PROPANE FORKLIFT GAS PROGRAM Bulk Dispenser 20 Point Annual Inspection Checklist Customer Name: _________________________________________ Account #: ___________________________________________ PAPCO Inspector: ________________________________________ Date of Inspection: _____________________________________ 1. General Site 4. Piping [ ] Registered – Business License Displayed [ ] Proper materials used = NFPA 58 (2-4.2 : 2-5.1.2) [ ] Fire Extinguisher – 20 lbs dry chemical with B:C or A:B:C Rating = NFPA 58 (3-10.2.7) [ ] System is leak free = NFPA 58 (3-2.9) [ ] No Smoking Sign – no open flame, no ignition source within 15 feet = NFPA 58 (3-8.4) [ ] Lighting – if night fueling is done = NFPA 58 (3.3.7) [ ] Personnel Trained – for safe fueling = NFPA 58 (4-2.1.1) (1-6.1.1) [ ] Supported, protected and painted = NFPA 58 (3-2.7.6) (3-2.7.7) (3-2.3.1.c) 5. Hose [ ] Approved and marked = NFPA 58 (2-4.6.3) [ ] Good working condition = NFPA 58 (2-4.6) 2. Tank Location [ ] 10 feet from public ways = NFPA 58 (4-3.3) 6. Dispensing Point [ ] 25 feet from buildings, openings, pits, property lines, railroad tracks = NFPA 58 (4-3.3) [ ] Area not enclosed by more than 50 percent unless complying with Chapter 7 = NFPA 58 (3-2.10.6.a) [ ] 50 feet from outdoor public assembly = NFPA 58 (4-3.3) [ ] 5 feet from driveways = NFPA 58 (4-3.3) 7. Hydrostatic Relief Valves [ ] 20 feet from other fuels greater than 660 gallons capacity = NFPA 58 (3-2.2.5) [ ] In place and unobstructed = NFPA 58 (3-2.8 ; 3-2.10.6 ; 4-2.3.4) [ ] 15 feet from non-explosive proof electrical wiring and fixtures = NFPA 58 (3-8.2) 8. Flexible Connector [ ] 6 feet horizontally from overhead power lines of 600 volts or greater = NFPA 58 (3-2.2.6.i) [ ] Condition, three feet maximum = NFPA 58 (3-2.7.8) 9. Shutoff Valves 3. Tank [ ] Data plate is legible (stainless steel if manufactured after 1989) = NFPA 58 (2-2.6.5) [ ] Accessible, at the tank = NFPA 58 (3-2.4.6) [ ] Paint is in good condition = NFPA 58 (3-2.3.1.f) 10. Relief Valves [ ] Base and level = NFPA 58 (3-2.3.2) [ ] Covered for protection = NFPA 58 (3-2.4.3) [ ] Protection from Vehicles = NFPA 58 (3-2.3.1.c) [ ] Markings – identified as to gas supplier and filling instructions = NFPA 58 (general) 800-899-0747 ° 757-499-5977 ° papco.com 11. Fill Valves 16. Security [ ] Capped for protection = NFPA 58 (3-2.4.6) [ ] Dispensing point protected by 6 feet of industrial fence or cabinet = NFPA 58 (3-3.6) 12. Excess Flow Valves [ ] In tank openings = NFPA 58 (3-2.4.6) 17. Bulkhead and ESV [ ] Piping at hose connection = NFPA 58 (3-2.10.6.f) [ ] If tank is over 4,000 gallon capacity = NFPA 58 (3-2.7.9) 13. Scales 18. Tanks Other Than Those Being Filled [ ] Availability, condition and accuracy = NFPA 58 (general) [ ] Stored no closer than 10 feet from Dispenser = NFPA 58 (general) 14. Pump 19. Tanks 2000 Gallons or More [ ] Bypass = NFPA 58 (3-2.10.1) [ ] Check-lock evacuation fittings are capped and not used for bypass inlet = NFPA (general) [ ] If check-lock is being used, remove and replace w/ REGO 7550 valve = NFPA (general) [ ] Control switch nearby = NFPA 58 (3-2.10.1) [ ] Secured to base or frame = NFPA 58 (3-2.10.1) [ ] Remote control switch = NFPA 58 (3-2.10.1) 15. Meter [ ] Supported properly = NFPA 58 (3-2.10.5) [ ] Openings to be labeled VAPOR and LIQUID or color-coded = NFPA 58 (3-2.4.6.e) [ ] Pressure Gauge = NFPA 58 (3-2.4.6.f) [ ] 7 foot extension on relief valves, with proper cover required = NFPA 58 (3-2.4.3.b) 20. Miscellaneous [ ] Combustibles, weeds, dry grass cleared 10 feet from tank = NFPA 58 (3-2.2.6.b) [ ] Class 1, Division 1 electrical wiring and fixtures = NFPA 58 (3-8.2) [ ] Vapor eliminator, vapor connection to tank = NFPA 58 (general) REMARKS: ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ Customer Acknowledgement of Inspection: __________________________________________________ Date:_________________ 800-899-0747 ° 757-499-5977 ° papco.com
© Copyright 2026 Paperzz