TECHNICAL DATA SHEET POSTECH PILE P658 (6 5/8’’) NORMATIVE INFORMATION Postech products are approved by the Canadian Construction Materials Centre (CCMC 13102-R). They were tested on site by an engineering firm recognized by the CCMC. The technical evaluation indicates that Postech products respect the requirements of the CCMC guidelines for augered steel piles. Their performance is equivalent or superior to prescribed NBC 2010 standards. PRODUCT CHARACTERISTICS Physical and Chemical properties Steel grade Conform to CAN/CSA G40.21-350W and/or ASTM-A500 class C Arc Welding Conform to CSA W59-M1989 Hot dip galvanisation Conform to ASTM-A123M Thermal insulation Unique polyurethane foam Standard characteristics Tubing size 168 mm (6 5/8 in) Blade size From 355 to 660 mm (14 to 24 in) Length Standard of 2.1 m and 3 m (7’ and 10’) Tubing thickness 7,1 mm (0.280) Blade thickness 12,7 mm (1/2 in) for diameter from 14 to 26 in Adapter heads Various forms as needed according to the project specifications Extensions Available according to project specifications Allowable mechanical resistance Maximum compressive and tensile [ELS] 700 kN Tube resistance moment 37,3 kN.m Blade assembly 140 kN DESIGN INFORMATION Thermal insulation Postech products are insulated by a process of injecting polyurethane foam in the pile's shaft. The revolutionary insulation system ensures that the inside of the pile is maintained at a temerature that will prevent ice or frost build-up at the base of the pile; providing optimal protection against ground motion using our planet's heat. Screw pile advantages Product and installation is supplied, you only need to mark the spot Can be installed in all climates, weather or ground conditions No excavation usually required, minimal impact to your property Reusable and recyclable, environmentally friendly Bearing capacity Postech products are designed to bear compressive and tension loads through the blade located at the bottom of the shaft. The design of the shaft and the size of the blade depend on the load and on the bearing capacity of the soil. The monitoring of the applied torque on site allows for the confirmation of the bearing capacity of the soil. (See tables on the reverse page.) MANUFACTURER: Pieux Vistech - Postech Screw Piles 525, Parc-Industriel Street, Sherbrooke QC J1C 0J2 Phone: 819.846.4004 1.866.277.4389 Fax: 819.846.0793 www.postech-foundations.com Allowable bearing capacity of soils (kPa) MANUFACTURER: Pieux Vistech - Postech Screw Piles 525, Parc-Industriel Street, Sherbrooke QC J1C 0J2 Phone: 819.846.4004 1.866.277.4389 Fax: 819.846.0793 125 150 175 200 250 ≥300 58 73 88 102 117 145 ≥175 66 55 44 39 33 28 22 17 11 54 45 36 31 27 22 18 14 9 T 86 71 58 50 43 36 29 22 15 C 68 57 46 40 34 29 23 17 12 T 405 mm Ø 355 mm Ø C Blade Blade 109 90 73 63 55 45 36 27 19 C 87 72 58 51 44 36 29 22 15 T 134 111 90 78 67 56 44 34 23 C 107 89 72 62 54 45 35 27 18 T 505 mm Ø Blade Blade 162 134 108 94 81 67 54 41 28 C 129 107 86 75 65 54 43 32 22 T 555 mm Ø Allowable load (kN) 455 mm Ø Blade Allowable bearing capacity of soils (kPa) 69 C 123 98 79 64 54 49 39 30 25 15 T 90 72 58 47 40 36 29 22 18 11 C T C 30.3 34.1 37.9 41.7 18 20 22 191 153 122 99 84 77 61 46 38 23 16 114 91 73 59 50 46 36 27 23 14 P658 155 124 99 81 68 62 50 37 31 19 Blade 140 112 90 73 62 56 45 34 28 17 T 505 mm Ø KN/m3 Lateral loads 95 55 44 36 30 28 22 17 14 8 455 mm Ø Blade Allowable lateral load (kN) ≥ 350 ≥25 76 60 49 42 38 30 23 19 11 T 405 mm Ø 355 mm Ø C Blade Blade Blade T 169 136 108 88 75 68 54 41 34 20 T 156 129 104 91 78 65 52 39 27 279 223 179 145 123 112 89 67 56 33 C 205 164 131 106 90 82 65 49 41 25 T 610 mm Ø Blade 195 162 131 114 98 81 65 49 33 C T 182 151 122 106 92 76 60 46 31 327 261 209 170 144 131 105 78 65 39 C 240 192 153 125 105 96 77 57 48 29 T 660 mm Ø Blade 229 189 153 133 115 95 76 57 39 C 660 mm Ø Blade 84 89 94 99 105 110 115 121 126 4000 4250 4500 4750 5000 5250 5500 5750 6000 73 3500 78 68 3250 3750 63 57 52 47 42 36 31 26 21 15 - 68 66 64 62 60 58 56 54 52 50 48 44 40 35 31 26 21 16 12 7 2 42 39 37 34 31 28 25 22 19 17 14 11 8 5 Compressive 34 32 29 27 24 21 19 16 14 11 8 6 5 4 Tensile Allowable loads (kN) Tensile Allowable loads (kN) Compressive Cohesive soils (clay) 3000 2750 2500 2250 2000 1750 1500 1250 1000 750 Applied torque (lb-foot) Cohesionless soils (silt, sand or gravel) Applied torque versus the allowable loads in compressive and tensile - For cohesionless soils, the safety factor varies from 2.0 to 3.0 in compressive loads and from 2.0 to 2.4 in tensile loads. - For cohesive soils, the safety factor varies from 2.0 à 2.9 in compressive and in tensile loads. - The safety factor for the lateral loads varies from 2.0 to 6.4, for cohesionless and cohesive soils. - If there are any boulders (> 200 mm in diameter) in the granular matrix, the above mentioned capacities will be overstated. In this case, the allowable loads will have to be established on the site using a confirmatory test. TECHNICAL NOTES 231 185 148 120 102 92 74 55 46 28 C 555 mm Ø Allowable load (kN) Soil density 300 175 11 250 150 10 20 125 8 16 100 6 200 75 5 13 50 3 C=compressive T=tensile Compaction index N Blade 610 mm Ø Allowable loads in cohesionless soils (silt, sand or gravel) 75 100 44 50 30 C=compressive T=tensile Undrained shear strength (kPa) Allowable loads in cohesive soils (clay) TECHNICAL DATA SHEET POSTECH PILE P658 (6 5/8’’) www.postech-foundations.com
© Copyright 2026 Paperzz