TYPE APPROVAL CERTIFICATE Certificate No: TAE00000DR This is to certify: That the Data transmission cables and systems with type designation(s) Type RG 58 Marine SHF1 without armour, Type RG213 Marine SHF1 without armour, Type RG214 Marine SHF1 without armour Issued to NEK Kabel AS LØRENSKOG, Norway is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application : Coaxial cable 50 Ohm. Unarmoured. Flame retardant in bunch Cat C. Halogen free. Low smoke. Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until 2018-06-30. Issued at Høvik on 2014-05-19 for DNV GL DNV GL local station: Milan Approval Engineer: Ivar Bull Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2015-05 © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. www.dnvgl.com Page 1 of 3 Job Id: 262.1-016927-1 Certificate No: TAE00000DR Product description Type RG 58 Marine SHF1 without armour, Type RG213 Marine SHF1 without armour, Type RG214 Marine SHF1 without armour Type RG 58 Marine SHF1 without armour Construction Inner Conductor Tinned Copper 19x 0,18mm Insulation Low density polyethylene Shield Aluminium+Polyester+Aluminium tape Outer conductor Tinned copper braid Sheath SHF1 Outer diameter 8,0+0,2 mm Type RG213 Marine SHF1 without armour Construction Inner Conductor Plain copper 7x0,75mm Insulation Low density polyethylene Shield Aluminium+Polyester+Aluminium tape Outer conductor Tinned copper braid Sheath SHF1 Outer diameter 10,30+0,18 mm Type RG214 Marine SHF1 without armour Construction Inner Conductor Silvered copper 7x0,75mm Insulation Low density polyethylene Shield Aluminium+Polyester+Aluminium tape 1st outer Silvered copper braid conductor 2nd outer Silvered copper braid conductor Sheath SHF1 Outer diameter 10,80+0,18mm For electrical data and transmission properties, please refer to relevant datasheets. Manufactured by DNV Id. 10310952 Application/Limitation The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. Type Approval documentation Datasheet Type RG 58 Marine MIL -C17F SHF1 without armour , dated May 22 2013 Type RG213 Marine M17/074 SHF1 without armour , dated May 22 2013 Type RG214 Marine M17/75 SHF1 without armour , dated May 22 2013 Test reports: 2014.2301/05 dated 2014.2301/09 dated Form code: TA 1411a Revision: 2015-05 23.01.2014 23.01.2014 www.dnvgl.com Page 2 of 3 Job Id: 262.1-016927-1 Certificate No: TAE00000DR 2014.2301/11 dated 23.01.2014 Tests carried out Standard IEC 60096-0-1 Ed 3 Release 2012 IEC 60092-359 1999-08 IEC 60332-3-24 2009-02 IEC 60754-2 2011-11 IEC 61034-1/2 2013-07 2013-09 General description Radio frequency cables Part 0-1: Guide to the design of detail specifications Coaxial cables Sheathing materials for shipboard power and telecommunication cables Tests on electric and optical fibre cables under fire conditions – Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category C Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity Measurement of smoke density of cables burning under defined conditions – Test apparatus, procedure and requirements Limitation Bunch test Category C Halogen free: pH > 4,3 Conductivity < 10μS/mm Low smoke: Light transmittance >60% Marking of product NEK kabel –RG 58 CU Marin SHF1 - DNV – IEC 60332-3-24 – <batch no.> - <meter marking> NEK kabel –RG 58 CU Marin SHF1 - DNV – IEC 60332-3-24 – <batch no.> - <meter marking> NEK kabel – RG 214 U Marin SHF1 – DNV – IEC 60332-3-24 – <batch no.> – <meter marking> Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the periodical assessment are: · · · · · · Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routine Tests (RT) checked (if RT- and PST-test reports are not available, tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensure traceability between manufacturer's product type marking and Type Approval Certificate. Periodical assessment shall be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 3 of 3 DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-13350 This is to certify that the Data transmission cables and systems with type designation(s) Type RG 58 Marin SHF1 Armoured, Type RG213 Marin SHF1 Armoured, Type RG214 Marin SHF1 Armoured Manufactured by NEK Kabel AS LØRENSKOG, Norway is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC 60332-3-24 (2009-02) IEC 60754-1 (2011-11) IEC61034-1/2 (2005-04/2005-04) Application Coaxial cable 50 Ohm. Armoured. Flame retardant in bunch Cat C. Halogen free. Low smoke. Type Type RG 58 Marin SHF1 Armoured Type RG213 Marin SHF1 Armoured Type RG214 Marin SHF1 Armoured Voltage (kV) Temp. class (°C) This Certificate is valid until 2018-06-30. Issued at Høvik on 2014-05-19 for Det Norske Veritas AS DNV local station: Milan Approval Engineer: Ivar Bull Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: December 2012 www.dnv.com Page 1 of 3 Certificate No.: E-13350 827.50 File No.: Job Id.: 262.1-016927-1 Product description Type RG 58 MIL-C17F SHF1 Armoured Type RG213 M17/074 SHF1 Armoured Type RG214 M17/75 SHF1 Armoured Type RG 58 MIL-C17F SHF1 Armoured Construction Inner Conductor Tinned Copper 19x 0,18mm Insulation Low density polyethylene Aluminium+Polyester+Aluminium tape Shield Outer conductor Tinned copper braid Inner Sheath SHF1 Armour Galvanized steel wire braid 2nd sheath SHF1 Outer diameter 8,0 + 0,2 mm Type RG213 M17/074 SHF1 Armoured Construction Inner Conductor Plain copper 7x0,75mm Low density polyethylene Insulation Shield Aluminium+Polyester+Aluminium tape Outer conductor Plain copper braid Inner Sheath SHF1 Armour Galvanized steel wire braid 2nd sheath SHF1 Outer diameter 13,7 + 0,4 mm RG214 M17/75 SHF1 Armoured Construction Inner Conductor Silvered copper 7x 0,75 mm Insulation Low density polyethylene Shield Aluminium+Polyester+Aluminium tape 1st outer conductor Silver coated copper 2nd braid Silver coated copper Inner outer conductor SHF1 Armour Galvanized steel wire braid 2nd sheath SHF1 Outer diameter 14,80+0,4mm For electrical data and transmission properties, please refer to relevant datasheets. Manufactured by DNV Id. 10310952 Application/Limitation The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: December 2012 www.dnv.com Page 2 of 3 Certificate No.: E-13350 827.50 File No.: Job Id.: 262.1-016927-1 Type Approval documentation Datasheet Type RG58 Marin SHF1 Armoured dated May 22 2013 Type RG213 Marin SHF1 Armoured dated May 22 2013 Type RG214 Marin SHF1 Armoured dated May 22 2013 Test reports: 2014.2301/06 2014.2301/10 2014.2301/12 dated dated dated 23.01.2014 23.01.2014 23.01.2014 Tests carried out Standard IEC 60096-0-1 Ed 3 Release 2012 IEC 60092-359 1999-08 IEC 60332-3-24 2009-02 IEC 60754-2 2011-11 IEC 61034-1/2 2005-04 General description Radio frequency cables Part 0-1: Guide to the design of detail specifications Coaxial cables Sheathing materials for shipboard power and telecommunication cables Tests on electric and optical fibre cables under fire conditions – Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category C Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity Measurement of smoke density of cables burning under defined conditions – Test apparatus, procedure and requirements Limitation Bunch test Category C Halogen free: pH > 4,3 Conductivity < 10μS/mm Low smoke Light transmittance >60% Marking of product NEK kabel – RG 58 CU Marine SHF1 Armoured – DNV – IEC 60332-3-24 – <batch no.> – <meter marking> NEK kabel – RG 213 U Marine SHF1 Armoured - DNV – IEC 60332-3-24 – <batch no.> – <meter marking> NEK kabel – RG214 U Marine SHF1 Armoured - DNV – IEC 60332-3-24 – <batch no.> – <meter marking> Certificate Retention Survey The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: · · · · · · Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routine Tests (RT) checked (if RT- and PST-test reports are not available, tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensure traceability between manufacturer's product type marking and Type Approval Certificate. Survey shall be performed at least every second year. END OF CERTIFICATE DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: December 2012 www.dnv.com Page 3 of 3
© Copyright 2026 Paperzz