on the Rectifier circuit board. B Insulate the top and bottom of the X4 connection on the Rectifier circuit board. Important: Do not install the screw and washer that was removed from this connection. A Side View of Power Structure B X4 X4 X1 X1 X41 X41 Rectifier Circuit Board 16 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Disconnect the Small Capacitors from the Input Terminals Follow the lettered steps below to disconnect the small capacitors from the input terminals: Task A B C Description Remove the screws and lock washers that secure each of the three capacitor supply wires to the input power terminals. Insulate the capacitor leads and leave disconnected. Install and tighten the screws and lock washers only. Important: Do not re-install the capacitor leads. Important: It is not necessary to remove the power wiring from the terminals in order to insulate the capacitor leads. L1 L2 L3 Input power terminal Insulator B A Capacitor Capacitor lead C Step 8: Installing the New Power Structure Install the new power structure in the reverse order of Step 4: "Removing the Old Power Structure from the Drive" on page 8 and make the motor, ground, input power and Power Supply Voltage Feedback board (for PowerFlex 700S installations) connections in the reverse order of Step 3: "Preparing the Old Power Structure for Removal" on page 6. PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 9: Connecting the Power Structure to Components on the Drive 17 You must connect the power structure to control components on the control frame. If the drive has DC input, you must also connect the precharge circuit. Figure 3 700S Connections 6 H903 1 X900 H900 H901 H902 25 26 M 2 3 Sample Pre-Charge Connection Shown in Dashed Lines CR1 1 Fiber Optic 2 4 6 X6 +24V 0EVA DC+ 1 2 3 3 5 7 From DC Bus in Power Circuitry DC- To Rectifying Board X13 To Gate Driver Board X13 To Gate Driver Board X14 To Gate Driver Board X15 To Gate Driver Board H4 To Gate Driver Board H5 To Gate Driver Board H6 To Gate Driver Board H7 To Gate Driver Board H8 To Gate Driver Board H9 X2 X3 X4 X5 H8 H9 H10 X10 24V Power H11 H12 H1 H13 H2 X600 H3 X11 H4 Fan H5 Control H6 H7 X50 PS #1 CR2 M ASIC Board #1 X15 21 Charge 22 23 Relay X1 +24VDC 1 2 DC- 4 M CR1 X26 X9 3 On Power Structure #1 (Left) Feedback Board #1 To Left Fan X8 External Wiring Shown as Dashed Lines 6 X900 1 M Feedback Board #2 25 26 2 3 X26 X9 ASIC Board #2 +24V 0EVA X15 21 Charge 22 23 Relay X1 +24VDC 1 2 DC- 4 X50 PS #2 X10 24V Power 1 2 4 6 Fiber Optic Fiber Optic Fan Power J18 J15 J6 J7 DPI J4 LED J16 Status External 24V DC 1=24V 3=Common (75W min) 700S Phase II Control Assembly 8 X2 X3 X4 X5 H8 H9 H10 H11 H12 H13 X600 X11 Fan Control DC+ 1 2 3 From DC Bus in Power Circuitry DC- To Rectifying Board X13 To Gate Driver Board X13 To Gate Driver Board X14 To Gate Driver Board X15 To Gate Driver Board H4 To Gate Driver Board H5 To Gate Driver Board H6 To Gate Driver Board H7 To Gate Driver Board H8 To Gate Driver Board H9 3 To Left Fan X8 DC- From Power Structure J2 80 W J8 +24V Power -DCSupply -DC+ J1 9 -U J4 -V -W 8 J5 DC+ From Power Structure U/T1 Phase from Pwr Strctr V/T2 Phase from Pwr Strctr W/T3 Phase from Pwr Strctr 2 J1 2 To Main Control Board 2 J5 +24 V Iso +12 V -12 V +5V Star Coupler Fiber Optic Interface Board J2 7 Common Mode FIlter Board J17 J1 5 T 6 4 2 7 5 3 1 J27 J24 J25 J23 J22 J21 J20 J19 J3 J28 J13 J14 J12 J11 J10 J9 J8 T 6 4 2 7 5 3 1 H1 H2 H3 H4 H5 H6 H7 3 X6 J5 Fiber Power Supply Voltage Feedback Board 9 9 20-VB00601 X2 2 X1 X4 HIM Bezel J2 DPI Interface J1 J3 X3 20 DPI Comm Option On Power Structure #2 (Right) H903 H900 H901 H902 9 PWR STS PORT MOD NET A NET B DPI Assembly 9 HIM Door Example: 20-HIM-A3 HIM External DPI 18 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures ASIC Board Connections - Power Structure #1 Connect this component : termination point . . . ASIC Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) ASIC Board: X6 ASIC Board: X3 ASIC Board: X4 ASIC Board: X5 ASIC Board: H8 (fiber optic connector) ASIC Board: H9 (fiber optic connector) ASIC Board: H10 (fiber optic connector) ASIC Board: H11 (fiber optic connector) ASIC Board: H12 (fiber optic connector) ASIC Board: H13 (fiber optic connector) ASIC Board: X11 ASIC Board: X2 to this component : termination point Star Coupler Fiber Optic Interface Board: J8 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J9 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J10 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J11 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J12 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J14 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J13 (fiber optic connector) From DC Bus Gate Driver Board Power Structure #2: X13 Gate Driver Board Power Structure #2: X14 Gate Driver Board Power Structure #2: X15 Gate Driver Board Power Structure #2: H4 Gate Driver Board Power Structure #2: H5 Gate Driver Board Power Structure #2: H6 Gate Driver Board Power Structure #2: H7 Gate Driver Board Power Structure #2: H8 Gate Driver Board Power Structure #2: H9 Left Fan on Power Structure #2: X8 Rectifying Board: X13 ASIC Board Connections - Power Structure #2 Connect this component : termination point . . . ASIC Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) ASIC Board: X6 ASIC Board: X3 ASIC Board: X4 ASIC Board: X5 ASIC Board: H8 (fiber optic connector) ASIC Board: H9 (fiber optic connector) ASIC Board: H10 (fiber optic connector) ASIC Board: H11 (fiber optic connector) ASIC Board: H12 (fiber optic connector) ASIC Board: H13 (fiber optic connector) ASIC Board: X11 ASIC Board: X2 to this component : termination point Star Coupler Fiber Optic Interface Board: J19 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J20 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J21 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J22 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J23 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J25 (fiber optic connector) Star Coupler Fiber Optic Interface Board: J24 (fiber optic connector) From DC Bus Gate Driver Board Power Structure #1: X13 Gate Driver Board Power Structure #1: X14 Gate Driver Board Power Structure #1: X15 Gate Driver Board Power Structure #1: H4 Gate Driver Board Power Structure #1: H5 Gate Driver Board Power Structure #1: H6 Gate Driver Board Power Structure #1: H7 Gate Driver Board Power Structure #1: H8 Gate Driver Board Power Structure #1: H9 Left Fan on Power Structure #1: X8 Rectifying Board: X13 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 19 Figure 4 Termination Points on the ASIC Boards Connects to X13 on Rectifying circuit board on AC Input drives X2 X11 H8 Connects to fan on ASIC assembly cover X9 H9 H10 X15 X26 H11 H12 H1 H13 H2 Connect to X50 terminal block for Pre-charge circuitry on DC Input drives H3 X3 H4 X1 H5 H6 ahw0994.eps X4 H7 Connects to DC Bus X6 X5 Figure 5 Termination Points on the Gate Driver Board Fiber Optic Connections to ASIC Board H8 H6 H4 H9 H7 H5 X3 X8 X4 X9 X5 X10 X6 X11 X12 X7 X13 X14 X15 X1 Connect to ASIC Board 20 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures ASIC Feedback Board Connections - Power Structure #1 Connect this component : termination point . . . ASIC Feedback Board: X900 ASIC Feedback Board: H903 to this component : termination point ASIC Board Power Structure #1: X26 Star Coupler Fiber Optic Interface Board: J28 ASIC Feedback Board Connections - Power Structure #2 Connect this component : termination point . . . ASIC Feedback Board: X900 ASIC Feedback Board: H903 to this component : termination point ASIC Board Power Structure #2: X26 Star Coupler Fiber Optic Interface Board: J27 Figure 6 Termination Points on ASIC Feedback Boards H900 X900 H901 H902 Fiber Optic Ports H903 Power Supply Voltage Feedback Board Connections Connect this component : termination point . . . Power Supply Voltage Feedback Board: J8 Power Supply Voltage Feedback Board: J5 (fiber optic connector) Power Supply Voltage Feedback Board: J4 (fiber optic connector) to this component : termination point Common Mode Filter Board: J5 Star Coupler Fiber Optic Interface Board: J7 Star Coupler Fiber Optic Interface Board: J6 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 21 Figure 7 Termination Points on 700S Boards Star Coupler Fiber Optic Interface Board Power Supply Voltage Feedback Board J4 J5 J28 J13 J14 J12 J11 J10 J9 J8 J8 J7 J6 J27 J24 700S Common Mode FIlter Board J25 J23 J22 J1 J21 J20 J19 J5 J5 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Figure 8 700H Connections Feedback Board #1 X26 X9 1 25 M 26 2 3 Sample Pre-Charge Connection Shown in Dashed Lines 4 M CR1 X1 2 2 X10 24V Power H1 H2 H3 H4 H5 H6 H7 2 3 4 5 6 7 6 X900 X9 1 M 26 +24V 0EVA 21 22 23 X15 Charge Relay 25 2 3 4 X1 X50 PS #2 1 2 X10 Fiber Optic H1 H2 H3 H4 H5 H6 H7 1 2 3 4 5 6 7 2 1 2 1 2 +24VDC GND 5 7 T 6 3 4 1 2 X2 X3 X4 X5 +24VDC H8 DCH9 24V Power H10 H11 H12 H13 X600 Fan X11 Control 22 23 21 Star Coupler Fiber Optic Interface Board DPI Interface X1 37 20-VB00601 X2 X1 Control Board Programming X2 (slot A) Analog I/O Plus Digital In 24V Or 115V 20C-DA1-A 2OC-DA1-B Analog I/O Digital In (10) (8/10) X3 (slot B) X4 (slot C) X5 (slot D) X6 (slot E) 20C-D01 3 Option Board Option Board DPI Option 20C-DPI1 X2 X3 3 700H Control Assembly X1 X4 X3 X7 X1 Digital Out Option To Rectifying Board X13 To Gate Driver Board X13 To Gate Driver Board X14 To Gate Driver Board X15 To Gate Driver Board H4 To Gate Driver Board H5 To Gate Driver Board H6 To Gate Driver Board H7 To Gate Driver Board H8 To Gate Driver Board H9 3 To Left Fan X8 9 20 DPI Comm Option 20C-DPI1 HIM Bezel J2 J1 J3 9 PWR PORT MOD NET A NET B DPI Assembly DC+ 1 2 3 DC- H23 H22 H21 X2 3 4 H18 H17 H16 H15 H14 H13 H12 H11 5 X6 Fiber Optic Fiber Optic 6 ASIC Board #2 X26 3 7 From DC Bus in Power Circuitry Fiber Optic H903 T DC- External Wiring Shown as Dashed Lines Feedback Board #2 H900 H901 H902 DC+ 1 2 3 X5 H8 H9 H10 H11 H12 H13 X600 X11 Fan Control +24VDC DC- CR1 1 X6 X2 X3 X4 X15 Charge Relay 1 X50 PS #1 CR2 M 21 22 23 +24V 0EVA ASIC Board #1 On Power Structure #1 6 X900 9 HIM Door Example: 20-HIM-A3 HIM External DPI From DC Bus in Power Circuitry To Rectifying Board X13 To Gate Driver Board X13 To Gate Driver Board X14 To Gate Driver Board X15 To Gate Driver Board H4 To Gate Driver Board H5 To Gate Driver Board H6 To Gate Driver Board H7 To Gate Driver Board H8 To Gate Driver Board H9 3 To Left Fan X8 On Power Structure #2 H903 H900 H901 H902 3 H8 H7 H6 H5 H4 H3 H2 H1 22 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 23 ASIC Board Connections - Power Structure #1 Connect this component : termination point . . . ASIC Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) ASIC Board: X6 ASIC Board: X3 ASIC Board: X4 ASIC Board: X5 ASIC Board: H8 (fiber optic connector) ASIC Board: H9 (fiber optic connector) ASIC Board: H10 (fiber optic connector) ASIC Board: H11 (fiber optic connector) ASIC Board: H12 (fiber optic connector) ASIC Board: H13 (fiber optic connector) ASIC Board: X11 ASIC Board: X2 to this component : termination point Star Coupler Fiber Optic Interface Board: H1 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H2 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H3 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H4 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H5 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H6 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H7 (fiber optic connector) From DC Bus Gate Driver Board Power Structure #2: X13 Gate Driver Board Power Structure #2: X14 Gate Driver Board Power Structure #2: X15 Gate Driver Board Power Structure #2: H4 Gate Driver Board Power Structure #2: H5 Gate Driver Board Power Structure #2: H6 Gate Driver Board Power Structure #2: H7 Gate Driver Board Power Structure #2: H8 Gate Driver Board Power Structure #2: H9 Left Fan on Power Structure #2: X8 Rectifying Board: X13 Note: Refer to page 19for ASIC Board and Gate Driver Board termination points. ASIC Board Connections - Power Structure #2 Connect this component : termination point . . . ASIC Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) ASIC Board: X6 ASIC Board: X3 ASIC Board: X4 ASIC Board: X5 ASIC Board: H8 (fiber optic connector) ASIC Board: H9 (fiber optic connector) ASIC Board: H10 (fiber optic connector) ASIC Board: H11 (fiber optic connector) ASIC Board: H12 (fiber optic connector) ASIC Board: H13 (fiber optic connector) ASIC Board: X11 ASIC Board: X2 to this component : termination point Star Coupler Fiber Optic Interface Board: H11 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H12 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H13 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H14 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H15 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H16 (fiber optic connector) Star Coupler Fiber Optic Interface Board: H17 (fiber optic connector) From DC Bus Gate Driver Board Power Structure #1: X13 Gate Driver Board Power Structure #1: X14 Gate Driver Board Power Structure #1: X15 Gate Driver Board Power Structure #1: H4 Gate Driver Board Power Structure #1: H5 Gate Driver Board Power Structure #1: H6 Gate Driver Board Power Structure #1: H7 Gate Driver Board Power Structure #1: H8 Gate Driver Board Power Structure #1 : H9 Left Fan on Power Structure #1 : X8 Rectifying Board: X13 24 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures ASIC Feedback Board Connections - Power Structure #1 Connect this component : termination point . . . ASIC Feedback Board: X900 ASIC Feedback Board: H900, H901, H902 (fiber optic bundle) ASIC Feedback Board: H903 to this component : termination point ASIC Board Power Structure #1: X26 Star Coupler Fiber Optic Interface Board: H21, H22, H23 Star Coupler Fiber Optic Interface Board: H8 Note: Refer to page 20for ASIC Feedback Board termination points. ASIC Feedback Board Connections - Power Structure #2 Connect this component : termination point . . . ASIC Feedback Board: X900 ASIC Feedback Board: H903 to this component : termination point ASIC Board Power Structure #2: X26 Star Coupler Fiber Optic Interface Board: H18 Figure 9 Termination Points on the 700H Star Coupler Fiber Optic Interface Board H8 H7 H6 H5 H4 H3 H2 H1 H18 H17 H16 H15 H14 X2 H13 H12 H11 H23 H22 H21 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures 25 DC Input Precharge Control Wiring If you are installing a DC input drive with a precharge interlock you must make the following connections on the X50 terminal block from the precharge circuit. Refer to Figure 10 below for additional information. Frame 12 - X50 Terminal Block Connections X50 Terminal Block Terminal Description Power Module 1 3 Charge Relay Contact (Jumper to Power Module 2 Terminal 4) 4 Charge Relay Contact 1 1 Precharge Complete Signal (+24V DC) 2 Precharge Complete Signal (Common) Power Module 2 2 3 Charge Relay Contact 3 4 Charge Relay Contact (Jumper to Power Module 1 Terminal 21) 1 Precharge Complete Signal (+24V DC) 2 Precharge Complete Signal (Common) 4 Figure 10 Sample Precharge Wiring Diagram External precharge circuitry is shown as dashed lines. DC+ M PU1 X50 1 F1 M R1 CR2 2 X9 25 26 CR1 4 M Precharge Complete* ASIC Board #2 X15 3 DC Source Precharge Complete* ASIC Board #1 21 22 23 CR2 M CR1 M PU2 X50 DC- 1 M 2 F2 R2 CR2 X9 25 26 X15 3 4 21 22 23 *Refer to the “ASIC Board Charge Relay Contact Ratings” table below. ASIC Board Charge Relay Contact Ratings Load Rated load Rated carry current Max. switching voltage Max. switching current Max. switching power Failure rate (reference value) Resistance load (cos φ = 1) 8 A at 250 VAC: 5 A at 30 VDC 8A 250 VAC; 30 VDC, (400 VAC) AC 8 A; DC 5 A 2,000 VA; 150 W 5 VDC 10 mA (for gold plating 0.35 µ min.) 26 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Step 10: Installing the Product Identification Label on the New Power Structures All frame 12 replacement power structures are shipped form the factory without a product identification label on the drive. If you are installing the power structures in a 700S drive, you should label it with the accompanying PowerFlex 700S label. If you are installing the power structures in a 700H drive, you should label it with the accompanying PowerFlex 700H label. GER ! DAN TORS CAPACI E POWER ING AND REMOV SERVIC CTORS E. CONDU VOLTAG S BEFORE BUS HIGH DC E AT MINUTE 5 OPERAT WAIT AND R GE AN ! D TORS PACI POWER G D CA AN MOVE ICIN E. RE SERV TORS AG UC ND VOLT FORE S COHIGH TES BE BU DC E AT MINU AT T 5 ER OP D WAI AN OR Step 11: Starting the Drive 1. Replace the protective covers in the reverse order of Step 2: "Removing the Protective Covers from the Existing Drive" on page 3. 2. Start up the drive. Refer to the Start Up procedures in the appropriate publication: – User Manual - PowerFlex 700S Drives with Phase II Control, 20D-UM006 – Programming Manual - PowerFlex 700H Drives, 20C-PM001 PowerFlex® 700S and 700H Frame 12 Replacement Power Structures Reference Materials 27 Allen-Bradley publications are available on the internet at www.rockwellautomation.com/literature. The following manuals are recommended for general drive information: Title Industrial Automation Wiring and Grounding Guidelines Preventive Maintenance of Industrial Control and Drive System Equipment Safety Guidelines for the Application, Installation and Maintenance of Solid State Control A Global Reference Guide for Reading Schematic Diagrams Guarding Against Electrostatic Damage Publication 1770-4.1 DRIVES-TD001… SGI-1.1 0100-2.10 8000-4.5.2 The following manuals are recommended for detailed PowerFlex 700H and 700S information: Title Reference Manual - PowerFlex 700S Drives with Phase II Control User Manual - PowerFlex 700S Drives with Phase II Control Programming Manual - PowerFlex 700H Drives Installation Instructions - PowerFlex 700S and 700H High Power Drives Installation Instructions - PowerFlex® 700S and 700H High Power Maintenance Stand Publication PFLEX-RM003… 20D-UM006… 20C-PM001… PFLEX-IN006… PFLEX-IN014… For Allen-Bradley Drives Technical Support and access to the proper Hardware Service Manual: Title Allen-Bradley Drives Technical Support Online at... www.ab.com/support/abdrives www.rockwellautomation.com Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA,Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium,Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong,Tel: (852) 2887 4788, Fax: (852) 2508 1846 Publication PFLEX-IN012B-EN-P - August 200828 Supersedes PFLEX-IN012A-EN-P - March 2006 360403-P02 Copyright © 2008 Rockwell Automation. All rights reserved. Printed in the U.S.A.
© Copyright 2026 Paperzz