Drywall Grid System Advantages Drywall & ShortSpan Grid Systems Armstrong Drywall Grid System Traditional framing system Fast and Easy Hanger Wire Main Beam Channel Cross Tee Track • Engineered to maintain precise module spacing through manufactured rout locations. This grid system saves time, labor and money. 2-18 • Track and channel construction requires labor-intensive cutting, tying and spacing. For more information call 1 877 ARMSTRONG Armstrong Drywall Grid System Hanger Wire Traditional Framing System Hanger Wire Drywall Grid Main Beam Perimeter Treatment Carrying Channel C-Channel Hat Track Drywall Grid Cross Tee Gypsum Board Gypsum Board Single layer/plane Layered suspension/components • Suspended drywall grid system eliminates the need for hat track and carrying channel • Simple stab and click installation eliminates labor-intensive cutting and tying • Drywall grid system installs in the same time it takes to install an acoustical grid system • ScrewStop feature offers more consistent, positive screw attachment of gypsum board • Manufactured rout locations eliminate the need to measure and ensures consistent module spacing • 51 main beam routs and 7 cross tees engineered to eliminate time consuming field modifications for type “F” fixtures • Maximize ceiling height with single layer framing — important in low clearance installations 2-19 For more information call 1 877 ARMSTRONG Armstrong Drywall Grid System Traditional Framing System Stud & Track to structure Hanger Wire Drywall Grid System Exposed Tee Grid System Gypsum Board Perimeter Treatment Stud & Track Exposed Tee Grid System Gypsum Board Wall Angle Drywall Corner Bead Hanger Wire Stud & Track to structure Exposed Tee Grid System Drywall Grid System Perimeter Treatment Gypsum Board Exposed Tee Grid System Wall Angle Drywall Corner Bead • Drywall and acoustical components interconnect for faster, easier ceiling transitions • Suspended by hanger wire — eliminates additional stud and track framing in the plenum 2-20 For more information call 1 877 ARMSTRONG Stud & Track Armstrong Drywall Grid System Traditional Framing System Hanger Wire DW90 Exposed Tee Grid System Stud & Track to structure Angle Molding Drywall Grid System Gypsum Board Drywall Corner Bead Exposed Tee Grid System Wall Angle • Suspended by hanger wire — eliminates additional stud and track framing in the plenum 2-21 For more information call 1 877 ARMSTRONG Gypsum Board Estimating Material Drywall & ShortSpan Grid Systems Item number DRYWALL/STUCCO GRID MAIN BEAM HD8901 HD8906/HD8906G90 HD8906F08/HD8906F16 SHORTSPAN SS7708 SS7710 SS7712 SS7714 DRYWALL/STUCCO GRID 1-1/2″″ FACE CROSS TEES XL8947P/XL8947PG90** XL8945P/XL8945PG90 XL7936G90 XL8925/XL8925G90** XL8926/XL8926G90 XL7918** DRYWALL/STUCCO GRID 15/16″″ FACE CROSS TEES XL7341/XL8341 Length Pcs/Ctn. LF/Ctn. Lbs./Ctn. Area of ceiling at on center spacing 16″″ 144″ 144″ 144″ 20 12 12 240 144 144 71 53 53 96″ 120″ 144″ 168″ 12 12 12 12 96 120 144 168 29 37 44 51 50″ 48″ 36″ 26″ 24″ 14″ 36 36 36 36 36 36 150 144 108 78 72 42 56 52 39 28 26 14 48″ 60 240 71 24″″ 36″″ 48″″ 480 720 960 288 432 576 varies with radius varies varies varies varies 8″″ 100 96 72 with with with with 16″″ 200 192 144 24″″ 300 288 216 16″″ 320 24″″ 480 48 ** Dimensions are nominal. For clips and accessories, see pages 2-14 through 2-17. 2-22 For more information call 1 877 ARMSTRONG room room room room dimension dimension dimension dimension 50″″ 1000 600 sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. Estimating Material Drywall & ShortSpan Grid Systems Estimating Lineal Feet of Grid Based on Square Footage of Ceiling Item number REVERSE MOLDINGS 7857 7858 Length Pcs/Ctn. LF/Ctn. Lbs./Ctn. 120″ 120″ 30 20 360 240 51 67 DRYWALL UNHEMMED CHANNEL MOLDING 7838 120″ 20 200 36 DRYWALL ANGLE MOLDING KAM-12 KAM-10 LAM-12 144″ 120″ 144″ 30 30 30 360 300 360 58 49 58 On Center Spacing of Component 8″ 12″ 16″ 20″ 24″ 30″ 36″ 48″ 60″ Percent of Square Footage 108% 100% 76% 60% 50% 40% 33% 25% 20% Example calculation based on 5,100 SF ceiling: Main beam at 48″ O.C. 5,100 SF x .25 = 1,275 LF 1,275 LF ÷ 144 LF/Ctn = 9 cartons needed Cross tee at 16″ O.C. 5,100 SF x .76 = 3,876 LF 3,876 LF ÷ 144 LF/Ctn = 27 cartons needed 2-23 For more information call 1 877 ARMSTRONG Installation Cost Comparison Drywall & ShortSpan Grid Systems The following chart compares installed costs of an Armstrong Grid System versus traditional cold rolled channel installation. To obtain an electronic copy of the cost comparison, contact TechLine at 1 877 ARMSTRONG. Drywall Installed Cost Comparison Edit the outlined entries as required Area (SF) Plenum Depth (in.) Cross Furring Spacing (in.) Carrying Channel (16 gauge Black Iron) & Metal Furring (Hat Channel) Armstrong Drywall Grid System Black Iron Hat Channel LF @ LF @ /LF /LF = = Main Tee Cross Tee LF LF @ @ /LF /LF = = 9 Gauge Wire 18 Gauge Wire LF @ LF @ /LF /LF = = 12 Gauge Wire LF @ /LF = TOTAL MATERIAL COST Labor sf / day = TOTAL MATERIAL COST Labor @ = sf / day Total Days @ Total Days Total Labor Cost = Total Labor Cost = Total Job Cost* = Total Job Cost* = COST PER SQUARE FOOT = COST PER SQUARE FOOT = SAVINGS OF $ = % USING ARMSTRONG DRYWALL GRID SYSTEM *Does not include wall angle. 2-24 For more information call 1 877 ARMSTRONG
© Copyright 2024 Paperzz