MONOCHEM AQUASEAL FORMULA 2000 AQUASEAL FORMULA 2000 is recommended for a wide variety of applications. Because of its incredible repellency to water, oil and stains, AQUASEAL FORMULA 2000 is suitable for maintenance areas, food service areas, kitchen tops and counters, restrooms, patios, and barbeque areas. ADVANTAGES: Reduces cracking, spalling, freeze-thaw damage, chemical degradation, biological growth, efflorescence, and dirt pickup on stone and masonry surfaces. It is a transparent, subsurface vapor-permeable sealer that does not change the appearance of stone or masonry. Resistant to UV and biological degradation. Offers protection against common stains like: coffee, red wine, soda, salad dressing, colored liquids, ketchup, mustard, and spaghetti sauce. SURFACE PREPARATION: To ensure maximum penetration, clean surfaces thoroughly with an appropriate cleaner prior to application. Make sure to remove all surface dirt, oil, grease, curing compounds, and other coatings or contaminants that will inhibit the AQUASEAL FORMULA 2000 from penetrating. All new concrete should be allowed to cure for at least 28 days. The substrate should be inspected to identify improvements or repairs which may be necessary before applying AQUASEAL FORMULA 2000. Prior to application, all the mortar joints should be sound and all cracks larger than hairlines should be filled with a suitable patching material. Alkali, lime or efflorescence on the surface needs to be treated or cleaned with a proper neutralizing agent. If acidic or caustic cleaning agents are used, neutralize the surface and completely wash it to remove any excess residues. Before proceeding with any surface preparation, customers must test the chosen cleaning method to ensure the surface needs are met. Product Qualifications Yes SCAQMD Yes CARB Yes LEED (New Construction) Yes LEED (New Schools / CHPS) Yes AQUASEAL FORMULA 2000 complies with the American Disability Acts recommendation for slip resistance on polished and honed surfaces. APPLICATION: Always conduct a test patch on each surface type before proceeding with the overall application to ensure suitability, desired results, and proper application procedures. STIR WELL BEFORE USING. DO NOT DILUTE OR ALTER THE MATERIAL. AQUASEAL FORMULA 2000 should be applied to horizontal or vertical surfaces in a single, liberal, saturating application to ensure the surface remains wet for a few seconds before penetrating. It can be applied with a low pressure garden-type sprayer, brush, roller or mop application. 4661 Alger Street • Los Angeles, CA 90039 Tel: 818-500-8585 • Fax: 818-502-0818 Manufacturer of U.S. SPECIALTY COATINGS www.monopoleinc.com • Email: [email protected] MONOPOLE INC. UPDATED MAY 2015 Cal Green WATER REPELLENTS 07190 • Granite • Grout • Carpets THERMAL AND MOISTURE PROTECTION TYPICAL PROPERTIES: Active Content (ASTM D 2369) ...........6% Fluorochemical silicone polymer Appearance ...............................................Clear, tan liquid, Dries Clear Flat VOC Level (ASTM 3960).................................................< 15 g/L, low solids Density ......................................................................................8.5 Lbs/Gal Flash Point (ASTM D 3278)...................................................104°C (220°F) Recoat ..........................................................................................1-2 hours Penetration .........................................3/8 inch min, depending on substrate Water/Moisture Vapor Transmission (ASTM E 96) .............................. 100% Accelerated Weathering @2500 hrs (ASTM G 154) .....................No Loss in Water & Oil Repellency Coefficient of Friction (ASTM C1028-07) .......................Dry: 0.86, Wet: 0.69 SurfaceAppearance ..................................................................No Change 7 BASIC USES: AQUASEAL FORMULA 2000 can be used horizontally or vertically for indoor and outdoor applications. It is designed to provide a durable, subsurface, transparent protective barrier against oil, water and other stains on porous mineral surfaces such as stone and tile. AQUASEAL FORMULA 2000 is a penetrating sealer for: • Marble • Grout • Leather MADE IN U.S.A. ITEM NO. 2000 AQUASEAL FORMULA 2000 is a clear flat penetrating, water base emulsion sealer that repels water and oil borne stains. Unlike waxes, acrylics, urethanes or other type of film forming treatments, AQUASEAL FORMULA 2000 penetrates deep into porous materials. It physically and chemically bonds to the substrate creating a long lasting fluorochemical barrier that “locks out” oils, water, and soil. This barrier forces liquids to bead on surface, allowing them to be picked up easier which helps prevent staining. • Concrete Blocks • Stucco • Unglazed Tile • Stone • Brick • Wood • Fabries SINCE 1975 U.S. SPECIALTY COATINGS Repellent for Water, Oil, Stain, Alcohol & Soil PRODUCT DESCRIPTION: TECHNICAL BULLETIN On porous substrates, two applications of AQUASEAL FORMULA 2000 will provide superior protection. Apply the second coat immediately after the first coat has penetrated (a few minutes after the first coat appears dry). Apply uniformly and avoid over application. Surface pools or puddles should be removed by back rolling or brooming until AQUASEAL FORMULA 2000 completely penetrates into the pores. Failure to do so may result in a blotchy and/or glistening appearance. Because AQUASEAL FORMULA 2000 is a penetrating sealer, it can be painted over with oil or water based paints. Allow the sealed surface to dry for a minimum of 24 hours before top coating. COVERAGE RATES, per gallon (Approximate) ALWAYS TEST Concrete GFRC 200-400 sq/feet Precast Panels 100-300 sq/feet Pavers 100-300 sq/feet Cast-in-Place 100-300 sq/feet Brick 100-300 sq/feet Block 70-100 sq/feet Block, CMU 80-100 sq/feet Split Face 60-80 sq/feet Unglazed Tile 100-300 sq/feet Grout 100-300 sq/feet Granite Polished 300-600sq/feet Unpolished 300-600 sq/feet Marble Polished 400-600 sq/feet Limestone Travertine Unpolished 300-500 sq/feet Slate Unpolished 300-500sq/feet Sandstone Unpolished 200-400 sq/feet Fired Clay Brick Unglazed Tile Terra Cotta Mexican Pavers 250-400 sq/feet 250-400 sq/feet 250-400 sq/feet 250-400 sq/feet Wood Unsealed 150-200 sq/feet Fabries Leather Carpets 100-200 sq/feet 100-200 sq/feet AQUASEAL FORMULA 2000 will dry to touch in 20-30 minutes and can be walked on in 2-4 hours. LIMITATIONS: AQUASEAL FORMULA 2000 is not recommended for non-porous substrates. The surface and air temperature should not exceed 100°F. (38°C) at the time of application. Do not apply in windy conditions. It is not recommended for below grade application or for use under hydrostatic pressure. Doesn’t stop bleeding of tannin acid from fresh redwood, pine or cedar. MAINTENANCE: To remove stains from a surface treated with AQUASEAL FORMULA 2000 use water, soapy water, or a mild detergent solution; rinse and allow to dry. Do not allow stains or scuffs to remain on the surface for extended periods of time to avoid discoloration. For maximum protection against stains, it is recommended that the surface be treated periodically. The amount of time between re-treatment will depend on the traffic exposure, traffic type, number of cleaning cycles, type of stains, and the amount of soils or stains. PERFORMANCE RESULTS ON BRICK STAIN Ketchup Mustard Red Wine Spaghetti Sauce Coffee UNTREATED Light Stain Light Stain Light Stain Light Stain Light Stain SHELF LIFE: AQUASEAL FORMULA 2000 can be used for up to two years in a well protected storage. STORAGE: Store in temperatures between 40-80°F. (4-8°C.). Protect material from freezing. Also keep the container tightly closed. TREATED No Stain No Stain No Stain No Stain No Stain PERFORMANCE RESULTS ON CONCRETE STAIN Motor Oil Power Steering Fluid Transmission Fluid Hydraulic Fluid UNTREATED Heavy Stain Heavy Stain Heavy Stain Heavy Stain TREATED No Stain No Stain No Stain Small Light Stain CLEAN UP: Thoroughly rinse equipment and tools with clean water, soapy water, or mild detergents after use. PACKAGING: AQUASEAL FORMULA 2000 is packaged in 1-Gallon Cans and 5-Gallon Pails. WARRANTY INFORMATION: MONOPOLE believes that the information in this publication is an accurate description of the typical characteristics and/or uses of the product or products. It is your responsibility to thoroughly test the product in your specific application to determine its safety and performance capabilities. Since use of this product is beyond our control, MONOPOLE, INC. cannot assume any risk or liability for results obtained when not used according to our specifications and directions. Unless MONOPOLE provides a specifically written statement of fitness for a particular use, MONOPOLE'S sole warranty is that the product will meet its current sales specifications. MONOPOLE disclaims any other expressed or implied warranties, including the warranty of merchantability and fitness for use. Your exclusive remedy and MONOPOLE'S sole liability for breach of warranty is limited to a refund of the purchase price or replacement of any product proven to be defective. In no event shall the seller be liable for any loss of profits or other consequential damages, including labor charges.
© Copyright 2024 Paperzz