0063 LOOK TO A LEADER . . . Dedicated to providing excellent product, service and support to meet our customers’ needs and beyond. Roberts-Gordon introduced vacuum assisted, low-intensity, gas-fired radiant heating systems and we remain an industry leader with a complete range of top quality products. With many units installed world-wide, Roberts-Gordon has provided comfortable, economical, and reliable warmth for a variety of satisfied customers. ROBERTS GORDON® gas-fired, low-intensity, radiant heating systems help provide comfort, while facilitating reduced energy consumption up to 50% and more! The principles of radiant energy, can result in considerable energy savings and comfort, while helping to lower your building’s carbon footprint and environmental impact. LESS HEAT STRATIFICATION ROBERTS GORDON® radiant heaters do not blow high temperature heated air that ends up rising to the ceiling. In fact, ROBERTS GORDON® radiant heaters do not heat air. ROBERTS GORDON® radiant heaters reflect and direct radiant energy toward the floor. The radiant energy is in the form of electromagnetic waves that can be directed and reflected like light. These waves travel through the air (not heating it) toward the floor until they strike solid objects. The objects are heated when they absorb the radiant energy. Floors, people and equipment below ROBERTS GORDON® radiant heaters absorb and store heat, then re-radiate heat and warm the air by convection as air passes across the warm objects. Compared to other traditional heating systems, ROBERTS GORDON® radiant heaters use less energy to heat the area at occupant level. In addition, since there is no need for ceiling fans to push heat to the floor, electrical usage can be reduced. REDUCED BUILDING HEAT LOSS Because ROBERTS GORDON® radiant heaters do not introduce high temperature air into the heated space, they generate less heat stratification. Air temperatures at the ceiling are lower than with other heating systems. Lower ceiling temperatures result in reduced heat loss through the roof and lowered building heat loss. Lowered building heat loss means less heat is needed to heat the same space. FLOORS BECOME HEAT RESERVOIRS The sun does not heat the earth’s atmosphere directly; rather its radiant rays heat the earth, people and objects. ROBERTS GORDON® radiant heaters use less fuel than other heating systems because it heats a building and its occupants similar to how the sun heats the earth. With ROBERTS GORDON® radiant heaters, floors and objects become massive secondary heat exchangers. These objects act as heat reservoirs, storing heat, then releasing it into the space by re-radiation and convection to raise space temperature at occupant level. ROBERTS GORDON® Radiant Heaters Help Reduce Energy Bills and Improve Comfort FREE ENERGY RECOVERY In commercial and industrial buildings, rapid air changes and heat loss commonly occur when large doors are opened. As a result, valuable heated air escapes outdoors, wasting money. With air heating, more time and money is required for heat recovery because all the energy burned is used only to heat air, when the heated air is lost, no energy remains in the space. With ROBERTS GORDON® radiant heaters, energy stored in floors and objects is re-used for faster energy recovery in the space, without burning more fuel. GREATER COMFORT AT LOWER TEMPERATURES To obtain fuel savings of up to 50% over conventional heating systems, it is essential to design a radiant system for maximum distribution and comfort. When designing systems for comfort, or reaching the operative temperature (T0), designers need to maximise the mean radiant temperature (MRT) and depress the air temperature (Tair). For example, to reach a perceived comfort of 18° C (65° F), with radiant, the air temperature can be lowered to 12° C (55° F). This helps reduce energy costs! Due to elevated mean radiant space temperature, building occupants feel the same amount of warmth when thermostats are set -15° to -12° C (5° to 10° F) lower with ROBERTS GORDON® radiant heaters than with other heating systems. Lower thermostat setpoint translates into additional energy savings. CLEAN, QUIET, DRAFT-FREE HEAT Since ROBERTS GORDON® radiant heaters quietly warm objects without drafts or blowing air, heated areas are cleaner and quieter. ROBERTS GORDON® radiant heaters spread a gentle blanket of low-intensity, radiant energy that directly warms people, floors and objects in a building. By more effectively delivering heat to the occupied area (floor level), ROBERTS GORDON® radiant heaters offer many benefits that can result in improved conditions and greater fuel savings. MANY DESIGN OPTIONS Design flexibility with a broad range of inputs and tube lengths, helps create even heating and uniform comfort. ROBERTS GORDON® radiant heating systems are custom-engineered and designed to match the specific building plan and space requirements. CORAYVAC® HIGH EFFICIENCY CONDENSING SYSTEM Roberts-Gordon Europe Limited offers CORAYVAC®, a unique radiant heating system with a continuous burners-in-series design. Because it can be designed as a condensing system, CORAYVAC® systems lower exhaust temperatures to put more heat in the space and less wasted through the exhaust. This results in additional efficiency and fuel savings. Proper design, installation, use and maintenance is necessary for optimum performance. This document is intended to assist licensed professionals in the exercise of their professional judgment. CORAYVAC® High Efficiency, Condensing Radiant System Features BURNERS-IN-SERIES DESIGN Located from 3 m to 21.3 m apart, CORAYVAC® burners constantly regulate the air-to-gas mixture to achieve the optimum ratio for clean, efficient combustion. Models are available with inputs of 10, 15, 20, 25 and 30 kW. Features include three-try direct spark ignition, pre-purge, filtered combustion air and cast-iron burner head. REFLECTORS ROBERTS GORDON® deep-dish, continuous aluminium reflectors are shaped to help maximise reflection of the energy emitted by the radiant tube and beamed toward the floor where needed. End caps and continuous reflectors help keep tube convective heat loss to a minimum and help ensure heat exchangers maintain heat. Uniform Heat with CORAYVAC® In-Series Burners Models CRT 20, 25 and 30 meet ECA efficiency requirements. TUBING The CORAYVAC® system utilizes 100 or 150 mm (4" or 6") O.D., 16-gauge, heat treated aluminised steel tubing. The heat created by the burners is drawn through the tubes, which radiate the warm, gentle, radiant energy. VACUUM PUMPS A vacuum pump draws the heat throughout the entire system. It exhausts products of combustion to the outdoors at temperatures typically below 66° C (150° F). Roberts-Gordon offers four pumps for various system sizes and layouts. 750 and 1,100 W pumps are available in single and three phase. Up to twelve heaters can be common vented with one vacuum pump. Design flexibility allows side wall venting, even in large buildings. CONTROLS CORAYVAC® systems can be controlled by an NRG Control. The NRG Control is also capable of controlling other ROBERTS GORDON® radiant and warm air equipment. See the last page for details. COUPLINGS Heat exchanger tubing is connected together with couplings. Roberts-Gordon offers stainless steel and damper couplings. Condensing System - Designed to Condense for Optimum Fuel Saving Efficiency COMBUSTION CHAMBER The aluminised steel CORAYVAC® combustion chamber helps provide corrosion resistance and durability required for condensing systems. Warehouses / Distribution Centres Sports Facilities Machine Shops Distribution Centres Auto Dealerships Vehicle Service Shops Bus Garages Fire Stations Farm Buildings Stores Package/Parcel Hubs Swimming Pools Auto Dealerships Retail Shops Zoos Aircraft Hangars Manufacturing Plants Metal Buildings Loading Docks Auto Body Shops Truck Terminals Parking Ramps Sports Facilities Workshops Showrooms Restaurants Hockey Rinks Animal Confinement Buildings Loading Bays BLACKHEAT® Radiant U-tube, Linear, Double Linear and Multiburner Features Low-Intensity, Unitary Radiant Heaters n Suitable for various applications due to a wide range of burner inputs and tube lengths. n More even heat distribution from vacuum design with uniform tube temperature. n Design flexibility with straight, U-tube or L-configurations. n U-tube heater has reduced wiring costs due to proximity of fan to burner. n Double linear heater has reduced building penetrations due to a single fan. Low-Intensity, Radiant Heating Systems n Custom engineered with a variety of zoning options. n More even heat distribution from vacuum design with uniform tube temperature. n Design flexibility with straight, U-tube or L-configurations. n Reduced building penetrations and installation costs, as a result of multiple burners per pump. n Models meet ECA efficiency requirements. Low-Intensity, Unitary Radiant Heaters for Outdoor Commercial Applications n Bathes customers in warmth keeping them comfortable and extending their stay. n Energy efficient by heating tables, chairs and objects, rather than the air. n Helps maximise profits by extending your facility without the construction expense. n Assists in reducing maintenance costs due to protection of internal burner components against dust and water. n Design flexibility with straight, U-tube or L-configurations. The Energy Saving Control for ROBERTS GORDON® Equipment n Improved fuel savings through self-learning optimisation - the controller varies the heating start-up time to help ensure that the building comes up to the required temperature precisely at the beginning of every programmed “on” period. n Convenience – system can be operated as a full Building Management System (BMS) (free software required) or networked with up to 32 controllers linked together (software not required). n Easy, efficient monitoring – check times, temperatures and status of several controllers from one convenient location. n Energy savings – greater control of controllers from one location helps result in reduced building energy usage. n Secure - coded entry required to access programming features. n Installation flexibility - three remote sensor options available. n Design flexibility - capable of controlling ROBERTS GORDON® warm air and unitary radiant heating products. n Easy to install - built in sensor means no extra wiring. FEATURES OF ROBERTS GORDON® LOW-INTENSITY, GAS-FIRED, RADIANT HEATERS: n Broad range of inputs and tube lengths to fit a variety of building sizes n n n n n n n n n and floor plans. Durable components help provide long equipment life. Ceiling mounting helps keep valuable floor space clear. Detailed installation, commissioning, operation and service manuals to assist in reducing installation and service time. Burner box design with protective enclosure for controls helps minimise exposure to dirt and moisture from combustion air. Deep-dish, parabolically-designed reflectors with end caps help maximise energy reflection and minimise heat loss by convection. Reflectors can be tilted or side reflectors can be added to concentrate heat where needed. Quick fix couplings and hangers provide ease of installation. Natural gas or LPG models available. CE design certified to meet industry standards. Thank You for Your Business! Installation Code and Annual Inspections: All installation and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Roberts-Gordon LLC and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon LLC recommends that a qualified contractor conduct, at a minimum, annual inspections of your ROBERTS GORDON® equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon LLC. Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the Installation, Commissioning, Operation and Service Manual. These products are not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Roberts-Gordon Europe Limited Unit A, Kings Hill Business Park Darlaston Road, Wednesbury West Midlands, WS10 7SH UK Telephone: +44 (0)121 506 7700 Fax: +44 (0)121 506 7701 Service Telephone: +44 (0)121 506 7709 Service Fax: +44 (0)121 506 7702 E-mail: [email protected] E-mail: [email protected] www.rg-inc.com © 2010 Roberts-Gordon LLC Printed in U.S.A. All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval system without written permission of Roberts-Gordon LLC. RGAPBUK 0410 Rev J
© Copyright 2026 Paperzz