type approval certificate

TYPE APPROVAL CERTIFICATE
Certificate No:
TAE00000DR
This is to certify:
That the Data transmission cables and systems
with type designation(s)
Type RG 58 Marine SHF1 without armour, Type RG213 Marine SHF1 without armour, Type
RG214 Marine SHF1 without armour
Issued to
NEK Kabel AS
LØRENSKOG, Norway
is found to comply with
Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske
Veritas' Offshore Standards
Application :
Coaxial cable 50 Ohm. Unarmoured.
Flame retardant in bunch Cat C. Halogen free. Low smoke.
Product(s) approved by this certificate is/are accepted for installation on all vessels classed
by DNV GL.
This Certificate is valid until 2018-06-30.
Issued at Høvik on 2014-05-19
for DNV GL
DNV GL local station: Milan
Approval Engineer: Ivar Bull
Marit Laumann
Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
Form code: TA 1411a
Revision: 2015-05
© DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.
www.dnvgl.com
Page 1 of 3
Job Id:
262.1-016927-1
Certificate No: TAE00000DR
Product description
Type RG 58 Marine SHF1 without armour,
Type RG213 Marine SHF1 without armour,
Type RG214 Marine SHF1 without armour
Type RG 58 Marine SHF1 without armour
Construction
Inner Conductor
Tinned Copper 19x 0,18mm
Insulation
Low density polyethylene
Shield
Aluminium+Polyester+Aluminium tape
Outer conductor
Tinned copper braid
Sheath
SHF1
Outer diameter
8,0+0,2 mm
Type RG213 Marine SHF1 without armour
Construction
Inner Conductor
Plain copper 7x0,75mm
Insulation
Low density polyethylene
Shield
Aluminium+Polyester+Aluminium tape
Outer conductor
Tinned copper braid
Sheath
SHF1
Outer diameter
10,30+0,18 mm
Type RG214 Marine SHF1 without armour
Construction
Inner Conductor
Silvered copper 7x0,75mm
Insulation
Low density polyethylene
Shield
Aluminium+Polyester+Aluminium tape
1st outer
Silvered copper braid
conductor
2nd outer
Silvered copper braid
conductor
Sheath
SHF1
Outer diameter
10,80+0,18mm
For electrical data and transmission properties, please refer to relevant datasheets.
Manufactured by
DNV Id. 10310952
Application/Limitation
The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to
limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures.
Type Approval documentation
Datasheet
Type RG 58 Marine MIL -C17F SHF1 without armour , dated May 22 2013
Type RG213 Marine M17/074 SHF1 without armour , dated May 22 2013
Type RG214 Marine M17/75 SHF1 without armour , dated May 22 2013
Test reports:
2014.2301/05 dated
2014.2301/09 dated
Form code: TA 1411a
Revision: 2015-05
23.01.2014
23.01.2014
www.dnvgl.com
Page 2 of 3
Job Id:
262.1-016927-1
Certificate No: TAE00000DR
2014.2301/11 dated
23.01.2014
Tests carried out
Standard
IEC 60096-0-1
Ed 3
Release
2012
IEC 60092-359
1999-08
IEC 60332-3-24
2009-02
IEC 60754-2
2011-11
IEC 61034-1/2
2013-07
2013-09
General description
Radio frequency cables
Part 0-1: Guide to the design of detail
specifications
Coaxial cables
Sheathing materials for shipboard power
and telecommunication cables
Tests on electric and optical fibre cables
under fire conditions – Part 3-24: Test for
vertical flame spread of vertically-mounted
bunched wires or cables – Category C
Test on gases evolved during combustion
of materials from cables - Part 2:
Determination of acidity (by pH
measurement) and conductivity
Measurement of smoke density of cables
burning under defined conditions –
Test apparatus, procedure and
requirements
Limitation
Bunch test
Category C
Halogen free:
pH > 4,3
Conductivity <
10μS/mm
Low smoke: Light
transmittance >60%
Marking of product
NEK kabel –RG 58 CU Marin SHF1 - DNV – IEC 60332-3-24 – <batch no.> - <meter marking>
NEK kabel –RG 58 CU Marin SHF1 - DNV – IEC 60332-3-24 – <batch no.> - <meter marking>
NEK kabel – RG 214 U Marin SHF1 – DNV – IEC 60332-3-24 – <batch no.> – <meter marking>
Periodical assessment
The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is
complied with and that no alterations are made to the product design or choice of materials.
The main elements of the periodical assessment are:
·
·
·
·
·
·
Inspection on factory samples, selected at random from the production line (where practicable)
Results from Production Sample Tests (PST) and Routine Tests (RT) checked
(if RT- and PST-test reports are not available, tests according to PST and RT to be carried out)
Review of type approval documentation
Review of possible change in design, materials and performance
Ensure traceability between manufacturer's product type marking and Type Approval Certificate.
Periodical assessment shall be performed at least every second year.
END OF CERTIFICATE
Form code: TA 1411a
Revision: 2015-05
www.dnvgl.com
Page 3 of 3
DET NORSKE VERITAS
TYPE APPROVAL CERTIFICATE
CERTIFICATE NO. E-13350
This is to certify that the
Data transmission cables and systems
with type designation(s)
Type RG 58 Marin SHF1 Armoured, Type RG213 Marin SHF1 Armoured, Type RG214 Marin SHF1 Armoured
Manufactured by
NEK Kabel AS
LØRENSKOG, Norway
is found to comply with
Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore
Standards
IEC 60332-3-24 (2009-02)
IEC 60754-1 (2011-11)
IEC61034-1/2 (2005-04/2005-04)
Application
Coaxial cable 50 Ohm. Armoured.
Flame retardant in bunch Cat C. Halogen free. Low smoke.
Type
Type RG 58 Marin SHF1 Armoured
Type RG213 Marin SHF1 Armoured
Type RG214 Marin SHF1 Armoured
Voltage (kV)
Temp. class (°C)
This Certificate is valid until 2018-06-30.
Issued at Høvik on 2014-05-19
for Det Norske Veritas AS
DNV local station: Milan
Approval Engineer: Ivar Bull
Marit Laumann
Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such
person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum
compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers,
employees, agents and any other acting on behalf of Det Norske Veritas.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: December 2012
www.dnv.com
Page 1 of 3
Certificate No.: E-13350
827.50
File No.:
Job Id.:
262.1-016927-1
Product description
Type RG 58 MIL-C17F SHF1 Armoured
Type RG213 M17/074 SHF1 Armoured
Type RG214 M17/75 SHF1 Armoured
Type RG 58 MIL-C17F SHF1 Armoured
Construction
Inner Conductor
Tinned Copper 19x 0,18mm
Insulation
Low density polyethylene
Aluminium+Polyester+Aluminium tape
Shield
Outer conductor
Tinned copper braid
Inner Sheath
SHF1
Armour
Galvanized steel wire braid
2nd sheath
SHF1
Outer diameter
8,0 + 0,2 mm
Type RG213 M17/074 SHF1 Armoured
Construction
Inner Conductor
Plain copper 7x0,75mm
Low density polyethylene
Insulation
Shield
Aluminium+Polyester+Aluminium tape
Outer conductor
Plain copper braid
Inner Sheath
SHF1
Armour
Galvanized steel wire braid
2nd sheath
SHF1
Outer diameter
13,7 + 0,4 mm
RG214 M17/75 SHF1 Armoured
Construction
Inner Conductor
Silvered copper 7x 0,75 mm
Insulation
Low density polyethylene
Shield
Aluminium+Polyester+Aluminium tape
1st outer conductor
Silver coated copper
2nd braid
Silver coated copper
Inner outer conductor SHF1
Armour
Galvanized steel wire braid
2nd sheath
SHF1
Outer diameter
14,80+0,4mm
For electrical data and transmission properties, please refer to relevant datasheets.
Manufactured by
DNV Id. 10310952
Application/Limitation
The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation
along Bunches of Cables or Wires) are fulfilled without any additional measures.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: December 2012
www.dnv.com
Page 2 of 3
Certificate No.: E-13350
827.50
File No.:
Job Id.:
262.1-016927-1
Type Approval documentation
Datasheet
Type RG58 Marin SHF1 Armoured dated May 22 2013
Type RG213 Marin SHF1 Armoured dated May 22 2013
Type RG214 Marin SHF1 Armoured dated May 22 2013
Test reports:
2014.2301/06
2014.2301/10
2014.2301/12
dated
dated
dated
23.01.2014
23.01.2014
23.01.2014
Tests carried out
Standard
IEC 60096-0-1
Ed 3
Release
2012
IEC 60092-359
1999-08
IEC 60332-3-24
2009-02
IEC 60754-2
2011-11
IEC 61034-1/2
2005-04
General description
Radio frequency cables
Part 0-1: Guide to the design of detail
specifications
Coaxial cables
Sheathing materials for shipboard power and
telecommunication cables
Tests on electric and optical fibre cables under
fire conditions – Part 3-24: Test for vertical flame
spread of vertically-mounted bunched wires or
cables – Category C
Test on gases evolved during combustion of
materials from cables - Part 2: Determination of
acidity (by pH measurement) and conductivity
Measurement of smoke density of cables
burning under defined conditions –
Test apparatus, procedure and requirements
Limitation
Bunch test
Category C
Halogen free:
pH > 4,3
Conductivity < 10μS/mm
Low smoke
Light transmittance >60%
Marking of product
NEK kabel – RG 58 CU Marine SHF1 Armoured – DNV – IEC 60332-3-24 – <batch no.> – <meter marking>
NEK kabel – RG 213 U Marine SHF1 Armoured - DNV – IEC 60332-3-24 – <batch no.> – <meter marking>
NEK kabel – RG214 U Marine SHF1 Armoured - DNV – IEC 60332-3-24 – <batch no.> – <meter marking>
Certificate Retention Survey
The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type approval is complied with and
that no alterations are made to the product design or choice of materials.
The main elements of the survey are:
·
·
·
·
·
·
Inspection on factory samples, selected at random from the production line (where practicable)
Results from Production Sample Tests (PST) and Routine Tests (RT) checked
(if RT- and PST-test reports are not available, tests according to PST and RT to be carried out)
Review of type approval documentation
Review of possible change in design, materials and performance
Ensure traceability between manufacturer's product type marking and Type Approval Certificate.
Survey shall be performed at least every second year.
END OF CERTIFICATE
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: December 2012
www.dnv.com