Drywall Grid System Advantages

Drywall Grid System Advantages
Drywall & ShortSpan Grid Systems
Armstrong Drywall Grid System
Traditional framing system
Fast and Easy
Hanger Wire
Main Beam
Channel
Cross Tee
Track
• Engineered to maintain precise module spacing
through manufactured rout locations. This grid
system saves time, labor and money.
2-18
• Track and channel construction requires
labor-intensive cutting, tying and spacing.
For more information call 1 877 ARMSTRONG
Armstrong Drywall Grid System
Hanger Wire
Traditional Framing System
Hanger Wire
Drywall Grid
Main Beam
Perimeter
Treatment
Carrying Channel
C-Channel
Hat Track
Drywall Grid
Cross Tee
Gypsum
Board
Gypsum
Board
Single layer/plane
Layered suspension/components
• Suspended drywall grid system eliminates the need for
hat track and carrying channel
• Simple stab and click installation eliminates labor-intensive
cutting and tying
• Drywall grid system installs in the same time it takes to
install an acoustical grid system
• ScrewStop feature offers more consistent, positive screw
attachment of gypsum board
• Manufactured rout locations eliminate the need to measure
and ensures consistent module spacing
• 51 main beam routs and 7 cross tees engineered to eliminate
time consuming field modifications for type “F” fixtures
• Maximize ceiling height with single layer framing — important
in low clearance installations
2-19
For more information call 1 877 ARMSTRONG
Armstrong Drywall Grid System
Traditional Framing System
Stud & Track
to structure
Hanger Wire
Drywall Grid
System
Exposed Tee
Grid System
Gypsum
Board
Perimeter
Treatment
Stud & Track
Exposed Tee
Grid System
Gypsum
Board
Wall Angle
Drywall
Corner Bead
Hanger Wire
Stud & Track
to structure
Exposed Tee Grid System
Drywall Grid
System
Perimeter
Treatment
Gypsum
Board
Exposed Tee
Grid System
Wall
Angle
Drywall
Corner Bead
• Drywall and acoustical components interconnect
for faster, easier ceiling transitions
• Suspended by hanger wire — eliminates additional
stud and track framing in the plenum
2-20
For more information call 1 877 ARMSTRONG
Stud & Track
Armstrong Drywall Grid System
Traditional Framing System
Hanger Wire
DW90
Exposed
Tee Grid
System
Stud & Track
to structure
Angle Molding
Drywall Grid
System
Gypsum
Board
Drywall
Corner Bead
Exposed Tee
Grid System
Wall
Angle
• Suspended by hanger wire — eliminates additional
stud and track framing in the plenum
2-21
For more information call 1 877 ARMSTRONG
Gypsum
Board
Estimating Material
Drywall & ShortSpan Grid Systems
Item number
DRYWALL/STUCCO
GRID MAIN BEAM
HD8901
HD8906/HD8906G90
HD8906F08/HD8906F16
SHORTSPAN
SS7708
SS7710
SS7712
SS7714
DRYWALL/STUCCO GRID
1-1/2″″ FACE CROSS TEES
XL8947P/XL8947PG90**
XL8945P/XL8945PG90
XL7936G90
XL8925/XL8925G90**
XL8926/XL8926G90
XL7918**
DRYWALL/STUCCO GRID
15/16″″ FACE CROSS TEES
XL7341/XL8341
Length Pcs/Ctn. LF/Ctn. Lbs./Ctn.
Area of ceiling at on center spacing
16″″
144″
144″
144″
20
12
12
240
144
144
71
53
53
96″
120″
144″
168″
12
12
12
12
96
120
144
168
29
37
44
51
50″
48″
36″
26″
24″
14″
36
36
36
36
36
36
150
144
108
78
72
42
56
52
39
28
26
14
48″
60
240
71
24″″
36″″
48″″
480
720
960
288
432
576
varies with radius
varies
varies
varies
varies
8″″
100
96
72
with
with
with
with
16″″
200
192
144
24″″
300
288
216
16″″
320
24″″
480
48
** Dimensions are nominal.
For clips and accessories, see pages 2-14 through 2-17.
2-22
For more information call 1 877 ARMSTRONG
room
room
room
room
dimension
dimension
dimension
dimension
50″″
1000
600
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
Estimating Material
Drywall & ShortSpan Grid Systems
Estimating Lineal Feet of Grid
Based on Square Footage of Ceiling
Item number
REVERSE MOLDINGS
7857
7858
Length
Pcs/Ctn.
LF/Ctn.
Lbs./Ctn.
120″
120″
30
20
360
240
51
67
DRYWALL UNHEMMED
CHANNEL MOLDING
7838
120″
20
200
36
DRYWALL ANGLE MOLDING
KAM-12
KAM-10
LAM-12
144″
120″
144″
30
30
30
360
300
360
58
49
58
On Center Spacing
of Component
8″
12″
16″
20″
24″
30″
36″
48″
60″
Percent of
Square Footage
108%
100%
76%
60%
50%
40%
33%
25%
20%
Example calculation based on 5,100 SF ceiling:
Main beam at 48″ O.C.
5,100 SF x .25 = 1,275 LF
1,275 LF ÷ 144 LF/Ctn = 9 cartons needed
Cross tee at 16″ O.C.
5,100 SF x .76 = 3,876 LF
3,876 LF ÷ 144 LF/Ctn = 27 cartons needed
2-23
For more information call 1 877 ARMSTRONG
Installation Cost Comparison
Drywall & ShortSpan Grid Systems
The following chart compares installed costs of an Armstrong Grid System versus traditional cold
rolled channel installation. To obtain an electronic copy of the cost comparison, contact TechLine
at 1 877 ARMSTRONG.
Drywall Installed Cost Comparison
Edit the outlined entries as required
Area (SF)
Plenum Depth (in.)
Cross Furring Spacing (in.)
Carrying Channel (16 gauge Black Iron)
& Metal Furring (Hat Channel)
Armstrong Drywall Grid System
Black Iron
Hat Channel
LF @
LF @
/LF
/LF
=
=
Main Tee
Cross Tee
LF
LF
@
@
/LF
/LF
=
=
9 Gauge Wire
18 Gauge Wire
LF @
LF @
/LF
/LF
=
=
12 Gauge Wire
LF
@
/LF
=
TOTAL MATERIAL COST
Labor
sf / day
=
TOTAL MATERIAL COST
Labor
@
=
sf / day
Total Days
@
Total Days
Total Labor Cost
=
Total Labor Cost
=
Total Job Cost*
=
Total Job Cost*
=
COST PER SQUARE FOOT
=
COST PER SQUARE FOOT
=
SAVINGS OF
$
=
%
USING ARMSTRONG DRYWALL GRID SYSTEM
*Does not include wall angle.
2-24
For more information call 1 877 ARMSTRONG